• Title/Summary/Keyword: fire occurrence factor

Search Result 43, Processing Time 0.026 seconds

The Applicability Analysis of Life Safety Codes for High Fire Risk Building Applications (화재 위험성을 중심으로 한 건축물 용도별 한국형인명안전기준의 적용성 검토에 관한 연구)

  • Koo, In-hyuk;Kim, Hye-Won;Jin, Seung-Hyeon;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.103-104
    • /
    • 2022
  • In Korea, the occurrence and risk of similar fires are high, so setting up fire prevention measures through fire case investigation is considered the most basic measure in securing human safety. In particular, calculation of evacuation capacity in evacuation safety design of buildings is the most important factor that directly affects evacuation safety performance. However domestic standards is not consider about occupant characteristics. also the case of domestic, it has the problem that the law is partially applied when the fire safety design of buildings. Therefore, the purpose of this study is to study the current status and related regulations of the life safety code for the application of high fire risk buildings, and to analyze the difference in evacuation time through Case Study.

  • PDF

A Study on Protection Device for Electrical Fire Prevention on Joint/Contact Badness Faults (접속·접촉불량 사고에 의한 전기화재 방지용 보호장치에 관한 연구)

  • Choi, Jung-Kyu;Kwak, Dong-Kurl;Lee, Seung-Chul;Lee, Bong-Seob;Park, Young-Jic
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.5-6
    • /
    • 2014
  • According to 2013 fire statistical yearbook in the National Emergency Management Agency, the main cause of an electrical fire are classified to short circuit fault, overload fault, electric leakage, partial disconnection, and joint/contact badness. The occurrence factor of fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Devices(RCDs) of high sensitivity type used at single phase (220V) cut off earth leakage and overload but the RCDs can not cut off electric arc or spark to be a main cause of electrical fire. To be improved on such problem, this thesis is proposed to a auxiliary control device for RCD cut off electric arc or spark.

  • PDF

Electric Safety Protection Device of High Speed for Incapable Operation of ELB and MCCB Using the Low Voltage Distribution Line (저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 고속형 전기안전 보호장치)

  • Kwak, Dong-Kurl;Jung, Do-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1925-1929
    • /
    • 2007
  • This paper is studied on a novel Electric Safety Protection Device (ESPD) of high speed for incapable operation of Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB) using the low voltage distribution line. The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is ELB and MCCB, of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a novel ESPD of high speed to trip of distribution line on electric arc or spark due to electrical fire. Some experimental results of the proposed ESPD are confirmed to the validity of the analytical results.

Development of Arc Fault Circuit Interrupter Using the Distorted Voltage Wave in Electric Arc Faults (아크사고 발생 시 전압 왜형파를 이용한 아크차단기 개발)

  • Kwak, Dong-Kurl
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.876-880
    • /
    • 2013
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The principal factor of the fire is electric arc or spark accompanied with such electric faults. Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB), that is, Residual Current Protective Devices (RCDs) used on low voltage distribution lines cut off earth leakage and overload, but the RCD can not cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied in low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To improve such problems, this paper studies on an arc fault circuit interrupter (AFCI) using the distorted voltage wave in electric arc faults. The proposed voltage sensing type AFCI is an electrical fire prevention apparatus of new conception that operates a circuit breaker with sensing the instantaneous voltage drop of line voltage at electrical faults occurrence. The proposed AFCI is composed of control circuit topology using some semiconductor switching devices. Some experimental tests of the proposed AFCI confirm practicality and the validity of the analytical results.

Frequent Forest Fire in Kosong-Gun, Kangwon Province (고성지방의 산불발생)

  • 이장렬
    • The Korean Journal of Quaternary Research
    • /
    • v.16 no.2
    • /
    • pp.1-8
    • /
    • 2002
  • In this paper, the writer attempts to clarify causes by general man and weather factor on forest fire occurrence in Kosong-Area, 1995-2001. The major results are summarized as follows: The forest fire at Kojin-ri, Sonyusil-ri and Majwa-ri occurred at the same area over 3 times and that Hakya-ri, Songdae-ri and Inhung-ri, at the adjoining land over 3times. In the total 46 times of forest fire, fire frequence was greatest in March(11 time) and April(11 time) followed by November(7 time), January(6 time), February(6 time). December(3 time), October(2 time). Hours on frequent forest fire are from 11:00 till 18:00. Number for forest fire occurrence by causes was greatest in military training followed by burning paddy fields, debris burning, burning agricultural debris, visiting a grave, cigarette and arson. Frequent forest fire in Kosong-Area coincide not only with above normal temperatures, but also with below normal relative humidity. When the strong winds appear at Kosong-Area, the properties of daily surface chart re the south high and north low pressure pattern in the Far East Asia.

  • PDF

A Study on Block from Spread of Fire of the Exteriors Installation Space (외장재 설치 공간의 화재확산 차단에 관한 연구)

  • Min, Se-Hong;Yun, Jung-Eun;Kim, Mi-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.2
    • /
    • pp.83-89
    • /
    • 2012
  • In this study, FDS fire simulation experiments and measured wind speed by applying the exterior installation portion for blocking the spread of the fire was investigated. As a result, aluminum composite panels installed in the lower and the upper part of the panel to remove all the lower side, and then the maximum wind speed 0.24 m/s and the upper side 0.58 m/s were measured. In the FDS, the measured wind speed difference air currents are approximately 3.7 times in 12 seconds, the occurrence of 17 seconds early moment wind 2.2 m/s was measured from. Before and after the fire occurred in early of the air velocity about 39 seconds was 3.5 times difference. Such air currents caused by the temperature of the building but also by the building height was found. Turbulent flame of fire by expanding the vertical extent of damage become greatly important factor. Therefore, through the exterior installation portion of the block that can delay the spread of fire is expected that this should be taken.

Development of Prevention Apparatus for Short-Circuit Faults Using the Line Voltage Drop of Neutral Wire (중성선 선로 전압강하를 이용한 단락사고 방지용 보호장치 개발)

  • Kwak, Dong-Kurl;Kim, Jin-Hwan;Lee, Bong-Seob
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1953-1958
    • /
    • 2012
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with such electric faults, specially short circuit faults. Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB), that is, Residual Current Protective Devices (RCDs) used on low voltage distribution lines cut off earth leakage and overload, but the RCD can not cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied in low voltage distribution panel are prescribed to rated breaking time about 30ms(KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To improve such problem, this paper proposes a prevention apparatus using the line voltage drop of neutral wire and some semiconductor switching devices. Some experimental tests of the proposed apparatus confirm the validity of the analytical results.

Development of Risk Assessment Index in Special Management Target Facilities According to the Fire Occurrence Factors (화재발생 요인에 따른 특정관리대상시설등의 위험도 평가 지수의 분석 및 개발)

  • Park, Mi Yun;Park, Jong Bok;Park, Jae Hak
    • Journal of Korean Society of Disaster and Security
    • /
    • v.5 no.2
    • /
    • pp.61-70
    • /
    • 2012
  • The range of special management target facilities is seperated by the building sector and the field of civil engineering. In the present study, the risk analysis was performed, related to fire occurred for the last five years, in the field of residential and non-residential facilities in buildings. Most of fire incidents occurred in residential and non-residential facilities was the cause of the electrical, and the resulting casualties were also very high. Therefore, based on the results, the risk evaluation index was developed, identifying the causes of fire occur and doing the fire vulnerability analysis for each facility. The result of this study can be utilized safety management to these facilities for the future, especially, inducing a more specialized and intensive safety management.

A Study on the Risks Factors of Fire Occurrence and Expansion for Traditional Markets (전통시장 화재 발생 및 확대 위험요인에 관한 연구)

  • Kim, Jung-Gon;Park, Chang-Il;Jung, Jae-Wook;Kim, Seong-Gon
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.60-67
    • /
    • 2021
  • Purpose: Traditional markets often have irregular space utilization patterns because the spaces are created and divided as time passed. Internally, there is high risk of fire due to problems such as aging facilities and high-density of stores and externally, there is high risk of fire spread since it is often adjacent to deteriorated residential and commercial facilities. Method: In this paper, on-site investigations were carried out to check fire risk factors and fire spread risk, and fire occurrence and expansion risk factors were investigated for traditional markets in Hwanghak-dong and Dong-daemun by using large-scale fire data from existing traditional markets. Result: As a result of the analysis, there are likely to be various problems such as high fire load and lack of safety awareness due to aging facilities and high-density of stores. In particular, it is necessary to prepare countermeasures because deteriorated residential facilities with narrow alleys around traditional markets have high fire spread. It is situation that while traditional markets mainly are managing for fire and disaster centering on the merchant association, the surrounding residential areas are not properly managed. Conclusion: It is necessary to manage deteriorated residential facilities with traditional markets, also to be linked early warning system and information to evacuate rapidly in case of fire there.

A Study on Auxiliary Control Safety Apparatus for RCD Trip on Electric Arc and Spark Disasters - Using by Power Semiconductor Switching Device - (아크 및 스파크 재해에 대한 누전차단기 트립을 위한 보조제어 전기안전장치에 관한 연구 - 전력용 반도체 스위칭 소자 적용 및 응용 -)

  • Kwak, Dong-Kurl;Shin, Mi-Young;Jung, Do-Young
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.71-76
    • /
    • 2006
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device(RCD) of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms](KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this paper is proposed to a auxiliary control apparatus for RCD trip on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.