• Title/Summary/Keyword: fire monitoring

Search Result 394, Processing Time 0.027 seconds

Development of Electric safety monitoring system for reducing the electrical fire at traditional market (재래시장 전기화재 감소를 위한 전기안전감시시스템 개발 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Bae, Suk-Myong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.259-262
    • /
    • 2009
  • This paper in order to reduce the electric disaster damage which is caused by with electric equipment of traditional market developed the electric safety monitoring system which is suitable in traditional market. With for this did the actual condition investigation about electrical equipment of traditional market and we constructed Test-bed for testing reliability of electric safety monitoring system. Also experiment led in Test-bed and confirmed a stability. This paper following will be used with the data for the reliability security of the electric safe system operation which follows in the traditional market actual proof equipment construction which will be advanced.

  • PDF

Development of Single Phase Cabinet Panel with Electrical Safety Monitoring System by Mobile (모바일 이용 가능형 ESMS 기능의 단상 분전반 개발 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Shin, Seong-Su;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.92-96
    • /
    • 2011
  • In this paper, in order to reduce the electrical disaster such as electrical fire at traditional markets, we need to develop the ESMS(electrical safety monitoring system) which is able to monitor the power status of electrical equipments. Therefore, for solving the those problems, we developed the detection censor(ZCT, CT) and equipment of data analysis and transmission. The detection censor and equipment are able to monitor the electrical equipments condition(over current, leakage current, arc, etc.). We constructed Test-Bed for testing reliability of the ESMS and obtained certification. And we tested the over current, leakage current and arc under the normal condition.

Design and Implementation of Real-time monitoring for Distributed Server Management (분산된 서버 관리를 위한 실시간 모니터링 설계 및 구현)

  • Lee, Jong-Dae;Koo, Yong-Wan
    • Journal of Internet Computing and Services
    • /
    • v.9 no.1
    • /
    • pp.69-78
    • /
    • 2008
  • Finance, Securities, banking system provides information through Internet, DM SMS, IVR, E-mail and FAX for customer. Customers can use multi channel. Enterprise requires Host transaction and transparency for DB processing, This paper provides two contributions to the study. First, we discuss Server of Fire insurance (finance, securities and capital, bank system) in Enterprise. Second, we present Real time monitoring system for customer transparency. Finally, we design and implement the proposed system. These techniques can be efficiently supported in CRM(Customer Relationship Management).

  • PDF

Development of the Cabinet Panel of Real-Time Availability Checks for Electrical Disaster Decreasing at Traditional Markets (재래시장 전기재해 감소를 위한 실시간 확인이 가능한 분전반 개발)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Shin, Seong-Su;Bae, Seok-Myung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.3
    • /
    • pp.335-339
    • /
    • 2010
  • In this paper, in order to reduce the electrical disaster damage which is caused by with electrical equipment of traditional markets, we developed the cabinet panel and the electrical safety monitoring system which is able to monitor the electrical equipments condition(over current, leakage current, arc, WH, electrical fire factor etc.) at traditional markets. We constructed Test-bed for testing reliability of electrical safety monitoring system and cabinet panel. And we tested the cabinet for over current, leakage current and arc under the traditional markets actual condition. This paper will be used with the data for an demonstration project after compensating the defects which are occurred to operation of traditional markets actual loads.

Satellite Monitoring of Smoke Aerosol Plume during the Russian Fire Episode of May 2003 over Northeast Asia

  • Lee, Kwon H.;Kim, Young J.;Hoyningen-Huene, Wolfgang V.
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.491-492
    • /
    • 2003
  • The large amount of smoke produced near Lake Baikal was transported to Northeast Asia with high AOT (Aerosol Optical Thickness) as seen in satellite images. Aerosol retrieval using a separation technique was applied to MODIS (Moderate Imaging Spectroradiometer) and SeaWiFS (Sea-viewing Wide Field-of-view Sensor) data observed during 14-22 May 2003. Large AOT, 2.0~5.0 was observed on 20 May 2003 over Korea due to the influence of the long range transport of smoke aerosol plume from the Russian fires, resulting in high PM10 concentration was observed at the surface.

  • PDF

Fabrication of smart alarm service system using a tiny flame detection sensor based on a Raspberry Pi (라즈베리파이 기반 미소 불꽃 감지를 이용한 스마트 경보 서비스 시스템 구현)

  • Lee, Young-Min;Sohn, Kyung-Rak
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.953-958
    • /
    • 2015
  • Raspberry Pi is a credit card-sized computer with support for a large number of input and output peripherals. This makes it the perfect platform for interaction with many different devices and for usage in a wide range of applications. When combined with Wi-Fi, it can communicate remotely, therefore increasing its suitability for the construction of wireless sensor nodes. In addition, data processing and decision-making can be based on artificial intelligence, what is performed in developed testbed on the example of monitoring and determining the confidence of fire. In this paper, we demonstrated the usage of Raspberry Pi as a sensor web node for fire-safety monitoring in a building. When the UV-flame sensors detect a flame as thin as that of a candle, the Raspberry Pi sends a push-message to notify the assigned smartphone of the on-site situation through the GCM server. A mobile app was developed to provide a real-time video streaming service in order to determine a false alarm. If an emergency occurs, one can immediately call for help.

Design of Simulation Environment for Intelligent Disaster Prevention System and Implementation of Management Application (지능형 방재 시스템 시뮬레이션 환경 및 관리 어플리케이션 구현)

  • Cho, Young-Ho;Kang, Heau-Jo;Sung, Kyung
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.4
    • /
    • pp.602-608
    • /
    • 2011
  • In this paper, we implemented an android mobile management application of intelligent prevention of disaster system which can manage the current status monitoring and whether operating or not by using Ubiquitous Sensor Network based self wireless communication system of scattered emergency light, fire extinguishers and sprinkler inside the high complex building. This system is composed with fire facilities attached sensor nodes, management server for collection of information and control, and smart phone application that transmits and receives information with management server. As a result of the test, the embodied android-based smart phone application to be performed anywhere could confirm status and monitoring information of fire facilities which are communicated with the management server.

Monitoring of Vegetation Recovery According to Natural and Artificial Restoration Methods After Forest Fire Damage Using Satellite Imagery (위성영상을 이용한 산불피해 이후 자연복원과 인공복원 방법에 따른 식생회복 모니터링)

  • Hwang, Yeong In;Kang, Won Seok;Park, Ki Hyung;Lee, Kyeong Cheol;Han, Sang Gyun;Kweon, Hyeong Keun
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.24 no.3
    • /
    • pp.33-43
    • /
    • 2022
  • This study was conducted to monitor the vegetation recovery in the areas damaged by the forest fires on the east coast that occurred in April 2000. The study site was a forest fire-damaged area in Samcheok-si, Gangwon-do, and 21 monitoring areas (12 natural restoration sites, 9 artificial restoration sites) were selected to analyze the vegetation recovery trend since 1998. The vegetation recovery trend was compared by calculating the values according to the year using the difference Normalized Burn Ratio (dNBR) and Normalized Difference Vegetation Index (NDVI) based on satellite images (Landsat TM/ETM+ and Sentinel-2A). As the result of this study, all 21 sites, vegetation was recovered, and both groups showed the greatest recovery in summer. In the case of the dNBR, the artificial restored sites showed higher values than the natural restored sites, and in the case of the NDVI, the natural restored sites were higher than the artificially restored sites in summer and autumn. However, the difference between the two groups of natural and artificial restoration sites was not significant. Therefore, the direction of forest restoration after forest fire damage can be effectively restored if properly implemented for the purpose of restoration of the target site.

DSP Embedded Early Fire Detection Method Using IR Thermal Video

  • Kim, Won-Ho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.10
    • /
    • pp.3475-3489
    • /
    • 2014
  • Here we present a simple flame detection method for an infrared (IR) thermal camera based real-time fire surveillance digital signal processor (DSP) system. Infrared thermal cameras are especially advantageous for unattended fire surveillance. All-weather monitoring is possible, regardless of illumination and climate conditions, and the data quantity to be processed is one-third that of color videos. Conventional IR camera-based fire detection methods used mainly pixel-based temporal correlation functions. In the temporal correlation function-based methods, temporal changes in pixel intensity generated by the irregular motion and spreading of the flame pixels are measured using correlation functions. The correlation values of non-flame regions are uniform, but the flame regions have irregular temporal correlation values. To satisfy the requirement of early detection, all fire detection techniques should be practically applied within a very short period of time. The conventional pixel-based correlation function is computationally intensive. In this paper, we propose an IR camera-based simple flame detection algorithm optimized with a compact embedded DSP system to achieve early detection. To reduce the computational load, block-based calculations are used to select the candidate flame region and measure the temporal motion of flames. These functions are used together to obtain the early flame detection algorithm. The proposed simple algorithm was tested to verify the required function and performance in real-time using IR test videos and a real-time DSP system. The findings indicated that the system detected the flames within 5 to 20 seconds, and had a correct flame detection ratio of 100% with an acceptable false detection ratio in video sequence level.

An Integrated Approach of CNT Front-end Amplifier towards Spikes Monitoring for Neuro-prosthetic Diagnosis

  • Kumar, Sandeep;Kim, Byeong-Soo;Song, Hanjung
    • BioChip Journal
    • /
    • v.12 no.4
    • /
    • pp.332-339
    • /
    • 2018
  • The future neuro-prosthetic devices would be required spikes data monitoring through sub-nanoscale transistors that enables to neuroscientists and clinicals for scalable, wireless and implantable applications. This research investigates the spikes monitoring through integrated CNT front-end amplifier for neuro-prosthetic diagnosis. The proposed carbon nanotube-based architecture consists of front-end amplifier (FEA), integrate fire neuron and pseudo resistor technique that observed high electrical performance through neural activity. A pseudo resistor technique ensures large input impedance for integrated FEA by compensating the input leakage current. While carbon nanotube based FEA provides low-voltage operation with directly impacts on the power consumption and also give detector size that demonstrates fidelity of the neural signals. The observed neural activity shows amplitude of spiking in terms of action potential up to $80{\mu}V$ while local field potentials up to 40 mV by using proposed architecture. This fully integrated architecture is implemented in Analog cadence virtuoso using design kit of CNT process. The fabricated chip consumes less power consumption of $2{\mu}W$ under the supply voltage of 0.7 V. The experimental and simulated results of the integrated FEA achieves $60G{\Omega}$ of input impedance and input referred noise of $8.5nv/{\sqrt{Hz}}$ over the wide bandwidth. Moreover, measured gain of the amplifier achieves 75 dB midband from range of 1 KHz to 35 KHz. The proposed research provides refreshing neural recording data through nanotube integrated circuit and which could be beneficial for the next generation neuroscientists.