• Title/Summary/Keyword: fire growth

Search Result 350, Processing Time 0.036 seconds

Numerical study on the post-earthquake fire behavior of intermediate steel moment frames

  • Parvizizadeh, Shayan;Kazemi, Mohammad Taghi
    • Earthquakes and Structures
    • /
    • v.22 no.2
    • /
    • pp.137-145
    • /
    • 2022
  • As steel is highly sensitive to temperature variations, fire exposure is more destructive in the case of steel structures in comparison to the concrete ones. The performance of an intermediate three-story steel moment frame with 4 spans was studied under the service load, thermal load and post-earthquake fire in this paper. Also, the effects of passive fire-protection materials such as ordinary cement-based and fire-retardant coatings were investigated. To model and analyze the structure; Abaqus software is utilized. In order to apply the earthquake effect, the push-over analysis method is employed. Changes in the stories deflection, endurance time and growth of nonlinear regions due to losses in the steel stiffness and strength, are among the issues considered in this study. As an interesting finding, the beams protected by ordinary cement-based coating could sustain the fire exposure at least for 30 minutes in all cases. The mentioned time is increased by employing a new fire-retardant protection, which could prevent significant loss in the structure resistance against fire, even after 60 minutes of exposure to fire.

A Study on the Characteristics of FDS Heat Release Rate Predictions for Fire involving Solid Combustible Materials in a Closed Compartment (밀폐된 구획 내 복합소재 고체 가연물의 연소시 열방출률의 FDS 예측 특성)

  • Hong, Ter-Ki;Roh, Beom-Seok;Park, Seul-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.349-356
    • /
    • 2020
  • The heat release rate (HRR) and fire growth rate of fire for the solid combustibles consisting of multi-materials was measured through the ISO 9705 room corner test, and the computational analysis in a closed compartment was performed to simulate a fire using the heat release rate prediction model provided by a Fire Dynamics Simulator (FDS). The method of predicting the heat release rate provided by the FDS was divided into a simple model and a pyrolysis model. Each model was applied and computational analysis was performed under the same conditions. As the solid combustible consisting of multi-materials, a cinema chair composed mostly of PU foam, PP, and steel was selected. The simple model was over-predicted compared to the predicted heat release rate and fire growth rate using the pyrolysis model in a closed compartment.

Fire Risk of Wood Treated With Boron Compounds by Combustion Test (연소시험에 의한 붕소 화합물 처리 목재의 화재위험성)

  • Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.19-26
    • /
    • 2018
  • Experiments on the combustion characteristics of untreated wood specimens and also treated ones with boric acid and ammonium pentaborate were carried out using a cone calorimeter according to ISO 5660-1 standard. As a result, comparing to untreated specimen, the fire performance index (FPI) of the specimens treated with boron compounds increased by 1.2 to 2.1 times and the fire growth index (FGI) increased by 1.6 to 8.4%. Also, total smoke release rate (TSR) was 9.0 to 28.3% lower than that of the untreated specimen. It is understood that the test specimens treated with the boron compound produces a carbonized layer with a flame retarding effect. The highest CO concentration, 0.01112%, for the untreated specimen was observed at 418 s, but the specimens treated with boron compound decreased 13.2 to 37.5% compared to untreated specimen. Therefore, wood treated with boron compounds is expected to have lower fire hazards and risks.

An Experimental Study on the Formation of Smoke Layer of Compartment Fire (건물화재시 연기층의 형성에 관한 실험적연구)

  • 허만성
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.1
    • /
    • pp.94-100
    • /
    • 1997
  • The objective of this research is to study the formations of smoke layer in case of several furniture fires such as trashcan, carpet, mattress and wardrobe as a fire starter in a residential room by performing the experimental studies. The uniformly distributed fire in case of carpet showed that the ignition and the initial growth period were relatively short while the fully developed period was considerably long. The concentrated fires such as the trashcan, mattress and wardrobe showed that the ignitions and the initial growth periods were relatively long. The descending speed of the interface height was proportioned to the inflammability of the furniture and the spread of the fire. The time required to come down around 1m was within 1-3 minutes. The Interface heights for the furniture fires were around 1m as the steady state. However, at the time of the maximum temperature, the interface height was lowered to 0.25m-0.75m from the floor. The carbon dioxide concentration reached the highest while the oxygen concentration was minimum.

  • PDF

The Study on the Fire Characteristic of Sandwich Panel by SBI(Single Burning Item) (SBI(Single Burning Item)을 이용한 샌드위치패널의 화재특성 연구)

  • Kim, Jung-Hyun;Kim, Heoung-Youl;Lim, Young-Soo;Lee, Seung-Han
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.493-500
    • /
    • 2010
  • 본 연구에서는 EN 13823 기준을 적용한 시험방법인 SBI(Single Burning Item)을 이용하여 스티로폼 샌드위치패널의 화재특성에 대한 실험을 실시하였다. 현재 국내에서는 샌드위치패널 화재특성 평가방법으로 ISO 5660-1(콘칼로리미터 시험방법)과 KS F 2271(난연성시험)이 사용되고 있지만 이러한 시험방법들은 시험 스케일과 시험편 및 가열조건의 한계점 등을 보이고 있다. 따라서 본 연구에서는 1세트를 3개로 하여 총 9개의 75mm 두께인 스티로폼 샌드위치 패널을 이용한 실험을 실시하였다. 이를 통해 공학적인 화재 물성 값인 FIGRA(FIre Growth RAte, kW/s), SMOGRA(SMOke Growth RAte, m2/s2)등을 측정하였다.

  • PDF

Burning Characteristics of Wood-based Materials using Cone Calorimeter and Inclined Panel Tests

  • Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.18-25
    • /
    • 2002
  • Research to discuss the fire performance of materials requires tools for measuring their burning characteristics and validated fire growth models to predict fire behavior of the materials under specific tire scenarios using the measured properties as input for the models. In this study, burning characteristics such as time to ignition, weight loss rate, flame spread, heat release rate, total heat evolved, and effective heat of combustion for four types of wood-based materials were evaluated using the cone calorimeter and inclined panel tests. Time to ignition was affected by not only surface condition and specific gravity of the tested materials but also the type and magnitude of heat source. Results of weight loss rate, measured by inclined panel tests, indicated that heat transfer from the contacted flame used as the heat source into the inner part of the specimen was inversely proportional to specific gravity of material. Flame spread was closely related with ignition time at the near part of burning zone. Under constant and severe external heat flux, there was little difference in weight loss rate and total heat evolved between four types of wood-based panels. More applied heat flux caused by longer ignition time induced a higher first peak value of heat release rate. Burning characteristics data measured in this study can be used effectively as input for fire growth models to predict the fire behavior of materials under specific fire scenarios.

Changes of Landscape Pattern and Vegetation Structure in Rural Areal Area Disturbed by Fire (산불지역에서 경관유형과 식생구조의 변화)

  • 이창석;홍선기
    • The Korean Journal of Ecology
    • /
    • v.21 no.4
    • /
    • pp.389-399
    • /
    • 1998
  • this study was focused on the effects of fire on spatial change of vegetation landscape in rural region. Fire types recognized as erown fire, severe surface fire and light surface fire in order of increasing intensity were described in a fire map. GIS was introduced to understand the relationship between fire types and topographic conditions or vegetation types. We also investigated land-use type and regeneration strategies after burning. Fire intensity depended on topographic conditions and vegetation types. Special land-use type in this area was collection of edible mushroom (Tricholoma matsutake). Mushrooms had been obtained from Pinus densiflora forests existing as edaphic climax or managed artificially. Regeneration strategy in burned areas was to make sprouts from burned oak stumps. A higher density and growth rate of sprouts, as compared to those on unburned areas, facilitated vegetation succession from P. densiflora forest to oak forest and consequently led to change of landscape pattern.

  • PDF

A Basic Study on the Fire Experiment of a Single Area for Fire Safety Design. (단일구획실험을 통한 화재안전설계에 관한 기초적 연구)

  • Kim, Dong;Yoon, Ung-Gi;Seo, Dong Goo;Kwon, Young Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.110-111
    • /
    • 2013
  • This research studies in the field of domestic fires are an issue in many scientific fire research as a research method to validate the domestic environment and ISO-9705 housing on the basis of experiments in virtual space by making a single fire compartment space for conducting experiments and Appearance of a fire occurring within each flammable Heat Release Rate analysis was carried out mainly. Placed within the space of one flammable HRR calculated as the sum of the number of single-room fire experiments conducted and the results compared with the value in comparing the conduct of fire locations and fire load within the building area of the future, the HRR value represents the change in domestic a consideration of the safety of the building is to propose matters.

  • PDF

An Experimental Study on the Applicability of Plate Thermometer in Steady and Unsteady-State Fire Conditions (정상 및 비정상상태의 화재조건에서 판형 열유속계의 적용성에 관한 실험적 연구)

  • Yun, Hong-Seok;Mun, Sun-Yeo;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.34-41
    • /
    • 2015
  • The applicability of plate thermometer (PT), which feature simple installation and low cost, was experimentally examined in steady and unsteady-state fire conditions. An infrared radiation heater and a square burner with C3H8 as fuel were used as heat sources. The relative measurement accuracy of the PT was evaluated by comparing measurements made using a Gardon-type heat flux meter. From a practical point of view and in terms of measurement accuracy, the optimal size and thickness of the PT in steady and unsteady-state fire conditions were 100 mm and 0.6 mm, respectively. These results can be explained by the conductive heat losses and thermal inertia of the PT for different sizes and thicknesses. It can be also concluded that measurements of heat flux using the PT in conditions of faster fire growth rate than slow require considerable attention.

A Investigation Study on the Development of Egress Simulation for Evacuation Safety Evaluation of Tokyo Fire Dept. Department in Japan (일본 동경소방청의 피난안정성평가 시뮬레이션 기술개발 사례연구)

  • Lee, Hyun-Jin;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.216-222
    • /
    • 2008
  • A large number of Computer-based fire growth and Evacuation model have been developed for various purpose and many of these are widely used for research and engineering. And Most of Egress simulation program are ordinary case only related to human behavior But Egress safety Evaluation is very closed to smog movement. It is well known that the Egress simulation program made by Tokyo Fire Department are related to smog movement. So It is the aim of this study to investigate on the Development of Egress Simulation for Evacuation Safety Evaluation of Tokyo Fire Dept. Department in Japan.

  • PDF