• 제목/요약/키워드: fire criteria

검색결과 294건 처리시간 0.026초

성능에 기반을 둔 목조건축물 화재안전기준 개선방안 (Improvement of Performance based wooden building National Fire Safety Codes)

  • 오택흠;박찬석
    • 대한안전경영과학회지
    • /
    • 제18권2호
    • /
    • pp.83-92
    • /
    • 2016
  • Because National Fire Safety Codes is mixed performance criteria and specification, and it defines the fire extinguish equipment type and standards that need to be installed in a building as one method. Therefore, to fully reflect the fire risk characteristics of the building, such as the wooden building there is a limit. In this study, suggested to the performance criteria drawn methodologies through fire load of wooden buildings studies, theory on performance and performance analysis to fire extinguish equipment of the wooden buildings is installed according to current fire safety codes.

화재하중밀도를 고려한 건축물의 내화설계법에 관한 연구 (A Study on the Fire Resistance Design of Buildings Considering the Fire Load Energy Density)

  • 이평강;이용재;최인창;김회서
    • 한국화재소방학회논문지
    • /
    • 제17권2호
    • /
    • pp.10-16
    • /
    • 2003
  • 본 연구의 목적은 성능위주의 화재안전설계법에 따른 구획실 용도별 요구내화시간산정을 실시함으로써 현행 내화성능기준의 문제점도출 및 개선방향을 제시하는 것이다. 내화성능기준에 대한 검토를 위해 본 연구에서는 현재 국내의 시방규정에 의해 결정된 요구내화시간과 등가시간공식에 의해 산정된 화재노출상응시간과 비교하였고, 화재노출상응시간을 산정하기 위해 화재하중밀도, 환기계수, 구조재료의 열적특성 그리고 구획실 형상치수 등을 조사하였다.

강재단면형상을 고려한 소요 내화피복 두께 산정에 관한 연구 (A Study on the Determination of Required Fire Protection Thickness Considering Steel Section Shape)

  • 김해수;강종
    • 한국산학기술학회논문지
    • /
    • 제12권12호
    • /
    • pp.5910-5916
    • /
    • 2011
  • 강재는 단면의 종류와 크기 및 부재에 따라 화재에 노출되는 표면적이 달라지며, 이에 따라 화재에 의한 강재의 온도상승도 큰 차이를 나타낸다. 단면형상계수($H_p$/A)는 강재의 종류, 크기, 적용부재 및 내화피복재의 종류 등의 변수에 따라 결정되며, 이것은 내화피복 두께를 결정하는 기준이 된다. 본 연구를 통하여 강재는 종류에 관계없이 단면의 크기가 증가할수록 단면형상계수는 감소하는 것을 알 수 있었다. 단면형상계수에 따른 강재의 종류별 내화피복 두께 산정 결과 1시간 내화성능은 기준보다 소요 두께가 30~50% 낮게 나타났다. 또한, 2시간 내화성능은 기준보다 소요 두께가 최저 27% 낮게 산정되는 부재도 있으나 대체로 기준에 근접하는 것을 알 수 있었다. 그러나 H형강의 경우 3시간 내화성능은 대체로 기준을 만족하지만 각형강관과 원형강관의 경우 5.0~17.5% 정도 기준을 상회하는 값으로 나타났다.

수직 배연구의 자연배연 성능에 관한 수치해석연구 (A Numerical Study for the Performance of Natural Smoke-venting of a Vertical Vent)

  • 전흥균;최영상;추홍록
    • 한국화재소방학회논문지
    • /
    • 제22권4호
    • /
    • pp.1-10
    • /
    • 2008
  • 본 연구에서는 미국 NFPA 204 기준에 의해 설계된 수직 배연구에 대하여 배연구의 위치, 외기 온도, 풍속 및 화재크기가 자연배연 성능에 미치는 영향과 화재특성을 CFAST 프로그램을 사용하여 수치 해석적으로 조사하였다. 배연구는 외벽의 최고 상부에 위치한 경우와 외기온도가 낮은 경우 및 풍속이 작은 경우 배연성능기준을 만족하였다. 또 화재크기가 클수록 배출량은 증가하나 연기층 높이는 낮아져 배연성능기준을 만족하지 못하였다. 직접 외기와 통하는 수직 자연배연구의 설계시 해당지역의 최고 온도와 최대 풍속을 고려하고, 설계화재를 정확히 결정하여 배연성능기준이 만족되도록 주의가 요망된다.

틸팅차량용 내장재 화염성능에 대한 기준 제시 및 평가 기술 (Criteria Proposal and Evaluation Technique for Fire Performance of TTX Interior Components)

  • 이상진;정종철;조세현;구동회
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 춘계학술발표대회 논문집
    • /
    • pp.43-46
    • /
    • 2004
  • Through investing the criteria and evaluation for fire performance of interior components, this paper introduce the testing items and requirements for Flammability, Smoke density, and Toxicity properties of TTX(Tilting Train eXpress) interior parts. Next time, all trains including TTX will be occupied the components with superior fire-resistance and the sensing and monitoring system for fire in train.

  • PDF

컵버너시험에서 소화기준에 따른 불활성기체의 소화농도에 대한 정량적 차이 (Quantitative Difference in the Extinguishing Concentration of Inert Gases with Fire Suppression Criteria in a Cup Burner Test)

  • 조재호;황철홍
    • 한국화재소방학회논문지
    • /
    • 제28권3호
    • /
    • pp.34-42
    • /
    • 2014
  • 본 연구에서는 $CH_4$$C_3H_8$ 연료의 컵버너 비예혼합화염에서 Swing, Rotation, Lifted 및 Blow-out과 같은 화염 불안정성을 발생시키는 불활성기체($N_2$, Ar, $CO_2$ 및 He)의 농도를 측정하였으며, 소화기준(즉, 화염날림 또는 화염불안정성 개시)에 따른 소화농도의 정량적 차이를 검토하였다. 소화농도의 차이는 부상화염의 발생 그리고 낮은 소화성능의 불활성기체일수록 증가됨을 확인하였다. 소화기준에 따른 소화농도의 최대 차이는 $C_3H_8$-air 비예혼합화염의 최대 연료유속의 조건(1.3 cm/s)에서 약 35%이다. 또한 화염 불안정성의 개시를 기준으로 측정된 소화농도는 정확한 그리고 경제적 설계 농도의 관점에서 유용한 정보를 제공할 것으로 기대된다.

도장공사 하자판정기준 개선 및 방화문 교체 주기 설정에 관한 법령 개정안 제안 연구 (A Study on the Proposal of Amendment of Laws and Regulations on the Improvement of Defect Determination Criteria for Painting Work and the Establishment of Replacement Cycle for Fire door)

  • 김수연;권영진;김윤성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.95-96
    • /
    • 2022
  • Based on the analysis of defects occurring before and after painting work, this study intends to derive a reasonable improvement in judgment criteria and propose an amendment to the relevant law through the establishment of a clear fire door replacement cycle in terms of fire safety.

  • PDF

SIMPLE Algorithm을 이용한 화재실의 열 유체의 수치해석 (Numerical Analysis of Heat Flow in Fire Compartment using SIMPLE Algorithm)

  • 김광선;손봉세
    • 한국화재소방학회논문지
    • /
    • 제6권1호
    • /
    • pp.17-22
    • /
    • 1992
  • We have derived the general transfer equation for governing the continuity, energy transfer, mass and momentum transfer, and turbulent energy dissipation rate within the fire compartment which has the 800t fire source at the center of the floor. The governing transfer equations have been descretized using the finite volume approach and numerically experimented under the SIMPLE algorithm. In order for the SIMPLE algorithm approach to be physically reliable, the test results are compared with those of Morita's SOR Method using Conjugate Residual Method and found to be close to physical values though the computational convergence time still remains to be upgraded. The treatment of source terms in the system of finite difference equations has been critical in order to converge the governing equations within the appropriate time steps. The criteria of convergence allowance for the whole domain have been checked and the sudden change of the non-linear effects from the source term have been avoided. The criteria has been allowed to be for 5$\times$10$^{-5}$ .

  • PDF

화재하중을 고려한 대공간 제배연 용량 최적화 연구 (Optimization for Ventilation Capacity of Large Enclosure Considering Fire Load)

  • 안찬솔;김아람
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.478-481
    • /
    • 2011
  • This study is intended to evaluate and optimize the characteristics of smoke spreading and the appropriateness of evacuation time extended by operation of smoke control system during fire within the underground space of the building structured in compliance with the smoke control system performance criteria from the local fire safety standard, which has been currently applied to the buildings in Korea. Using the heat release per unit weight of the combustibles, a numerical analysis both in case of smoke control system in operation and the system not in operation was carried out at the several different shopping malls. From the viewpoint of securing the evacuation time, the results were compared in an attempt to assess the appropriateness of the fire safety criteria.

  • PDF

심병증 진단요건의 표준 설정을 위한 연구 (Study on Establishment of criteria for Heart Disease in Oriental Medicine)

  • 최선미;박경모;정찬길;성현제;안규석
    • 동의생리병리학회지
    • /
    • 제17권4호
    • /
    • pp.845-851
    • /
    • 2003
  • The objective is to establish the standard of criteria for differential diagnosis of signs and symptoms. This study selected signs and symptoms related to heart which stands for Fire(火) as a kind of five phase(五行). Eleven experts was asked to evaluate the adequateness of criteria which was developed by Korea Institute of Oriental Medicine(KIOM) and to suggest the amendment of them. To implement the study, we used the questionnaire which asks about the diagnosis criteria for an insufficiency of the heart-qi(心氣虛證), deficiency of the heart blood(心血氣證), deficiency of the heart-yin(心陰虛證), insufficiency of the heart-yang(心陽虛證), exuberant fire due to hyperactivity of the heart(心火亢盛證), stagnation of the heart blood(心血瘀阻證), heart disturbed by phlegm-fire(痰火擾心證), attack of the heart by retainedfluid(水氣凌心證). Every criteria consists of primary symptoms, secondary symptoms, tongue findings. and pulse findings. In perspectives of the classification of patterns for signs and symptoms and criteria for diagnosis, the result shows that the previous standard doesn't have so many problem. So many of experts were agree with the criteria which was suggested but the trend is that they use, in their actual practice, less than the criteria. Additionally, they pointed that every element in a criterion should have the different weight value, criteria for the overlapped pattern should be added, and, in future, criteria which are based on clinical investigation should be established.