• Title/Summary/Keyword: fire criteria

Search Result 294, Processing Time 0.023 seconds

Improvement of Performance based wooden building National Fire Safety Codes (성능에 기반을 둔 목조건축물 화재안전기준 개선방안)

  • Oh, Taek-Hum;Park, Chan-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.2
    • /
    • pp.83-92
    • /
    • 2016
  • Because National Fire Safety Codes is mixed performance criteria and specification, and it defines the fire extinguish equipment type and standards that need to be installed in a building as one method. Therefore, to fully reflect the fire risk characteristics of the building, such as the wooden building there is a limit. In this study, suggested to the performance criteria drawn methodologies through fire load of wooden buildings studies, theory on performance and performance analysis to fire extinguish equipment of the wooden buildings is installed according to current fire safety codes.

A Study on the Fire Resistance Design of Buildings Considering the Fire Load Energy Density (화재하중밀도를 고려한 건축물의 내화설계법에 관한 연구)

  • 이평강;이용재;최인창;김회서
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.10-16
    • /
    • 2003
  • The main purpose of this study is to raise the point at issue and to propose reform direction about the current performance criteria of fire resistance through the examination of the fire resistance required for each use of compartment by using performance-based fire safety design method. To examine the performance criteria of fire resistance, this study compared the equivalent time of fire exposure which was calculated by using time-equivalent formulae with the required fire resistance time determined by existing prescriptive code, and surveyed factors such as the fire load energy density, ventilation factor, fire compartment materials and fire compartment geometry in order to calculate the equivalent time of fire exposure.

A Study on the Determination of Required Fire Protection Thickness Considering Steel Section Shape (강재단면형상을 고려한 소요 내화피복 두께 산정에 관한 연구)

  • Kim, Hae-Soo;Kang, Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5910-5916
    • /
    • 2011
  • Surface area of the steel member exposed to fire differs according to type and size of the section and the kind of the member, which shows a big difference in the temperature rise of the steel by fire. The section factor ($H_p$/A) is determined by factors such as type, size, and member of the steel and type of the fire protection material, and it is the criteria in determining thickness of the fire protection material. This study showed that the size of the steel increase regardless of the steel type, the section factor decrease. In the results on fire protection thickness of the steel according to the section factor, the efficiency of 1 hour fire protection was lower from 30 to 50% than the criteria. And there is the member, which have the thickness lower the minimum 27% in 2 hour fire protection, but it generally approached in the criteria. In case of H-shape steel, the efficiency of 3 hour fire protection was suitable for the criteria, but rectangular hollow steel section and circular hollow steel section were higher (5.0-17.5%) than the criteria.

A Numerical Study for the Performance of Natural Smoke-venting of a Vertical Vent (수직 배연구의 자연배연 성능에 관한 수치해석연구)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.1-10
    • /
    • 2008
  • In this study, the effects of vent location, outside temperature, wind velocity and fire size on the performance of natural venting of the vertical vent designed according to NFPA 204 standard and fire characteristics were numerically investigated using CFAST. In cases of the Vent located on most upper wall, lower outside temperature and lower wind velocity, vents met the performance criteria of venting. The larger fire size becomes, the more mass flow rate through a vent becomes, but the lower interface height of smoke layer becomes, so that vent didn't meet the performance criteria of venting. It should be noted that a natural vertical vent be designed considering maximum outside temperature and maximum wind velocity and developing a design fire accurately in order to meet the performance criteria of venting.

Criteria Proposal and Evaluation Technique for Fire Performance of TTX Interior Components (틸팅차량용 내장재 화염성능에 대한 기준 제시 및 평가 기술)

  • Lee Sang-Jin;Jeong Jong-Cheol;Cho Se-Hyun;Koo Dong-hae
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.43-46
    • /
    • 2004
  • Through investing the criteria and evaluation for fire performance of interior components, this paper introduce the testing items and requirements for Flammability, Smoke density, and Toxicity properties of TTX(Tilting Train eXpress) interior parts. Next time, all trains including TTX will be occupied the components with superior fire-resistance and the sensing and monitoring system for fire in train.

  • PDF

Quantitative Difference in the Extinguishing Concentration of Inert Gases with Fire Suppression Criteria in a Cup Burner Test (컵버너시험에서 소화기준에 따른 불활성기체의 소화농도에 대한 정량적 차이)

  • Cho, Jae-Ho;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.34-42
    • /
    • 2014
  • The concentrations of inert gases ($N_2$, Ar, $CO_2$ and He) required to induce the flame instabilities such as swing, rotation, lifted and blow-out were measured in a cup burner nonpremixed flames for $CH_4$ and $C_3H_8$ fuels. Quantitative differences in the extinguishing concentration with fire suppression criteria (i.e. blow-out or onset of flame instability) were also examined. It was found that the difference in extinguishing concentration was increased with the appearance of lifted flame and the low extinguishing performance of inert gaseous. The maximum difference in extinguishing concentration with the suppression criteria was approximately 35% at the highest fuel velocity condition (1.3 cm/s) for the $C_3H_8$-air nonpremixed flame. It can be also expected that the extinguishing concentration by the criteria based on the onset of flame instability will provide the useful information from the viewpoint of the accurate and economical design concentration.

A Study on the Proposal of Amendment of Laws and Regulations on the Improvement of Defect Determination Criteria for Painting Work and the Establishment of Replacement Cycle for Fire door (도장공사 하자판정기준 개선 및 방화문 교체 주기 설정에 관한 법령 개정안 제안 연구)

  • Kim, Soo-Yeon;Kwon, Young-Jin;Kim, Yun-Seong;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.95-96
    • /
    • 2022
  • Based on the analysis of defects occurring before and after painting work, this study intends to derive a reasonable improvement in judgment criteria and propose an amendment to the relevant law through the establishment of a clear fire door replacement cycle in terms of fire safety.

  • PDF

Numerical Analysis of Heat Flow in Fire Compartment using SIMPLE Algorithm (SIMPLE Algorithm을 이용한 화재실의 열 유체의 수치해석)

  • 김광선;손봉세
    • Fire Science and Engineering
    • /
    • v.6 no.1
    • /
    • pp.17-22
    • /
    • 1992
  • We have derived the general transfer equation for governing the continuity, energy transfer, mass and momentum transfer, and turbulent energy dissipation rate within the fire compartment which has the 800t fire source at the center of the floor. The governing transfer equations have been descretized using the finite volume approach and numerically experimented under the SIMPLE algorithm. In order for the SIMPLE algorithm approach to be physically reliable, the test results are compared with those of Morita's SOR Method using Conjugate Residual Method and found to be close to physical values though the computational convergence time still remains to be upgraded. The treatment of source terms in the system of finite difference equations has been critical in order to converge the governing equations within the appropriate time steps. The criteria of convergence allowance for the whole domain have been checked and the sudden change of the non-linear effects from the source term have been avoided. The criteria has been allowed to be for 5$\times$10$^{-5}$ .

  • PDF

Optimization for Ventilation Capacity of Large Enclosure Considering Fire Load (화재하중을 고려한 대공간 제배연 용량 최적화 연구)

  • Ahn, Chan-Sol;Kim, A-Ram
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.478-481
    • /
    • 2011
  • This study is intended to evaluate and optimize the characteristics of smoke spreading and the appropriateness of evacuation time extended by operation of smoke control system during fire within the underground space of the building structured in compliance with the smoke control system performance criteria from the local fire safety standard, which has been currently applied to the buildings in Korea. Using the heat release per unit weight of the combustibles, a numerical analysis both in case of smoke control system in operation and the system not in operation was carried out at the several different shopping malls. From the viewpoint of securing the evacuation time, the results were compared in an attempt to assess the appropriateness of the fire safety criteria.

  • PDF

Study on Establishment of criteria for Heart Disease in Oriental Medicine (심병증 진단요건의 표준 설정을 위한 연구)

  • Choi Sun Mi;Park Kyung Mo;Jeung Chan Gil;Sung Hyun Jea;Ahn Kyoo Seok
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.4
    • /
    • pp.845-851
    • /
    • 2003
  • The objective is to establish the standard of criteria for differential diagnosis of signs and symptoms. This study selected signs and symptoms related to heart which stands for Fire(火) as a kind of five phase(五行). Eleven experts was asked to evaluate the adequateness of criteria which was developed by Korea Institute of Oriental Medicine(KIOM) and to suggest the amendment of them. To implement the study, we used the questionnaire which asks about the diagnosis criteria for an insufficiency of the heart-qi(心氣虛證), deficiency of the heart blood(心血氣證), deficiency of the heart-yin(心陰虛證), insufficiency of the heart-yang(心陽虛證), exuberant fire due to hyperactivity of the heart(心火亢盛證), stagnation of the heart blood(心血瘀阻證), heart disturbed by phlegm-fire(痰火擾心證), attack of the heart by retainedfluid(水氣凌心證). Every criteria consists of primary symptoms, secondary symptoms, tongue findings. and pulse findings. In perspectives of the classification of patterns for signs and symptoms and criteria for diagnosis, the result shows that the previous standard doesn't have so many problem. So many of experts were agree with the criteria which was suggested but the trend is that they use, in their actual practice, less than the criteria. Additionally, they pointed that every element in a criterion should have the different weight value, criteria for the overlapped pattern should be added, and, in future, criteria which are based on clinical investigation should be established.