• Title/Summary/Keyword: fire condition

검색결과 819건 처리시간 0.021초

기후조건 변화에 따른 산불확산 변화 비교 (Comparison a Forest Fire Spread variation according to weather condition change)

  • 이시영;박흥석
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.490-494
    • /
    • 2008
  • We simulated a forest fire which was occurred in Yangyang area on 2005 and compared a results between two different weather conditions(real weather condition and mean weather condition since 1968) using FARSITE, which is a forest fire spread simulator for preventing and predicting fire in USDA. And, we researched a problem in the transition for introducing, so we serve the basic method for prevention and attacking fire. In the result, severe weather condition on 2005 effected a forest fire behavior. The rate of spread under real weather condition was about 4 times faster than mean weather condition. Damaged area was about 10 time than mean weather condition. Therefore, Climate change will make a more sever fire season. As we will encounter to need for accurate prediction in near future, it will be necessary to predict a forest fire linked with future wether and fuel condition.

  • PDF

전기히터의 화재위험성에 관한 실험연구 (An Experimental Study on the Fire Hazards in Electric Heater)

  • 홍성호;이복영;박상태;유현종
    • 한국안전학회지
    • /
    • 제22권2호
    • /
    • pp.36-40
    • /
    • 2007
  • This study presents on the analysis fire hazards of electric heater. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate normal condition and abnormal condition. The abnormal condition experiment is simulated in which combustibles are placed near by electric heater. Vertical burning test(UL 94) is conducted for the fire retardant experiment. The results show that fire hazard is high in case of abnormal condition. And Material of electric heater has not fire retardant performance. In this paper, we suggest to add temperature fuse in electric heater for reducing fire hazard.

드럼세탁기 화재안전성 확보를 위한 실험연구 (A Experimental Study on the Fire Safety of Drum-type Electric Washing Machine)

  • 홍성호;이상현;박상태;유현종;전웅재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.131-133
    • /
    • 2008
  • This study presents on the analysis fire hazards of drum type electric washing machine. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate under the normal condition and abnormal condition. The experiment under the abnormal condition is simulated in safety device failure, situation of accumulated dust and tracking phenomenon caused by humidity. The results show that fire hazard is high at the abnormal condition. In this paper, we suggest to use the safety device of low operating temperature in electric washing machine for reducing fire hazard.

  • PDF

일정축력을 받는 콘크리트 충전 각형기둥의 경계조건 변화에 따른 화재거동특성에 관한 실험적 연구 (An Experimental Study on the Fire Behavior of CFT Column under the Constant Axial Loading Condition in Fire)

  • 김형준;김흥열;민병렬;권인규;권기혁
    • 한국화재소방학회논문지
    • /
    • 제24권6호
    • /
    • pp.69-75
    • /
    • 2010
  • 콘크리트가 충전된 각형강관 기둥(CFT)은 외부에 강재가 노출된 형상으로 외측의 강관은 화재시 급격한 온도상승으로 인해 강도가 저하되나, 내부의 콘크리트는 열용량이 큰 재료로써 내화성능을 확보할 수 있는 구조로 구성되어 있다. CFT 기둥을 내화구조로서 적용하기 위해서는 구조적 성능에 영향을 미치는 인자에 대한 연구가 필요하며, 이에 대한 조건별 영향성에 관한 연구가 필요하다. 내화성능에 영향을 주는 주요인자는 콘크리트 압축강도.단면크기.축력비.경계조건이며, 그 중 기둥과 보의 경계조건은 구조적 측면에서 하중지지능력에 영향을 미치므로 내화성능을 지배하는 주요 인자 중에 하나이다. 실험결과 360단면에서는 양단 고정조건에서는 106분의 내화성능이 확보되나 양단 힌지 조건에서는 89분의 내화성능을 확보하는 것으로 나타났다. 280단면에서는 양단 고정조건에서는 113분의 내화성능이 확보되나 양단힌지 조건에서는 78분의 내화성능을 확보하였다.

CFT기둥 재하가열 실험에서의 경계조건에 따른 내화성능 영향에 관한 실험적 연구 (An Experimental Study about Fire Resistance effect on Boundary Condition of CFT Column under Loading in Fire)

  • 김형준;김흥열;박경훈;조경숙;권인규
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 춘계학술논문발표회 논문집
    • /
    • pp.389-394
    • /
    • 2010
  • A concrete filled square steel tube (CFT) is composed of the external steel material, which its strength is reduced in fire due to sudden temperature increase, and the internal concrete with high thermal capacity that can ensure the fire resistance performance of the structure. Therefore, research about the influence factors of the structural performance of CFT column is required in order to apply CFT column to a fire resisting structure, and additional research about influence for each condition is also necessary. Among the influence factors, the boundary condition between column and beam is important structurally, and it is one of the major factors that determine overall fire resisting performance. This study performed a fire experiment under loading in order to analyse the influences of CFT column to the boundary condition. As the results of the experiment, fire resistance time of 106 minutes was ensured for the clamped-end condition but 89 minutes for the hinge-end condition in case of the 360 cross section. And, fire resistance time of 113 minutes was ensured for the clamped-end condition but 78 minutes for the hinge-end condition in case of the 280 cross section. The difference in the fire resistance performance according to changes in the boundary conditions showed a tendency that larger change effect on the fire resistance performance was derived from smaller cross section area.

  • PDF

건조일체형 드럼세탁기의 화재위험성에 관한 실험연구 (A Experimental Study on the Fire Hazards in Drum-Type Electric Washing Machine)

  • 홍성호
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.328-331
    • /
    • 2008
  • This study presents on the analysis fire hazards of drum type electric washing machine. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate under the normal condition and abnormal condition. The experiment under the abnormal condition is simulated in safety device failure, situation of accumulated dust and tracking phenomenon caused by humidity. The results show that fire hazard is high at the abnormal condition. In this paper, we suggest to use the safety device of low operating temperature in electric washing machine for reducing fire hazard.

환기량 조건이 열차 화재 성장에 미치는 영향성에 대한 FDS 화재 시뮬레이션 (Numerical study of the Effect of Ventilation Condition on Rolling Stock Fire Growth through the FDS Simulation)

  • 양성진;이창덕;오지은;강찬용
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.124-132
    • /
    • 2010
  • To predict and analyze the rolling stock's fire growth is considered not only important factor in estimating hazard analysis of rolling stock, but also a primary factor in aspect of a rail load facility. Because it's could be regarded as a ignition source in risk assesment for the facility i.e. tunnel and station. However, currently, standardized method to predict and analyze the fire growth has not been completed yet. it is due to the fact that fire growth is not only depended on thermal property of interior materials, but also is affected dominantly by various factors such as ignition source (characterized by location, duration, and intensity), train running condition and in/exterior ventilation condition. Especially, ventilation condition is one of the most effective factor to affect fire growth in compartment space as noticed by under-ventilation fire condition. In this study, the effect of each ventilation condition on fire growth and load were examined through the numerical method through FDS (Fire Dynamics Simulator).

  • PDF

국가지정 목조문화재의 소방대책에 관한 실태조사 (The Study for Fire Prevention of Main Wooden Cultural Properties of Korea)

  • 백민호;이지향
    • 한국화재소방학회논문지
    • /
    • 제24권3호
    • /
    • pp.1-8
    • /
    • 2010
  • 본 연구에서는 문화재청에서 지정한 123개 목조문화재를 대상으로 소방대책을 고려한 실태조사 및 분석을 다음과 같이 실시하였다. 첫째 우리나라 목조문화재의 관리 및 원인별 화재발생현황을 조사하여 정리하였다. 둘째, 123개의 중요목조문화재에 대하여 2008년 8월부터 10월까지 현장조사 및 유관기관 자료조사를 실시하여 문화재의 지정구분, 소재지구분, 해당건축면적, 보유문화재수, 소방시설현황, 소방차의 진입방향, 자위소방대 인원, 방화관리자 선임여부, 소방서와의 거리 및 소요시간 등의 소방대책 마련에 필요한 내용들을 조사 분석하여 중요목조문화재의 기본현황을 정리하였다. 셋째, 위의 조사 자료를 기본으로 123개 중요목조문화재의 화재발생을 고려한 위험도를 살펴보고자 문화재의 내부적 현황과 외부적 현황으로 구분하여 평균지수에 의해 분석하고 우리나라 중요목조문화재의 소방대책수립을 위한 기초자료를 정리하였다.

산불교육실태 및 개선방안에 관한 연구 (A Study on the Actual Education Condition and Improvement of Education Program about Forest Fire)

  • 이시영
    • 한국화재소방학회논문지
    • /
    • 제24권6호
    • /
    • pp.13-19
    • /
    • 2010
  • 본 연구에서는 강원도 등 총 8개 기관의 산불관련 부서에 대하여 산림인력개발원의 산불교육훈련에 대한 설문조사를 통해 산불교육과정, 희망교과목, 산불방지종합훈련장 개편내용 등을 분석하여 국.내외 산림환경의 변화와 산불방지 정책에 능동적으로 대처하고, 산불담당자의 업무효율성 및 역량증대를 위한 산불교육훈련 개선 방안을 제시하였다.

방화(放火)화재 특성에 관한 실험적 연구 (A Experimental Study on the Arson Fire Characteristics)

  • 최진;권오승;강경식
    • 대한안전경영과학회지
    • /
    • 제10권2호
    • /
    • pp.1-13
    • /
    • 2008
  • This Study is to analyze the characteristics of arson fire under fire dynamics to protect people and property from arson fire which has been radically increased with the development of the Korean economy. Assembly and merchandise purposes such as theater, retail, and exhibition has been performed as the arson fire study. The experiment for this study is based on the analysis of the characteristic for its own combustion process and smoke spread when arson fire occurs. This study presents the analysis through comparing the condition of setting fire using liquid fuel such as thinner on purpose to the condition of setting fire naturally depending on each occupancy.