• Title/Summary/Keyword: fire cases

Search Result 583, Processing Time 0.023 seconds

Detection of Current Signal and Thermal Characteristics of Electric Fan Operated in Various Situations (선풍기의 운전 상황별 발열특성 및 전류신호 검출)

  • Kim, Doo-Hyun;Lee, Heung-Su
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.20-27
    • /
    • 2014
  • Cooling equipment is the frequent occurrence of fire despite the absence of the heating element. National fire statistics in 2013 show that a total of 263 fires occurred in the cooling equipment and the number of electric fan has 145 fire cases. This is accounted for 55.1% of the whole. Electric fan is the electrical appliance that the heat is generated on the winding wire and the iron core. If such characteristic is not controled properly, fire would break out at the electric fan. also there is a gap filled with an insulator between connection terminals of the capacitor in the electric fan. But in case that the gap on the capacitor is covered with some conductive material such as dust, there would be a fire as well caused by electrical heating locally. Although many studies related with those have been conducted, electric fan fire is continuously occurred. In this study, thermal characteristics and current signal in various conditions such as the heat generation of windings including iron cores of the motor and the dielectric breakdown of terminals on the capacitor connected to the motor were detected. In order to measure the maximum temperature, "third level" wind velocity button was pushed and the time selection switch to "continuation" was set. Analyzed data would be available for the fire safety of the electric fan.

Identifying Hazard of Fire Accidents in Domestic Manufacturing Industry Using Data Analytics (국내 제조업 화재사고 데이터 분석을 통한 복합 유해·위험요인 확인)

  • Kyung Min Kim;Yongyoon Suh;Jong Bin Lee;Seong Rok Chang
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.4
    • /
    • pp.23-31
    • /
    • 2023
  • Revising the Occupational Safety and Health Act led to enacting and revising related laws and systems, such as placing fire observers in hot workplaces. However, the operating standards in such cases are still ambiguous. Although fire accidents occur through multiple and multi-step factors, the hazards of fire accidents have been identified in this study as individual rather than interrelated factors. The aim has been to identify multiple factors of accidents, outlining fire and explosion accidents that recently occurred in the domestic manufacturing industry. First, major keywords were extracted through text mining. Then representative accident types were derived by combining the main keywords through the co-word network analysis to identify the hazards and their relationships. The representative fire accidents were identified as six types, and their major hazards were then addressed for improving safety measures using the identification of hazards in the "Risk Assessment" tool. It is found that various safety measures, such as professional fire observers' training and clear placement standards, are needed. This study will provide useful basic data for revising practical laws and guidelines for fire accident prevention, system supplementation, safety policy establishment, and future related research.

Simplified robustness assessment of steel framed structures under fire-induced column failure

  • Jiang, Binhui;Li, Guo-Qiang;Yam, Michael C.H.
    • Steel and Composite Structures
    • /
    • v.35 no.2
    • /
    • pp.199-213
    • /
    • 2020
  • This paper proposes a Global-Local Analysis Method (GLAM) to assess the progressive collapse of steel framed structures under fire-induced column failure. GLAM obtains the overall structural response by combining dynamic analysis of the heated column (local) with static analysis of the overall structure (global). Test results of two steel frames which explicitly consider the dynamic effect during fire-induced column failure were employed to validate the proposed GLAM. Results show that GLAM gives reasonable predictions to the test frames in terms of both whether to collapse and the displacement verse temperature curves. Besides, several case studies of a two-dimensional (2D) steel frame and a three-dimensional (3D) steel frame with concrete slabs were conducted by using GLAM. Results show that GLAM gives the same collapse predictions to the studied cases with nonlinear dynamic analysis of the whole structure model. Compared with nonlinear dynamic analysis of the whole structure model, GLAM saves approximately 70% and 99% CPU time for the cases of 2D and 3D steel frame, respectively. Results also show that the load level of a structure has notable effects on the restraint condition of a heated column in the structure.

The Proposition of Domestic Sprinklers Installation Standard and the Fire Services Act (국내 스프링클러 설치기준과 소방관련 법에 관한 고찰)

  • Kim, Yong-Moon;Lee, Young-Jai
    • Journal of Korean Society of Disaster and Security
    • /
    • v.7 no.2
    • /
    • pp.17-24
    • /
    • 2014
  • Recently, many accidents occur frequently because sprinklers aren't installed or don't work right when there are outbreak of fire in houses and aggregate buildings. Therefore, they can result in damage for humans and loss of property. Sprinklers are the most appropriate which can extinguish buildings' fire in the initial stages. Through lack of legal system, in domestic cases, sprinklers cannot operate their inherent performance. Domestic standard simply classifies installation objects according to types of business and forms of buildings, also divides into uses and floors of buildings. Especially it only regulates that sprinklers must be installed every floors in particular fire buildings that have more than eleven floors. While it doesn't need to install sprinklers below ten floors, so we are threatened the safety. In this study, we derived causes and implications by analyzing concepts of sprinklers facilities, installation standards in domestic and foreign legal system, and recent cases that expanded damages in fire accidents because of weak point of installation and control standards. In domestic cases, as a result, government has to provide an institutional strategy and law that regulate duty to install sprinklers to all aggregate buildings regardless of floors in terms of new buildings. Also, if someone who has existing buildings wanted to install them, government would guarantee subsidy to encourage installation. In addition, government supervises fire-fighting activities when there are fire by compensating standards about regular inspection by a qualified technician, operation and maintenance of sprinklers as well as reinforcement of administrative criteria.

A Study on the Measures for Activating the Fire Fighting Safety Education of Elementary School Students - Focusing on the Fire Fighting Science Class of Gyeonggi-do Goyang Fire Station - (초등학생 소방안전교육의 활성화 방안에 관한 연구 - 경기도 고양소방서 소방과학교실을 중심으로 -)

  • Hyun, Seong-Ho;Cha, Jeong-Min;Song, Yun-Suk;Park, Kyung-Hyo
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.67-77
    • /
    • 2009
  • The purpose of this study is to deal with fire fighting safety education primarily among the fields of child safety education. So, first of all, this study considered the theoretical background of fire fighting safety education. And this study analyzed the present state and cases of safety accidents in elementary schools. And by focusing on the fire fighting science class for elementary schools which Gyeonggi-do Goyang fire station is executing now, this study analyzed the educational outline, present state, educational goal, and content of fire fighting science class, and conducted the satisfaction survey through questionnaire over the elementary school students participating in fire fighting science class and the fire fighting officers in charge of fire fighting science class. On basis of this research, by developing the new field of fire fighting education and publicity into the program which can diffuse the fire fighting-related chemical experiment based on the science of chemistry and physics in the future and so provide the pleasure and surprise of experiencing directly not only natural fire fighting education and publicity but also learning and the common sense of fire fighting, this study tried to present the alternatives about the measures for activating the fire fighting safety education in elementary schools.

A Study on the Test and Installation Standards of the Video Fire Detector (영상화재감지기 시험과 설치기준에 관한 연구)

  • Lee, Jeong-Hyun;Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.1-5
    • /
    • 2016
  • This research performed tests of Video Fire Detector and criteria of installation to make suggestions regarding the criteria that must be reflected in NFSC 203 by comparing the standards of FM Approvals, UL, ISO7240 and NFPA 72. FM Standard related to Video Fire Detector test has been classified as Smoke, Flame type, but the UL Standard has classified only as a Smoke type. This research examined 6 cases of fire phenomenon detection case in ISO 7240 and 3 cases in NFPA 72, respectively. There are 15 items required for the installation standard of a Video Fire Detector and each field standard is presented as a per installation method. To apply a Video Fire Detector, the pertinent items (the definition of term, detector's classification, structure and function among its test item) must be inserted. In addition, 7 items of the fire test, i.e., the sensitivity adjustment, prevent false alarm, ambient temperature test, the effective sensitivity and detection distance and viewing angle, aging test, flood test, must be applied to the actual test. For installation in the field, the operation environment and levels of illumination, and NFSC 203 must be set, and standards relevant to the sound system, indicators' installation distance, etc. need to be inserted.

A Study on the Problems and Character for Management of Fire Prevention at the Wholesale Markets (도매시장 화재안전관리 측면에서의 특성 및 취약요소에 관한 연구)

  • Park, Jae-Sung;Im, Jae-Keun
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.150-158
    • /
    • 2010
  • There are lots of buildings with their deterioration in wholesale markets which have high concentration that can cause big fire due to difficulty of installing fire protection system in fire compartment, absence of safety awareness, access by many and unspecified people. There had been big fire that caused by these kind of fire weakness such as Seomun Market's in 2005 which costed tens of millions dollar, Dongmun Shopping District’s with 7 casualties. Now counter-measure against these fire is urgently needed. This study drew characteristic of current condition of wholesale markets and the one classified by main agent, fire cases and prevention of fire through statistical data. Also, current condition of fire prevention management and actual state were investigated by conducting a survey of person in charge of fire prevention and current practician. As a result, it was shown that securing professionalism of fire prevention, improvement of structural weakness of buildings, obtaining reliability on performance of fire protection system and internal fire education against practician in the market are needed.

A Study on Development of Fire Accident Analysis System Using Classification Model and Database (화재사고 분류모델 및 데이터베이스를 이용한 화재사고 분석시스템 구축에 관한 연구)

  • Kim In-Tae;Heo Jaeseok;Song Hee-Oeul;Ko Jae-Wook;Kim In-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.90-98
    • /
    • 1998
  • In order to establish detailed plans for fire protection and reduce the possible fire accidents in the future, collection of domestic and foreign fire accident cases and fundamental analysis are very important. In this study the classification model for fire accidents was developed and the direction to a new model was suggested by comparison ours with the accidents classification model of NFPA of United States of America and Japan. A new developed PC-based database program for fire accidents (FADBS) was used to analyse fire accidents easily and efficiently.

  • PDF

The Heating of Cu-oxide and Arc Properties according to Electrical Poor Contact (전기적 불완전 접촉에 따른 동산화물의 발열 및 아크 특성)

  • Kim, Wansu;Park, SangJune;Hwang, DongHyun
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.15-20
    • /
    • 2019
  • As industry is progressing and standards of living are improved, the demand of electrical energy is expected to grow 8-9% annually. Therefore, the importance of electrical fire prevention technology with the ability of the power supply is being emphasized. According to the statistics of fire in Korea, fire occurred about 45,000 cases annually, and electrical fire possessed about 20%. The electrical fire by poor contact has increased gradually, can be connected as great fire to secondarily induce short circuit and earth fault. Then analysis of heating causes of electrical connections between copper and copper alloy is needed. Also, detection and analysis algorithm of oxide at copper alloy are necessary. In this research, in order to understand the characteristics of oxide growth with rising resistance and heating, it is demonstrated that the oxide at electrical connections can cause fire due to arcing.

A Case Report of ROSC for Out-of Hospital Cardiopulmonary Resuscitation: Based on one Area Heart Saver (병원 전 심폐소생술에 의한 자발순환 회복 8례: 일 지역 하트세이버 수여자를 기준으로)

  • Bang, Sung-Hwan;Kim, Jee-Hee;Kim, Gyoung-Youg;Roh, Sang-Gyun
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.61-67
    • /
    • 2013
  • This study was to investigate the cardiopulmonary resuscitation (CPR) outcomes and the clinical characteristics of outof- hospital cardiac arrest (OHCA) by analyzing date in one region. A total 8 patients, survived over 72 hours after ROSC. The cardiac arrest were caused by unknown (5 cases), cardiac disease (3 cases). The most common place of cardiac arrest was in the home (6 cases), witnessed cardiac arrest (8 cases), cardiopulmonary resuscitation by bystander was performed (4 cases), agonal respiration (3 cases). The initial electrocardiogram (ECG) showed ventricular fibrillation (VF) in 7 cases, pulseless electrical activity (PEA) other rhythms in 1 cases. Average time from call to scene arrival 6.1 minutes, call to hospital arrival 23.0 minutes, duration of total CPR was 8.7 minutes. The certificate of them were level 1 emergency medical technician (EMT) 6 cases, level 2 EMT 3 cases, total 3 members 7 cases. To improve the rate of survival for out-ofhospital cardiac arrest victims, development of continuous CPR educational program for lay rescue.