• Title/Summary/Keyword: fire/explosion prevention

Search Result 92, Processing Time 0.029 seconds

Acetylene Black의 분진폭발 특성 연구 (Study on Dust Explosion Characteristics of Acetylene Black)

  • 최재준;하동명
    • 한국안전학회지
    • /
    • 제39권2호
    • /
    • pp.38-43
    • /
    • 2024
  • Recently, with the expanding market for electronic devices and electric vehicles, secondary battery usage has been on the rise. Lithium-ion batteries are particularly popular due to their fast charging times and lightweight nature compared to other types of batteries. A secondary battery consists of four components: anode, cathode, electrolyte, and separator. Generally, the positive and negative electrode materials of secondary batteries are composed of an active material, a binder, and a conductive material. Acetylene Black (AB) is utilized to enhance conductivity between active material particles or metal dust collectors, preventing the binder from acting as an insulator. However, when recycling waste batteries that have been subject to high usage, there is a risk of fire and explosion accidents, as accurately identifying the characteristics of Acetylene Black dust proves to be challenging. In this study, the lower explosion limit for Acetylene Black dust with an average particle size of 0.042 ㎛ was determined to be 153.64 mg/L using a Hartmann-type dust explosion device. Notably, the dust did not explode at values below 168 mg, rendering the lower explosion limit calculation unfeasible. Analysis of explosion delay times with varying electrode gaps revealed the shortest delay time at 3 mm, with a noticeable increase in delay times for gaps of 4 mm or greater. The findings offer fundamental data for fire and explosion prevention measures in Acetylene Black waste recycling processes via a predictive model for lower explosion limits and ignition delay time.

페놀의 연소특성치의 측정 및 예측 (Measurement and Prediction of Combustion Properties of n-Phenol)

  • 하동명
    • 한국위험물학회지
    • /
    • 제6권2호
    • /
    • pp.23-29
    • /
    • 2018
  • The fire and explosion properties necessary for waste, safe storage, transport, process design and operation of handling flammable substances are lower explosion limits(LEL), upper explosion limits(UEL), flash point, AIT( minimum autoignition temperature or spontaneous ignition temperature), fire point etc., An accurate knowledge of the combustion properties is important in developing appropriate prevention and control measures fire and explosion protection in chemical plants. In order to know the accuracy of data in MSDSs(material safety data sheets), the flash point of phenol was measured by Setaflash, Pensky-Martens, Tag, and Cleveland testers. And the AIT of phenol was measured by ASTM 659E apparatus. The explosion limits of phenol was investigated in the reference data. The flash point of phenol by using Setaflash and Pensky-Martens closed-cup testers were experimented at $75^{\circ}C$ and $81^{\circ}C$, respectively. The flash points of phenol by Tag and Cleveland open cup testers were experimented at $82^{\circ}C$ and $89^{\circ}C$, respectively. The AIT of phenol was experimented at $589^{\circ}C$. The LEL and UEL calculated by using Setaflash lower and upper flash point value were calculated as 1.36vol% and 8.67vol%, respectively. By using the relationship between the spontaneous ignition temperature and the ignition delay time proposed, it is possible to predict the ignition delay time at different temperatures in the handling process of phenol.

용접·용단 작업 중 사고 예방을 위한 제도 개선 연구 (A Study on the Improvement of System to Prevent Accidents during Welding and Melting Operations)

  • 한경수;조규선;김영세;김병직;박주영;박교식
    • 한국가스학회지
    • /
    • 제24권1호
    • /
    • pp.76-81
    • /
    • 2020
  • 최근 가연물이 있는 장소에서 용접·용단 작업 중 불꽃 비산 등으로 인한 화재·폭발사고가 빈발하고 있으며, 이러한 화재사고의 원인은 위험물 제거, 불꽃 비산방지 조치 등 기본적인 안전수칙 미준수가 대부분으로 산업안전보건법의 제도적인 보완이 필요하다. 본 연구에서는 국내 용접·용단 작업 등 화기작업에서의 화재·폭발 사고를 시스템적 관점에서 분석하고 그 결과를 반영하여 화재감시자 배치 확대, 화재위험작업의 사전승인, 화재예방 안전교육 강화 등 제도개선방안을 제안하였다.

열매체유 시스템의 안전관리 실태에 관한 연구 (A Study on the Actual Conditions of Safety Management in Thermal Oil System)

  • 이주엽;이근원;우인성
    • 한국안전학회지
    • /
    • 제29권5호
    • /
    • pp.60-66
    • /
    • 2014
  • Depending on the progress of the industrial advances, the use of the thermal oil system in the utility system has been increased, which became an important part in the operation of the plant. However, fire or explosion have occurred due to lack of risk awareness and safety management, more frequently than we know. In this study, by using a questionnaire, actual conditions of safety management in thermal oil system is surveyed and analyzed, it is composed of general, a safety status of the thermal oil system component and the stage of recognition and management in the thermal oil system. These results of this study can be used as basic data to the safety management and the accident prevention of fire or explosion in the workplace.

인화성 액체 도전율에 관한 측정 및 비교(IEC 60079-32-2) 연구 (A Study on the Measurement and Comparison(IEC 60079-32-2) of Flammable Liquid Conductivity)

  • 이동훈;변정환
    • 한국안전학회지
    • /
    • 제34권4호
    • /
    • pp.22-31
    • /
    • 2019
  • The flammable liquid conductivity is an important factor in determining the generation of electrostatic in fire and explosion hazardous areas, so it is necessary to study the physical properties of flammable liquids. In particular, the relevant liquid conductivity in the process of handling flammable liquids in relation to the risk assessment and risk control in fire and explosion hazard areas, such as chemical plants, is classified as a main evaluation item according to the IEC standard, and it is necessary to have flammable liquid conductivity measuring devices and related data are required depending on the handling conditions of the material, such as temperature and mixing ratio for preventing the fire and explosion related to electrostatic. In addition, IEC 60079-32-2 [Explosive Atmospheres-Part 32-2 (Electrostatic hazards-Tests)] refers to the measuring device standard and the conductivity of a single substance. It was concluded that there is no measurement data according to the handling conditions such as mixing ratio of flammable liquid and temperature together with the use and measurement examples. We have developed the measurement reliability by improving the structure, material and measurement method of measuring device by referring to the IEC standard. We have developed a measurement device that is developed and manufactured by itself. The test results of flammable liquid conductivity measurement and the data of the NFPA 77 (Recommended Practice on Static Electricity) Annex B Table B.2 Static Electric Characteristic of Liquids were compared and verified by conducting the conductivity measurement of the flammable liquid handled in the fire and explosion hazardous place by using Measuring / Data Acquisition / Processing / PC Communication. It will contribute to the prevention of static electricity related disaster by taking preliminary measures for fire and explosion prevention by providing technical guidance for static electricity risk assessment and risk control through flammable liquid conductivity measurement experiment. In addition, based on the experimental results, it is possible to create a big data base by constructing electrostatic physical characteristic data of flammable liquids by process and material. Also, it is analyzed that it will contribute to the foundation composition for adding the specific information of conductivity of flammable liquid to the physical and chemical characteristics of MSDS.

공장건물의 화재리스크 경감방안에 관한 연구 (A Study on Factory Building Fire Risk Reduction Management)

  • 정의수;강경식
    • 대한안전경영과학회지
    • /
    • 제10권3호
    • /
    • pp.43-53
    • /
    • 2008
  • This study is carried out for the fire safety of the factory building, the fire risk reduction measure in compliance with an example approached in fire risk reduction systematically, contribute to reduce the fire risk. The analytical fire risk process of discovering, identifying, estimating and evaluating risk and control measure as risk reduction measures are core concept, applies loss prevention with loss control techniques. The painting process in the workplace where the fire hazard and death accident accompanies coexists. Loss prevention problem of creation prevention of dangerous atmosphere at workplace is health and human services problem of normal circumstances, must be inspected with problem of combustible gases at the time of fire explosion. Static electricity measure accomplished the risk control process thoroughly as the fire risk reduction process model with the ignition sources measure which is presented. Fire risk from within organizing will be able to classify with each field by detailedly but risk treatment process will be able to apply basically all the same concept. Consequently about risk management example from before, this study is proposed risk management techniques that standardized rightly in the actual condition of organization with one plan, with discovery of fire risk, the feedback process in compliance with a fire risk reduction and the review which control the result is joint responsibility of engineer, technical expert and manager as part of safety management to practice with the fact must be supervised.

지하공간의 위험성 평가수법에 관한 연구 -지하가 화재, 폭발 방재 대책 중심으로- (A Study on the Risk Assessment Technique of the Underground Space -Focused on Prevention Policy of Fire and Explosion-)

  • 박종근;노삼규
    • 한국화재소방학회논문지
    • /
    • 제15권4호
    • /
    • pp.64-70
    • /
    • 2001
  • 지하공간 중 지하가의 사고 ,사례와 문헌 연구 및 실태를 조사, 검토하고, 운영, 관리 단계에서 위험요인을 추출하여 화재 폭발 안전대책의 평가요소 및 위험성 평가수법을 제시하고자 한다. 또한, 지하가의 대규모화, 심층화, 복합화에 대한특성 항목을 분류하고 7가지 대책의 중요도를 제시하여 지하가 계획단계의 지표로 삼고자 한다.

  • PDF

재해분석을 통한 정전기 안전관리 수준 향상 방안 연구 (A Study on the Improvement Plan of Electrostatic Safety Management Level through Injury Analysis)

  • 최상원;정성춘;박재석;양정열;변정환
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.37-45
    • /
    • 2019
  • The characteristic of fire and explosion related to electrostatic discharge is that it is difficult to reproduce the electrostatic charge and discharge phenomenon in addition to the large human and material damage. Therefore, in order to prevent accidents and disasters related to electrostatic in fire and explosion hazard areas, it is important to manage the level of electrostatic in a safe manner from the perspective of system between industrial facilities and human bodies. Rule 325 of the Occupational Safety and Health Regulations, "Prevention of Fire / Explosion due to Electrostatic", requires the use of grounding, conductive materials, humidification and electrification in order to prevent the risk of disaster caused by static explosion and electrostatic in the production process. In order to comply with these measures, related technologies, standards and systems are needed from the viewpoint of preventive measures related to electrostatic in fire and explosion hazard areas, but in Korea, it is still insufficient. Therefore, technical, institutional and managerial measures are needed as a precautionary measure to improve the level of ESD safety in fire and explosion hazard areas and prevent electrostatic related injury. In Korea, we analyzed the current status and characteristics of electrostatic related disaster by using the statistics of industrial accident and fire statistics of the Ministry of Employment and Labor. We also analyzed the current status and characteristics of electrostatic related disasters in Japan using JNIOSH accidents and disasters investigation cases and JNIOSH fire accident data of Japan Fire Bureau. The purpose of this study is to compare and analyze the current status of electrostatic related accidents and disasters in Korea and Japan in order to improve the safety management of electrostatic in fire and explosion hazard areas. In order to prevent accidents and disasters in the industrial field, The technical, institutional, and managerial measures to manage the level of electrostatic in a safe state were derived from the system point of view.