• 제목/요약/키워드: finite type

검색결과 3,378건 처리시간 0.022초

유압 베인 펌프의 캠 링 변형에 관한 연구 (A Study on the Cam Ring Deformation in a Balanced Type Vane Pump)

  • 한동철;조명래;양광식;박제승
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제27회 춘계학술대회
    • /
    • pp.206-211
    • /
    • 1998
  • This paper presents the deformation characteristics of cam ring in a balanced type vane pump. Cam ring is operated in the condition of high pressure. Therefore the local deformation of cam ring affects the characteristics of compression, vane motion and noise and vibration. We analyzed the deformation of cam ring in three types by using the finite element method. As results of analysis, deformed shape of cam ring and the effects of deformation on the compression are presented.

  • PDF

CONVERGENCE THEOREMS OF MIXED TYPE IMPLICIT ITERATION FOR NONLINEAR MAPPINGS IN CONVEX METRIC SPACES

  • Kyung Soo, Kim
    • Nonlinear Functional Analysis and Applications
    • /
    • 제27권4호
    • /
    • pp.903-920
    • /
    • 2022
  • In this paper, we propose and study an implicit iteration process for a finite family of total asymptotically quasi-nonexpansive mappings and a finite family of asymptotically quasi-nonexpansive mappings in the intermediate sense in convex metric spaces and establish some strong convergence results. Also, we give some applications of our result in the setting of convex metric spaces. The results of this paper are generalizations, extensions and improvements of several corresponding results.

유한요소 해석을 이용한 정형용 흉·요추 보조기의 형태에 따른 생체역학적 분석 (Biomechanical Analysis of Different Thoracolumbar Orthosis Designs using Finite Element Method)

  • 김영현;전성철;정덕영;이성재
    • 재활복지공학회논문지
    • /
    • 제6권1호
    • /
    • pp.45-50
    • /
    • 2012
  • 흉 요추 보조기는 후만증 관련 증상의 진행을 예방하고 통증을 완화시키기 위한 목적으로 노인성 후만증 환자의 재활을 위하여 이용되고 있다. 최근 다양한 형태의 흉 요추 보조기가 개발되고 있으나 생체역학적 효과에 관한 연구가 미흡한 실정이다. 따라서 본 연구에서는 세 가지 형태 (Type 1, one-connecting frame type; Type 2, two-connecting frame type; Type 3, all-in-one type)의 흉 요추 보조기와 몸통 (trunk)의 유한요소 모델을 구현하여 보조기 착용 후 운동성 변화에 따른 몸통에서의 압력 분포 및 보조기의 응력을 비교 분석하였다. 신전 운동 시 몸통에서 확인되는 압력의 분산은 일체형의 형태를 가지는 Type 3에 의해서 가장 고르게 이루어졌으며 connecting frame 형태의 Type 1과 Type 2의 압력 분포 패턴은 크게 차이가 나지 않았다. 보조기 착용에 따른 몸통의 운동성은 Type 2 ($11.3{\sim}13.9^{\circ}$), Type 1 ($12.1{\sim}15.4^{\circ}$)와 비교하여 Type 3 ($8.5{\sim}9.4^{\circ}$)에 의하여 가장 크게 제한되었다. 모든 Type의 보조기는 20% 미만의 파단 가능성을 보였다. 따라서, 보조기 착용에 따른 등압 분포 및 운동성의 결과로 미루어 볼 때, 일체형의 흉 요추 보조기가 후만증 환자 재활에 있어 높은 효과를 제공할 것으로 사료된다.

  • PDF

배관시스템 해석을 위한 벨로우즈 유한요소의 개발 (Development of a Bellows Finite Element for the Analysis of Piping System)

  • 고병갑;박경진;이완익
    • 대한기계학회논문집
    • /
    • 제19권6호
    • /
    • pp.1439-1450
    • /
    • 1995
  • Bellows is a familiar component in piping systems as it provides a relatively simple means of absorbing thermal expansion and providing system flexibility. In routine piping flexibility analysis by finite element methods, bellows is usually considered to be straight pipe runs modified by an appropriate flexibility factor; maximum stresses are evaluated using a corresponding stress concentration factor. The aim of this study is to develop a bellows finite element, which similarly includes more complex shell type deformation patterns. This element also does not require flexibility or stress factors, but evaluates more detailed deformation and stress patterns. The proposed bellows element is a 3-D, 2-noded line element, with three degrees of freedom per node and no bending. It is formulated by including additional 'internal' degrees of freedom to account for the deformation of the bellows corrugation; specifically a quarter toroidal section of the bellows, loaded by axial force, is considered and the shell type deformation of this is include by way of an approximating trigonometric series. The stiffness of each half bellows section may be found by minimising the potential energy of the section for a chosen deformation shape function. An experiment on the flexibility is performed to verify the reliability for bellows finite element.

ON ROTATION SURFACES IN THE MINKOWSKI 3-DIMENSIONAL SPACE WITH POINTWISE 1-TYPE GAUSS MAP

  • Athoumane Niang
    • 대한수학회지
    • /
    • 제41권6호
    • /
    • pp.1007-1021
    • /
    • 2004
  • In this paper, we study rotation surfaces in the Minkowski 3-dimensional space with pointwise 1-type Gauss map and obtain by the use of the concept of pointwise finite type Gauss map, a characterization theorem concerning rotation surfaces and constancy of the mean curvature of certain open subsets on these surfaces.

복합 열전달 해석에서 유한요소 해와 Ansys-Fluent 해의 비교 (COMPARISON OF FINITE ELEMENT SOLUTIONS WITH THOSE OF ANSYS-FLUENT IN A CONJUGATE HEAT TRANSFER PROBLEM)

  • 전병진;최형권;이동현;하종백
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.86-87
    • /
    • 2011
  • In this paper, a conjugate heat transfer around cylinder with heat generation was investigated. Both forced convection and conduction was considered in the present finite element simulation. A finite element formulation based on SIMPLE type algorithm was adopted for the solution of the incompressible Navier-Stokes equations. We compared the finite element solution with that of Ansys fluent 12.0, in which finite volume method was employed for spatial discretization. It was found that the finite element method gave more accurate solution than Ansys fluent 12.0. Further, it was found that the maximum temperature inside cylinder is positioned at the rear side due to the flow separation.

  • PDF

유한요소법(有限要素法)에 의(依)한 Telescope Denture의 지대치(支臺齒) 및 지지조직(支持組織)의 역학적(力學的) 반응(反應)에 관(關)한 연구(硏究) (A STUDY ON THE MECHANICAL BEHAVIORS OF ABUTMENT TEETH AND SUPPORTING TISSUE OF THE TELESCOPE DENTURE BY THE FINITE ELEMENT METHOD)

  • 김문기;최부병
    • 대한치과보철학회지
    • /
    • 제22권1호
    • /
    • pp.109-122
    • /
    • 1984
  • The purpose of this study was to analyze the magnitude and mode of the stress distribution induced in the supporting alveolar bone and periodontal ligament and, to determine the displacement of abutment teeth and telescope denture base by applying chewing force to the telescope denture quantitatively and qualitatively. Two finite element models of telescope denture that were restored the missing mandibular second molar with two abutment teeth which were constructed. In two different models, parallel and tapering type telescope crowns were constructed. These finite element models of two cases used for these experiment were a two-dimensional mesiodistal section of the mandibular second bicuspid and first molar. Chewing force of 25Kg that was devided in the ratio of 45/155 (29%) in bicuspid and 55/155 (35.5%) in molars was applied to telescope denture and abutment teeth respectively. The displacement of the telescope denture base and abutment teeth and the stress distribution in the periodontal ligament and alveolar bone were analized to investigate the influence of chewing force acting on the telescope denture and abutment teeth. The results were as follows: 1. Abutment teeth displaced mesially and the magnitude of displacement of abutment teeth in vertical direction were more than that of horizontal direction in two cases. The displacement of abutment teeth on the telescope denture treated with tapering type telescope crown were less than that of the parallel type crown. 2. The displacement of the telescope denture base that were treated with parallel type telescope crown were less than that of treated with tapering type telescope crown. 3. The stress induced in the alveolar bone and periodontal ligament on abutment teeth that treated with parallel type telescope crown were more than that of treated with tapering type telescope crown and more stress induced in the alveolar bone than in the periodontal ligament. 4. In the telescope denture, the magnitude of displacement of abutment teeth and stress induced in the periodontal ligament and alveolar bone were within physiologic limit.

  • PDF

Behavior and resistance of truss-type shear connector for composite steel-concrete beams

  • Lima, Jerfson M.;Bezerra, Luciano M.;Bonilla, Jorge;Silva, Ramon S.Y.R.C.;Barbosa, Wallison C.S.
    • Steel and Composite Structures
    • /
    • 제36권5호
    • /
    • pp.569-586
    • /
    • 2020
  • The behavior of composite steel-concrete beams depends on the transmission of forces between two parts: the concrete slab and the steel I-beam. The shear connector is responsible for the interaction between these two parts. Recently, an alternative shear connector, called Truss Type connector, has been developed; it aligns efficient structural behavior, fast construction and implementation, and low cost when compared to conventional connectors applied in composite structures. However, there is still a lack of full understanding of the mechanical behavior of the Truss Type connector, due to its novelty. Thus, this study aims to analyze the influence of variation of geometric and physical parameters on the shear resistance of the Truss Type connector. In order to investigate those parameters, a non-linear finite element model, able to simulate push-out tests of Truss Type connectors, was specifically developed and validated with experimental results. A thorough parametric study, varying the height, the angle between rods, the diameter, and the concrete strength, was conducted to evaluate the shear resistance of the Truss Type connector. In addition, an equation to predict the resistance of the original Truss Type shear connector was proposed.

마찰열을 고려한 가스시일의 그루브 설계 (Groove Design of a Gas Seal Including Friction Heatings)

  • 김청균;조승현;고영배;차백순
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2000년도 제31회 춘계학술대회
    • /
    • pp.201-210
    • /
    • 2000
  • The noncontacting groove end face seal is one of various approaches to sealing gases with a single seal. Gas pumped into groove maintains operating gap and lubricates between primary ring and mating ring. So it removes heat and decreases face wear. In this paper, K-type and T-type grooved seals have been analyzed numerically using the finite element method. It explains the effects of groove shapes in gas seals along rotating speeds with a temperature gradient, face distortion, stress and so on. The calculated FEM results show the operating gap and rotating speed are strongly related to the leakages of a gas seal and that T-type groove seal shows a good thermal performance compared to K-type groove seal.

  • PDF