• Title/Summary/Keyword: finite membrane length

Search Result 18, Processing Time 0.018 seconds

Minimum Weight Design of Laminated Composite Panel under Combined Loading (조합하중이 작용하는 복합적층 패널의 최소중량화설계)

  • Lee Jong-Sun
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.1
    • /
    • pp.95-101
    • /
    • 2006
  • Minimum weight design of laminated composite panel under combined loading was studied using linear and nonlinear deformation theories and by closed-form analysis and finite difference energy methods. Various buckling load factors are obatined for laminated composite panels with rectangular type longitudinal stiffeners and various longitudinal length to radius ratios, which are made from Carbon/Epoxy USNl25 prepreg and are simply-supported on four edges under combined loading, and then for them, minimum weight design analyses are carried out by the nonlinear search optimizer, ADS. This minimum weight design analyses are constructed with various process such as the simple design process, test simulation process and sensitivity analysis. Subseguently, the buckling mode shapes are obtained by buckling and minimum weight analyses.

Behavior Analysis of Laminated Composite Cylindrical Shells with Prebuckling (전좌굴을 고려한 복합적층원통셸의 거동해석)

  • 이종선
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.5
    • /
    • pp.150-156
    • /
    • 2000
  • The objective of this study is to investigate effects of prebuckling on the buckling of laminated composite cylindrical shells. Axial compression and lateral pressure are considered for laminated composite cylindrical shells with the ratios of length to radius. The shell walls are made of a laminate with several symmetric ply orientations. The study was made using finite difference energy method, utilizing the nonlinear bifurcation branch with nonlinear prebuckling displacements. The results are compared to the buckling loads determined when membrane prebuckling displacements are considered. Review the influence of nonlinear prebuckling for the buckling loads, the difference between the actual and classical buckling loads are increased as the increments with the ratios of length to radius, for which is applied the axial compression, but almost same for the lateral pressure.

  • PDF

Design and analysis of vibration micro piezoelectric energy harvesting for wireless sensor nodes (무선 센서 노드용 진동형 마이크로 압전 에너지 하베스팅 설계 및 분석)

  • Yoon, Kyu-Hyung;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.277-277
    • /
    • 2009
  • In this paper, PMPG (Piezoelectric Micro Power Generator) was investigated by ANSYS FEA (Finite Element Analysis) to decrease operating frequency and improve out power. The micro power generator was designed to convert ambient vibration energy to electrical power as a ZnO piezoelectric material. To find optimal model in low vibration ambient, the shape of power generator was changed with different membrane width, thickness, length, and proof mass size. Used the ANSYS modal analysis, bending mode and stress distribution of optimal model were analyzed. Also, the displacement with the frequency range was analyzed by harmonic analysis. From the simulation results, the resonance frequency of optimal model is about 373 Hz and confirmed the possibility of ZnO micro power generator for wireless sensor node applications.

  • PDF

Determination of Undrained Shear Strength of Clayey Soils from Self-Boring Pressuremeter Test (자가굴착식 프레셔미터 시험을 이용한 비배수 전당강도 산정)

  • 장인성;권오순;정충기;김명모
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.6
    • /
    • pp.117-125
    • /
    • 2000
  • 자가굴착식 프레셔미터 시험(Self-Boring Pressuremeter Test, SBPT)은 지반의 교란을 최소화할 수 있기 때문에 점성토의 비배수 전당강도($S_{u}$ )를 비교적 정확하게 평가할 수 있는 방법 중의 하나로 알려져 있으며, 많은 연구자들에 의하여 SBPT 결과로부터 $S_{u}$ 를 산정하는 여러 가지 방법들이 제안되었다. 본 연구에서는 국내 5개지역에서 총 33회의 SBPT를 수행한후, 기존에 제안된 여러 가지 방법들을 이용하여 $S_{u}$ 를 산정하고, 그 중 변형률 경화 거동을 보이는 지반에서의 $S_{u}$ 를 동일 현장에서 수행한 현장베인시험 결과와 비교. 분석하여 각 방법들의 적용성과 신뢰성을 분석하였다. 그리고, $S_{u}$ 산정 결과에 대한 프레셔미터 멤브레인의 유일한 길이의 영향을 수치해석으로 분석하였으며, 그 결과를 이용하여 기존의 접선영 방법(Subtangent method)을 보정하는 식을 제안하였다. 새로이 보정된 방법으로 산정한 $S_{u}$ 를 현장베인시험 결과와 비교하여 개선 효과를 확인하였다.

  • PDF

The Optimum Design of Ship Structures(1st Report) -Minimum Weight Design of Brackets- (선체구조(船體構造)의 최적설계(最適設計)(제1보)(第1報) -Bracket의 최소중량설계(最小重量設計)-)

  • Chang-Doo,Jang;Seung-Soo,Na
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.21 no.4
    • /
    • pp.29-39
    • /
    • 1984
  • In this paper, the membrane and buckling analysis of beams with various shaped brackets is performed by using the finite element method. From the viewpoint of minimum structural weight, a optimum design method to determine the optimal shapes and scantling of brackets under design load is proposed by investigating the effects of beam depth, bracket length and aspect ratio on the structural weight. Also optimal design data and charts for the brackets to support transverse girders or web frames of actual ships are provided. By the present design method, it is possible to perform optimum design of brackets used in actual ships, which could result in considerable reduction of structural weight or cost, increase of dead weight and service speed of ships.

  • PDF

Design and analysis of ZnO piezoelectric micro power generators with low frequency (저주파수용 ZnO 압전 마이크로 전원의 설계와 분석)

  • Chung, Gwiy-Sang;Yoon, Kyu-Hyung
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.372-376
    • /
    • 2009
  • This paper describes the characteristics of piezoelectric micro power generators by the ANSYS FEA(finite element analysis). The micro power generator was designed to convert ambient vibration energy to electrical power as a ZnO piezoelectric material. To find optimal model in low vibration ambient, the shape of power generator was changed with different membrane width, thickness, length, and proof mass size. Using the ANSYS modal analysis, bending mode and stress distribution of optimal model were analyzed. Moreover, the displacement with the frequency range was analyzed by harmonic analysis. From the simulation results, the resonance frequency of optimal model is about 373 Hz and investigate the possibility of ZnO micro power generator for ambient vibration applications.

Design of electromagnetic type transducer to drive round window with high efficiency (고효율 전자기형 정원창 구동 트랜스듀서의 설계)

  • Lee, Jang-Woo;Kim, Dong-Wook;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.449-455
    • /
    • 2010
  • Implantable middle ear hearing devices(IMEHDs) have being actively studied to overcome the problems of conventional hearing aids. Vibration transducer, an output devices of IMEHDs, is attached on the ossicular chain and transmits mechanical vibration to cochlea. This approach allows us to hear more clear sound because mechanical vibration is effective to transfer high frequency acoustics, but occurs some problems such as fatigue accumulation to ossicular chian and reduction of vibration displacement caused by mass loading effect. Recently, many studies for the round window stimulation are announced, because it does not cause such problems. It have been studied by older transducers designed for attaching on ossicular chain. In this paper, we proposed a new electromagnetic transducer which consists of two magnets, three coils and a vibration membrane. The magnet assembly, magnet coupled in opposite direction, were placed in the center of three coils, and the optimum length of each coil generating maximum vibrational force was calculated by finite element analysis(FEA). The transducer was implemented as the calculated length of each coil, and measured vibration displacement. From the results, it is verified the vibration displacement can be improved by optimizing the length of coils.

Application of numerical models to evaluate wind uplift ratings of roofs: Part II

  • Baskaran, A.;Molleti, S.
    • Wind and Structures
    • /
    • v.8 no.3
    • /
    • pp.213-233
    • /
    • 2005
  • Wind uplift rating of roofing systems is based on standardized test methods. Roof specimens are placed in an apparatus with a specified table size (length and width) then subjected to the required wind load cycle. Currently, there is no consensus on the table size to be used by these testing protocols in spite of the fact that the table size plays a significant role in wind uplift performance. Part I of this paper presented a study with the objective to investigate the impact of table size on the performance of roofing systems. To achieve this purpose, extensive numerical experiments using the finite element method have been conducted and benchmarked with results obtained from the experimental work. The present contribution is a continuation of the previous research and can be divided into two parts: (1) Undertake additional numerical simulations for wider membranes that were not addressed in the previous works. Due to the advancement in membrane technology, wider membranes are now available in the market and are used in commercial roofing practice as it reduces installation cost and (2) Formulate a logical step to combine and generalize over 400 numerical tests and experiments on various roofing configurations and develop correction factors such that it can be of practical use to determine the wind uplift resistance of roofs.