• Title/Summary/Keyword: finite element model (FEM)

Search Result 1,338, Processing Time 0.037 seconds

Evaluation of Interlayer Shear Properties and Bonding Strengths of a Stress-Absorbing Membrane Interlayer and Development of a Predictive Model for Fracture Energy (덧씌우기 응력흡수층에 대한 전단, 부착강도 평가 및 파괴에너지 예측모델 개발)

  • Kim, Dowan;Mun, Sungho;Kwon, Ohsun;Moon, Kihoon
    • International Journal of Highway Engineering
    • /
    • v.20 no.1
    • /
    • pp.87-95
    • /
    • 2018
  • PURPOSES : A geo-grid pavement, e.g., a stress-absorbing membrane interlayer (SAMI), can be applied to an asphalt-overlay method on the existing surface-pavement layer for pavement maintenance related to reflection cracking. Reflection cracking can occur when a crack in the existing surface layer influences the overlay pavement. It can reduce the pavement life cycle and adversely affect traffic safety. Moreover, a failed overlay can reduce the economic value. In this regard, the objective of this study is to evaluate the bonding properties between the rigid pavement and a SAMI by using the direct shear test and the pull-off test. The predicted fractural energy functions with the shear stress were determined from a numerical analysis of the moving average method and the polynomial regression method. METHODS : In this research, the shear and pull-off tests were performed to evaluate the properties of mixtures constructed using no interlayer, a tack-coat, and SAMI with fabric and without fabric. The lower mixture parts (describing the existing pavement) were mixed using the 25-40-8 joint cement-concrete standard. The overlay layer was constructed especially using polymer-modified stone mastic asphalt (SMA) pavement. It was composed of an SMA aggregate gradation and applied as the modified agent. The sixth polynomial regression equation and the general moving average method were utilized to estimate the interlayer shear strength. These numerical analysis methods were also used to determine the predictive models for estimating the fracture energy. RESULTS : From the direct shear test and the pull-off test results, the mixture bonded using the tack-coat (applied as the interlayer between the overlay layer and the jointed cement concrete) had the strongest shear resistance and bonding strength. In contrast, the SAMI pavement without fiber has a strong need for fractural energy at failure. CONCLUSIONS : The effects of site-reflection cracking can be determined using the same tests on cored specimens. Further, an empirical-mechanical finite-element method (FEM) must be done to understand the appropriate SAMI application. In this regard, the FEM application analy pavement-design analysis using thesis and bonding property tests using cored specimens from public roads will be conducted in further research.

Analytical Study on Structural Behavior of Surface Damaged Concrete Member by Calcium Leaching Degradation (칼슘 용출 열화에 의해 표면이 손상된 콘크리트 부재의 구조적 거동에 관한 해석적 연구)

  • Choi, Yoon-Suk;Jang, Yong-Hwan;Choi, So-Yeong;Kim, Il-Sun;Yang, Eun-Ik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.22-32
    • /
    • 2014
  • Durability is one of the most important and attractive subjects in concrete research field because not only durability of concrete is reduced by various degradation factors but also its reduction adversely influences the structural performance and service life of concrete structure. For this reason, a considerable amount of papers associated with concrete durability have been published and those researches were mainly focused on the changes of intrinsic properties of concrete due to chemicophysical degradations. However, the relationship between durability of concrete and structural behavior of concrete member has not been well established yet. In this study, calcium leaching degradation, a cause of concrete strength reduction, was dealt with. The experiments of compressive and flexural behavior of degraded concrete member were performed to evaluate the characteristics of structural behavior according to degradation level. Finally, the results from the experiments were compared with those obtained from nonlinear FEM analysis. The results from this study clearly showed that leaching degradation leads to decrease in compressive strength and compressive behavior evolves from brittle to ductile failure pattern during the degradation process. Load capacity and flexible rigidity of the degraded RC member decreased when the degradation level increased, in compressive zone. Additionally, it was found that the values from nonlinear FEM analysis, CDP model in ABAQUS, coincided well with the experimental results.

Effects of the Remanent Magnetization on Detecting Signals in Magnetic Flux Leakage System (자기누설탐상시스템에서 배관의 잔류자화가 결함신호에 미치는 영향)

  • Seo, Kang;Jeong, Hyun-Won;Park, Gwan-Soo;Rho, Yong-Woo;Yoo, Hui-Ryong;Cho, Sung-Ho;Kim, Dong-Kyu
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.6
    • /
    • pp.325-331
    • /
    • 2005
  • The magnetic Hut leakage (MFL) type nondestructive testing (NDT) method is widely used to detect corrosion and defects, mechanical deformation of the underground gas pipelines. The object pipeline is magnetically saturated by the magnetic system with permanent magnet and yokes. Because of the strong magnetic field enough to saturate the pipe, there could be distortion of the sensing signals because of the magnetization of the pipeline itself, To detect the defects precisely, the sensing signals are need to be compensated to eliminate the distortions coming from the media hysteresis. In this paper, the magnetizations of the pipeline in MFL type NDT are analyzed by Preisach model and 3D FEM. The distortions of the sensing signals are analyzed.

An Improved Bond Slip Model of CFT Columns for Nonlinear Finite Element Analysis (CFT 기둥의 비선형 유한요소해석을 위한 개선된 강관-콘크리트 간 부착 모델 개발)

  • Kwon, Yangsu;Kwak, Hyo-Gyoung;Hwang, Ju-Young;Kim, Jin-Kook;Kim, Jong-Min
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.2
    • /
    • pp.213-220
    • /
    • 2015
  • CFT column has a lot of structural advantages due to the composite behavior between in-filled concrete and steel tube. This paper deals with the development of an effective numerical model which can consider the bond-slip behavior between both components of concrete matrix and steel tube without taking double nodes. Since the applied axial load to in-filled concrete matrix is delivered to steel tube by the confinement effect and the friction, the governing equation related to the slip behavior can be constructed on the basis of the force equilibrium and the compatability conditions. In advance, the force and displacement relations between adjacent two nodes make it possible to express the slip behavior with the concrete nodes only. This model results in significant savings in the numerical modeling of CFT columns to take into account the effect of bond-slip. Finally, correlation studies between numerical results and experimental data are conducted to verifying the efficiency of the introduced numerical model.

STSAT-3 Main Payload, MIRIS Flight Model Developments

  • Han, Won-Yong;Lee, Dae-Hee;Park, Young-Sik;Jeong, Woong-Seob;Ree, Chang-Hee;Moon, Bong-Kon;Park, Sung-Joon;Cha, Sang-Mok;Nam, Uk-Won;Park, Jang-Hyun;Lee, Duk-Hang;Ka, Nung-Hyun;Seon, Kwang-Il;Yang, Sun-Choel;Park, Jong-Oh;Rhee, Seung-Wu;Lee, Hyung-Mok;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.40.1-40.1
    • /
    • 2010
  • The Main payload of the STSAT-3 (Korea Science & Technology Satellite-3), MIRIS (Multipurpose Infra-Red Imaging System) has been developed for last 3 years by KASI, and its Flight Model (FM) is now being developed as the final stage. All optical lenses and the opto-mechanical components of the FM have been completely fabricated with slight modifications that have been made to some components based on the Engineering Qualification Model (EQM) performances. The components of the telescope have been assembled and the test results show its optical performances are acceptable for required specifications in visual wavelength (@633 nm) at room temperature. The ensuing focal plane integration and focus test will be made soon using the vacuum chamber. The MIRIS mechanical structure of the EQM has been modified to develop FM according to the performance and environment test results. The filter-wheel module in the cryostat was newly designed with Finite Element Analysis (FEM) in order to compensate for the vibration stress in the launching conditions. Surface finishing of all components were also modified to implement the thermal model for the passive cooling technique. The FM electronics design has been completed for final fabrication process. Some minor modifications of the electronics boards were made based on EQM test performances. The ground calibration tests of MIRIS FM will be made with the science grade Teledyne PICNIC IR-array.

  • PDF

Nonlinear Lateral Behavior and Cross-Sectional Stress Distribution of Concrete Rocking Columns (콘크리트 회전형 기둥의 비선형 횡방향 거동 및 단면응력 분포 분석)

  • Roh, Hwa-Sung;Hwang, Woong-Ik;Lee, Hu-Seok;Lee, Jong-Seh
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.285-292
    • /
    • 2012
  • Fixed connection is generally used for beam and column connections of concrete structures, but significant damages at the connection due to severe earthquakes have been reported. In order to reduce damages of the connection and improve seismic performance of the connection, several innovative connections have been suggested. One newly proposed connection type allows a rotation of the connection for applications in rotating or rocking beams, columns, and shear walls. Such structural elements would provide a nonlinear lateral force-displacement response since their contact depth developed during rotation is gradually reduced and the stress across the sections of the elements is non-linearly distributed around a contact area, which is called an elastic hinge region in the present study. The purpose of the present study is to define the elastic hinge region or length for the rocking columns, through investigating the cross-sectional stress distribution during their lateral behavior. Performing a finite element analysis (FEA), several parameters are considered including axial load levels (5% and 10% of nominal strength), different boundary conditions (confined-ends and cantilever types), and slenderness ratios (length/depth = 5, 7, 10). The FEA results showed that the elastic hinge length does not directly depend on the parameters considered, but it is governed by a contact depth only. The elastic hinge length started to develop after an opening state and increased non-linearly until a rocking point(pre-rocking). However, the length did not increase any more after the rocking point (post-rocking) and remained as a constant value. Half space model predicting the elastic hinge length is adapted and the results are compared with the numerical results.

Development of a Closed Roof Model for Liquid Manure Storage Tanks to Prevent Corrosion and Atmospheric Diffusion of Oder Gases (부식과 악취가스 대기확산 방지를 위한 액비저장조 밀폐형 지붕모델 개발)

  • Yun, N.K.;Lee, S.H.;Kim, K.W.;Yum, S.H.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.1
    • /
    • pp.61-68
    • /
    • 2008
  • The roof structural model of liquid manure storage tank was designed to improve a structural safety and an ability of resistance to corrosion by the bad environmental condition with high humidity and high gas concentration. Due to corrosion of a general steel, the 5 years used materials were reduced to one-third of a new material in the result of a bending strength test. Some structural materials were tested to evaluate a strength and an anti-corrosion, and stainless steel pipe (STS439), steel angle with zinc hot dipping, rectangular steel pipe covered with FRP (Fiberglass Reinforced Plastics) resin were selected finally. A stainless steel is more expansive about $3{\sim}5$ times than general structural steel. But its durability under heavy corrosive environment is expected twice as long as general steel. The roof models were designed as closed cone type for each of the three structural materials. In the result of a FEM (Finite Element Method) structural analysis for the developed models, the safe snow depth was higher 2.3 times than a general roof structure, when elements of equal section modulus were used.

  • PDF

Stress distributions at the Periodontal ligament and displacements of the maxillary first molar under various molar angulation and rotation . Three dimensional finite element study (구치의 경사도와 회전정도가 발치공간 폐쇄시 치근막의 응력분포와 치아의 초기이동에 미치는 영향에 대한 3차원 유한요소법적 연구)

  • Kwon, Dae-Woo;Son, Woo-Sung;Yang, Hoon-Chul
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.417-428
    • /
    • 2004
  • The purpose of this study was to evaluate the stress distributions at the periodontal ligament (PDL) and displacements of the maxillary first molar when mesially directed force was applied under various molar angulations and rotations. A three dimensional finite element model of the maxiilary first molar and its periodontal ligament was made Upright position, mesially angulated position by $20^{\circ}$ and distally angulated position of the same degree were simulated to investigate the effect of molar angulation. An anteriorly directed force of 200g countertipping moment of 1,800gm-mm (9:1 moment/force ratio) and counterrotation moment of 1,000gm-mm (5:1 moment/force ratio) were applied in each situation. To evaluate the effect of molar rotation on the stress distribution, mesial-in rotation by $20^{\circ}$ and the same amount of distal-in rotation were simulated. The same force and moments were applied in each situation. The results were as follows: In all situations, there was no significant difference in mesially directed tooth displacement Also, any differences in stress distributions could not be found, in other words. there were no different mesial movements. Stress distributions and tooth displacement of the $20^{\circ}$ mesially angulated situation were very similar with those of the $20^{\circ}$ distal-in rotated situation. The same phenomenon was obserned between the $20^{\circ}$ distally angulated situation and $20^{\circ}$ mesial-in rotated situation. When the tooth was mesially angulated, or distal-in rotated, mesially directed force made the tooth rotate in the coronal plane. with its roots moving buccally, and its crown moving lingually. When the tooth was distally angulated, or mesial-in rotated, mesially directed force made the tooth rotate in the coronal plane, with its roots moving lingually and its crown moving buccally. When force is applied to au angulated or rotated molar, the orthodontist should understand that additional torque control is needed to prevent unwanted tooth rotation in the coronal plane.

Development of the model and the hybrid algorithm toy analyzing the dynamic heat conduction in the CPES system (CPFS 내에서 일어나는 동적 열전도 현상을 해석하기 위한 수식 및 혼합알고리즘 개발)

  • Yun Jongpil;Kwon Seong-Pil;Yoon En Sup
    • 한국가스학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.120-125
    • /
    • 2003
  • 본 연구는 원자력 발전소에 있는 방화벽의 케이블 관통부위에 설치된 CPFS(Cable Penetration Fire Stop)시스템 안에서 일어나는 동적열전달 현상을 3 차원으로 나타낼 수 있는 시험시뮬레이터에 사용될 수학적 모델과 수치계산 알고리즘의 개발에 관한 것이다. CPFS 내에서 일어나는 열전도 현상을 나타내는 지배방정식은 주어진 조건들 하에서 포물선형 편미분방정식(Parabolic PDE)으로 나타난다. 문제를 단순화하기 위해 열의 흐름을 두 성분으로 나누었다 즉, 케이블과 평행한 선을 따라서 일어나는 열전도와 벽면과 평행한 평면 위에서 일어나는 열전도로 나누었다. 먼저 선을 따라 일어나는 동적 열전도 현상을 나타내는 PDE를 연속과완화(SOR: Successive Over-Relaxation)를 적용하여 유한한 불연속점들에 대한 연립 상미분방정식(ODE)으로 전환했고, 그 연립방정식은 ODE Solver 를 이용하여 풀 수 있었다. 둘째로, 각 불연속 점에 위치한 평면 위에서 일어나는 열전도를 계산하기 위해서, 유한요소의 합을 근사식으로 이용하여 PDE를 ODE로 전환해서 계산하는 유한요소법(Finite Element Method)이 이용된다. 여기서 시간과 공간의 함수 T(x, y, z, t)인 온도는 각 선의 점들과 각 평면의 요소들에 대해서 일정한 시간간격으로 초기온도와 경계온도를 업데이트하여 계산을 반복한다. 이러한 일련의 계산결과를 바탕으로 CPFS 시스템 내에서의 온도분포의 동적인 변화를 해석한다. 결론적으로 관통하는 케이블이 CPFS 시스템의 온도분포에 매우 중요한 역할을 한다는 것을 알 수 있다. 시뮬레이션 결과는 CPFS 내의 온도분포를 쉽게 이해할 수 있도록 3 차원 그래픽으로 나타냈으며, 상용소프트웨어 FEMLAB 으로 계산한 결과와 비교해서 개발된 모델과 계산 알고리즘의 정당성을 보였다. 맞이하고 있음을 볼 수 있다. 국내광업이 21C 급변하는 산업환경에 적응하여 생존하기 위해서는 각종 첨단산업에서 요구하는 소량 다품종의 원료광물을 적기에 공급 할 수 있는 전문화된 기술력을 하루속히 확보해야 하며, 이를 위해 고품위의 원료광물 확보를 위한 탐사 및 개발을 적극 추진하고 가공기술의 선진화를 위해 선진국과의 기술제휴 등 자원산업 글로벌화 정책이 절실히 요구되고 있음을 알 수 있다. 또한 삶의 질을 향상시키려는 현대인의 가치관에 부합하기 위해서는 각종 소비제품의 원료를 제공하는 광업의 본래 목적 이외에도 자연환경 훼손을 최소화하며 개발 할 수밖에 없는 구조적인 어려움에 직면할 수밖에 없다. 이처럼 국내광업이 안고 있는 여러 가지 난제들을 극복하기 위해서는 업계와 정부가 합심하여 국내광업 육성의 중요성을 재인식하고 새로운 마음가짐으로 관련 정책을 수립 일관성 있게 추진해 나가야 할 것으로 보인다.의 연구 결과를 요약하면 다음과 같다. 첫째, 브랜드 이미지와 서비스 품질과의 관계에서 브랜드이미지는 서비스 품질의 선행변수가 될 수 있음을 증명하였으며 4개 요인의 이미지 중 사풍이미지를 제외한 영업 이미지, 제품 이미지, 마케팅 이미지가 서비스 품질에 영향을 미치고 있음을 알 수 있다. 둘째, 지각된 서비스 품질과 가격 수용성과의 관계에서, 서비스 품질은 최소 가격에 신뢰서비스 요인에서 정의 영향을 미치고 있으나 부가서비스, 환경서비스에서는 역의 영향을 미침을 알수 있고, 최대 가격에 있어서는 욕구서비스 요인은 정의 영향을 미치지만 부가서비스의 경우에는 역의 영향을 미치고 있음을 알 수 있다. 셋째, 서비스품질과 재 방문 의도와의 관계에 있어서 서비스품질은 재 방문 의도에 영향을 미침을 알 수 있다. 따라서 브랜드 이미지는 서비스품질의 선행변수가 될 수 있으며, 서비스품질은 가격 수용성과 재방문 의도에 영향을 미치고 있음을 알 수

  • PDF

Effects of Screw Configuration on Biomechanical Stability during Extra-articular Complex Fracture Fixation of the Distal Femur Treated with Locking Compression Plate (잠김 금속판(LCP-DF)을 이용한 대퇴골 원위부의 관절외 복합골절 치료시 나사못 배열에 따른 생체역학적 안정성 분석)

  • Kwon, Gyeong-Je;Jo, Myoung-Lae;Oh, Jong-Keon;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.199-209
    • /
    • 2010
  • The locking compression plates-distal femur(LCP-DF) are being widely used for surgical management of the extra-articular complex fractures of the distal femur. They feature locking mechanism between the screws and the screw holes of the plate to provide stronger fixation force with less number of screws than conventional compression bone plate. However, their biomechanical efficacies are not fully understood, especially regarding the number of the screws inserted and their optimal configurations. In this study, we investigated effects of various screw configurations in the shaft and the condylar regions of the femur in relation to structural stability of LCP-DF system. For this purpose, a baseline 3-D finite element (FE) model of the femur was constructed from CT-scan images of a normal healthy male and was validated. The extra-articular complex fracture of the distal femur was made with a 4-cm defect. Surgical reduction with LCP-DF and bone screws were added laterally. To simulate various cases of post-op screw configurations, screws were inserted in the shaft (3~5 screws) and the condylar (4~6 screws) regions. Particular attention was paid at the shaft region where screws were inserted either in clustered or evenly-spaced fashion. Tied-contact conditions were assigned at the bone screws-plate whereas general contact condition was assumed at the interfaces between LCP-DF and bone screws. Axial compressive load of 1,610N(2.3 BW) was applied on the femoral head to reflect joint reaction force. An average of 5% increase in stiffness was found with increase in screw numbers (from 4 to 6) in the condylar region, as compared to negligible increase (less than 1%) at the shaft regardless of the number of screws inserted or its distribution, whether clustered or evenly-spaced. At the condylar region, screw insertion at the holes near the fracture interface and posterior locations contributed greater increase in stiffness (9~13%) than any other locations. Our results suggested that the screw insertion at the condylar region can be more effective than at the shaft during surgical treatment of fracture of the distal femur with LCP-DF. In addition, screw insertion at the holes close to the fracture interface should be accompanied to ensure better fracture healing.