• 제목/요약/키워드: finite connection-length

검색결과 55건 처리시간 0.023초

지대주 연결 형태와 골질에 따른 저작압이 임프란트 주위골내 응력분포에 미치는 영향 (Study on the stress distribution depending on the bone type and implant abutment connection by finite element analysis)

  • 박현수;임성빈;정진형;홍기석
    • Journal of Periodontal and Implant Science
    • /
    • 제36권2호
    • /
    • pp.531-554
    • /
    • 2006
  • Oral implants must fulfill certain criteria arising from special demands of function, which include biocompatibility, adequate mechanical strength, optimum soft and hard tissue integration, and transmission of functional forces to bone within physiological limits. And one of the critical elements influencing the long-term uncompromise functioning of oral implants is load distribution at the implant- bone interface, Factors that affect the load transfer at the bone-implant interface include the type of loading, material properties of the implant and prosthesis, implant geometry, surface structure, quality and quantity of the surrounding bone, and nature of the bone-implant interface. To understand the biomechanical behavior of dental implants, validation of stress and strain measurements is required. The finite element analysis (FEA) has been applied to the dental implant field to predict stress distribution patterns in the implant-bone interface by comparison of various implant designs. This method offers the advantage of solving complex structural problems by dividing them into smaller and simpler interrelated sections by using mathematical techniques. The purpose of this study was to evaluate the stresses induced around the implants in bone using FEA, A 3D FEA computer software (SOLIDWORKS 2004, DASSO SYSTEM, France) was used for the analysis of clinical simulations. Two types (external and internal) of implants of 4.1 mm diameter, 12.0 mm length were buried in 4 types of bone modeled. Vertical and oblique forces of lOON were applied on the center of the abutment, and the values of von Mises equivalent stress at the implant-bone interface were computed. The results showed that von Mises stresses at the marginal. bone were higher under oblique load than under vertical load, and the stresses were higher at the lingual marginal bone than at the buccal marginal bone under oblique load. Under vertical and oblique load, the stress in type I, II, III bone was found to be the highest at the marginal bone and the lowest at the bone around apical portions of implant. Higher stresses occurred at the top of the crestal region and lower stresses occurred near the tip of the implant with greater thickness of the cortical shell while high stresses surrounded the fixture apex for type N. The stresses in the crestal region were higher in Model 2 than in Model 1, the stresses near the tip of the implant were higher in Model 1 than Model 2, and Model 2 showed more effective stress distribution than Model.

A parametric study on fatigue of a top-tensioned riser subjected to vortex-induced vibrations

  • Kim, Do Kyun;Wong, Eileen Wee Chin;Lekkala, Mala Konda Reddy
    • Structural Monitoring and Maintenance
    • /
    • 제6권4호
    • /
    • pp.365-387
    • /
    • 2019
  • This study aims to provide useful information on the fatigue assessment of a top-tensioned riser (TTR) subjected to vortex-induced vibration (VIV) by performing parametric study. The effects of principal design parameters, i.e., riser diameter, wall thickness, water depth (related to riser length), top tension, current velocity, and shear rate (or shear profile of current) are investigated. To prepare the base model of TTR for parametric studies, three (3) riser modelling techniques in the OrcaFlex were investigated and validated against a reference model by Knardahl (2012). The selected riser model was used to perform parametric studies to investigate the effects of design parameters on the VIV fatigue damage of TTR. From the obtained comparison results of VIV analysis, it was demonstrated that a model with a single line model ending at the lower flex joint (LFJ) and pinned connection with finite rotation stiffness to simulate the LFJ properties at the bottom end of the line model produced acceptable prediction. Moreover, it was suitable for VIV analysis purposes. Findings from parametric studies showed that VIV fatigue damage increased with increasing current velocity, riser outer diameter and water depth, and decreased with increasing shear rate and top tension of riser. With regard to the effects of wall thickness, it was not significant to VIV fatigue damage of TTR. The detailed outcomes were documented with parametric study results.

다이아그리드 구조시스템의 접합부개발과 성능평가 (An Structural Design for Cyclone Tower's Connections Using Diagrid System)

  • 이세정;이성희;김진호;최성모
    • 한국공간구조학회논문집
    • /
    • 제10권2호
    • /
    • pp.105-115
    • /
    • 2010
  • 최근 초고층 건축물은 비정형적 외관을 갖는 랜드 마크적인 역할과 택지의 효율적인 사용을 위한 수직 도시 기능을 수행한다. 건축물의 외관은 비정형적인 요소로서 3T형태(Twisted, Tilted, Tapered)의 설계안들이 대부분 제안되고 있으며, 세장한 형태의 형상비를 만족하기 위한 새로운 구조시스템의 연구 개발이 활발히 진행 중이다. 다이아그리드 시스템의 하중 전달 메커니즘은 대각 가새(Diagrid)의 삼각형 형상에 기인하여 중력하중 뿐만 아니라 횡하중을 전달하기 때문에 대부분의 기둥이 제거되게 된다. 또한 대각 가새의 축방향 거동(인장/압축)에 의해 전단력을 전달하여 전단 변형이 최소화되기 때문에 기둥이 전단력을 전달하던 기존 방식에 비해 비정형적인 외관에 쉽게 대응할 수 있는 구조시스템이다. 본 연구에서는 싸이클론 타워의 건축 계획안을 바탕으로 접합부 디테일 선정 과정과 접합부의 구조안전성을 유한요소해석을 통해 검증하였다. 이를 통해 응력집중 완화 방안을 제시하여 적절한 캡 플레이트 두께와 캡플레이트 확장 길이를 제시하여 응력집중 현상을 완화하였다.

  • PDF

경사형 내부연결 임플란트 시스템 (SS $III^{(R)}$)에서 지대주 형태에 따른 응력분포의 3차원 유한요소 분석 (A 3-dimensional finite element analysis of tapered internal connection implant system (Avana SS $III^{(R)}$) on different abutment connections)

  • 이혜승;김명래;박지만;김선종
    • 대한치과보철학회지
    • /
    • 제48권3호
    • /
    • pp.181-188
    • /
    • 2010
  • 연구 목적: 내부연결형 임플란트 고정체에 연결 방식이 다른 4종류의 지대주를 연결하여 교합력을 가하였을 때 각 구조에 발생하는 응력의 차이를 비교하고, 이들 연결방식이 임플란트 주위조직의 응력분포에 미치는 영향을 3차원 유한요소법을 통하여 알아보고, 지대주의 선택 기준을 마련하고자 하였다. 연구 재료 및 방법: 고정체로는 직경 4 mm, 길이 11.5 mm의 SS-$III^{(R)}$ (Osstem, Korea)를 사용하였으며, 사용된 지대주는 각각, 모델 1에서 Solid abutment, 모델 2에서 Com-Octa abutment, 모델 3에서 ComOcta Gold abutment, 모델 4에서 Octa abutment를 사용하였고, 네 가지 하중조건으로 치관중심와 (central fossa)에 fixture 장축에 평행하게 점하중으로100N의 수직하중, 협측교두에 대하여 fixture 장축에 평행하게 점하중으로 100N 수직하중, 치관중심와에서 설측으로 100N의 $30^{\circ}$ 경사하중, 협측교두 (buccal cusp)에 치아의 바깥쪽에서 내측으로 100N의 $30^{\circ}$ 경사하중을 주었고 3G.Author (Plasso Tech, USA)를 이용하여 분석하였다. 결과: 1. 골조직에서는 모든 모델에서 하중조건에 관계없이 가장 큰 응력이 고정체 상부에 집중되었고, 고정체 하부에서는 근단 부위에서 응력 집중을 보였으며, 그 외의 부위에서는 큰 응력 집중은 보이지 않았다. 2. 고정체에서의 응력은 모든 모델에서 하중조건에 관계없이 neck 부위에서 최대의 양상을 보였다. 3. 응력은 골에서보다 임플란트 내부에서 훨씬 높았다. 4. 중심와에 수직하중인 하중조건 1에서 가장 낮은 응력이 관찰되었으며, 이 때의 응력집중 현상도 가장 적게 나타났다. 서로 다른 지대주에서 응력분포 양상을 살펴본 결과, 같은 고정체를 사용한 경우에 지대주의 연결 형태에 따른 골조직에서의 응력 분포의 차이는 없었다.

2단 적응 등화기의 직렬 연결에 의한 MMA 알고리즘의 수렴 속도 개선 (Convergence Speed Improvement in MMA Algorithm by Serial Connection of Two Stage Adaptive Equalizer)

  • 임승각
    • 한국인터넷방송통신학회논문지
    • /
    • 제15권3호
    • /
    • pp.99-105
    • /
    • 2015
  • 본 논문에서는 nonconstant modulus 신호를 대상으로 채널의 찌그러짐에 의한 부호간 간섭을 보상하기 위한 MMA (Multiple Modulus Algorithm) 적응 등화기를 가변 적응 스텝 크기를 적용하지 않고 2단의 직렬 연결 형태로 구현하여 수렴 속도를 개선할 수 있는 mMMA (modified MMA)에 대하여 다룬다. 적응 등화기는 유한 차수의 탭 지연선에 의한 단일 디지털 필터로 구현되므로, 논문에서는 이를 2단의 직렬 연결 필터로 구현한 후 각 단에서는 MMA와 동일한 알고리즘으로 오차 신호를 얻은 후 필터 계수를 갱신하게 된다. 따라서 첫단에는 빠른 수렴 속도를 결정하며, 두 번째단에서는 첫단의 출력에 포함되어 있는 잔류 isi양을 최소화시키도록 탭 계수를 갱신한다. 이때 1단 시스템과 2단 시스템은 동일한 차수의 필터가 되도록 조정하면서 적응 등화 성능을 비교하였으며, 성능 비교를 위한 지수로는 등화기 출력 신호 성상도, 수렴 특성을 나타내는 잔류 isi, 최대 찌그러짐과 MSE, 채널의 신호대 잡음비에 따른 SER을 사용하였다. 시뮬레이션 결과 2단의 FIR 구조를 갖는 mMMA가 1단의 기존 MMA보다 등화 잡음에 의한 성상도를 제외한 모든 성능 지수에서 우월하며, 수렴 속도는 1.5~1.8배 정도 개선됨을 확인하였다.