• Title/Summary/Keyword: finger

Search Result 2,173, Processing Time 0.029 seconds

The Estimation of Hand Pose Based on Mean-Shift Tracking Using the Fusion of Color and Depth Information for Marker-less Augmented Reality (비마커 증강현실을 위한 색상 및 깊이 정보를 융합한 Mean-Shift 추적 기반 손 자세의 추정)

  • Lee, Sun-Hyoung;Hahn, Hern-Soo;Han, Young-Joon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.7
    • /
    • pp.155-166
    • /
    • 2012
  • This paper proposes a new method of estimating the hand pose through the Mean-Shift tracking algorithm using the fusion of color and depth information for marker-less augmented reality. On marker-less augmented reality, the most of previous studies detect the hand region using the skin color from simple experimental background. Because finger features should be detected on the hand, the hand pose that can be measured from cameras is restricted considerably. However, the proposed method can easily detect the hand pose from complex background through the new Mean-Shift tracking method using the fusion of the color and depth information from 3D sensor. The proposed method of estimating the hand pose uses the gravity point and two random points on the hand without largely constraints. The proposed Mean-Shift tracking method has about 50 pixels error less than general tracking method just using color value. The augmented reality experiment of the proposed method shows results of its performance being as good as marker based one on the complex background.

Functional MR Imaging of Cerebral Motor Cortex on 3 Tesla MR Imaging : Comparison between Gradient and Spin-Echo EPI Techniques (3T에서 뇌 운동피질의 기능적 자기공명영상 연구 : Gradient-Echo와 Spin-Echo EPI의 비교)

  • Goo, Eeu-Hoe;Chang, Hye-Won;Chung, Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.31-38
    • /
    • 2007
  • To evaluate the accuracy and extent in the localization of cerebral motor coutex activation using a gradient- echo echo planar imaging(GE-EPI) compared to spin-echo echo planar iimaging(SE-EPI) on 3T MR imaging. Functional MR imaging of cerebral motor cortex activation was examined in GE-EPI and SE-EPI in five healthy male volunteers. A right finger movement was accomplished with a paradigm of 6 task and rest, periods and the cross-correlation was used for a statistical mapping algorithm. We evaluated any sorts of differenced of the time seried and the signal intensity changes between the rest and task periods obtained with two technoques. The qualitative analysis was distributed with activation sites of large veins and small veins by using two techniques and was found that both the techniques were clinically uesful for delineating large veins and small veins in fMRL Signal intensity charge of the rest and activation periods provided simmilar activations in both methods(GE-EPI : 0.93$\pm$0.11, SE-EPI : 0.80$\pm$.015) but the signal intensity in GE-EPI(133.95$\pm$15.76) was larger than in SE-EPI(74.5$\pm$18.90). The average SNRs of EPI raw data were higher at SMA in SE-EPI(48.54$\pm$12.37) than GE-EPI(41.4$\pm$12.54) and at M1 in SE-EPI(43.24$\pm$11.77) than GE-EPI(38.27$\pm$6.53). The localization of activation voxels of the GE-EPI showed a larger vein but the SE-EPI generally showed small vein. Then the analysis results of the two techniques were used for a statistacal paired student t-test. SE-EPI was found clinically useful for localizing the cerebral moter cortex cativation on 3.0T, but showed a little different activation patterns comparad to GE-EPI. In conclusion, SE-EPI may be feasible and can detect true cortical activation from capillaries and GE-EPI can obtain the large veins in the motor cortex activation on 3T MR imaging.

  • PDF

A Comparative Study of the Effect of Resisted Exercise Using Thera-bands according to Grip Type: Pain and Range of Motion of the Shoulder in a Patient with Lymphedema after Mastectomy (그립 유형에 따른 탄력밴드 저항운동 효과의 비교 연구 ; 유방절제술로 발생한 팔 림프부종 환자에 대한 통증 및 어깨관절가동범위에 대하여)

  • Jo, Yejin;Lee, Sangryul
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.1
    • /
    • pp.47-56
    • /
    • 2020
  • Purpose : The purpose of this study was to determine the effects of upper extremity volume, pain, and range of motion after participation in thera-band exercises according to the hand grip type in patients with breast cancer with upper extremity edema. We also aimed to determine the most efficient type of grip. Methods : The subjects were 10 female patients diagnosed with stage 2 breast cancer who had stage 2 lymphedema. Randomly, 5 patients each were allocated to the experimental and control groups. For six weeks, the patients in both the experimental and control groups exercised daily. In both groups, manual lymph drainage was applied for 1 hour. Afterward, patients in the experimental group placed their hands in the thera-band ring and exercised with their fingers outstretched. Patients in the control group exercised while holding the thera-band ring with a finger. Both the experimental group and the control group underwent measurements of the circumference of the upper extremity, pain, and range of motion of the shoulder joint at weeks 1, 2, 4, and 6 before and after exercise. Results : The upper arm circumference decreased by more in the experimental group in all weeks than before than that in the control group, and there was a statistically significant difference at 6 weeks. Compared with the difference between pre-exercise and 6 weeks post-exercise, the change in pain significantly decreased in the experimental group and showed a statistically significant difference. The shoulder range of motion increased in extension, external rotation, and internal rotation compared with that in the control group, and there was a statistically significant difference. Although the operating range increased in flexion and abduction, there were no statistically significant differences. Conclusion : In this study, we found that thera-band exercises with an open-hand grip are more efficient than thera-band exercises with a closed-hand grip in edema reduction, pain, and range of motion. In addition, it was found that it was more effective to continue the thera-band exercises with open-hand grip extended for at least 6 weeks rather than for a short time.

Functional Evaluation of Thumb Reconstruction according to the Level of Amputation (절단부위에 따른 수무지 재건의 기능적 평가)

  • Lee, Kwang-Suk;Park, Joung-Woong;Suh, Dong-Hun;Chung, Woong-Kyo
    • Archives of Reconstructive Microsurgery
    • /
    • v.7 no.2
    • /
    • pp.135-145
    • /
    • 1998
  • In 1980 Morrison and O'Brien reported their experiences about the reconstruction of amputated thumb using wrap-around neurovascular free flap from the great toe with a nonvascularized iliac bone graft. From then it has been considered to be a good reconstructive procedure for the amputated thumb, but it's indication has been limited distal to the metacarpophalangeal(MP) joint. We have performed 37 cases of wrap-around free flap from the great toe for the reconstruction of thumb amputated at distal or proximal to the MP joint and investigated their functional results according to the level of amputation. Level of amputation was distal to the MP joint in 25 cases and proximal to it in 12 cases. Pinching and grasping power, two point discrimination and the amount of opposition to the other fingers were compared to the uninjured hand. Pinching and grasping power were not significantly different according to the level of amputation but the amount of two point discrimination was significantly high in the cases amputated proximal to the MP joint. The opposition of reconstructed thumb to the other fingers was completely possible in all cases amputated distal to the MP joint. In 12 cases amputated proximal to the MP joint of the thumb, opposition was completely possible in 6 cases in which the iliac bone block was fixated in the position of $30^{\circ}$ flexion and $45^{\circ}$ internal rotation but in 6 cases in the fixation of $30^{\circ}$ flexion and $30^{\circ}$ internal rotation, the opposition of reconstructed thumb to the ring and little fingers were impossible in 5 cases and only to the little finger in 1 case. In this study, we concluded that even if amputation proximal to the MP joint, it is no more contraindication of the wrap-around free flap procedure for thumb reconstruction, however in these cases we recommend iliac bone block fixation in the position of $30^{\circ}$ flexion and $45^{\circ}$ infernal rotation for the better functional outcome.

  • PDF

Subhective Symptoms and Work-related Health Risk Factors in Korean Dental Laboratory Technicians (우리 나라 치과 기공사의 신체 자각 증상과 직업 관련 건강 위험 요인)

  • Kim, Woong-Chul;Lee, Se-Hoon
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.89-112
    • /
    • 2000
  • Although dental laboratory technicians are prone to be exposed to various work-related health hazardous materials such as dusts, chemicals, etc., the prevalence and nature of work-related health problems of them have not been a matter of great concern in the field of occupational health service in Korea. The purpose of the present investigation was to describe a collected profile of subjective health symptoms and their attributable factors in Korean dental laboratory technicians. A questionnaire listing five groups of health symptoms and five health symptom-related factors was mailed to randomly selected 1,900 dental laboratory technicians. Among them, 1,344 dental laboratory technicians filled out the questionnaires and returnde them. Five groups of health symptoms included musculoskeletal symptom, dermal symptoms, respiratory symptoms, eys symptoms, and ear symptoms. Five health symptom-related factors were occupational environment-related health risk factors, work history, health related habits and status, use of personal protective equipment and general characteristics. Detailed parameters of health risk factors were work posture, vibration, and chemical or physical hazards such as dust, fume, vapor, solvent, light, and noise for occupational environment-related factors; work place, area, number of employees, work hours, career, work part, and work load for work history; Broca's index, hours of sleep, eating, smoking, alcohol, exercise, health examination, and self assessed health status for health habits and status; face masks, goggles, and so on for use of personal protective equipment, and; age, sex, marital status, and education for general characteristics. Before the start of main survey, a pilot survey was carried out for validity and reliability tests of the questionnaire. All the data obtained were coded and analyzed with PC/SAS 6.12 program. The prevalence of health symptoms was the highest in musculoskelton (87.3%), and followde by eyes (78.9%), respiratory organs (64.3%), ears (57.8%), and skin (52.2%) in descending order. Statistically significant risk factors by multiple logistic regression analyses were sex, health examination, self assessed health status, and hand/finger posture in musculoskeletal symptoms; sex, self assessed health status, career, acid gas, and hand contact with resin mixture in deraml symptoms; Broka's smoking, exercise, self assessed health status, and face mask in respiratory symptoms; sex, hours of sleep, self assessed health status, work hours, work load, plaster dust, inadequate lighting, and goggle in eys symptoms, and eating, smoking, self assessed health status, and work load in ear symptoms. With the above considerations in mind, prevalence of subjective symptoms among Korean dental laboratory technicians was relatively high, and they were attributable to most of the occupational environment-related factors, work history, use of personal protective equipment, health habits and status, and general characteristics. Particularly, it is suggested that health promotion programs for promoting self- assessed health status and smoking cessation, preventive measures for protection of the female technicians’health, and reducing work load be necessary, since those factors were associated with more than one subjective symptom.

  • PDF

Microleakage and Anticariogenic Effect of S-PRG Filler-containing Pit and Fissure Sealant (S-PRG filler를 함유한 치면열구전색제의 미세누출 및 항우식효과)

  • Shin, Seungwoo;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.4
    • /
    • pp.247-252
    • /
    • 2013
  • Pit and fissure sealant prevents biofilm accumulation, plays a role in forming a barrier to acidic substance made by the bacteria. The Surface reaction-type pre-reacted glass ionomerI(S-PRG) filler was developed in 1999. S-PRG filler releases fluoride continuously and does not decompose under wet conditions. The aim of this study was to test the microleakage and anticariogenic effect to adjacent enamel of S-PRG filler-containing pit and fissure sealant. Sound premolars and molars were used in this study. A S-PRG filler-containing pit and fissure sealant, Beautisealant$^{(R)}$(Shofu, Japan) was used for this experiment, the composite resin sealant Concise$^{(R)}$(3M ESPE, USA) was used as control. For the microleakage test, all teeth surface were double coated with finger nail varnish, with the exception of a 1.0 mm window around the restoration margins. The teeth were immersed in 2% methylene blue solution for 24 hours and then rinsed in tap water. For the anticariogenic effect evaluation, all tooth were immersed in artificial carious solution for 9 days and rinsed with tap water. Each tooth was embedded in orthodontic acrylic rein and subsequently sectioned longitudinally in a bucco-lingual direction with a low-speed diamond saw. The cut sections were examined using a stereomicroscope. Differences in microleakage between the two groups were not different significantly. But the S-PRG filler-containing pit and fissure sealant showed higher anticariogenic effect than that of flowable resin sealant.

Measurements of Fast Transient Voltages due to Human Electrostatic Discharges (인체에 대전된 정전기 방전에 의해 발생한 급속과도전압의 측정)

  • 이복희;이동문;강성만;엄주홍;이태룡;이승칠
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.108-116
    • /
    • 2002
  • This paper presents the measurements and evaluation of voltage waveforms due to human electrostatic discharge(ESD). The principle of operation and design rule of a new device for measuring the ESD fast transient voltages with very fast rise time were described. Peak values and rise time of ESD voltages derived from a charged human body under a variety of experimental conditions were examined. The frequency bandwidth of the proposed voltage measuring system ranges from DC to 400[㎒]. The ESD voltage waveform is nearly equal to the ESD current waveform and the peak amplitude of ESD current waveform is roughly proportional to the ESD voltage in each experimental conditions. A rapid approach results in a discharge voltage with a faster initial rise time than for a slow approach. The voltages caused by direct finger ESDs have an initial slope with a relatively long, 10∼30[ns] rise time, but the amplitude is small. On the other hand, the voltages caused by direct hand/metal ESDs have a steep initial s1ope with 1 ∼3[ns] rise time, but an initial spike is very big. As a consequence, it was found that the ESD voltage and current waveforms strongly depend on the approach speed and material of intruder. These measurement results would be useful to design the ESD protective devices.

Glutamine Deprivation Inhibits Invasion of Human Prostate Carcinoma LnCap Cells through Inactivation of Matrix Metalloproteinases and Modulation of Tight Junctions (글루타민 결핍에 따른 Tight Junction 및 MMPs 활성 조절을 통한 전립선 암세포의 침윤 억제 현상)

  • Shin, Dong Yeok;Choi, Yung Hyun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.8
    • /
    • pp.1167-1174
    • /
    • 2013
  • Cancer cells exhibit increased demand for glutamine-derived carbons to support anabolic processes. Indeed, the spectrum of glutamine-dependent tumors and the mechanisms through which glutamine supports cancer metabolism remain areas of active investigation. In the present study, we investigated the effects of glutamine deprivation on the correlation between tightening of tight junctions (TJs) and anti-invasive activity in human prostate carcinoma LnCap cells. Glutamine deprivation markedly inhibited cell motility and invasiveness in a time-dependent manner. The anti-invasive activity of glutamine deprivation was associated with an increased tightness of the TJ, which was demonstrated by an increase in transepithelial electrical resistance (TER). The activities of matrix metalloproteinase (MMP)-2 and MMP-9 were inhibited in a time-dependent fashion by glutamine deprivation, which was correlated with a decrease in expression of their mRNA and proteins and up-regulation of tissue inhibitors of metalloproteinases (TIMPs) expression. Furthermore, glutamine deprivation repressed the levels of the claudin family members, which are major components of TJs that play a key role in the control and selectivity of paracellular transport. Moreover, the levels of E-cadherin, a type I transmembrane glycoprotein, and snail, an epithelial to mesenchymal transition regulator and zinc finger transcription factor, were markedly modulated by glutamine deprivation. Taken together, these findings suggest that TJs and MMPs are critical targets of glutamine deprivation-induced anti-invasion in human prostate carcinoma LnCap cells.

The Correlation between $2^{nd}$ to $4^{th}$ Digit Length Ratio and Characteristics of Temperament and Character in University Students (제2수지-제4수지 길이 비율과 기질 및 성격 특성간의 상관관계)

  • Jeon, Sang Won;Kim, Seok Hyeon;Oh, Dong Hoon;Lee, Yu Sang;Lee, Sun Hye
    • Korean Journal of Biological Psychiatry
    • /
    • v.17 no.3
    • /
    • pp.136-144
    • /
    • 2010
  • Objectives : The $2^{nd}$ to $4^{th}$ digit length(2D : 4D) ratio reflects the amount of exposure and sensitivity to the prenatal sex hormone and it is considered to be the most convenient and useful way to understand the influence of sex hormone in the determination of human behavioral traits. This study was carried out to find the correlation between the 2D : 4D ratio and characteristics of temperament and character in Korean university students. We assumed that 2D : 4D ratio would show a strong correlation with temperament which is defined to be an inclination of an automatical emotional response to a stimulus. Methods : Participants were 104 university students who completed 2 self-report measures : Temperament and Character Inventory(TCI), Temperament Test. We examined the 2D : 4D ratio of each subject by measuring the lengths of the $2^{nd}$ and $4^{th}$ fingers using a photocopy measurement. We performed statistical analyses using correlation test and t-test to examine the relationship between 2D : 4D ratio and psychological characteristics. Results : We found out the typical sex difference in 2D : 4D ratio. Women had significantly higher 2D : 4D ratio than men. TCI-Character factor(TCI-C) didn't show any significant correlation with the 2D : 4D ratio. TCI-Tempterament factor(TCI-T) and the item of Temperament Test showed a significant correlation with the 2D : 4D ratio. In correlation analysis of the total group including all women and men, the 2D : 4D ratio showed a significant positive correlation in a subscale(shyness with stranger) of harm avoidance scales in TCI-T. In correlation analysis of women's group, the 2D : 4D ratio showed a significant positive correlation in two subscales( fear of uncertainty) and[shyness to stranger] of harm avoidance scales in TCI-T. In correlation analysis of men's group, the 2D : 4D ratio showed a significant negative correlation with a sanguine temperament item of the Temperament Test. Conclusion : The results suggest that the amount of exposure to sex hormone in the prenatal period seems to have an impact on the determination of temperament and characteristics.

Pharmacological Functional Magnetic Resonance Imaging of Cloropidol on Motor Task (운동과제에 대한 클로피도그렐의 약리적 뇌자기공명영상)

  • Chang, Yong-Min
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.136-141
    • /
    • 2012
  • Purpose : To investigate the pharmacologic modulation of motor task-dependent physiologic responses by antiplatelet agent, clopidogrel, during hand motor tasks in healthy subjects. Materials and Methods: Ten healthy, right-handed subjects underwent three functional magnetic resonance (fMRI) sessions: one before drug administration, one after high dose drug administration and one after reaching drug steady state. For the motor task fMRI, finger flexion-extension movements were performed. Blood oxygenation level dependent (BOLD) contrast was collected for each subject using a 3.0 T VHi (GE Healthcare, Milwaukee, USA) scanner. $T2^*$-weighted echo planar imaging was used for fMRI acquisition. The fMRI data processing and statistical analyses were carried out using SPM2. Results: Second-level analysis revealed significant increases in the extent of activation in the contralateral motor cortex including primary motor area (M1) after drug administration. The number of activated voxels in motor cortex was 173 without drug administration and the number increased to 1049 for high dose condition and 673 for steady-state condition respectively. However, there was no significant difference in the magnitude of BOLD signal change in terms of peak T value. Conclusion: The current results suggest that cerebral motor activity can be modulated by clopidogrel in healthy subjects and that fMRI is highly senstive to evidence such changes.