• Title/Summary/Keyword: filtration velocity

Search Result 142, Processing Time 0.023 seconds

FLUX DECLINE DURING THE ULTRA-FILTRATION OF DILUTE SI COLLOIDAL SOLUTION WITH HOLLOW FIBER MEMBRANE

  • Park, Ho-Sang;Nam, Suk-Tae;Jeon, Jae-Hong;Lee, Seok-Ki
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.07a
    • /
    • pp.95-96
    • /
    • 1999
  • The ultrafiltration behavior of dilute colloidal solution containing Si particles has been investigated. The experiments in cross flow mode have been performed at different operating condition by using the membrane with 20 kDa cut-off. The flux decline was due to the development of membrane fouling which was a dynamic process of two distinctive stages. For the high trans-membrane pressure, the pore blocking resistance was dominant at the initial period of filtraion and was followed by the cake resistance. And for the low cross flow velocity, the membrane fouling was governed by the cake filtration model at the initial stage of filtration process. Flux jump was observed temporally during the membrane filtration of mixed feed solution.

  • PDF

Influence of Filtrate Quality by Variation of Operating Filter Number Based on Inflow (유입유량과 연계한 여과지 가동지수 변동 운영이 여과수 수질에 미치는 영향)

  • Kim, Jin-Keun;Lee, Jung-Tack
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.817-824
    • /
    • 2009
  • To prevent turbidity breakthrough in a depth filter caused by hydraulic shock loads, influence of turbidity and particle number in filtrate by variation of operating filter number depending on inflow change was investigated. Inflow quantity at the S water treatment plant (WTP) was varied and ratio of maximum/minimum inflow quantity was 2.2, therefore filtration velocity was also subsequently changed. The S WTP changed operating filter number depending on inflow variation to minimize change of filtration velocity. Particle breakthrough was not severe when operation system was changed, out-of-operation and re-start of filter was repeated depending on inflow quantity. Slight particle breakthrough was noticed when re-start of filter was implemented at the filter that had a cumulative filtration run time of less than 10 h or more than 50 h. This can be attributed to the inadequate ripening and over accumulation of particles on media. Therefore, it is more efficient to choose a re-starting filter basin which has cumulative filtration run time more than 10 h or less than 50 h to reduce particle breakthrough. Filter number variation depending on inflow change was proven to be a method for improvement of unit filter run volume (UFRV).

A Study about Applicability of Treatment for Water Treatment Residual Sludge Using Crossflow Tubular Membrane System (정수장 배출수 처리를 위한 Crossflow 관형막 여과 공정의 운전 적용에 관한 연구)

  • Kim, Young Hoon;Kim, Kwan Yeop;Kim, Ji Hoon;Lee, Yong Soo;Lee, Eui Jong;Eom, Jung Yeol;Kim, Hyung Soo;Hwang, Sun Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.499-505
    • /
    • 2009
  • Many other countries have investigated the residual sludge treatment process to save the existing water resource and produce the high suspended solid concentration sludge. There are various methods for concentrating residual sludge, but the membrane system has received the most interest for its efficiency. The objective of this study was to evaluate the application of membrane filtration system for the residual sludge treatment. The experiment equipment was composed of Lab scale Crossflow tubular membrane filtration system. Generally, crossflow operation mode demands high electric cost mainly for the pump energy. So to cut off electric cost, very low Crossflow velocity was used in this experiment. Results confirmed that suspended solid concentration of residual sludge could be concentrated to 57,000mg/L in low Crossflow velocity tubular membrane system,. This concentration can be directly injected into the dehydrator. Based on the results, we know that the Crossflow tubular membrane system should be replaced conventional residual sludge treatment system.

Measurements of Dust Velocity Field around the Ceramic Candle Filter (세라믹 캔들 필터 주위의 분진 속도분포 측정)

  • Ko, Yong-Seo;Chung, Jin-Do;Kim, Seung-Tea
    • Clean Technology
    • /
    • v.5 no.1
    • /
    • pp.30-41
    • /
    • 1999
  • The experimental set-up with a 1m long ceramic candle filter of Schumacher(Germany) was built in this work. The dust velocity field around the filter was measured using PDPA. The effects of dust cake layer and dust inlet position on the dust velocity field were also analyzed. It was found that the filtration velocity decreases as the dust cake builds up on the filter. The filtration velocity largely decreases around the filters near the dust inlet since the dust cake develops fast there. The average dust velocity on the filter due to the pressure difference through the filter was measured to be 0.28m/s. More uniform dust velocity field around the filter was obtained when feeding dust in a lower position of the pressure vessel.

  • PDF

Filtration Characteristics of the Fugitive Dust Emitting from Animal Feedstuff Handling (사료 부원료 하역과정에서 발생하는 비산먼지의 여과특성)

  • Bang Jin-Chul;Han Se-Hyun;Jung Yong-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.2
    • /
    • pp.191-199
    • /
    • 2006
  • Animal feedstuff handling is one of the major fugitive dust sources in the port of Incheon. For the effective control of fugitive dusts emitting from the port of Incheon, dust control facilities with bag filter systems should be designed properly considering the characteristic of the fugitive dusts including those from animal feedstuffs. The ultimate goal of this study is thus to develop the optimum fugitive dust control system which will be applicable for the renovation of the port. As the first step to achieve this longstanding goal, filtration characteristics of soybean shell, the largest dust sources in the port, were investigated with the specially designed filter testing apparatus for this study. The variables tested for the experiments included filter materials, dust concentrations, relative humidities, and filtration velocities. Also, the filtration characteristics of the other animal feedstuffs such as sunflower seed shell, tapioca, and palm shell were investigated to determine $K_2$ as a function of filtration velocity. The information on $K_2$ will be used to design the optimum bag filter systems for animal feedstuffs handling in the port.

Evaluation of a Rapid Sand Filter with Surface Wash and Backwash Conditions (정수장 급속여과지 역세척 수위변화와 시간에 따른 세척 효율 평가)

  • Jung, Yong-Jun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.652-656
    • /
    • 2004
  • Both surface wash and backwash are considered as one of the most important methods that can improve the filtration efficiency in the existing water treatment plant. This study has mainly focused on the improvement of filtering efficiency by controlling surface wash and backwash time, and water level before backwash (when drained up to the trough, when drained up to 10 cm above filter bed, and when drained below 10 cm filter bed). Filtration efficiency was shown a little bit of differences depending on the operating conditions like surface wash injection pressure, the distance control between filter bed and the facility, and the types of surface wash. When the water level before backwash was reached up to 10 cm below filter bed after draining, however, the filtration velocity and the turbidity removal efficiency in the filter bed was improved. When the surface wash followed by backwash is longer, it showed a similar result. Because the proper adjustment of surface washing time makes filtration efficiency higher, therefore, it is necessary to set up the backwash time moderately.

Alum Floc Attachment in Granular Media Filtration (입상여과에서 액반플럭의 부착)

  • Kim, Jinkeun
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.625-630
    • /
    • 2004
  • Granular media filtration is used almost universally as the last particle removal process in conventional water treatment plants. Therefore, superb particle removal efficiency is needed during this process to ensure a high quality of drinking water. However, every particle can not be removed during granular media filtration. Besides the pattern of particle attachment is different depending on physicochemical aspects of particles and suspension. Filtration experiments were performed in a laboratory-scale filter using spherical glass beads with a diameter of 0.55 mm as collectors. A single type of particle suspension (Min-U-Sil 5) and alum coagulation was used to destabilize particles. The operating conditions were similar to those of standard media filtration practice: a filtration velocity of 5 m/h. More favorable particles, i.e., particles with smaller surface charge, were well attached to the collectors especially during the early stage of filtration when zeta potential of particles and collectors are both negative. This selective attachment of the lower charged particles caused the zeta potential distribution (ZPD) of the effluent to move to a more negative range. On the other hand, the ZPDs of the effluent moved from more positive to less positive when the surface charge of particles was positive and this result was thought to be caused by ion transfer between particles and collectors.

Estimation of Drilling Velocity for Horizontal Wells Based on Alluvial Sediment Characteristics (충적층 입자 특성을 고려한 수평집수정 굴착 속도 추정)

  • Kim, Gyoo-Bum;Lee, Jeong-Woon;Lee, Chi-Hyung
    • The Journal of Engineering Geology
    • /
    • v.25 no.2
    • /
    • pp.273-280
    • /
    • 2015
  • Delays in horizontal well drilling when encountering heterogeneous sediments can have negative effects on the construction process at a riverbank filtration site. Grain size analysis, including calculation of the coefficient of uniformity and the coefficient of curvature, was conducted on soil samples collected at each drilling depth during the process of drilling horizontal wells. These results were then used to develop a linear equation for estimating drilling velocity using the coefficient of uniformity and the coefficient of curvature as inputs. Testing of the linear equation in other horizontal wells indicates that the equation is most appropriate for coarse-sand-sized and well-sorted sediment. Because this study was conducted in a region with small- to medium-sized streams, more data are needed from larger rivers to modify the general equation. Our results will provide better estimates of drilling velocity, in turn enabling more detailed design and more effective construction management at riverbank filtration sites.