• Title/Summary/Keyword: filtration performance

Search Result 378, Processing Time 0.022 seconds

Development of high-hydrophilic Biofilter for Decentralized Regions and Rural Communities (분산지역의 생활하수 처리를 위한 고친수성 Biofilter 개발)

  • Kwon, Tae-Young;Yoon, Chun-Gyeong;Jung, Kwang-Wook
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.678-686
    • /
    • 2006
  • The feasibility of the high-hydrophilic biofilter was examined for application in rural wastewater treatment in Korea. The intermittent trickling biofiter was developed for wastewater treatment of media and examined instantaneous wetting water and immersional wetting water. Melamin foam absorbed 120 times it's weight in water and maintained wetting status than other materials. These characteristics are improvement for application in rural areas showing large variance of amount of influent. The biofilter process was effective in treating organic pollutants; mean removal efficiencies of $BOD_5$ and TSS were above 80%. The average SS concentrations of effluent was showed below $10mg/L^{-1}$ and meet guidelines in special regions, however, the average concentration of $BOD_5$ was about $20mg/L^{-1}$. The removals of T-N and T-P were relatively less effective and removal efficiencies were below 40%. It might meet the guidelines for T-P because of low levels of influent T-P concentration. However, the T-N concentration were too high and further treatment is required. The effluent concentration of $NH_4-N$ showed a significant reduction rate about 43.8%, but part of $NH_4-N$ was transformed to $NO_2-N$ and $NO_3-N$ inside the biofilter through nitrification process. The effluent concentration of org-P was removed about 78.8% of influent concentration by filtration. Considering stable performance and effective removal of pollutant in wastewater, low maintenance, and cost-effectiveness, the hydrophilic biofilter system was thought to be an effective and feasible alternative for decentralized rural areas.

Microfiltration of Chlorella sp.: Influence of material and membrane pore size

  • Ahmad, A.L.;Yasin, N.H. Mat;Derek, C.J.C.;Lim, J.K.
    • Membrane and Water Treatment
    • /
    • v.4 no.2
    • /
    • pp.143-155
    • /
    • 2013
  • Four membranes were used to separate Chlorella sp. from their culture medium in cross-flow microfiltration (MF) experiments: cellulose acetate (CA), cellulose nitrate (CN), polypropylene (PP) and polyvinylidenefluoride (PVDF). It was found that the hydrophilic CA and CN membranes with a pore size of 1.2 ${\mu}m$ exhibited the best performances among all the membranes in terms of permeation flux. The hydrophobicity of each membrane material was determined by measuring the angle between the water (liquid) and membrane (solid). Contact angle measurements showed that deionized (DI) water had almost adsorbed onto the surfaces of the CA and CN membranes, which gave $0.00^{\circ}$ contact angle values. The PP and PVDF membranes were more hydrophobic, giving contact angle values of $95.97^{\circ}$ and $126.63^{\circ}$, respectively. Although the pure water flux increased with increasing pore diameter (0.8 < 1.2 < 3.0 ${\mu}m$) in hydrophilic CA and CN membranes, the best performance in term of filtration rate for filtering a microalgae suspension was attained by membranes with a pore size of 1.2 ${\mu}m$. The fouled membrane pore sizes and pore blocking were inspected using a scanning electron microscope (SEM). MF with large pore diameters was more sensitive to fouling that contributed to intermediate blocking, where the size of the membrane pores is almost equivalent to that of cells.

Harvesting of microalgae via submerged membranes: flux, fouling and its reversibility

  • Elcik, Harun;Cakmakci, Mehmet
    • Membrane and Water Treatment
    • /
    • v.8 no.5
    • /
    • pp.499-515
    • /
    • 2017
  • The purpose of this study was to investigate membrane fouling caused by microalgal cells in submerged membrane systems consisting of polymeric and ceramic microfiltration membranes. In this study, one polymeric (flat-sheet, pore size: $0.2{\mu}m$) and two ceramic (flat-sheet, pore size: $0.2{\mu}m$ and cylindrical, pore size: $1{\mu}m$) membranes were used. Physical cleaning was performed with water and air to determine the potential for reversible and irreversible membrane fouling. The study results showed that substantial irreversible membrane fouling (after four filtration cycles, irreversible fouling degree 27% (cleaning with water) and 38% (cleaning with air)) occurs in the polymeric membrane. In cleaning studies performed using water and air on ceramic membranes, it was observed that compressed air was more effective (recovery rate: 87-91%) for membrane cleaning. The harvesting performance of the membranes was examined through critical flux experiments. The critical flux values for polymeric membrane with a pore size of $0.20{\mu}m$ and ceramic membranes with a pore size of $0.20{\mu}m$ and $1{\mu}m$ were ${\leq}95L/m^2hour$, ${\leq}70L/m^2hour$ and ${\leq}55L/m^2hour$, respectively. It was determined that critical flux varies depending on the membrane material and the pore size. To obtain more information on membrane fouling caused by microalgal cells, the characterization of the fouled polymeric membrane was performed. This study concluded that ceramic membranes with a pore size of $0.2-1{\mu}m$ in the submerged membrane system could be efficiently used for microalgae harvesting by cleaning the membrane with compressed air at regular intervals.

Peptic Hydrolysate of Porcine Crude Myosin Has Many Active Fractions Inhibiting Angiotensin I-converting Enzyme

  • Katayama, Kazunori;Fuchu, Hidetaka;Sugiyama, Masaaki;Kawahara, Satoshi;Yamauchi, Kiyoshi;Kawamura, Yukio;Muguruma, Michio
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.9
    • /
    • pp.1384-1389
    • /
    • 2003
  • In order to clarify one of the biological functions of pork, we investigated whether a peptic hydrolysate of denatured porcine crude myosin showed inhibitory activity against angiotensin I-converting enzyme (ACE), which contributed to hypertension. Our results indicated that this hydrolysate showed relatively strong activity, and we therefore attempted to separate the involved peptides, which were considered to be active substances. To isolate these active peptides, the hydrolysate was separated using a solidphase separation, gel filtration high-performance liquid chromatography (HPLC), and two kinds of reverse phase HPLC. In each stage of separation, many fractions were detected, almost all of which showed ACE inhibitory activity. Thus, we suggested that the activity of the hydrolysate as a whole was a result of the activities of the many individual peptides. Six peaks were distinguished, with yields from 34 to 596 ppm of original crude myosin. In addition to the six peaks, many other active fractions were found throughout the separation steps, strongly suggesting that whole porcine crude myosin itself had ACE inhibitory activity. Moreover, pork as food was considered to function as an ACE inhibitory material in vivo, because pork proteins consist primarily of crude myosin, which included almost all the myofibrillar structural proteins.

Debittering of Enzymatic Hydrolysate Using Exopeptidase Active Fractions from the Argentina Shortfin Squid Illex argentinus Hepatopancreas (원양산 오징어(Illex argentinus) 간췌장 유래 Exopeptidase 분획물의 쓴맛개선 효과)

  • Kim, Jin-Soo;Kim, Min Ji;Kim, Ki Hyun;Kang, Sang In;Park, Sung Hwan;Lee, Hyun Ji;Heu, Min Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.47 no.2
    • /
    • pp.135-143
    • /
    • 2014
  • Exopeptidase active fractions from the hepatopancreas of the Argentina shortfin squid Illex argentinus, were obtained with acetone (AC 30-40%), ammonium sulfate (AS 60-70% saturation), anion exchange chromatography (AE-II, 0.2 M NaCl) and gel filtration chromatography (GF-I, 30-50 kDa) fractionation methods. A bitter peptide solution that has a bitterness equivalent to that of 2% glycylphenylalanine and prepared by tryptic hydrolysis of milk casein, was treated with the exopeptidase active fractions. The GF-I fraction was the best based on aminopeptidase activity (35.3 U/mg), percentage of recovery (30.7%) and a sensory evaluation (1.7). The amount of released amino acids increased as incubation time increased, and the bitterness of the enzyme reaction mixtures decreased. Incubation with the GF-I fraction for 24 h resulted in the hydrolysis of several peptides as revealed by the reverse-phase high performance liguid chromatography profile, with three peaks (3, 5 and 6) decreasing in area (%) and three peaks (1, 2 and 4) increasing in area (%). Therefore, the GF-I fraction appeared to be ideally suited to reduce bitterness in protein hydrolysates by catalyzing the hydrolysis of bitter peptides.

Comparison of Nitrate and Fluoride Removals between Reverse-Osmosis, Nano-Flitration, Electro-Adsorption, Elecero-Coagulation in Small Water Treatment Plants (소규모 수도시설의 역삼투(RO), 나노여과(NF), 전기흡착(EA), 전기응집(EC) 공정의 질산성 질소 및 불소 이온 제거 성능 비교)

  • Han, Song-Hee;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.2027-2036
    • /
    • 2013
  • Comparison of removal performance between reverse osmosis(RO), nanofiltration(NF), electrocoagulation(EC) and electroadsorption(EA) for removal of nitrate and fluoride often exceeded the limits of water quality in small water treatment plants. Removals of nitrate and fluoride were 72-92% and 74-85% in RO, 5-15% and 1% in NF, 99% and 44% in EA equipped with MWCNT coated electrodes, 82% and 77% in EA equipped with Cu-MWCNT electrodes, and 11-46% and 69-99% in EC. Consequently, high removals of both ions were anticipated in RO. Effective removal of both ions are possible for EC, but great production of sludge is a big burden. EA equipped with the MWCNT electrodes showed a great fluctuation in removal efficiency, and electrode stability should be upgraded.

Nutrient Removal Characteristics on Organic Material Loadings in Submerged Flat Sheet Type Sequencing Batch Membrane Reactor (침지식 평판형 연속회분식 박반응기에서 유입 유기물 부하의 변화에 따른 영양염류의 제거 특성)

  • Kim, Seung-Geon;Lee, Ho-Won;Kang, Yeung-Joo
    • Membrane Journal
    • /
    • v.20 no.3
    • /
    • pp.241-248
    • /
    • 2010
  • The effect of organic material loadings on nutrient removal characteristics were investigated in sequencing batch reactor, in which a flat sheet type microfiltration membrane with a pore size of $0.4\;{\mu}m$ was submerged. Three organic concentrations of 200 mg/L (Run-1), 400 mg/L (Run-2) and 800 mg/L (Run-3) were carried out continuously to identify their effect on the filtration performance and nutrient removal. The removal efficiencies of T-N and T-P were increased with the increase of COD/N and COD/P. The T-N removal efficiencies of Run-1, Run-2 and Run-3 were 28.1, 32.6 and 90.4%, the average concentrations of T-N in permeate were 32.0, 30.0, and 4.3 mg/L, respectively. The T-P removal efficiencies of Run-1, Run-2 and Run-3 were 13.6, 35.3 and 93.1%, the average concentrations of T-P in permeate were 3.11, 2.33, and 0.25 mg/L, respectively.

Effect of coagaulation on ceramic microfiltration membrane fouling (응집공정이 세라믹 정밀여과막 파울링에 미치는 영향)

  • Hwang, Young Jin;Lim, Jae Lim;Choi, Young Jong;Wang, Chang Gun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.459-469
    • /
    • 2009
  • It is well known that coagulation pretreatment can reduce foulants prior to membrane filtration. The purpose of this research was to investigate the effects of coagulation on fouling of ceramic microfiltration membrane($0.1 {\mu}m$) using pilot plant of $150m^3/day/train$ capacity. Train A membrane system has pretreatment process of ozonation and coagulation while train B has only coagulation. Two types of coagulation operation were investigated: back mixer(rapid mixing with or without slow mixing) which is a conventional mechanically stirred mixer and an inline static mixer. Ozone dose rate for train A was 1 mg/L and ozone contact time was 12 min. The coagulation dose(PACl 10% as $Al_2O_3$) rate was changed 20~40 mg/L according to experimental schedule. In this experimental conditions, the coagulation of back mixer type with rapid mixing(GT=72,000) and slow mixing(GT=45,000) was the best effective in reduction of ceramic membrane fouling regardless preozonation. Especially, the effect of inline static mixer was sensitive to change in water quality. Ozonation mainly affected irreversible fouling rather than reversible fouling in accordance with less adsorption of NOM on the membrane surface. Thus, the increase rate of the nomalized TMP(trans membrane pressure) at $25^{\circ}C$ for train A was relatively lower than that of train B under same coagulation process with same coagulant dosage. The best performance of ceramic membrane appeared in case of combined process with ozonation, therefore this integrated process is able to archive less coagulant dosing and secure a stability of ceramic membrane system.

The Effect of pH and Temperature on Lysozyme Separation in Ion-exchange Chromatography (이온교환크로마토그래피에서 라이소자임 분리에 미치는 pH와 온도 영향)

  • Ko, Kwan-Young;Kim, In-Ho
    • Korean Chemical Engineering Research
    • /
    • v.52 no.1
    • /
    • pp.98-105
    • /
    • 2014
  • Lysozyme amounts to 0.3% in egg white and functions as an agent of cell lysis and activator of tissue reconstruction. Ion exchange chromatography is the most useful method of separation among affinity chromatography, ion exchange chromatography, and ultra-filtration. The aim of present study is to find the optimum pH and temperature for the separation of lysozyme in egg white within cation exchange gel filled glass column. And we compared results of experiments with those of simulations. Phosphate buffer was used, and pH and temperature were varied as 5~7 and $25{\sim}40^{\circ}C$ respectively. RP-HPLC was the tool for the retention time identification and quantitative analysis of lysozyme. OriginPro 8 measured the peak area of lysozyme chromatogram and quantified the eluted lysozyme. Largest amount of lysozyme was separated under the conditions of pH 5 and T $25^{\circ}C$.

Performance Study on Pilot-scale Constructed Wetlands in order to Restore Contaminated Stream (오염하천의 정화를 위한 파일럿 규모의 인공습지 적용)

  • Kim, Seung-Jun;Choi, Yong-Su;Bae, Woo-keun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.546-556
    • /
    • 2006
  • The purpose of this study is to improve the polluted stream water quality by pilot-scale five different constructed wetlands (CWs). Cell 1 to 3 are newly designed 2SFCW (Surface-subsurface flow CW) with 1 to 3 flow shifters (FS) in the middle of the wetland system. Cell 4 and 5 are control CW (CCW), but Cell 5 is the same type as Cell 3. The FS, which converts the route of surface and subsurface flow between two wetlands connected in series, was able to enhance the treatability of TN via nitrification and denitrification and of SS due to filtration and sedimentation. The void fraction and dispersion number of Cell 1, 2 and 3 obtained from the RTD analysis were found to be 0.73 and 0.17, respectively. COD and TP removal efficiencies of Cell 1 to 3 were similar to that of Cell 4 and 5. SS removal efficiencies of Cell 1 to 3 and 5 with FS were 5-10% higher than that of Cell 4 without FS. TN removal efficiencies of Cell 1 to 3 were 3-14% higher than that of Cell 4 and 5. The average $R^2$ values of COD, SS, TN and TP obtained from nonlinear regression analysis were similar to the results of other researchers.