• 제목/요약/키워드: filtration performance

검색결과 375건 처리시간 0.023초

벽유동 방식 담체를 사용하는 SCR 촉매 반응기에서 재 퇴적이 변환 효율에 미치는 영향에 대한 연구 (Impact of Ash Deposit on Conversion Efficiency of Wall Flow Type Monolithic SCR Reactor)

  • 박수열
    • 동력기계공학회지
    • /
    • 제17권1호
    • /
    • pp.27-35
    • /
    • 2013
  • SCR (Selective Catalytic Reduction) on DPF (Diesel Particulate Filter) is a multi-functional after-treatment device which integrates soot filtration and DeNOx function into a single can. Because of its advantage in package and cost, the SCR on DPF is considered as a potential candidate for future application. It inherently employes wall flow type monolithic reactor so ash included in exhaust gas may deposit inside the inlet channel of this device. This study is intended to identify the impact of ash deposit on SCR reaction under wall flow type monolithic reactor. Simulation approach is used so relevant species transport equations for wall flow type monolith is derived. These equations can be solved together with momentum conservation equations and give solution for conversion performance. Both ash deposit and clean catalyst case are simulated and comparison of these two cases gives an insight for the impact of ash deposit on conversion performance. Ash deposit can be classified as ash layer and ash plug. and impact of ash deposit is described along with different morphology of ash deposit.

교반식 퇴비화 암모니아가스의 부숙퇴비를 이용한 탈취성능 특성 (Performance Characteristics of Matured Compost Biofiltration of Ammonia Gas from the Agitated Composting)

  • 홍지형;박금주
    • 한국축산시설환경학회지
    • /
    • 제8권1호
    • /
    • pp.1-8
    • /
    • 2002
  • 실제 규모의 반밀폐 교반통기식 퇴비화 시스템에서 돈분과 톱밥의 혼합물을 퇴비화하는 과정에서 발생하는 암모니아가스의 탈취처리를 위하여 개방식 바이오필터 시스템을 제작하고 바이오필터로서 부숙퇴비를 이용하여 탈취시험을 수행하였다. 퇴비화 및 탈취과정에서 재료의 이화학적 특성 및 암모니아가스의 발생량을 측정하여 퇴비화의 특성 및 바이오필터 시스템의 성능을 분석하였다. 바이오필터의 암모니아가스 탈취효율은 2개월 평균 84%로 나타났으며 탈취재를 통과한 후의 암모니아가스의 농도는 최대 45ppm 이하로 나타나 허용농도 (50ppm) 범위에 있었다. 부숙퇴비는 교반통기식 퇴비화 시스템에서 발생하는 암모니아가스의 탈취재로 활용할 수 있는 것으로 나타났다.

  • PDF

A column study of effect of filter media on the performance of sand filter

  • Kim, Tae-hoon;Oh, Heekyong;Eom, Jungyeol;Park, ChulHwi
    • Membrane and Water Treatment
    • /
    • 제11권4호
    • /
    • pp.247-255
    • /
    • 2020
  • Sand filter is a key unit process for particle removal in water purification treatments. Its long-standing use is due to on-site customized retrofit. Proper selection of filter media is one of the retrofit approaches to improve filter performance. This study described a series of controlled laboratory column tests and examined the effects of media property on filtration and backwash. When sand media of 0.51 mm in effective size was replaced by sand of 0.60 mm, the filter run increased up to 5 times in the given bed depth. The change of media property required an increase of backwash rate by 0.05 m/min to satisfy the requirement of bed expansion, more than 20%. When the anthracite was changed with lower effective size and uniformity coefficient, correlation with sand in the filter bed could be satisfied within the permissible error between media and bulk characteristics. Besides, this selection resulted in a well-stratified configuration of media layers after bed expansion. The column study showed that the correlation of property between the dual media had a significant effect on the filter productivity and backwash interval.

멤브레인 케이크 레이어 형성 과정 모사를 위한 수치 모델의 개발 (Development of a Numerical Model for Cake Layer Formation Process on Membrane)

  • 김경호;신재호;이상환;이주희
    • 한국유체기계학회 논문집
    • /
    • 제14권6호
    • /
    • pp.35-44
    • /
    • 2011
  • Membrane filtration has become firmly established as a primary process for ensuring the purity, safety and efficiency of treatment of water or effluents. Several researches have been performed to develop and design membrane systems in order to increase the accuracy and performance of the processes. In this study, a lattice Boltzmann method for the cake layer has been developed using particle dynamics based on an immersed boundary method and the cake layer formation process on membrane has been numerically simulated. Case studies including various particle sizes were also performed for a microfiltration process. The growth rate of the cake layer thickness and the permeation flow rate along the membranes were predicted. The results of this study agreed well with that of previous experiments. Effects of various particle diameters on the membrane performance were studied. The cake layer of a large particle tended to be growing fast and the permeation flow going down rapidly at the beginning. The layer thickness of a small particle increased constantly and the flow rate was smaller than that of the large particle at the end of simulation time.

전처리 MF의 다양한 역세 공정을 적용한 하수재이용 파일럿 플랜트 연구 (Study of MF membrane as pretreatment option using various backwash process from wastewater reuse pilot plant)

  • 박광덕;박찬수;이창규;김종오;최준석
    • 상하수도학회지
    • /
    • 제30권3호
    • /
    • pp.335-341
    • /
    • 2016
  • Various studies have forwarded an outstanding wastewater effluent treatment systems toward securing sustainable supply of water sources. In this paper, a broad overview of the performance of MF membrane as pretreatment option for wastewater reuse will be presented based on the literature survey and experiments conducted over the wastewater reuse pilot plant. The pilot plant was operated with a continuous data acquisition for about 300days under various chemical enhanced backwash (CEB) system with subsequent treated water quality analysis. Accordingly, assessment of the effluent revealed that the pretreated water is suitable enough to be used as an input for Reverse Osmosis (RO) unit and significant effect of CEB and concentration of NaOCl is also conceived from the analysis. Moreover, it's also observed that the application of various CEB condition over long operational hours induced a constant declination of overall performance of MF membrane.

정전 방식 디젤 PM 포집 장치 성능 및 엔진 적용성 평가 (Evaluation on Performance of an Electrostatic Diesel PM Trap Device and Its Application to Diesel Engine After-treatment)

  • 김학준;한방우;김용진
    • 한국자동차공학회논문집
    • /
    • 제16권6호
    • /
    • pp.176-183
    • /
    • 2008
  • Performance of electrostatic diesel PM filtration systems (E-DPS) with different types has been tested using the carbon particles generated by spark discharge in laboratory. Among the five electrostatic precipitators, the multiple wires cylindrical E-DPS with the highest collection efficiency and relatively lower differential pressure at the flow rate of $1\;m^3$/min, as an applicable device to diesel engine as an after treatment system, has been combined with another collection cylinder to improve the collection efficiency of diesel particulate matters generated from diesel engines. The multiple wires cylindrical E-DPS combined with the cylindrical collector showed the collection efficiency of more than 60% at the engine speed of 2,000 rpm with the engine loads of 25 and 50%.

정전형여과집진방식에서 여과특성에 관한 연구 (A Study on Filtration Performance Test with Electrostatically Enhanced Fabric Filter)

  • 천중국;박출재;최금찬
    • 한국대기환경학회지
    • /
    • 제11권4호
    • /
    • pp.361-367
    • /
    • 1995
  • This study has been carried out to investigate the filteration performance of Electrostatically Stimulated Fabric Filter(ESFF) at high temperature condition. The electric field was maintained parallel to the fabric surface. The benefits of ESFF are lower residual pressure drop, improvement of fine particle removal efficiency and increasing reduced rate of pressure drop during a filteration cycle, stable operation at higher filtering velocities. According to the variance of filtering velocities and dust loadings, the results are summarized as follows; By imposing an electric field on the filter, the reduced rate of pressure drop was 7.sim.18% at room temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Under the electric field around the filter, the reduced rate of pressure drop was 10.sim.35% at high temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Most of all, at high temperature, the value of reduced rate of pressure drop was resulted to 25%. Also the collecting efficiency was shown clearly improved. By the SEM photo analysis, the number of penetrated particles at the Conventional Fabric Filter was approximately two times that of Electrostatically Stimulated Fabric Filter.

  • PDF

A novel method of surface modification to polysulfone ultrafiltration membrane by preadsorption of citric acid or sodium bisulfite

  • Wei, Xinyu;Wang, Zhi;Wang, Jixiao;Wang, Shichang
    • Membrane and Water Treatment
    • /
    • 제3권1호
    • /
    • pp.35-49
    • /
    • 2012
  • In membrane processes, various agents are used to enhance, protect, and recover membrane performance. Applying these agents in membrane modification could potentially be considered as a simple method to improve membrane performance without additional process. Citric acid (CI) and sodium bisulfite (SB) are two chemicals that are widely used in membrane feed water pretreatment and cleaning processes. In this work, preadsorptions of CI and SB were developed as simple methods for polysulfone ultrafiltration membrane modification. It was found that hydrogen bonding and Van Der Waals attraction could be responsible for the adsorptions of CI and SB onto membranes, respectively. After modification with CI or SB, the membrane surfaces became more hydrophilic. Membrane permeability improved when modified by SB while decreased a little when modified by CI. The modified membranes had an increase in PEG and BSA rejections and better antifouling properties with higher flux recovery ratios during filtration of a complex pharmaceutical wastewater. Moreover, membrane chlorine tolerance was elevated after modification with either agent, as shown by the mechanical property measurements.

PAC 전처리 시 수소이온 농도에 따라 발생 가능한 알루미늄 종에 의한 나노여과막 성능 연구 (Effects of polymeric Al and hydrolysis products of PAC at different pH on performance of nanofiltration with PAC coagulation pretreatment)

  • 최양훈;권지향
    • 상하수도학회지
    • /
    • 제24권1호
    • /
    • pp.15-24
    • /
    • 2010
  • Coagulation can be used for pretreatment of NF membrane filtration. Foulants such as organic matter and particulate can be removed effectively with the process while high flux recovery is maintained. Recently various types of polyaluminium coagulants including polyaluminium chloride(PAC) are commercially available for water treatment. This study examines effects of polymeric Al and hydrolysis products of PAC on nanofiltration membrane performance. Dominant hydrolysis products were polymeric Al, $Al(OH)_3$, and ${Al(OH)_4}^{-1}$ at acidic, neutral, and alkaline pH conditions, respectively. Under acidic pH condition, flux decline was increased with increasing PAC concentrations, possibly due to polymeric Al adsorption on membrane pore and/or surfaces. For neutral and alkaline pH conditions, little flux decline was observed with increasing PAC concentrations except the highest ${Al(OH)_4}^{-1}$ concentration, with which rapid flux decline was shown. Removal of ionic matters was also varied with pH conditions in this study. Especially, conductivity removal was substantially low and $Ca^{2+}$ concentration in the permeate was quite high at neutral pH condition.

탄소나노튜브 소재의 정밀 수동소자 적용을 위한 한계 정격전력 용량에 관한 연구 (A Study on the Limited Rate Power Capacity for Applications for Precision Passive Devices Based on Carbon Nanotube Materials)

  • 이선우
    • 한국전기전자재료학회논문지
    • /
    • 제35권3호
    • /
    • pp.269-274
    • /
    • 2022
  • We prepared carbon nanotube (CNT) paper by a vacuum filtration method for the use of a chip-typed resistor as a precision passive device with a constant resistance. Hybrid resistor composed of the CNT resistor with a negative temperature coefficient of resistance (T.C.R) and a metal alloy resistor with a positive T.C.R could lead to a constant resistance, because the resistance increase owing to the temperature increase at the metal alloy and decrease at the CNT could counterbalance each other. The constant resistance for the precision passive devices should be maintained even when a heat was generated by a current flow resulting in resistance change. Performance reliabilities of the CNT resistor for the precision passive device applications such as electrical load limit, environmental load limit, and life limit specified in IEC 60115-1 must be ensured. In this study, therefore, the rated power determination and T.C.R tests of the CNT paper were conducted. -900~-700 ppm/℃ of TCR, 0.1~0.2 A of the carrying current capacity, and 0.0625~0.125 W of the rated power limit were obtained from the CNT paper. Consequently, we confirmed that the application of CNT materials for the precision hybrid passive devices with a metal alloy could result in a better performance reliability with a zero tolerance.