• 제목/요약/키워드: filtration performance

검색결과 375건 처리시간 0.032초

The Evaluation of Performance Limiting Factors for the Optimization of Drinking Water Treatment (정수장 최적화를 위한 성능제한인자 평가에 관한 연구)

  • Kim, Jeong Hyun;Bae, Chul Ho;Park, No Suk;Moon, Yong Taik;Lee, Sun Ju;Kown, Soon Buhm;Ahn, Hyo Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • 제19권1호
    • /
    • pp.78-91
    • /
    • 2005
  • Performance limiting factors (PLFs) derived from 161 drinking water treatment plants (DWTPs), assessed by International Technical Diagnosis & Assistance Center, were analyzed and evaluated in more detail in this study. In order to conduct study, 161 DWTPs were divided into five categories depending on their capacity, and into twelve groups according to processes and facilities. From the results of analysis, PLFs and their distribution ratio derived from each category were significantly different. Filtration was the most important performance limiting process in all DWTPs of five categories, and the PLFs in filtration were backwashing velocity, media configuration, bed depth, and formation of mud-ball. The PLFs in coagulation-flocculation process were found out to be coagulant dosage, mixing speed, mechanical problems, and others in the order of frequency of occurrence. Also, insufficient disinfection ability that is resulted from insufficient hydraulic detention time and improper chlorine dose and injection point, is the most significant among PLFs in a clear well. In the case of sedimentation, inappropriate baffle structure and excessive upward velocity were PLFs. In addition, the results showed that high turbid water and low alkalinity in a rainy season, ferric and manganese ions, and ammonia nitrogen have been contributed significantly on the performance of DWTPs.

Filtration Performance Evaluation of Various Respiratory Face Masks Against Sub-Micron Particles (다양한 호흡기 보호용 면체 마스크의 서브 마이크론 입자에 대한 여과 성능 평가)

  • Zainul Alim Ali Murtadlo;Cho Hee-Joo;Park Hyun-Seol
    • Particle and aerosol research
    • /
    • 제19권1호
    • /
    • pp.1-11
    • /
    • 2023
  • Respiratory face masks are protective facepieces that are designed to filter inhaled air. They are easy-to-use devices that can protect the wearer against various hazardous particles in the air. Respiratory face masks also prevent the spread of viruses and bacteria-containing droplets that are released from the coughing or sneezing of the infected people. During the COVID-19 pandemic, various types of face masks have circulated on the market. Their ability to filter sub-micron particles, which are the sizes of harmful particulate matter and airborne viruses, needs to be investigated. Their breathability, the easiness of breath through the mask, also needs to be considered. In this study, wwe evaluated the performance of filters used for different types of face masks certified by different standards including Korean (KF94, KF80, KF-AD), USA (N95), and Chinese (KN95) standards. We also tested the filters of nanofiber masks and surgical masks for which there are no standards for filtration test. The N95 mask filters showed the highest quality factor for capturing virus-sized particles. The other types of mask filters have acceptable performance except for nanofiber mask filters whose performance is very low.

Application of coagulation pretreatment for enhancing the performance of ceramic membrane filtration (세라믹 막여과의 성능향상을 위한 응집 전처리의 적용)

  • Kang, Joon-Seok;Song, Jiyoung;Park, Seogyeong;Jeong, Ahyoung;Lee, Jeong-Jun;Seo, Inseok;Chae, Seonha;Kim, Seongsu;Kim, Han-Seung
    • Journal of Korean Society of Water and Wastewater
    • /
    • 제31권6호
    • /
    • pp.501-510
    • /
    • 2017
  • In this study, it is estimated that ceramic membrane process which can operate stably in harsh conditions replacing existing organic membrane connected with coagulation, sedimentation etc.. Jar-test was conducted by using artificial raw water containing kaolin and humic acid. It was observed that coagulant (A-PAC, 10.6%) 4mg/l is the optimal dose. As a results of evaluation of membrane single filtration process (A), coagulation-membrane filtration process (B) and coagulation-sedimentation-membrane filtration process (C), TMP variation is stable regardless of in Flux $2m^3/m^2{\cdot}day$. But in Flux $5m^3/m^2{\cdot}day$, it show change of 1-89.3 kpa by process. TMP of process (B) and (C) is increased 11.8, 0.6 kpa each. But, the (A) showed the greatest change of TMP. When evaluate (A) and (C) in Flux $10m^3/m^2{\cdot}day$, TMP of (A) stopped operation being exceeded 120 kpa in 20 minutes. On the other hand, TMP of (C) is increased only 3 kpa in 120 minutes. Through this, membrane filtration process can be operated stably by using the linkage between the pretreatment process and the ceramic membrane filtration process. Turbidity of treated water remained under 0.1 NTU regardless of flux condition and DOC and $UV_{254}$ showed a removal rate of 65-85%, 95% more each at process connected with pretreatment. Physical cleaning was carried out using water and air of 500kpa to show the recovery of pollutants formed on membrane surface by filtration. In (A) process, TMP has increased rapidly and decreased the recovery by physical cleaning as the flux rises. This means that contamination on membrane surface is irreversible fouling difficult to recover by using physical cleaning. Process (B) and (C) are observed high recovery rate of 60% more in high flux and especially recovery rate of process (B) is the highest at 95.8%. This can be judged that the coagulation flocs in the raw water formed cake layer with irreversible fouling and are favorable to physical cleaning. As a result of estimation, observe that ceramic membrane filtration connected with pretreatment improves efficiency of filtration and recovery rate of physical cleaning. And ceramic membrane which is possible to operate in the higher flux than organic membrane can be reduce the area of water purification facilities and secure a stable quantity of water by connecting the ceramic membrane with pretreatment process.

A Study on the Performance of the Diesel Particulate Filter made of Porous Metal with Fe-based Fuel Additive (Fe 첨가제를 적용한 금속분말 필터의 포집 및 재생 특성에 관한 연구)

  • Park, S.H.;Chun, K.M.;Cho, G.B.;Jeong, Y.I.;Park, Y.L.
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.802-806
    • /
    • 2001
  • Diesel particulate trap is the most reliable system to reduce the particulate matters from diesel engine. Filter is the core component of DPF and ceramic monolith type is dominantly used, which is expensive and fragile relatively at thermal shock. Porous metal filter, which has superior thermal characteristics and low cost, was tested in order to analyze the regeneration performance by using with ferrocene additive. This filter showed the 72% filtration efficiency, additives itself diminished 48% of PM from engine out emission, and final PM reduction ratio of 89% was achieved by DPF system with D-13 test mode.

  • PDF

A Study on Development of the Wet Type Filter for Combustion Air of Diesel Engine (디젤엔진 연소공기 습식여과기의 개발에 관한 연구)

  • Kim, Yong-Seok;Park, Sung-Ho;Yang, Soon-Young
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • 제17권1호
    • /
    • pp.158-164
    • /
    • 2008
  • In this paper, the performance of wet type filter for diesel engine combustion air has been studied with effects of air temperature, humidity, and pressure. After experiments are performed without diesel engine, it has been investigated the applicability to diesel engine. Wet type filter for diesel engine combustion air had advantages that it is not necessary to change air filter and that engine exhaust gas is environmentally friendly due to low NOx and particulate emission. Also, the filtration performance has been carried out with smoke shell.

Optimization of Operation and Backwashing Condition for an Upflow Stormwater Filtration System Utilizing Ceramic Media (세라믹 여재를 활용한 상향류식 여과형 비점오염저감시설의 최적 운전 및 역세척 조건)

  • Hwang, Yuhoon;Seo, Younggyo;Kim, Hyowon;Roh, Kunwan;Shin, Hyunsang;Kim, Dogun
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제39권8호
    • /
    • pp.478-488
    • /
    • 2017
  • Stormwater filtration is widely used for the urban runoff treatment. However, intensive maintenance and lack of information about the performance have resulted in an increased need of proper evaluation. In this study, the performance of an upflow stormwater runoff filtration system, consisting of a supporting unit and a filtration unit filled with a ceramic media, was investigated. The maximum head loss increase was about 3 cm under the suspended solid (SS) load of $30kg/m^2$ and the SS removal was more than 96%, when the filtration velocity was 20-40 m/h. The head loss and the porosity of the media can successfully be described by a power model. It was confirmed that the a significant amount of SS can effectively be removed at supporting unit, minimizing SS load to the filter media bed. Several backwashing strategies have been tested to establish the optimum condition. It was found that the stagnant water discharge is important to minimize the SS release immediately after backwashing. Also, the filter bed loaded with $400-450kg/m^2$ SS can almost completely be washed to reduce the head loss to the that of empty bed. The results in this study indicate that the upflow ceramic media filter is an excellent alternative to stormwater treatment, with high SS removal and long lifespan.