• 제목/요약/키워드: filtration efficiency

검색결과 513건 처리시간 0.031초

주름필터를 적용한 CYBAGFILTER®의 여과성능 특성 (Dust Filtration Characteristics of Pleated Filter Bags Installed in CYBAGFILTER®)

  • 박영옥;노학재;이영우
    • 한국대기환경학회지
    • /
    • 제24권4호
    • /
    • pp.483-491
    • /
    • 2008
  • The filtration characteristics of $CYBAGFILTER^{(R)}$ unit with pleated filter bags were evaluated by comparing the performance of the unit with the lower part of cyclone shape with that of the unit with conventional lower part. Results from the test were also compared with those from the previous research with the $CYBAGFILTER^{(R)}$ in which round filter bags were installed. $CYBAGFILTER^{(R)}$ is the unit which combines the centrifugal separation mechanism and the fabric filtration mechanism in a single unit for efficient removal of particulate matters. The pleated filter bags are made of pleated fabric with an extension of the filtration area about 3 times compared with the conventional round filter bags. The results from the test using pleated filter bags showed an overall collection efficiency of over 99.9% regardless of the shape of lower part installed. When the lower part of cyclone shape was installed, the filter cleaning interval was over 2 times longer compared with that when the conventional lower part was installed. At the same conditions of filtration velocity and filter pressure drop, the $CYBAGFILTER^{(R)}$ with the lower part of cyclone shape, in which the pleated filter bags are installed, can be operated with a flow rate of round 3 times higher than that with conventional round filter bags.

Alum 주입 메쉬 침지 여과분리형 생물반응조의 운전 특성과 인 제거 (Phosphorus Removal and Operating Performance of Mesh Filtration Bio-reactor with the Addition of Alum)

  • 정용준;민경석
    • 한국물환경학회지
    • /
    • 제21권5호
    • /
    • pp.458-463
    • /
    • 2005
  • Considering the characteristics of a filtration bio-reactor equipped with a mesh filter module which can effectively maintain high concentration of biomass and enhanced solid-liquid separation performance, the hybrid process of filtration bio-reactor combined with coagulation was investigated to get improved filtration characteristics as well as water quality in this work. Two bio-reactors (Run-1 & Run-2) were operated under the following conditions: working volume of 25 L, continuous loading of a synthetic wastewater (BOD: 200 mg/L, T-N: 50 mg/L, T-P: 5 mg/L), where an appropriate amount of alum ($Al_2(SO_4)_3{\cdot}18H_2O$) was added once a day into the reactor (Run-2). In the system without using a alum (Run-1), the clogging of mesh filter module was observed two times through 85 days of whole operation. Meanwhile, the filter module did not clog even at higher MLSS concentration (6,000~12,000 mg/L) and the stable filtration (0.7 mid) was continued in the case of using a alum. Due to the stable formation of cake layers, BOD and SS were shown below 6 and 3 mg/L, respectively. T-P and pH of the effluent were changed because of the intermittent addition of the alum. In the case of Al/P=2.5, the average T-P removal efficiency per day was 85.2% and the average T-P concentration of the effluent was 0.3 mg/L. However, the removal efficiency of phosphate was influenced by pH in the reactor.

입상여과에 의한 비균일 부유입자 제거공정 모사 (Simulation of poly-dispersed suspended solid removal by deep-bed filtration)

  • 주창업
    • 청정기술
    • /
    • 제7권3호
    • /
    • pp.161-167
    • /
    • 2001
  • 입상여과를 이용하여 현탁액에 포함되어 있는 비균일 입자를 제거하는 공정에 대한 모델을 제시하였고 전산모사를 통하여 여과가 진행됨에 따라 입자 제거 능력을 조사하였다. 여과재 표면에 포집된 입자들은 여과재의 세공을 좁게 하며 따라서 여과가 진행됨에 따라 입자제거능력이 증가하게 된다. 여러 가지 크기의 입자들이 포함된 현탁액의 여과 공정의 경우에는 입자들의 부피평균에 의한 단일입자의 경우보다 향상된 여과효율을 나타내었다. 이는 크기가 큰 입자들이 세공표면에서 추가의 여과재 역할을 하며 또한 유체가 흐르는 세공을 좁게 하므로서 작은 입자들이 여과재의 표면과 접촉하는 기회를 증대시켜 결과적으로 총괄 여과효율의 증가를 나타낸다.

  • PDF

정수처리에서 생물학적 망간처리 (Biological Manganese Removal in Water Treatment)

  • 김범수;윤재경;안효원;김충환
    • 상하수도학회지
    • /
    • 제20권1호
    • /
    • pp.44-52
    • /
    • 2006
  • Bio-filtration processes using honeycomb tubes (process 1) and aeration and manganese-sand filtration (process 2) were evaluated for the biological manganese removal efficiency. The concentration of manganese at effluent was stabilized after 20days operation in process 1. It was estimated the required time for attaching and growing microorganisms to honeycomb tubes. In long term of operation periods, manganese removal efficiency was dropped for the excessively attached biofilm and manganese dioxide to honeycomb tubes. It took several days for normal operation in process 2, after that manganese removal efficiency was increased to 98% and stabilized for 1.5 years. Microorganisms in process 1 and 2 were isolated and cultured to characterize manganese-oxidizing bacteria. Among the four types of colony, light brown colony was turned blue color by leuco crystal violet spot test. Stenotropomonas genus, known as manganese-oxidizing bacteria, was identified by 16S rDNA partial sequencing analysis which was isolated in process 1 and 2. For the biological treatment to remove manganese, these two considerations are important. One is to choose the proper media attaching manganese oxidant, another one is to define the cultural condition of isolated manganese-oxidizing bacteria.

정수처리공정 전처리로서의 공극제어 섬유여과기(PCF)의 적용 (Application of Pore-controllable Fiber Filter(PCF) as a Pretreatment for Water Treatment Process)

  • 이철우;이병구;이일국;이순화;배상대;강임석
    • 상하수도학회지
    • /
    • 제20권2호
    • /
    • pp.235-244
    • /
    • 2006
  • A PCF(Pore Controllable Fiber Filter) process was applied as a pretreatment of water treatment for reduction of turbidity. The experimental results obtained from the PCF showed that the removal efficiency of turbidity without coagulation was around over 70 percent. However, the removal efficiency of turbidity by the coagulation-PCF process was high as much as over 95%. Thus, the coagulation pretreatment was required for the better operation of the PCF. The SEM (Scanning Electron Microscope) images of fiber before and after filtration showed that the filtration mechanism of PCF filter is both controlling attachment mechanism and Sieving mechanism through fiber pore. For the coagulation-PCF process, optimum dosage of coagulant was needed for the economical operation, and for this, determining the optimum dosage by using a filter column test. Also only 16mg/L of alum was used to obtain high algae removal efficiency over 90%. Therefore, it can be concluded that coagulation-PCF process is very effective pretreatment process for algae removal.

입자분리를 위한 여과방식에 따른 비용-효율 분석 (From Deep Bed Filter to Membrane Filtration: Process Intensification, Cost and Energy Considerations)

  • ;권대영
    • 상하수도학회지
    • /
    • 제19권2호
    • /
    • pp.144-148
    • /
    • 2005
  • The industrial development of large scale deep bed filters has been a very important step in the process of drinking water production and more recently in the tertiary treatment of wastewater. The target of deep bed filtration is the retention is the retention of small particles generally smaller than 30 microns at relatively small concentration, generally less than 30 mg/l from natural water (surface water or aquifers) or secondary treated wastewater. The relation between the retention efficiency and the characteristics of the particles has been extensively studied experimentally and through different models of retention. During the last years the development of new technologies (fiber filter, membrane modules) lead to more intensive processes compared to conventional sand filtration. Fiber filters can combine intensification with a decrease in specific energy needed however they cannot be operated under gravity like sand filters. Membrane filters (UF or MF) are much more intensive and efficient than sand filters. The specific energy needed is not so high (about $0.1Kwh/M^3$) but is higher than sand or fiber filter. A Life Cycle Analysis (LCA) has to be made for a complete comparison between these technologies taking in account that the efficiency of particle retention obtained by membrane filters is unique.

Performance assessment of HEPA filter against radioactive aerosols from metal cutting during nuclear decommissioning

  • Lee, Min-Ho;Yang, Wonseok;Chae, Nakkyu;Choi, Sungyeol
    • Nuclear Engineering and Technology
    • /
    • 제52권5호
    • /
    • pp.1043-1050
    • /
    • 2020
  • Radioactive aerosols are produced during the cutting of contaminated and activated metals. They must be collected and removed by a high-performing filtration system before releasing to the environment from the decommissioning workplace. The filtration system requires regular replacement to ensure the sufficient removal of radioactive aerosols because its filtration efficiency gradually decreases. This study evaluates the efficiency and lifetime of filters while cutting metals by using a plasma arc cutter. Particularly, this study considers the aerodynamic diameter distribution of number and mass concentrations for aerosols from 6 nm to 10 ㎛ when evaluating the performance of filters. After 20 time reuses for cutting operation performed in a cutting chamber, the removal efficiency is reduced from over 99 to below 93% at 2 ㎛. The results are used to analyze the lifetime of filters, the frequencies of their replacements, and impact on internal radiation dose.

PTFE membrane이 코팅된 여과백의 off-line 탈진시 미세먼지 집진 특성 (Filtration Characteristics of Paticulate Matter at Bag Filters Coated with PTFE Membrane During Off-Line Pulsing)

  • 김정훈;문일식;황민영;김량균;고대권
    • 대한환경공학회지
    • /
    • 제39권7호
    • /
    • pp.391-402
    • /
    • 2017
  • 근래에 미세먼지가 대기환경 관련하여 이슈가 되고 있으며, 초미세먼지의 효과적인 집진을 위하여 대용량화가 용이한 여과집진기가 상업적으로 사용될 수 있는지에 대한 평가가 필요하다. 실험실 규모의 여과집진 장치를 제작하여, PTFE 재질의 부직포 여과백 또는 PTFE membrane이 코팅된 PTFE 재질의 부직포 여과백에서의 미세먼지 집진특성을 파악하기 위하여 집진실험을 수행하였다. 실험 변수로 여과속도, 투입 먼지 농도, 입도분포가 다른 먼지 종류 등을 사용한 실험에서, 여과속도가 낮을수록, 먼지 투입농도가 높을수록, 평균입도가 클수록 집진효율이 높았으며, 여과속도가 높고, 먼지 투입농도가 높을수록 압력손실이 높게 나타났다. Pore size가 상대적으로 작은 PTFE membrane이 코팅된 여과백을 사용한 경우, 코팅이 되지 않은 여과백을 사용한 경우에 비하여 집진효율이 높고, 표면여과에 따른 포집 먼지층 저항계수가 낮아져 압력손실이 낮게 나타났다. PTFE membrane이 코팅된 여과백을 사용하여 off-line 탈진을 수행할 경우, 적정 여과속도 범위 내에서 $PM_{2.5}$에 대한 집진효율이 99.99% 이상으로 매우 높게 유지됨에 따라, 여과집진기를 사용하여 초미세먼지를 효과적으로 집진할 수 있음을 확인하였다.

지하역사 승강장 공조 시스템 필터용 항바이러스 코팅 성능 및 재생 성능 평가 (Development of Optimal Antiviral Coating Method for the Air Filtration System of Subway Station)

  • 박대훈;황정호;신동호;김영훈;이건희;박인용;김상복;홍기정;한방우
    • 한국입자에어로졸학회지
    • /
    • 제18권1호
    • /
    • pp.9-21
    • /
    • 2022
  • In this study, a novel antiviral coating method for the air filtration system of subway station was investigated. Using dry aerosol coating process, we developed a high-performance antiviral air filter with spark discharger and carbon brush type ionizer. Silver nanoparticles were produced by a spark discharge generation system with ion injection system and were used as antiviral agents coated onto a medium grade air filter. The pressure drop, filtration efficiency, and antiviral ability of the filter against aerosolized MS2 virus particles as a surrogate of SARS-CoV-2 virus were tested with dust contamination. Dust contamination caused the increase of the filtration efficiency and pressure drop, while the antiviral agents (in this study, silver nanoparticles) coating did not have any significant effect on the filtration efficiency and pressure drop. Using these properties, we suggested a novel method to maximize the antiviral performance of the antiviral air filter that was contaminated by dust particles. Moreover theoretical analysis of antiviral ability with dust contamination and re-coated antiviral agents was carried out using a mathematical model to calculate the time-dependent antiviral effect of the filter under actual conditions of subway station. Our model can be used to apply on antiviral air filtration system of subway station for prevention of pandemic diffusion, and predict the life cycle of an antiviral filter.

섬유여과기와 전기분해조를 병합한 물 재이용 시스템 설계 (Design of a Water Reuse System Combined with a Fiber Filtration and Electrolysis)

  • 신춘환
    • 한국환경과학회지
    • /
    • 제24권11호
    • /
    • pp.1385-1391
    • /
    • 2015
  • A water reuse system was designed for a demonstration plant by combining fiber filtration and electrolysis. A discharged dye wastewater after treated with biomedia was used in this study. It was found that an additional removal of suspended solids (SS) was feasible with 2-stage filtration while electrolysis was not effective. Also, $COD_{cr}$ and $COD_{Mn}$ were not removed with 2 -stage filtration but electrolysis resulted in about 26.9% additional removal. This indicates that electrolysis play an important role in organic removal. Removal of T-N and T-P was negligible with 1 and 2-stage fiber filtration and low-level electrolyte. However, with 2000 ppm of electrolyte, their removal efficiencies were about 83.1 and 60%, respectively, suggesting that the removal rates are well associated with the electrolyte concentrations. With high-level electrolyte, colority was removed about 82% while chlorine ions were removed only about 10%. Therefore, to treat underground water containing high-level salinity in the follow-up study, based on the results in this paper, a combined system with selection of additional unit process and reverse osmosis will be designed.