• Title/Summary/Keyword: filtration efficiency

검색결과 513건 처리시간 0.022초

부상여재 및 모래 여과장치에 의한 조류와 탁도 제거에 관한 연구 (Study on Algae and Turbidity Removal by Floating-media and Sand Filter)

  • 권대영;권재현
    • 상하수도학회지
    • /
    • 제26권5호
    • /
    • pp.659-668
    • /
    • 2012
  • In Korea, almost every water treatment plant suffers from seasonal problem of algae and turbidity which result from eutrophication and heavy rainfall. To relieve this problem, experimental investigation was performed to study the applicability of a floating-media and sand filter to preliminary water treatment in terms of algae and turbidity removal. Experimental results using pure-cultured algae influent showed that the shape of algae species as well as filtration velocity affects the removal efficiency. From the experiments using natural river water, it was concluded that algae removal is more sensitive to floating-media depth but turbidity more sensitive to sand depth. As the filtration velocity increased, the removal of turbidity decreased but that of algae was not affected. The floating-media and sand filter removed more than 30 % of TP, TN, turbidity, Chl-a and CODcr, and less than 20 % of DOC and $UV_{254}$.

해수담수화에서 용존유기물을 제거하기 위한 전처리 공정의 평가 (Evaluation of Pretreatment Processes for Dissolved Organic Carbon Removal in a Desalination Process)

  • 김우항
    • 한국물환경학회지
    • /
    • 제20권5호
    • /
    • pp.447-451
    • /
    • 2004
  • The various pretreatment processes were evaluated to remove organic pollutants of weathered oil contaminated seawater(WOCS) for reverse osmosis desalination process, Biodegradation, coagulation, ultrafiltration, advanced oxidation processes and granular activated carbon filtration were used to evaluate the potential of organic pollutants removal in WOCS. Dissolved Organic Carbon(DOC) was almost not removed by biodegradation in WOCS. DOC was removed by 25% and 10% with the addition of $FeCl_3$ and PAC in WOCS, respectively. The removal efficiency using ultrafiltration(WOCS 500) was about 20% of DOC and 40% of $E_{260}$, respectively. In AOP application of WOCS, the removal of organic materials was improved up to 60% by the combination of $UV/O_3$ compared to UV process. However, 98% of DOC in woes could be removed by granular activated carbon filtration. It is revealed that activated carbon filtration is the best process for the pretratment of DOC removal.

촉매필터를 이용한 먼지 및 HVOC 제거 특성 연구 (Study of Catalytic Filter on the Removal of Dust and HVOC)

  • 정순관;박영옥
    • 공업화학
    • /
    • 제19권1호
    • /
    • pp.80-85
    • /
    • 2008
  • 촉매와 필터가 결합된 촉매필터는 먼지와 가스상 물질을 동시에 제거할 수 있으며 이로 인해 운영비와 설치공간의 감소가 가능한 다기능 반응시스템으로 다양한 환경분야에 적용이 가능하다. 본 연구는 실험실 규모 반응시스템에서 촉매필터를 이용한 먼지와 할로겐 휘발성 유기화합물(halogenated volatile organic compound, 1,2-dichlorobenzene) 제거 연구를 수행하였다. 촉매필터는 저온활성이 우수한 매그린사의 $WO_3-V_2O_5/TiO_2$ 촉매와 $250^{\circ}C$ 이하에서 사용 가능한 P-84를 이용하여 제조하였다. 온도, 면속도, 먼지농도와 같은 다양한 변수조절을 통한 촉매필터의 촉매활성과 먼지제거 효율을 평가하였다. 촉매활성은 온도와 촉매 담지량에 따라 증가하였다. 먼지제거효율은 면속도에 가장 많은 영향을 받는 것으로 나타났다. 시간에 따른 필터의 차압변화 평가 결과 virgin 필터의 경우 탈진간격은 급격한 감소를 보였으며, 잔류압력감소는 거의 변하지 않았다. 촉매필터의 경우 전단에 고착된 나노섬유의 미끄럼 특성에 의하여 차압증가폭이 낮게 나타났다. 촉매필터는 1 m/min, $210^{\circ}C$에서 99.98% 이상의 탈진효율과 90% 이상의 1,2-DCB 제거 효율을 나타냈다.

경남 창녕군 증산리 일대 방사집수정을 활용한 강변 여과수 개발량 평가 (Evaluation of Well Production by a Riverbank Filtration Facility with Radial Collector Well System in Jeungsan-ri, Changnyeong-gun, Korea)

  • 이은희;현윤정;이강근;김형수;정재훈
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권4호
    • /
    • pp.1-12
    • /
    • 2010
  • Well production by a riverbank filtration facility with multi-radial collector well systems in Jeungsan-ri, Changnyeong gun, Korea was evaluated. In this study, the drawdown at collector wells due to pumping and groundwater inflow rates along the horizontal arms of the collector wells were computed through numerical simulations. Sensitivities of the well production to hydraulic conductivity and well flow coefficient, which represents the resistance to the flow from the aquifer to the horizontal arms, were analyzed. Simulation results showed that, with given proposed pumping rate conditions, the drawdown in the caisson exceeded maximum drawdown constraints in the study site and the adjustment of the pumping rate at each well is needed. The drawdown is affected by the hydraulic conductivity of the main aquifer and the well flow coefficient, which means the profound field investigation of the study site is needed to accurately estimate the efficiency of riverbank filtration through radial collector wells.

정수처리에서 제올라이트 여과를 이용한 암모니아성질소의 제거와 재생 (Ammonium Ion Removal and Regeneration for Zeolite Filtration in Drinking Water Treatment)

  • 김우향;이승희
    • 한국환경과학회지
    • /
    • 제13권7호
    • /
    • pp.661-665
    • /
    • 2004
  • As the concentration of ammonium nitrogen could be reached 2~3 mg/L in the winter in the river. It was clear that the excessive concentration of chlorinated organics could be produced with the increase of chlorine addition to remove ammonium nitrogen. In the innovative ammonium nitrogen removal process, zeolite adsorption is very efficient as substitute for rapid sand filtration without other adverse quality change in the water. This study is conducted to evaluate the feasibility of ammonium nitrogen removal and regeneration by zeolite adsorption in drinking water treatment. Also, the reuse possibility of zeolite is evaluated to change the removal efficiency of ammonium nitrogen through several times of regeneration. The ammonium nitrogen was not removed in sand filter, but it was almost removed in zeolite filter during 7 days. The sand and zeolite filters have a similar result of turbidity removal. Therefore, zeolite filtration was confirmed the removal of turbidity and ammonium nitrogen as a media. When compared KCl with NaCl as a chemical for zeolite regeneration, it is demonstrated that KCl was more efficient than NaCl in the ability of zeolite regeneration. The adsorption rate of ammonium nitrogen was almost not decreased in the results of several times of regeneration. It is indicated that both zeolite and regeneration solution were possible to reuse without variation of regeneration rate through this study.

합성섬유 여재를 충진한 고속여과장치에 의한 탁수처리에 관한 연구 (Treatment Study of the Turbid Water by High-Speed Synthetic Fiber Filter System)

  • 박기수;청징;김영철
    • 한국물환경학회지
    • /
    • 제31권3호
    • /
    • pp.262-271
    • /
    • 2015
  • Laboratory study was undertaken to pursue the filter performance of a micro-filter module employing highly porous fiber media under a high filtration rate (over 1,500 m/day), faster than that of any conventional filter process. The effects of filtration rate, head loss, raw water turbidity, and filter aid chemicals on filter performance were analyzed. In spite of the extremely high filtration rate, the filter achieved an attractive efficiency, reducing the raw water turbidity by over 80%. As with other filter systems, the filter aid used (PAC in this study) greatly affected the performance of this particular fiber filter. Long term repetitive runs were additionally carried out to confirm the reproducibility of the filter performance. Finally, a comparison was carried out with other high rate filter systems which are either being tested for use in experimental studies, or are already commercially available.

실내공기질 모델을 이용한 환기 시스템의 공기 정화 효율성 평가 (Evaluation of Ventilation System Performance Using Indoor Air Quality Model)

  • 최성우
    • 한국환경보건학회지
    • /
    • 제23권4호
    • /
    • pp.57-66
    • /
    • 1997
  • Successful energy conservation and good indcfor air quality (IAQ) are highly dependent on ventilation system. Air filtration is a primary solution of indoor air control strategies in terms of reducing energy consumption and improving ihdoor air quality. A conventional system with bypass filter, as it is called variable-air-volume/bypass filtration system (VAV/BPFS), is a variation of the conventional variable air volume (VAV) systems, which is designed to eliminate indoor air pollutant and to save energy. Bypass filtration system equipped with a high-efficiency particulate filter and carbon absorbent provides additional cleaned air into indoor environments and maintain good IAQ for human health. The objectives of this research were to compare the relative total decay rate of indoor air pollutant concentrations, and to develop a mathematical model simulating the performance of VAV/BPFS. All experiments were performed in chamber under the controlled conditions. The specific conclusions of this research are: 1. The VAV/BPFS system is more efficient than the VAV system in removing indoor air pollutant concentration. The total decay rates of aerosol, and total volatile organic compound (TVOC) for the VAV/BPFS system were higher than those of the conventional VAV system. 2. IAQ model predictions of each pollutant agree closely with the measured values. 3. According to IAQ model evaluation, reduction of outdoor supply air results in decreased dilution removal rate and on increased bypass filtration removal rate with the VAV/BPFS. As a results, we recommends the VAV/BPFS as an alternative to conventional VAV systems.

  • PDF

침지형 막결합 연속회분식 반응기의 운전에서 폐수의 도입단계가 제거효율과 여과성능에 미치는 영향 (The Effect of Filling Step on the Removal Efficiency and Filtration Performance in the Operation of Submerged Membrane-Coupled Sequencing Batch Reactor)

  • 김승건;이호원;강영주
    • 멤브레인
    • /
    • 제21권3호
    • /
    • pp.263-269
    • /
    • 2011
  • 침지식 막결합형 연속회분식 생물반응기에서 폐수의 도입단계가 제거효율과 여과성능에 미치는 영향을 조사하였다. 호기성 단계의 초기에 공급할 경우(Mode-1)와 무산소 단계의 초기에 공급할 경우(Mode-2)에 대하여 89일 동안 동시에 운전하였다. COD 제거효율과 여과성능은 2가지 운전방식 간에 큰 차이가 없었다. 그러나 영양염류(총질소와 총인)의 제거효율에 있어서 Mode-2가 Mode-1에 비해 보다 효과적이었다. Mode-2의 경우 COD, 총질소 및 총인의 제거율은 각각 99.1, 73.3 및 77.7%이었다.

Chemical mechanical planarization 슬러리에 사용되는 point-of-use 필터의 평가 방법 개발 (Development of point-of-use filter evaluation method using chemical mechanical planarization slurry)

  • 장선재;아툴 쿨르카르니;김형우;김태성
    • 한국입자에어로졸학회지
    • /
    • 제12권4호
    • /
    • pp.145-150
    • /
    • 2016
  • During the chemical mechanical planarization (CMP) process, slurry that comprises abrasive particles can directly affect the CMP performance and quality. Mainly, the large particles in the slurry can generate the defects on the wafer. Thus, many kinds of filters have been used in the CMP process to remove unwanted over-sized particles. Among these filters, the point-of-use (POU) filter is used just before the slurry is supplied onto the CMP pad. In the CMP research field, analysis of the POU filter has been relatively exceptional, and previous studies have not focused on the standardized filtration efficiency (FE) or filter performance. Furthermore, conventional evaluation methods of filter performance are not appropriate for POU filters, as the POU filter is not a membrane type, but is instead a depth type roll filter. In order to accurately evaluate the POU filter, slurry FE according to particle size was measured in this study. Additionally, a CMP experiment was conducted with filtered slurry to demonstrate the effects of filtered slurry on CMP performance. Depending on the flow rate and the filter retention size, the FE according to particle size was different. When the small and large particles have different FEs, the total filtration efficiency (TFE) can still have a similar value. For this reason, there is a need to measure the FE with respect to the particle size to verify the effects of the POU filter on the CMP process.

고밀도 폴리에틸렌 플렉시 필라멘트로 제조된 습식부직포의 에어필터 여재 특성 연구 (Air-Filter Media Characteristics of Wet-laid Nonwoven based on HDPE Plexi-filament)

  • 배영환;위재형;이명성;양병진;김도군;여상영
    • 한국염색가공학회지
    • /
    • 제33권4호
    • /
    • pp.302-308
    • /
    • 2021
  • Air filters are being used in countless places from industrial sites to everyday life. The spread of the COVID-19 virus, which started in 2019, is disrupting people's daily lives, and the importance of air filters as a basic means to prevent the spread of these diseases is further highlighted. In this study, the purpose was to develop another type of air filter media with excellent barrier properties that can replace PP meltblown nonwoven fabrics widely used commercially due to its excellent electrostatic properties, differential pressure and filtration efficiency. Therefore, wet-laid nonwoven for air filters were manufactured using plexi-filaments formed through flash spinning and having various fiber diameter from hundreds of nanometers to tens of micrometers, and its applicability as an air-filter media was investigated compared to the meltblown nonwoven. As a result of the performance evaluation, it was found that the filtration efficiency and barrier performance at 0.3㎛ was superior to that of the meltblown nonwoven of the same weight, although the differential pressure was high due to morphological properties of the plexi-filament.