• Title/Summary/Keyword: filter sub-system

Search Result 207, Processing Time 0.032 seconds

A Study on the Bandwidth Efficiency of MC-CDMA System (MC-CDMA 시스템에서 주파수 대역 효율에 관한 연구)

  • Jee, Innho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.43-48
    • /
    • 2021
  • We propose 2-channel filter bank method instead of FFT method to decrease sub-channel interference for using of efficient frequency resource in MC-CDMA method. Since a prototype filter of filter bank having wavelet characteristic is designed having more less side-lobe, the nearest co-channel interference and inter symbol interference are decreased efficiently. Since the spreading signal of suggesting MC-CDMA system is being demanded for less chip rate and is not being considering for autocorrelation characteristic, the Walsh code can be used as a optimal orthogonal signal set. We consider bit error rate and signal to noise ratio to estimate the performance of suggested system on condition that white noise channel and arbitrary sinusoidal jammer are existing. As a result of comparing to traditional FFT-based MC-CDMA simulation result, our suggested system has shown better performance than traditional MC-CDMA method on the side of minimizing interference effect.

Prediction of the Efficiency of Factors Affecting Pressure Drop in a Pulse Air Jet-type Bag Filter (충격기류식 여과집진장치에서 압력손실에 영향을 주는 인자의 효율예측)

  • Suh, Jeong-Min;Ryu, Jae-Yong;Lim, Woo-Taik;Jung, Moon-Sub;Park, Jeong-Ho;Shin, Choon-Hwan
    • Journal of Environmental Science International
    • /
    • v.19 no.4
    • /
    • pp.437-446
    • /
    • 2010
  • The pressure drop through pulse air jet-type bag filter is one of the most important factors on the operating cost of bagfilter houses. In this study, the pilot-scale pulse air jet-type bag filter with about 6 m2 filtration area was designed and tested for investigating the effects of the four operating conditions on the total pressure drop, using the coke dust collected from a steel mill factory. When the face velocity is higher than 2 m/min, it is not applicable to on-spot due to the increase of power expenses resulting from a high-pressure drop, and thus, 1.5 m/min is considered to be reasonable. The regression analysis results show that the degree of effects of independent parameters is a order of face velocity > concentration > time > pressure. The results of SPSS answer tree analysis also reveal that the operation time affects the pressure drop greatly in case of 1 m/min of face velocity, while the inlet concentration affects the pressure drop in case of face velocity more than 1.5 m/min.

Comparative Analysis of SOC Estimation using EECM and NST in Rechargeable LiCoO2/LiFePO4/LiNiMnCoO2 Cells

  • Lee, Hyun-jun;Park, Joung-hu;Kim, Jonghoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1664-1673
    • /
    • 2016
  • Lithium rechargeable cells are used in many industrial applications, because they have high energy density and high power density. For an effective use of these lithium cells, it is essential to build a reliable battery management system (BMS). Therefore, the state of charge (SOC) estimation is one of the most important techniques used in the BMS. An appropriate modeling of the battery characteristics and an accurate algorithm to correct the modeling errors in accordance with the simplified model are required for practical SOC estimation. In order to implement these issues, this approach presents the comparative analysis of the SOC estimation performance using equivalent electrical circuit modeling (EECM) and noise suppression technique (NST) in three representative $LiCoO_2/LiFePO_4/LiNiMnCoO_2$ cells extensively applied in electric vehicles (EVs), hybrid electric vehicles (HEVs) and energy storage system (ESS) applications. Depending on the difference between some EECMs according to the number of RC-ladders and NST, the SOC estimation performances based on the extended Kalman filter (EKF) algorithm are compared. Additionally, in order to increase the accuracy of the EECM of the $LiFePO_4$ cell, a minor loop trajectory for proper OCV parameterization is applied to the SOC estimation for the comparison of the performances among the compared to SOC estimation performance.

Optimization of target, moderator, and collimator in the accelerator-based boron neutron capture therapy system: A Monte Carlo study

  • Cheon, Bo-Wi;Yoo, Dohyeon;Park, Hyojun;Lee, Hyun Cheol;Shin, Wook-Geun;Choi, Hyun Joon;Hong, Bong Hwan;Chung, Heejun;Min, Chul Hee
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1970-1978
    • /
    • 2021
  • The aim of this study was to optimize the target, moderator, and collimator (TMC) in a neutron beam generator for the accelerator-based BNCT (A-BNCT) system. The optimization employed the Monte Carlo Neutron and Photon (MCNP) simulation. The optimal geometry for the target was decided as the one with the highest neutron flux among nominates, which were called as angled, rib, and tube in this study. The moderator was optimized in terms of consisting material to produce appropriate neutron energy distribution for the treatment. The optimization of the collimator, which wrapped around the target, was carried out by deciding the material to effectively prevent the leakage radiations. As results, characteristic of the neutron beam from the optimized TMC was compared to the recommendation by the International Atomic Energy Agent (IAEA). The tube type target showed the highest neutron flux among nominates. The optimal material for the moderator and collimator were combination of Fluental (Al203+AlF3) with 60Ni filter and lead, respectively. The optimized TMC satisfied the IAEA recommendations such as the minimum production rate of epithermal neutrons from thermal neutrons: that was 2.5 times higher. The results can be used as source terms for shielding designs of treatment rooms.

Introducing SPARTAN Instrument System for PM Analysis (PM 관측을 위한 스파르탄 시스템)

  • Sujin Eom;Sang Seo Park;Jhoon Kim;Seoyoung Lee;Yeseul Cho;Seungjae Lee;Ehsan Parsa Javid
    • Atmosphere
    • /
    • v.33 no.3
    • /
    • pp.319-330
    • /
    • 2023
  • As the need for PM type observation increases, Surface Particulate Matter Network (SPARTAN), PM samplers analyzes aerosol samples for PM mass concentration and chemical composition, were recently installed at two sites: Yonsei University at Seoul and Ulsan Institute of Science and Technology (UNIST) at Ulsan. These SPARTAN filter samplers and nephelometers provide the PM2.5 mass concentration and chemical speciation data with aerosol type information. We introduced the overall information and installation of SPARTAN at the field site in this study. After installation and observation, both Seoul and Ulsan sites showed a similar time series pattern with the daily PM2.5 mass concentration of SPARTAN and the data of Airkorea. In particular, in the case of high concentrations of fine particles, daily average value of PM2.5 was relatively well-matched. During the Yonsei University observation period, high concentrations were displayed in the order of sulfate, black carbon (BC), ammonium, and calcium ions on most measurement days. The case in which the concentration of nitrate ions showed significant value was confirmed as the period during which the fine dust alert was issued. From the data analysis, SPARTAN data can be analyzed in conjunction with the existing urban monitoring network, and it is expected to have a synergetic effect in the research field. Additionally, the possibility of being analyzed with optical data such as AERONET is presented. In addition, the method of installing and operating SPARTAN has been described in detail, which is expected to help set the stage for the observation system in the future.

EFFECT OF GRASS FILTER STRIPS ON REDUCING $PO_4$-P LOSS IN RUNOFF FROM FORAGE CROPLAND

  • Jung, M.W.;Jo, N.C.;Yoon, S.H.;Kim, W.H.;Kim, K.Y.;Sung, S.
    • Korean Journal of Organic Agriculture
    • /
    • v.19 no.spc
    • /
    • pp.169-173
    • /
    • 2011
  • The performance of grass filter strips (GFS) in abating $PO_4$-P concentrations from the forage cropland was tested in an experiment on the 10% slope in Grassland and Forages Division, National Institute of Animal Science, Rural Development Administration (RDA) from October 2007 to September 2009. Forage croplands with rye-corn double cropping system applied with chemical fertilizer and livestock manure (LM) were compared in a natural condition. The plots were hydrologically isolated Main plots consisted of the length of GFS, such as 0m, 5m, 10m and 15m. Sub plots consisted of the type of LM, such as chemical fertilizer (CF), composted cattle manure (CCM) and composted swine manure (CSM). Concentrations of PO4-P in surface runoff water were reduced as the length of GFS increased. Especially, GFS with 10m and 15m reduced $PO_4$-P concentrations significantly compared to that with 0m and 5m (p<0.05). The results from this study suggest that GFS improved the removal and trapping $PO_4$-P from forage croplands.

Design and characterization of conductive transparent filter using [TiO2|Ti|Ag|TiO2] multilayer ([TiO2|Ti|Ag|TiO2] 다층구조를 이용한 전도성 투과필터의 설계 및 특성분석)

  • Lee, Seung-Hyu;Lee, Jang-Hoon;Hwangbo, Chang-Kwon
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.4
    • /
    • pp.363-369
    • /
    • 2002
  • We have designed conductive transparent filters using a low-emissivity coating such as [dielectric|Ag|dielectric] for display applications. The design is the repetition of [$TiO_{2}$|Ti|Ag |$TiO_{2}$] to increase the transmittance in the visible and decrease the transmittance in the near IR. The conductive transparent filters are deposited by a radio frequency(RF) magnetron sputtering system. The optical, structural and electrical properties of the filters were investigated and the optical spectra are compared with simulated spectra. The thickness of the deposited Ag films is above 13 ㎚ to increase the conductivity and that of $TiO_{2}$ films is 24 ㎚ to increase the transmittance in the visible range. Ti blockers are employed to prevent the Ag films from being oxidized by an oxygen gas during the reactive sputtering process. Also, it is shown that the thicker Ti film is necessary as the period increases. Finally, a filter with repetition of the basic structure three times shows the better cut-off near infrared(NIR) and the sheet resistance as low as 2Ω/□ which is enough to shield an unnecessary electromagnetic waves for a display panel.

Concentrations of Particulate Matter Exposed to Farm Workers in the Broiler Houses (육계사 내 작업자의 미세먼지 노출량 현장모니터링)

  • Seo, Hyo-Jae;Oh, Byung-Wook;Kim, Hyo-Cher;Sin, So-Jung;Seo, Il-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.5
    • /
    • pp.27-37
    • /
    • 2020
  • As domestic meat consumption increases, the broiler production industry has been larger and denser. The concentration of particulate matter (PM) and harmful gases generated is also increasing inside livestock house. However, the current research status of PM exposed to farm workers and the health effects are in the early stage. To understand PM concentration affecting workers in the broiler house, field monitoring was conducted according to its size distributions. Concentrations of PM10, PM2.5, and TD (Total Dust) were monitored using personal air samplers with teflon filter during working and moving periods considering the ventilation systems of 6 broiler houses. The purpose of this study is to monitor the PM concentration in the experimental broiler houses operated by forced ventilation system generally used in Korea and to evaluate the regional concentrations through airflow pattern. The PM concentrations were increased from inlet to outlet vents resulting in 1,872 of TD, 1,385 of PM10, and 209 ㎍/㎥ of PM2.5, respectively. The TD and PM10 concentrations were increased when the workers and broilers were moving. Among them, the particle size that occupied the largest amount of PM was 13.75 ㎛. These results suggest that personal protection equipments are important to reduce the health effect from PM inhalation.

Radon Removal Efficiency of Activated Carbon Filter from Coconut (코코넛 기반 활성탄 필터의 라돈 제거 효율)

  • Yun-Jin Ahn;Gi-Sub Kim;Tae-Hwan Kim;Sang-Rok Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.141-149
    • /
    • 2023
  • The Korea Institute of Radiological and Medical Sciences plans to produce 225Ac, a therapeutic radio-pharmaceutical for precision oncology, such as prostate cancer. Radon, a radioactive gas, is generated by radium, the target material for producing 225Ac. The radon concentration is expected to be about 2000 Bq·m-3. High-concentration radon-generating facilities must meet radioactive isotope emission standards by lowering the radon concentration. However, most existing studies concerning radon removal using activated carbon filters measured radon levels at concentrations lower than 1000 Bq·m-3. This study measured 222Rn removal of coconut-based activated carbon filter under a high radon concentration of about 2000 Bq·m-3. The 222Rn removal efficiency of activated carbon impregnated with triethylenediamine was also measured. As a result, the 222Rn removal amount of the activated carbon filter showed sufficient removal efficiency in a 222Rn concentration environment of about 2000 Bq·m-3. In addition, despite an expectation of low radon reduction efficiency of Triethylenediamine-impregnated activated carbon, it was difficult to confirm a significant difference in the results. Therefore, it is considered that activated carbon can be used as a radioisotope exhaust filter regardless of whether or not Triethylenediamine is impregnated. The results of this study are expected to be used as primary data when building an air purification system for radiation safety management in facilities with radon concentrations of about 2000 Bq·m-3.

Bidirectional LLC-LC Resonant Converter With Notch Filter (노치 필터 적용 양방향 LLC-LC 공진컨버터)

  • Jang, Ki-Chan;Kim, Eun-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.6
    • /
    • pp.411-420
    • /
    • 2021
  • In this paper, bidirectional LLC-LC resonant DC-DC converter with notch filters in the primary side of resonant circuits is proposed. Even if resonant capacitors are used on the primary and secondary sides, the proposed converter can operate with the high gain characteristics of the LLC resonant converter without mutual coupling of resonant capacitors, regardless of the direction of power flow. In addition, by applying notch filters, the proposed converter can operate with a wider gain control range and can cope with overload and short circuit. The analysis and operating characteristics of the proposed bidirectional LLC-LC resonant converter are investigated. A 3.3 kW prototyped bidirectional LLC-LC resonant converter connected to 750 VDC buses is designed and tested to verify the validity and applicability of this proposed converter.