• Title/Summary/Keyword: film vessel

Search Result 53, Processing Time 0.025 seconds

A Measurement Method of Internal Defects of Pressure Vessles by Using Real-Time Holographic Interferometry (실시간 홀로그래픽 간섭법을 이용한 압력용기의 내부결함 측정법)

  • Moon, Sang-Joon;Kang, Young-June;Baik, Sung-Hoon;Kim, Cheol-Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1233-1240
    • /
    • 1996
  • Conventional measurement methods using ultrasonic wave or x-ray, eddy current for non-destructive testing(NDT) in nuclear power plants and other industrial plants have been utilized as the method of contact with objects to be inspected. For this reason these methods require relatively much time and inspection area is limited by the location of probe or film. But holograpic interferometry which is a non-contact optical measurement method using a coherent light source has an advantage that quantative measurement can be performed at a time. In this paper a new method using realtime holographic interfreometry and image processing for detecting internal flaws of pressure vessels is presented.

Development of Automatic Recognition and Spray Control System for Reducing the Amount of Marine Coating paint (선박용 피도물 도료 사용량 절감을 위한 인식 및 스프레이 자동제어시스템 개발)

  • Jung, Young-Deuk
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.3
    • /
    • pp.23-27
    • /
    • 2019
  • The first aim of the study is to improve the productivity by uniformizing the thickness of coating and reducing quality-inspection time. The second aim is to cut down on the raw materials for coating by prevent the waste of spraying in the air during a painting process through a real-time coating-size-recognition monitering to fit the target components. To achieve the two aims, a simplified version of automatic coating control system for recognition of coating for vessels and Spray. With the sytem, following effects are expected: First, quality improvement will be achieved by uniformizing the film-thickness. Second, it will reduce the waste of coating paint by constructing the speed of the coating, the spray gun robot transfer time, and the number of DBs according to the size of the vessel. Third, as a 3D industry, it will be able to solve the difficulty of supply of labors and save up the labor costs. Therefore, in the future, further research will be needed to be applied to various products with DB design that designates the variable value, which is added for each type of pieces by comparing the difference between various types of workpieces and linear ones.

Morphology of Methane/Propane Clathrate Hydrate Crystal (메탄/프로판 포접 하이드레이트 결정의 성장 특성)

  • Lee, Ju Dong;Englezos, Peter;Yoon, Yong Seok;Song, Myungho
    • Korean Chemical Engineering Research
    • /
    • v.45 no.4
    • /
    • pp.400-409
    • /
    • 2007
  • Morphology of methane/propane clathrate hydrate crystal was investigated under different undercooling conditions. After the water pressurized with compound guest gas was fully saturated by agitation, medium within the vessel was rapidly undercooled and maintained at the constant temperature while the visual observations using microscope revealed detailed features of subsequent crystal nucleation, migration, growth and interference occurring within liquid pool. The growth of hydrate was always initiated with film formations at the bounding surface between bulk gas and liquid regions under all tested experimental conditions. Then a number of small crystals ascended, some of which settled beneath the hydrate film. When undercooling was relatively small, some of the settled crystals slowly grew into faceted columns. As the undercooling increased, the downward growth of crystals underneath the hydrate film became dendritic and occurred with greater rate and with finer arm spacing. The shapes of the floating crystals within liquid pool were diverse and included octahedron and triangular or hexagonal platelet. When the undercooling was small, the octahedral crystals were found dominant. As the undercooling increased, the shape of the floating crystals also became dendritic. The detailed growth characteristics of floating crystals are reported focused on the influences caused by undercooling and memory effect.

Fabrication and validation study of a 3D tumor cell culture system equipped with bloodvessle-mimik micro-channel (혈관모사 마이크로채널이 장착된 3D 종양 세포 배양 시스템의 제작 및 검증 연구)

  • Park, Jeong-Yeon;Koh, Byum-seok;Kim, Ki-Young;Lee, Dong-Mok;Yoon, Gil-Sang
    • Design & Manufacturing
    • /
    • v.15 no.2
    • /
    • pp.11-16
    • /
    • 2021
  • Recently, three-dimensional (3D) cell culture systems, which are superior to conventional two-dimensional (2D) vascular systems that mimic the in vivo environment, are being actively studied to reproduce drug responses and cell differentiation in organisms. Conventional two-dimensional cell culture methods (scaffold-based and non-scaffold-based) have a limited cell growth rate because the culture cannot supply the culture medium as consistently as microvessels. To solve this problem, we would like to propose a 3D culture system with an environment similar to living cells by continuously supplying the culture medium to the bottom of the 3D cell support. The 3D culture system is a structure in which microvascular structures are combined under a scaffold (agar, collagen, etc.) where cells can settle and grow. First, we have manufactured molds for the formation of four types of microvessel-mimicking chips: width / height ①100 ㎛ / 100 ㎛, ②100 ㎛ / 50 ㎛, ③ 150 ㎛ / 100 ㎛, and ④ 200 ㎛ / 100 ㎛. By injection molding, four types of microfluidic chips were made with GPPS (general purpose polystyrene), and a 100㎛-thick PDMS (polydimethylsiloxane) film was attached to the top of each microfluidic chip. As a result of observing the flow of the culture medium in the microchannel, it was confirmed that when the aspect ratio (height/width) of the microchannel is 1.5 or more, the fluid flows from the inlet to the outlet without a backflow phenomenon. In addition, the culture efficiency experiments of colorectal cancer cells (SW490) were performed in a 3D culture system in which PDMS films with different pore diameters (1/25/45 ㎛) were combined on a microfluidic chip. As a result, it was found that the cell growth rate increased up to 1.3 times and the cell death rate decreased by 71% as a result of the 3D culture system having a hole membrane with a diameter of 10 ㎛ or more compared to the conventional commercial. Based on the results of this study, it is possible to expand and build various 3D cell culture systems that can maximize cell culture efficiency by cell type by adjusting the shape of the microchannel, the size of the film hole, and the flow rate of the inlet.

Evaluation of Applicability of Heavy Oil Upgrading By-Product (Pitch) as A Pavement Paving Material (중질유 고도정제 부산물의 도로포장용 역청재료로서의 적용성 평가)

  • Yang, Sung Lin
    • International Journal of Highway Engineering
    • /
    • v.16 no.5
    • /
    • pp.9-18
    • /
    • 2014
  • PURPOSES : The objective of this study is to evaluate the applicability of the pitch, which is produced during SDA petroleum upgrading process, as a pavement paving material. In order for the purpose, the physical and chemical properties of the pitch are analyzed, and then the various plasticizers are applied in the pitch. METHODS : Two types of pitch are selected from oil refinery companies, which are owned the SDA petroleum upgrading process. Also, two types of asphalt binders, PG 64-22 and PG 58-22, are employed to compare with the pitch because these two types of asphalt binders are currently used as paving materials. For the chemical property of the pitch, the composition of SARA (Saturate, Aromatic, Resin, Asphaltene), the elementary composition, and the functional group are analyzed. For the physical property of the pitch, the basic material property tests, such as penetration test, softening point test, flash point test, ductility test, and rotational viscometer test, are performed. Also, the DSR (Dynamic Shear Rheometer) test and the BBR (Bending Beam Rheometer) test are conducted using asphalt binder specimens obtained by both short term aging (Rolling Thin Film Oven, RTFO) and long term aging (Pressure Aging Vessel, PAV) processes. The rheological property of each pitch type is evaluated as a function of temperatures and loading cycles. PG 64-22 asphalt binder is used as a control material. RESULTS AND CONCLUSIONS : The Pitch may not be suitable for the pavement paving material without modifications, but the pitch can be used as alternatives of modified addictive or asphalt. If low molecular component, such as saturate and aromatic components, are added in the pitch based on the development of various plasticizers, it has a strong possibility for the pitch to be used as a alternative. However, in order to verify the performance property of the pitch, further research is needed.

Effect of spinning parameters of polyethersulfone based hollow fiber membranes on morphological and mechanical properties

  • Tewfik, Shadia R.;Sorour, Mohamed H.;Shaalan, Hayam F.;Hani, Heba A.
    • Membrane and Water Treatment
    • /
    • v.9 no.1
    • /
    • pp.43-51
    • /
    • 2018
  • Hollow fiber (HF) membranes are gaining wide interest over flat membranes due to their compaction and high area to surface volume ratio. This work addresses the fabrication of HF from polysulfone (PS) and polyethersulfone (PES) using N-methylpyrrolidone (NMP) as solvent in addition to other additives to achieve desired characteristics. The semi-pilot spinning system includes jacketed vessel, four spinneret block, coagulation and washing baths in addition to dryer and winder. Different parameters affecting dry-wet spinning phase inversion process were investigated. Dope compositions of PES, NMP and polyvinyl pyrrolidone (PVP) of varying molecular weights as additive were addressed. Some critical parameters of importance were also investigated. Those include dope flow rate, air gap, coagulation & washing baths and drying temperatures. The measured dope viscosity was in the range from 1.7 to 36.5 Pa.s. Air gap distance was adjusted from 20 to 45 cm and coagulation bath temperature from 20 to $46^{\circ}C$. The HF membranes were characterized by scanning electron microscope (SEM), atomic force microscope (AFM) and mechanical properties. Results indicated prevalence of finger like structure and average surface roughness from about 29 to 78.3 nm. Profile of stress strain characteristics revealed suitability of the fibers for downstream interventions for fabrication of thin film composite membrane. Different empirical correlations were formulated which enable deeper understanding of the interaction of the above mentioned variables. Data of pure water permeability (PWP) confirmed that the fabricated samples fall within the microfiltration (MF)-ultrafiltration (UF) range of membrane separation.

Laboratory Performance Evaluation of Recycled Asphalt Binders with Differing Rejuvenators (재생 첨가제를 활용한 재활용 아스팔트 바인더의 실내 공용성 평가)

  • Kim, Yeong Min;Im, Jeong Hyuk;Hwang, Sung Do;Jeong, Kyu Dong;Rhee, Suk Keun
    • International Journal of Highway Engineering
    • /
    • v.17 no.6
    • /
    • pp.55-63
    • /
    • 2015
  • PURPOSES : The objective of this study is to investigate the properties of recycled asphalt binders with five different rejuvenators, in order to evaluate the applicability of the recycled asphalt binders compared with the original asphalt binder. METHODS : In order to simulate recycled asphalt binders, fresh asphalt binders are aged by various Superpave aging procedures, such as the rolling thin-film oven (RTFO) and the pressure aging vessel (PAV). Then, selected rejuvenators are added to the aged asphalt binders in the amount of 5%, 10%, and 15%. The asphalt binder properties are evaluated by the dynamic shear rheometer (DSR), the rotational viscometer (RV), and the bending beam rheometer (BBR). In this study, AP-5 (penetration grade 60-80, PG 64-16) asphalt binder is used. A total of five types of rejuvenators are employed. RESULTS AND CONCLUSIONS : When considering aged asphalt without a new asphalt binder, it seems that the percentage of rejuvenator used in Korea is a bit too low, and that it fails to possess the characteristics of the original binder. From the current practice of evaluating the properties of recycled binder based on penetration ratio only, the amount of rejuvenator required is similar for the long-term-aged binder, but is excessive for the longest-term aged binder, causing deterioration of workability and stiffness of the recycled binder.

Comparison of TOFD and Radiographic Testing for a Mock-up Specimen (모의 시험편에 대한 TOFD와 방사선투과시험의 비교)

  • Kim, Chung-Jick;Jeon, Jong-Gun;Kim, Jin-Taek
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.1
    • /
    • pp.64-69
    • /
    • 2008
  • In order to detect the internal defects which occur in welding parts of pressure vessel and structures, radiographic testing and ultrasonic testing is applied. However, because of the risks of radiation exposure and film processing, radiographic testing takes a relatively long time to verify the test results and it has affected in the production process. Typically, the manual ultrasonic testing is not easy to reproduce the result and it is highly dependent on the tester's skills. The TOFD technique, one of the automatic ultrasonic testings is spreading alternatively. This research describes the comparing test results by applying radiographic testing and TOFD technique to a mock-up specimen incruding the flaws. The TOFD technique will contribute to improve the objective reliability of the ultrasonic technique.

Usefuless of Multi-functional Gastroduodenal Coil Catheter with Phantom (팬텀을 이용한 다기능 위.십이지장관 코일 카테타의 유용성 평가)

  • Lim, Jin-Oh;Kim, Tae-Hyung;Jung, Yang-Hwa;Choi, Won-Chan;Shin, Ji-Hoon;Song, Ho-Young
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.21-26
    • /
    • 2003
  • To evaluate the newly designed gastroduodenal coil catheter:in-vitro test. The coil catheter that we made in our laboratory was 150 cm. The coil that is made of stainless steel wire was composed 1.3 mm inner diameter and this coil spring was covered with heat-shrinkable polyethylene tube. To measure the length under fluorocopy, 8 radiopaque marks were attached at 5 cm, 10 cm, 11 cm, 12 cm, 13 cm, 14 cm, 15 cm, 20 cm apart from distal end of the catheter and 6, 2, 1 pores were made at 7 cm, 13 cm, 19 cm apart from the distal end. Radio-opacity and the amount of injected contrast was investigated in formerly used 5 Fr. vessel catheter, which is possible in measuring length, and newly designed coil catheter. Film density was tested for radio-opacity with autodensitometer. For measuring the volume of injected salin, the catheter was located in the acryl box(26 cm, 3 cm, 16 cm) that divided into 4 chambers. After injection 50 cc of contrast with autoinjector, the contrast's quantity in each chamber was measured with and without over the guide wire. Radio-opacity was 0.51 in 5 Fr. vessel catheter, 0.31 in newly made catheter. The amount of injected contrast was measured. In case of 5 Fr. vessel catheter, the amount was 99.5% from the distal part, there was no difference between with and without the guide wire. Otherwise, using a coil catheter, the pacentage the ejected saline was 1.17%, 18.8%, 41.8%, 38.2% from the distal part with the guide wire, 19.5%, 32.6%, 27.7%, 20.3% without the guide wire. Compare with formerly established catheter, this new coil catheter is easy to measure the length thanks to easy confirming under fluoroscopy and excellent in injecting contrast. Therefore, newly designed gastrointestinal catheter seems to be useful in gastrointestinal intervention procedure.

  • PDF

Effect of Transient Condition on Propeller Shaft Movement during Starboard Turning under Ballast Draught Condition for the 50,000 DWT Oil Tanker (50,000 DWT 유조선의 밸러스트 흘수에서 우현 전타시 과도상태가 프로펠러축 거동에 미치는 영향 연구)

  • Lee, Jae-ung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.4
    • /
    • pp.412-418
    • /
    • 2020
  • Generally, the propeller shaft that constitutes the ship shaft system has different patterns of behavior due to the ef ects of engine power, propeller load and eccentric thrust, which increases the risk of bearing failure by causing local load variations. To prevent this, different studies of the propulsion shaft system have been conducted focused the relative inclination angle and oil film retention between the shaft and the support bearing, mainly with respect to the Rules for the Classification of Steel Ships. However, in order to secure the stability of the propulsion shaft via a more detailed evaluation, it is necessary to consider dynamic conditions, including the transient state due to sudden change in the stern wakefield. In this context, a 50,000 DWT vessel was analyzed using the strain gauge method, and the effects of propeller shaft movement were analyzed on the starboard rudder turn which is a typical transient state during normal continuous rate(NCR) operation in ballast draught condition. Analysis results confirm that the changed propeller eccentric thrust acts as a force that temporarily pushes down the shaft to increase the local load of the stern tube bearing and negatively affects the stability of the shaft system.