Comparison of TOFD and Radiographic Testing for a Mock-up Specimen

모의 시험편에 대한 TOFD와 방사선투과시험의 비교

  • Published : 2008.02.28

Abstract

In order to detect the internal defects which occur in welding parts of pressure vessel and structures, radiographic testing and ultrasonic testing is applied. However, because of the risks of radiation exposure and film processing, radiographic testing takes a relatively long time to verify the test results and it has affected in the production process. Typically, the manual ultrasonic testing is not easy to reproduce the result and it is highly dependent on the tester's skills. The TOFD technique, one of the automatic ultrasonic testings is spreading alternatively. This research describes the comparing test results by applying radiographic testing and TOFD technique to a mock-up specimen incruding the flaws. The TOFD technique will contribute to improve the objective reliability of the ultrasonic technique.

압력용기 및 구조물 용접부의 내부결함을 검출하기 위해서는 방사선투과시험과 초음파탐상시험을 시행한다. 그러나 방사선투과시험은 방사선 노출 위험성과 필름 현상처리 소요 등으로 결과의 확인에 상대적으로 긴 시간이 소요되어 제작 공정에 영향을 준다. 일반적인 수동 초음파탐상시험은 결과의 재현이 용이하지 않으며 검사자의 기량에 대한 의존도가 높다는 문제점을 가지고 있다. 이에 대한 대안으로 자동 초음파탐상시험 기법의 하나인 TOFD의 적용이 확산되고 있다. 본 연구는 결함을 포함한 시험편에 대하여 방사선투과 시험과 TOFD 기법을 적용하고 비교한 결과를 기술하였다. TOFD 기법은 초음파 시험기법의 객관적 신뢰도 향상에 기여하게 될 것으로 판단된다.

Keywords

References

  1. ASME Code Case 2235-9 ('05 App.), 'Use of ultrasonic examination in lieu of radiography'
  2. FORCE Technology, 'TOFD general principles & manual'
  3. 이순흠, 김선형, 공용해, 이원흠, 'TOFD 법에서의 근거리 분해능 향상에 관한 연구', 비파괴검사학회지, Vol. 19, No. 6, pp 420-425, (1999)