• Title/Summary/Keyword: film transfer system

Search Result 205, Processing Time 0.028 seconds

Local Heat Transfer Coefficients for Reflux Condensation Experiment in a Vertical Tube in the Presence of Noncondensible Gas

  • Moon, Young-Min;No, Hee-Cheon;Bang, Young-Seok
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1999.05a
    • /
    • pp.104-104
    • /
    • 1999
  • The local heat transfer coefficient is experimentally investigated for the reflux condensation in a countercurrent flow between the steam-air mixture and the condensate. A single vertical tube has a geometry which is a length of 2.4m, inner diameter of 16.56mm and outer diameter of 19.05mm and is made of stainless steel. Air is used as a noncondensible gas. The secondary side is installed in the form of coolant block around vertical tube and the heat by primary condensation is transferred to the coolant water. The local temperatures are measured at 15 locations in the vertical direction and each location has 3 measurement points in the radial direction, which are installed at the tube center, at the outer wall and at the coolant side. In three different pressures, the 27 sets of data are obtained in the range of inlet steam flow rate 1.348 -3.282kg/hr, of inlet air mass fraction 11.8 -55.0%. The local heat transfer coefficient increases as the increase of inlet steam flow rate and decreases as the decrease of inlet air mass fraction. As an increase of the system pressure, the active condensing region is contracted and the heat transfer capability in this region is magnified. The empirical correlation is developed represented with the 165 sets of local heat transfer data. As a result, the Jacob number and film Reynolds number are dominant parameters to govern the local heat transfer coefficient. The rms error is 17. 7% between the results by the experiment and by the correlation.

  • PDF

Analysis on Wetting Behavior of A Lamellar Type Wet Channels in An Evaporative Heat Exchanger (층상구조를 가진 증발식 열교환기 습채널의 표면 젖음도 해석)

  • Oh, Dong-Wook;Park, Jae Bum;Song, Chan Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.7
    • /
    • pp.283-287
    • /
    • 2016
  • One of the most important factors for determining the thermal performance of an evaporative cooling system is the wettability of the evaporative heat exchanger surface. Evaporation of a widely spread water film on the heat exchanger surface promotes heat transfer between the "dry" air and "wet" air passages. Hydrophilic coating is generally applied on the heat exchanger surfaces to increase the wettability of the heat exchanger surface and the COP of the evaporative cooling system. In this paper, a simple lamellar patterned structure is suggested to maximize the spreading of a water film on the vertically oriented walls. The capillary height of the lamellar structured grooves is analyzed through a theoretical model, and the results are compared with the numerical analysis through a finite element analysis tool, SE-FIT. A good agreement between the theoretical model and the numerical analysis can be observed as long as the channel depth is comparable to or larger than the channel width of the lamellar structure.

A study on the accuracy of source position in HDR brachytherapy according to the curvature of Universal applicator transfer tube and applicator type (원격 후 장전치료기를 사용한 고선량률 근접치료시 기구의 형태와 선원 전달 도관의 곡률 변화에 따른 선원위치 정확성에 관한 고찰)

  • Shin, Hyeon Kyung;Lee, Sang Kyoo;Kim, Joo Ho;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • Purpose : The goal of this study was to verify and analyze the source position according to the curvature of the universal applicator and 4 different angle applicators when using RALS(Remote After Loading System). Materials and Methods : An interval of 1 cm and 15 second dwell times in each source position were applied for plan. To verify the accuracy of source position, we narrowed the distance between MultiSource container and GAFCHROMIC$^{(R)}$ EBT3 film by 5 cm, 10 cm, 20 cm so that the universal applicator transfer tube had some curvature. Also 4 applicators(Intrauterine tube: $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, Ovoid tube: $65^{\circ}$) were used in the same condition. The differences between desired and actual source position were measured by using Image J. Results : In case of using 4 different angles of applicator with the straight universal applicator transfer tube, the average error was the lowest for $0^{\circ}$ applicator, greatest for $65^{\circ}$ applicator. However, All average errors were within ${\pm}2mm$ recommended in TG-56. When MultiSource container was moved 5 cm, 10 cm, 20 cm towards the EBT3 film, the average errors were beyond ${\pm}2mm$. The first dwell position was relatively located in accuracy, while the second and third dwells were displaced by an increasing magnitude with increasing curvature of the transfer tube. Furthermore, with increasing the angle of applicators, the error of all other dwell positioning was increased. Conclusion : The results of this study showed that both the curvature of universal applicator transfer tube and the angle of applicators affect the source dwell position. It is recommended that using straight universal applicator transfer tubes is followed in all cases, in order to avoid deviations in the delivered source dwell position. Also, It is advisable to verify the actual dwell position, using video camera quality control tool prior to all treatments.

  • PDF

Heat Transfer Characteristics Around a Surface-Mounted Module Cooled by Piezoelectric Fan (압전세라믹 냉각홴에 의한 강제 공랭 모듈 주위의 열전달특성)

  • Park, Sang-Hee;Park, Gyu-Jin;Choi, Seong-Dae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.7
    • /
    • pp.780-788
    • /
    • 2004
  • This paper reports the fluid flow and heat transfer around a module cooled by forced air flow generated by a piezoelectric(PZT) cooling fan. The fluids are locally accelerated by a flexible PZT fan which deflects inside a fluid transport system of comparatively simple structure mounted on a PCB in a parallel-plate channel(450${\times}$80${\times}$700㎣). Input voltages of 20-100V and a resonance frequency of 23㎐ were used to vibrate the cooling fan. Input power to the module was 4W. The fluid flow around the module was visualized by using PIV system. The temperature distributions around a heated module were visualized by using liquid crystal film(LCF). The cooling effect using a PZT fan was independent of the vent area ratios at the channel inlet and was similar to the forced convection cooling. We found that the flow type was Y-shape and the cooling effect was increased by the wake generated by a piezoelectric cooling fan.

3D Numerical Study of Horizontal Falling Film Evaporator in Multi Effect Distillation (MED) Plant (MED 담수기내 수평관 강하막식 증발기의 3D 수치해석적 연구)

  • Kim, Soo Jae;Je, Junho;Kim, Moo Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.513-522
    • /
    • 2013
  • In the present work, a numerical study of a horizontal falling film evaporator in a multi-effect distillation (MED) plant is performed. Tube bundles in the evaporator are described as porous media, and a volume-averaged method is applied. To calculate the fluid flow and phase change in the evaporator due to heat transfer in the system, FLUENT and user-defined functions (UDF) are used. To observe the performance of the evaporator under different operational conditions, tests are conducted for a steam mass flux ranging from 0.5 to 2.5 $kg/m^2s$ in the horizontal tube, for mass fraction of the noncondensable gas in the tube inlet ranging from 0% to 1%, and for film Reynolds numbers ranging from 100 to 1,000 for the falling film. The evaporation rate increases with the steam mass flux and Reynolds number. In contrast, the evaporation rate decreases by 0.87% with a 1% increase in the mass fraction of the noncondensable gas in the tube.

Terahertz Time Domain Spectroscopy, T-Ray Imaging and Wireless Data Transfer Technologies

  • Paek, Mun-Cheol;Kwak, Min-Hwan;Kang, Seung-Beom;Kim, Sung-Il;Ryu, Han-Cheol;Choi, Sang-Kuk;Jeong, Se-Young;Kang, Dae-Won;Jun, Dong-Suk;Kang, Kwang-Yong
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.3
    • /
    • pp.158-165
    • /
    • 2010
  • This study reviewed terahertz technologies of time domain spectroscopy, T-ray imaging, and high rate wireless data transfer. The main topics of the terahertz research area were investigation of materials and package modules for terahertz wave generation and detection, and setup of the terahertz system for time domain spectroscopy(TDS), T-ray imaging and sub-THz wireless communication. In addition to Poly-GaAs film as a photoconductive switching antenna material, a table-top scale for the THz-TDS/imaging system and terahertz continuous wave(CW) generation systems for sub-THz data transfer and narrow band T-ray imaging were designed. Dielectric properties of ferroelectric BSTO($Ba_xSr_{1-x}TiO_3$) films and chalcogenide glass systems were characterized with the THz-TDS system at the THz frequency range. Package modules for terahertz wave transmitter/receiver(Tx/Rx) photoconductive antenna were developed.

Research of Energy Efficiency for Power Plant Performance Improvement (발전성능 향상을 위한 에너지 효율 연구)

  • Lee, Jae-Keun;Moon, Jeon-Soo
    • Journal of Hydrogen and New Energy
    • /
    • v.21 no.3
    • /
    • pp.220-226
    • /
    • 2010
  • The heat transfer performance improvement in closed cooling water system of an electric power generation can be achieved by a corrosion control using corrosion inhibitors. The effect of trisodium phosphate and sodium nitrite upon carbon steel at various $Cl^{-1}$ ion containing water concentrations was examined by an integrated corrosion monitoring system. Nitrite was found to be the most effective inhibitor among tested inhibitors for carbon steel. The inhibiting process is considered as adsorption of nitrite ions in oxide layer which form a passive film on the carbon steel surface.

Coupled Transverse Vibrations of Propeller-Shaft Systems (추진축계(推進軸系)의 연성횡진동(聯成橫振動)에 관(關)하여)

  • Si-Young,Ahn
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.22 no.1
    • /
    • pp.38-44
    • /
    • 1985
  • A computer program was developed for the analysis of the coupled transverse vibrations of a multi-supported shaft system. The program, based on the theory of Transfer Matrix Method, was written including the system parameters such as the entrained water and gyroscopic effects of the propeller, the rigidity of bearing combined with the oil film effect, and the whirling frequency of the shaft. The program was used to calculate the resonance frequency of the shafting system of the ship Hanbada. The results show good agreement with the measured values. The results are also compared with those of F.E.M. from the comparison, it is found that both results agree well with each other.

  • PDF

Image Transfer Using Cellular Phones and Wireless Internet Service

  • Shin, Dong-Ah;Doo, Tae-Hoon;Kim, Hyo-Jun;Kim, Hyoung-Ihl
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.6
    • /
    • pp.471-474
    • /
    • 2006
  • Objective : Neuroimaging data are of paramount importance in making correct diagnosis. We herein evaluate the clinical usefulness of image transfer using cellular phones to facilitate neurological diagnosis and decision-making. Methods : Selected images from CT, MRI scans, and plain films obtained from 50 neurosurgical patients were transferred by cellular phones. A cellular phone with a built-in 1,300,000-pixel digital camera was used to capture and send the images. A cellular phone with a 262,000 color thin-film transistor liquid crystal display was used to receive the images. Communication between both cellular phones was operated by the same wireless protocol and the same wireless internet service. We compared the concordance of diagnoses and treatment plans between a house staff who could review full-scale original films and a consultant who could only review transferred images. These finding were later analyzed by a third observer. Results : The mean time of complete transfer was $2{\sim}3\;minutes$. The quality of all images received was good enough to make precise diagnosis and to select treatment options. Transferred images were helpful in making correct diagnosis and decision making in 49/50 [98%] cases. Discordant result was caused in one patient by improper selection of images by the house staff. Conclusion : The cellular phone system was useful for image transfer and delivery patient's information, leading to earlier diagnosis and initiation of treatment. This usefulness was due to sufficient resolution of the built-in camera and the TFT-LCD, the user-friendly features of the devices, and their low cost.

A Study on the Development of Icing by Injection of LPG in the Liquid Phase around Injector (I) (LPG 액상 분사 시 인젝터 주위의 Icing 현상에 관한 연구 (I))

  • 김우석;박정철;박심수;유재석;이종화
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.1
    • /
    • pp.87-94
    • /
    • 2003
  • Recently, LPLi(Liquied-Phase LPG injection) system is studied for the new stringent emission regulations. But , there are some problems to be solved such as injector tip icing and fuel leakage for LPLi system development. In this paper, the icing problem near injector tip which leads to difficulty of accurate A/F control was studied and reported. Icing of injector tip and port wall was observed at all the cases in this study regardless of injection duration and angle, air humidity change. The spray angle of LPLi was observed approximately two times wider than that of Gasoline injection. This makes the LPLi spray collide with intake port around injector tip. Temperature of the wetted area was decreased and icing of water vapor contained in intake air because of evaporation of the fuel film. The ice of the injector tip and port wall is also affected by the materials related to heat transfer.