• 제목/요약/키워드: film dosimetry

검색결과 162건 처리시간 0.041초

유기 섬광체-광섬유 방사선 센서를 이용한 근접 방사선원 Ir-192의 상대 깊이 선량율 측정 (Measurements of relative depth dose rates for a brachytherapy Ir-192 sourceusing an organic scintillator fiber-optic radiation sensor)

  • 신상훈;장경원;조동현;유욱재;서정기;이봉수;문주현;김신;박병기
    • 센서학회지
    • /
    • 제17권6호
    • /
    • pp.462-469
    • /
    • 2008
  • In this study, we have fabricated a fiber-optic radiation sensor using an organic scintillator and plastic optical fiber for brachytherapy dosimetry. Also, we have measured relative depth dose rates of Ir-192 source using a fiber-optic sensor and compared them with the results obtained using a conventional EBT film. Cerenkov lights which can be a noise in measuring scintillating light with a fiber-optic sensor are measured and eliminated by using of a background optical fiber. It is expected that a fiber-optic radiation sensor can be used in brachytherapy dosimetry due to its advantages such as a low cost, simple usage and a small volume.

피사체(被射體)두께에 따른 선량분포(線量分布) (Dosimetry according to the Object Thickness)

  • 이상석;박성옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제2권1호
    • /
    • pp.85-88
    • /
    • 1979
  • When X-radiation passes through the human body; some is transmitted some is truly absorbed, and some is scattered. In diagnostic radiography, scattered radiation can reach the film if no protective measures are taken. This scattered ray increased density which not necessary for image formation. We studied about absorbtion, scattered ray and the way of get rid of scatter ray according to the x-ray tube kilovoltage and obtained results as follow; 1. Absorbtion ray increased proportion to KVP. 2. Scattered ray increased at high KVP and thick object. 3. Secondary radiation of the primary increased at high KVP and thick object. 4. Remove .ate of scattered ray decreased at thick object and increase at low KVP make use of 6:1 grid ratio

  • PDF

IMRT QA에 대한 방법과 평가 (QA Method and Evaluation of IMRT)

  • 이두현;김선영;심진섭;최윤경;이윤석;이기호;염두석
    • 대한방사선협회지
    • /
    • 제30권1호
    • /
    • pp.49-57
    • /
    • 2004
  • I. Purpose : Measure the absolute point dose and film dosimetry in intensity modulated radiation therapy (IMRT) of head and neck cancers. A comparison of objective view between measured and calculated dose dlistribution look through optimization algorithm

  • PDF

방사선 치료시 인공고관절 삽입에 의한 불균질면에서의 선량분포 평가 (Determination of Dose Distribution under Nonequivalent Condition by Prosthesis in Radiotherapy)

  • 이준일;김성환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권2호
    • /
    • pp.43-46
    • /
    • 1998
  • When a patient was irradiated with prosthetic hip, the dose distribution was changed according to inhomogeneous materials. The density, effective atomic number, and the composition of material had influence on absorbed dose distribution. In this study, the influence of inhomogeneous material(Ti) was measured using a polyethylene phantom, which consisted of various diameter of titanium, with film dosimetry. As a result, the backward dose showed 29.5% increas by backscattering, the forward dose showed 28% decreas by absorption, and the side dose showed 7% increas by scattering, when 25 mm diameter Ti was used. In addition forward dose was in inverse proportion to the thickness of prosthetic material. When the prosthetic hip of patient is in an irradiated field, we must carefully study the absorbed dose distribution.

  • PDF

X선진단(診斷) 영역(領域)에 있어서의 심부선량분포(深部線量分布)의 측정(測定) (Measurement of Dose Distribution for Diagnostic X-ray)

  • 김유현;허준;김성철;윤종민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제18권1호
    • /
    • pp.55-62
    • /
    • 1995
  • This study was performed to find out dose distribution, pdd, surface dose and off center ratio. A few articles is analysis of dose data in radiotherapy field, there is no standardized measure of an assessment of exposure dose at diagnostic radiology, yet. And authors demonstrated a new assessment measure by ion chamber, TLD and film dosimetry system. We assurance that our data is useful to quantiative analysis of exposure dose and clinical fields for reduction of radiation dose.

  • PDF

Dosimetry of Ho-166 Balloon Catheter Using GafChromic Film

  • Joh, C.W.;Jang, J.S.;Park, C.H.;Kang, H.J.;Kim, M.H.;Chun, M.S.;Oh, Y.T.;Kim, H.S.;Choi, B.I.W.;Park, K.B.;Kim, Y.K.;Kim, K.H.;Vahc, Y.W.;Lee, B.K.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 1999년도 Japanese Journal of Medical Physics
    • /
    • pp.131-132
    • /
    • 1999
  • PDF

고선량률 강내 근접치료시 열형광량계를 이용한 선량측정법 (TLD Dosimetry in HDR Intracavitary Brachytherapy)

  • Kim, Chang-Seon;Yang, Dae-Sik;Kim, Chul-Yong;Park, Myung-Sun
    • 한국의학물리학회지:의학물리
    • /
    • 제11권2호
    • /
    • pp.109-116
    • /
    • 2000
  • 자궁경부암 환자의 방사선 조사시 고려하여야 할 사항 중 한가지는 결정 장기인 방광 및 직장의 부작용이다. 강내 고선량률 근접 치료시 방광과 직장의 흡수선량을 열형광량계 선량측정법을 이용하여 간접적으로 측정하였다 방광 및 직장의 부작용을 줄일 수 있는 방법이 제안되었다. 방사선 치료 후 예후관찰 중인 200명의 자궁경부암 환자의 자기공명 영상에서 자궁경부의 중심축에서 방광 및 직장 그리고 자궁벽의 두께를 측정하였다. 밀봉시킨 열형광량계를 오보이드의 팩킹거즈 위에 놓고 씨물레이션 필름 상에서 오보이드의 중심에서부터의 거리를 측정한 후 실제의 방광과 직장의 흡수선량을 계산하였다. 발표된 연구결과들에서 방광 및 직장의 최대 견딤선량을 계산하였고 고선량률 근접치료 1회당의 허용선량을 토대로 양방향의 팩킹두께를 알아냈다 방광과 직장방향의 최소의 팩킹두께는 각각 0.43 과 0.92 cm 이었다. 이 결과를 마이스버거 다항식을 이용한 계산결과와 비교하였다. 본 연구에서 제시한 방법이 임상에서 고선량률 근접 치료시 방광과 직장 같은 결정장기의 흡수선량을 평가하는 방법으로 사용되기를 바란다.

  • PDF

6-MV선형가속기를 이용한 입체방사선수술의 선량측정 및 3차원적 치료계획 (Dosimetry and Three Dimensional Planning for Stereotactic Radiosurgery with SIEMENS 6-MV LINAC)

  • 최동락;조병철;서태석;정수미;최일봉;신경섭
    • Radiation Oncology Journal
    • /
    • 제11권1호
    • /
    • pp.175-181
    • /
    • 1993
  • 방사선수술을 시행하기 위해서는 종양의 위치결정, 흡수선량 계산, 그리고 치료를 위한 특수제작된 기구와 컴퓨터 프로그램이 요구된다. 본 연구의 목적은 선형가속기의 전반적인 기계적 정밀도를 확인하고 선형가속기를 이용한 방사선수술에 있어서의 선량계산 알고리즘을 개발하는 것이다. 치료기계의 정렬과 전반적인 치료체계의 성과에 대한 점검을 행하였고 백분율 심부선량, 중심축외 선량비, 그리고 출력인자와 같은 기본 계산자료를 측정하였다. 또한, 입체방사선수술을 위한 3차원적 치료계획 체계를 개발하였다. 선량분포를 계산하기 위하여 C-언어를 이용한 컴퓨터 프로그램을 작성하였고 하드웨어로는 IBM PS/2 (Intel 80386 SX, 24 MHz)를 사용하였다. 그 결과, 주 병원이 보유한 선형가속기의 겐트리와 테이블 회전에 따른 중심점에 대한 오차는 2 mm 이내로 방사선수술을 시행하기에 충분하였다. 팬톰실험에 따르면, 컴퓨터 단층촬영을 이용한 위치결정을 포함한 표적에의 빔의 일치도는 역시 2mm 이내였다. 끝으로, 본원에서 개발한 3차원적 치료계획의 정확도는 필름을 이용한 선량측정을 통하여 입증되었다.