References
- K. H. Beck, J. Drees, K. Goldmann, I. M. Gregor, and M. Heintz, "A multichannel dosimeter based on scintillating fibers for medical application", Nucl. Instru. and Meth. in Phys. Res., vol. 454, no. 1, pp. 147-151, 2000 https://doi.org/10.1016/S0168-9002(00)00817-2
- C. Dilcher, R. Chan, B. L. Justus, P. Falkenstein, A. L. Huston, and R. Waksman, "Dose mapping porcine coronary arteries using an optical fiber dosimeter", Cardiovascular Revascularization Medicine, vol. 6, no. 4, pp. 163-169, 2005 https://doi.org/10.1016/j.carrev.2005.10.002
- T. Nakano, N. Suchowerska, M. M. Bilek, D. R. McKenzie, N. Ng, and T. Kron, "High dose-rate brachytherapy source localization: positional resolution using a diamond detector", Phys. Med. Biol., vol. 48, no. 14, pp. 2133-2146, 2003 https://doi.org/10.1088/0031-9155/48/14/307
- B. Lee, W. Y. Choi, and J. K. Walker, "Polymer-polymer miscibility study for plastic gradient index optical fiber", Polymer Eng. and Sci., vol. 40, no. 9, pp. 1996-1999, 2000 https://doi.org/10.1002/pen.11331
- 황영묵, 조동현, 이봉수, 조효성, 김신, "무기 섬광체를 이용한 플라스틱 광섬유 방사선 센서부 제작 및 특성평가", 센서학회지, 제14권, 제4호, pp. 244-249, 2005 https://doi.org/10.5369/JSST.2005.14.4.244
- J. Lambert, D. R. McKenzie, S. Law, J. Elsey, and N. Suchowerska, "A plastic scintillation dosimeter for high dose rate brachytherapy", Phys. Med. Biol., vol. 51, pp. 5505-5516, 2006 https://doi.org/10.1088/0031-9155/51/21/008
- A. S. Beddar, T. R. Mackie, and F. H. Attix, "Water equivalent plastic scintillation detectors for high-energy beam dosimetry-. Properties and measurements", Phys. Med. Biol., vol. 37, no. 10, pp. 1901-1913, 1992 https://doi.org/10.1088/0031-9155/37/10/007
- 강세식 외 19명, 방사선 치료학, 도서출판 대학서림, pp. 348-350, 2001
- Khan. Faiz M., The Physics of Radiation Therapy, 2nd ed., Williams & Wilkins, Baltimore, Maryland, USA, pp. 434, 1994
-
C. Mori, et al., "Measurement of neutron and
$\gamma$ -ray intensity distributions with an optical fiber-scintillator detector", Nucl. Inst. and Meth. in Phys. Res., vol. 422, pp. 129-132, 1999 https://doi.org/10.1016/S0168-9002(98)01088-2 - 장경원, 조동현, 정순철, 전재훈, 이봉수, 김 신, 조효 성, 박성용, 신동호, "고에너지 전자선 측정을 위한 광섬유 방사선 센서에서의 체렌코프 빛 측정 및 분 석", 센서학회지, 제15권, 제3호, pp. 186-191, 2006 https://doi.org/10.5369/JSST.2006.15.3.186
- A. S. Kirov, Z. Piao, S. Devic, et al., "An estimate of the perturbing effect of cerenkov radiation to the signal from a liquid scintillator volume irradiated by a megavoltage photon beam", Proc. of the 22nd Annual EMBS International Conf., pp. 3148-3151, chicago, USA, 2000
- Frelin et al., "Spectral discrimination of Derenkov radiation in scintillating dosimeters", Med. Phys., vol. 32, no. 9, pp. 3000-3006, 2005 https://doi.org/10.1118/1.2008487
- 강세식, 고성진, 장은성, "Gafchromic EBT 필름을 이용한 선량분포의 평가", 방사선기술과학, vol. 30, no. 2, pp. 139-145, 2007
Cited by
- Measurement of relative dose irradiated from a Co-60 source using a scintillating fiber-optic dosimeter vol.19, pp.1, 2010, https://doi.org/10.5369/JSST.2010.19.1.052
- Afterglow Properties of LLBO Scintillation Crystal vol.23, pp.6, 2014, https://doi.org/10.5369/JSST.2014.23.6.416