• 제목/요약/키워드: filed test

검색결과 170건 처리시간 0.026초

환경친화 식생용 포러스콘크리트의 현장적용성에 관한 연구 (A Study on the Filed Application of Environmental Friendly Porous Concrete For Planting)

  • 김정환;이남익;이용희;권혁준;이준;박승범
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.769-772
    • /
    • 2005
  • The river environments of many streams in korea have been deteriorate through the rapid industrialization and urbanization since the 1960s. In Germany and Japan, on the other hand, much efforts on the research and project have been made for the restoration of the deteriorated streams to close-to-nature. in order to restore the deteriorated streams, therefore, it is necessary to investigate such advanced technologies and materials. In view of this requirement, various research paths are being taken focusing on coarse aggregates to make multi-functional porous concrete having continuous voids so as to improve water and air permeability, acoustic absorption, water purification, and applicability to vegetation. The Purpose of this study is to investigate the method for recovery of the environment in the streams area using porous concrete block. the porous concrete block applies for test in the cheonggae-cheon have been monitored planting during six month. after 6 months, plant grows flourishing and reconstructed in state such as nature rivers.

  • PDF

3차원 CFD해석을 이용한 환형 역류형 연소기설계 (DESIGN OF ANNULAR REVERSIBLE COMBUSTOR WITH 3 DIMENSIONAL CFD ANALYSIS)

  • 나상권;심재경;박희호;이성준;전승배
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.247-251
    • /
    • 2010
  • It is very difficult to understand and estimate the heat transfer and flow characteristics in the combustor, which is one of main components in the Auxiliary Power Unit (APU), because its flow filed has very complex structure. In this paper, specified is characteristics of injection and flow through different air goles in the liner, which consist of large circular holes film cooling holes, and tangential air swirl holes. The durability of the liner depends on whether the surface of the liner is exposed to the hot gas over 1000 $^{\circ}C$ of a temperature or net. It is proved that the locations of hot spots estimated from the calculation using CFD are matched well with that from the test. In this study, CFD simulations were performed to examine the heat transfer and temperature distributions in and about a liner wall with film cooling on the wall. This computational study is based on the ensemble average continuity, compressible Navier-Stokes, energy, and PDF combustion equations closed by the standard $k-{\varepsilon}$ turbulence model with standard wall functions for the gas phase and the Fourier equations for conduction in the solid phase.

  • PDF

박스형 모델에 의한 슬로싱 하중에 관한 실험적 연구 (An Experimental Study on Rectangular Box Sloshing)

  • 정동우;전수성;박준수;권순홍;장택수
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.386-391
    • /
    • 2006
  • This study presents experimental results of sloshing phenomenon done on rectangular box. A simple harmonic excitation was done on the box. Two kinds of filling ratio, 20% and 30% of height, were tested. A total of 15 pressure sensors were installed to monitor the impact pressure. Each test was repeated for 20 times to ensure the repeatability. The high speed camera captured the flaw filed and the corresponding pressure were synchronize with video signal so that the video image can help the interpretation of the impact pressure. The two filling ratio made difference in the flaw characteristic and impact pressure. The use of high speed camera made it possible to understand the bubble generation mechanism. The pressure time histories were presented.

  • PDF

Screening of Cyanobacteria (Blue-Green algae) from Rice Paddy Soil for Anti-fungal Activity against Plant Pathogenic Fungi

  • Kim, Jeong-Dong
    • Mycobiology
    • /
    • 제34권3호
    • /
    • pp.138-142
    • /
    • 2006
  • Soil cyanobacteria isolated from the rice paddy fields of 10 different locations across Korea were evaluated by agar plate diffusion test for antifungal activity. Aqueous, petroleum ether, and methanol extracts from one hundred and forty two cyanobacterial strains belonging to the 14 genera were examined for antifungal properties against seven phytopathogenic fungi causing diseases in hot pepper (Capsicum annuum L). Of total cyanobacteria, nine cyanobacteria (6.34%) exhibited antifungal effects. The nine cyanobacteria selected with positive antifungal activities were two species of Oscillatoria, two of Anabaena, three of Nostoc, one of Nodularia, and one of Calothrix. Alternaria alternata and Botrytis cinerea were inhibited by nine and eight species of cyanobacteria, respectively. Rhizopus stolonifer was suppressed by only methanol extract of Nostoc commune FK-103. In particular, Nostoc commune FK-103 and Oscillatoria tenuis FK-109 showed strong antifungal activities against Phytophthora capsici. Their antifungal activity at the late exponential growth phase is related to the growth temperature and not associated with the growth parameters such as cell biomass and $chlorophyll-{\alpha}$ concentration. The high inhibition levels of antibiotics were 22.5 and 31.8 mm for N. commune FK-103 and O. tenuis FK-109, respectively. The optimal temperature for antibiotic productivity was $35^{\circ}C$.

듀얼 슈퍼 클러스터 헤드 해양 센서 네트워크 라우팅 프로토콜 (Dual Super Cluster Head Underwater Sensor Network Routing Protocol)

  • 장영일;신수영;박현문;박수현
    • 한국시뮬레이션학회논문지
    • /
    • 제15권4호
    • /
    • pp.87-96
    • /
    • 2006
  • 무선 센서 네트워크는 다양한 분야에서 연구되고 있다. 그 중 해양 센서 네트워크는 해양 환경 감시와 같은 다양한 목적으로 사용 될 수 있다. 그러나 무선 센서 네트워크는 주로 지상에서 연구된다. 기존에 지상에서의 연구는 해양에 적용하기에 부적합하다. 따라서, 해양 환경을 고려한 해양 센서 네트워크 구조를 제안한다. 본 논문에서는 해양 센서 네트워크에 클러스터링 기법과 기능별 노드 구축을 적용하였다. 각 클러스터는 클러스터 데이터를 수집하여 전송한다. 이중의 슈퍼 클러스터 헤드는 각각 수신한 클러스터 데이터를 베이스 스테이션에 전송한다. 제안한 해양 음파 센서 네트워크 라우팅 알고리즘을 구현하고, 테스트 베드를 구축하여 클러스터 데이터의 수신율을 분석한다.

  • PDF

운행선상의 연약노반 시험부설구간에서의 장기계측을 통한 거동 특성 (Characteristics of Behavior of the Soft Roadbed through Long-Term Instrumentation on the Field Test)

  • 이진욱;최찬용;이성혁;이창열
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1058-1064
    • /
    • 2004
  • As one of reinforcing methods for soft roadbed, the problems that mud-pumping and settlement occurred by soft roadbed, were investigated, evaluated and analyzed through installing relatively economical and efficient geosynthetics on the selected track-bed for testing. Mock-heang to Dong-ryang on the filed resting sections in the Chung-buk lines were selected as investigating the state of track and prepared field after selecting three of 1,700 spots which often make mud-pumping and requiting maintenance for that. Long curved line radiuses(R) of Mock-heang to Dong-ryang are 500m that were installed with 4 types of geosynthetics layers and one ballast layer. Installed testing cross-section is 200m totally with 40 m between places. Strength or prepared roadbed was measured to investigate the state of roadbed and track with constructing(installing) field testing sections and physical properties of roadbed soils were evaluated and analyzed. Also, mud-pumping, settlement of elastic or plastic sleeper, failure or track, wheel-loads, transverse and earth pressures were measured after installing field testing sections.

  • PDF

계측관리를 통한 방조제 바닥보호공의 침투거동분석 (Analysis of Seepage Behavior of Bottom Protection Layer by Filed Monitoring)

  • 강병윤;오영인;김기년;김현태
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.806-813
    • /
    • 2008
  • In this research, mainly research about the structural and functional stability of sea dyke with variation of seepage condition after final closure. The piezometric head (water head in embankment) monitoring system was installed at two representative final closure section. The dredged fine sand filling condition was evaluated by in-situ test results. Also, the numerical analysis was performed to determine the permeability of bottom protection layer filled with dredged fine sand by monitoring results. According to numerical back analysis results, the coefficient of permeability of bottom protection section of is $7.6{\times}10^{-6}$ m/sec. These results are noted that the bottom protection layer of sea dyke was strong and intensively filled with dredged sand. Also, based on the seepage analysis, the seepage flux of this sea dyke was calculated about $2.42m^3$/day/m which is 29% decreased value compare with adjacent sea dyke.

  • PDF

음향 분석 기반 고압가스 충전시설 안전점검 지능 시스템 모델 (Introduction of Intelligent System Model for Safety Monitoring in a High Pressure Filling Station Based on Sound Analysis)

  • 김성주
    • 한국가스학회지
    • /
    • 제21권2호
    • /
    • pp.58-63
    • /
    • 2017
  • 복잡한 플랜트 환경에서의 안전관리는 인적 요인에 의해 좌우되고 있는 상황이다. 이로 인해 인적 오류에 의한 상황 파악의 실패는 심각한 사고의 원인이 되고 있다. 이를 위해 본 논문에서는 청각 정보에 의해 상황을 인지할 수 있도록 함으로써 복잡한 환경에서의 안전점검의 새로운 수단을 제시하고자 하며, 인간에 의한 경험적 정보를 수반한 상황 인지율을 달성하기 위해 지능이론의 기법 중에서 퍼지이론을 적용하여 음향 정보를 이용한 안전진단 시스템을 제안하고자 한다. 고압가스 충전시설은 매우 단순한 형태이며, 향후 더욱 복잡한 플랜트 시설에 적용이 가능할 것으로 전망한다.

건조수축 저감형 유동화제를 사용한 콘크리트의 현장적용 (Field Application of Concrete Using Drying Shrinkage-Reducing Superplasticizer)

  • 신재경;오치현;최진만;이성연;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.13-16
    • /
    • 2006
  • This study investigates filed application in Daebul Free Trade Zone of a flowing method using drying shrinkage-reducing superplasticizer(SRS) and an insulating curing method using double bubble sheets. Test showed that fresh concrete satisfied target slump and air content. A structure adding SRS significantly decreased the total bleeding capacity and accelerated the setting time. As for the crack occurrence, the structure applying the flowing method and double bubble sheets simultaneously exhibited the most favorable crack endurance, while conventional concrete showed more than 1mm size of crack in overall, and a structure applying only the flowing method partially presented micro crack. For the area proportion of crack occurrence, the structure using the double bubble sheets indicated 9.8%, while others applying flowing method was 28%, compared with 100% of conventional one. Standard curing specimens had about $3{\sim}6%$ higher compressive strength than that of specimens cured at adjacent field construction. In addition, using SRS improved about $5{\sim}7MPa$, than that of conventional concrete at 91 days elapse.

  • PDF

환경친화 식생용 포러스콘크리트의 현장적용성에 관한 연구 II (A Study on the Filed application of Environmental Friendly Porous Concrete For Planting)

  • 김정환;이남익;이용희;이준;박승범
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.829-832
    • /
    • 2006
  • The river environments of many streams in korea have been deteriorate through the rapid industrialization and urbanization since the 1960s. In korea, on the other hand, much efforts on the research and project have been made for the restoration of the deteriorated streams to close-to-nature. in order to restore the deteriorated streams, therefore, it is necessary to investigate such advanced technologies and materials. In view of this requirement, various research paths are being taken focusing on coarse aggregates to make multi-functional porous concrete having continuous voids so as to improve water and air permeability, acoustic absorption, water purification, and applicability to vegetation. The Purpose of this study is to investigate the method for recovery of the environment in the streams area using porous concrete painting block. the P.O.C block applies for test in the kyungan-cheon have been monitored planting during six month. after 6 months, plant grows flourishing and reconstructed in state such as nature rivers.

  • PDF