A study on the sensor for measuring the transient electric fields (시변성(時變性) 전계(電界) 측정용(測定用) 센서에 관한 연구)

  • Lee, Bok-Hee;Paek, Yong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.318-321
    • /
    • 1991
  • For measuring the transient electromagnetic fields and related quantities created by disconnector operations in GIS, one needs the wide bandwidth sensors with simple transfer functions. This paper describes a new developed electric field sensor to measure the very fast transient electric fields and voltages, and the measuring principle, design and construction of planar electric field sensor are described. A calibration and/or correction technique of the sensor is investigated which enables an accurate determination of the sensor response to the time-changing electric fields. As a consequence, the low voltage calibrations certify that a rise time of 1.7 [ns] is achieved for the planar electric field sensor and a total bandwidth extending from several Hz to 200 MHz for the measuring system which presents the constant division ratio as a function of frequency.

  • PDF

Experimental Study on the Effect of DC Electric Field on Extinction Characteristics of Counterflow Diffusion Flame (대향류 확산화염의 소염특성에 미치는 직류전기장의 영향에 관한 실험적 연구)

  • Park, I.H.;Kim, M.K.;Won, S.H.;Cha, M.S.;Chung, S.H.
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.253-259
    • /
    • 2006
  • The effect of DC electric fields on the flame extinction was investigated experimentally in counterflow configurations for the methane/oxygen/nitrogen diffusion flame. The electric fields was applied by connecting the high voltage and ground terminals to the upper and lower burners, respectively. In case of having electric fields, several modes of flame extinction was observed according to the electric field intensity and strain rate defined by the exit velocity. To visualize and characterize the flame structure and intensity, planar LIF technique was adopted for OH radicals. Consequently, several length scales, including the flame width, thickness, and height from the burner tip, were introduced to explain the various flame behaviors and to characterize the flame extinctions. It was found that the variation of flame width and the chemical reaction are strongly related to a critical electric field intensity, thus the various modes of diffusion flame extinction could be observed due to the electric fields.

  • PDF

Realization of Acoustic Scattering Holography (산란 음향 홀로그래피의 구현 방법론)

  • 김양한
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.11
    • /
    • pp.1101-1106
    • /
    • 2004
  • There are many difficulties to get the scattered field generated by obstacle which has arbitrary shape or irregular surface impedance by using analytic solution or numerical methods. In this study, we propose a method of which makes acoustic scattering holography that can predict the far-field scattered field based on nearfield measurements. This method provides the scattered fields of each wave-number components of incident fields. We express the relationship of wave-number components between incident fields and scattered fields using scattering matrix which is transfer matrix of wave-number components. Lastly, we prove the relation between wave-number components of incident and scattered field by experiments. The errors which are caused by measurements and decomposition methods are also analyzed.

Characteristics of the Current Density Induced Inside a Worker Near a Neutral Ground Reactor (중성점 접지 리액터 주변 작업자의 인체내부 유도전류밀도 특성)

  • Min, Suk-Won;Lee, Seung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1856-1861
    • /
    • 2010
  • To reduce a high fault current, neutral ground reactors (NGR) were installed in the Korean substation. Current with several harmonic components flows in a NGR due to load unbalance in normal steady state and magnetic fields with several harmonic components are also generated around a NGR. As results of study, we found magnetic fields around a NGR in Korean substation included two harmonics, 180Hz and 540Hz. Magnetic fields of 180 Hz increased 3 times more current density inside a worker near a NGR than same magnitude magnetic fields of 60 Hz. We know a worker near a NGR may not meet ICNIRP guideline of 10(mA/$m^2$) due to several harmonic components.

The calculatation of induced voltages and electromagnetic fields in 154kV sub (154kV 변전소의 전자계와 유도전압계산)

  • Choi, Chang-Hyek;Han, Poong
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1659-1662
    • /
    • 1998
  • This paper is to analyze electromagnetic fields on a 154kV substation system and induced voltages on the substation fence when the network is operating in a normal condition or a fault condition in which one phase is shorted with the overhead ground wire. Also, changing the scalar potential and electromagnetic fields that are changed in accordance with changing resistivity and permeability of ground are studied. A finding of the study is that the scalar potential and electromagnetic fields are raised near the tower: The values of electric field on the corner of fence and at the edge of the ground grid are higher than other locations.

  • PDF

Analyzing Daily Water Level Fluctuations at Banweol Paddy Fields (반월지구의 일별 논담수심의 특성분석)

  • 이남호;정하우;박승우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.30 no.4
    • /
    • pp.117-126
    • /
    • 1988
  • This paper attempts to characterize general tendency in water level fluctuations at paddy fields, that may be important to efficient irrigation water uses Banweol district was chosen to be the study area, and water levels among irrigation practice parameters were measured daily throughout the irrigation periods of 1985-1986. Time series analyses showed that water levels at fields have strong serial correlationships. A rather long term periodicity was also observed from spectral analyses. Correlationships between water levels at adjacent fields ranged 0.4-0.9, indicating wide variations in irrigation practices. The water levels showed little correlationships with meteorological factors like evapotranspiration, nor with irrigation practices like water supply rates. Standard errors of the average water levels were computed for different number of field plots within a block. The results indicated that low level areal coverage of gauging plots may be applied for field monitoring of daily water level fluctuations.

  • PDF

Realization of acoustic scattering holography (산란 음향 홀로그래피의 구현 방법론)

  • 이상협;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.640-644
    • /
    • 2003
  • There are many difficulties to get the scattered field generated by obstacle which has arbitrary shape or irregular surface impedance by using analytic solution or numerical methods. In this study, we propose experimental method of acoustic scattering holography that can predict the far-field scattered field based on nearfield measurements. In particular we can get the scattered fields of each wave-number components of incident fields. We express the relationship of wave-number components between incident fields and scattered fields using scattering matrix which is transfer matrix of wave-number components. Lastly, we prove the relation between wave-number components of incident and scattered field by experiments. The errors which are caused by measurements and decomposition methods are also analyzed.