• Title/Summary/Keyword: field sampling

Search Result 888, Processing Time 0.024 seconds

Field Validation of an IC/Visible Spectrophotometry Method for the Determination of Cr(VI) in Mist (미스트중 6가 크롬 측정을 위한 IC/Visible Spectrophotometry 방법 (Shin & Paik′s Method)의 현장 평가)

  • 신용철;백남원;김상우;김선자;이유미
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.40.1-43
    • /
    • 2002
  • The purpose of this study was to evaluate a new sampling and analytical method for the determination of hexavalent chromium, Cr(VI) in mist from field plating operation. The Procedures of this new method (Shin & Paik's Method) are as the following: Airborne hexavalent chromium is collected on polyvinyl chloride (PVC) filter according to the National Institute for Occupational Safety and Health (NIOSH) Method 7600, and the filter sample is placed in a screw-capped vial and soaked with 2% NaOH/3% Na₂CO₃ solution immediately after sampling. The Cr(VI) sample is analyzed by ion chromatography/visible spectrophotometry (IC/VS) according to the U.S. Environmental Protection Agency (EPA) Method 218.6. The airborne Cr(VI) concentrations measured by this method were compared with those determined by three reference methods: One (NIOSH/EPA Method) consisted of sampling airborne Cr(VI) on PVC filters and storing the sample filters in screw-capped vials according to the NIOSH method, and analyzing Cr(VI) in samples using IC/VS according to the EPA method. The second method (Impinger Method/NaHCO₃) consisted of absorbing airborne Cr(VI) into 0.02 MN/sub a/Hco₃ solution in midget impinger, and analyzing the Cr(VI) in samples using IC/VS. The third method was the OSHA Method Id-215. Using these four different methods, four replicates of air samples were collected at an electroplating process and analyzed simultaneously. Two-way ANOVA and Paired t-test were used to test difference among values determined by the methods. There was no significant difference and a strong correlation (r/sup 2/=0.99) between Cr(VI) concentrations measured by the shin & Paik's Method and an impinger method (p>0.05). However, Cr(VI) concentrations determined by Shin & Paik's Method were Significantly different form those by the NIOSH/EPA Method (p<0.05) or the OSHA method (p<0.05). The Cr(VI) concentrations of Shin & Paik's Method were Significantly higher than those of the NIOSH/EPA Method or the OSHA method. We concluded that the Shin & Paik's Method could prevent Cr(VI) losses caused by reduction and give more reliable results of airborne Cr(VI) concentrations in work environments.

  • PDF

Productivity Analysis and Improvement of the System Form Construction in the Apartment Housing Project (공동주택 SYSTEM FORM 공사의 생산성 분석 및 향상방안 제안)

  • Kim Do-Hyeong;Kim Kyung-Rai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.2 no.3 s.7
    • /
    • pp.101-109
    • /
    • 2001
  • Application of system form is very effective to continuous horizontal or vertical walls of the apartment housing. Though the system forms that are used in the construction field have the advantage of concrete quality improvement and increasing number of usages, there are some problems in reaching early planning scheduling goal due to schedule delay and low productivity. This study is initiated to solve the problem and suggest some improvements searching for reasons that diminish the productivity. A case study was done in apartment construction field where system form was used and the productivity is analyzed by work sampling. Finally, productivity improvements for assembly of the form, internal form and external form are suggested, respectively.

  • PDF

Comparison between the Charcoal Tube Sampling Method and the Diffusive Sampler, and the Applicability of Diffusive Sampler in the Field (확산형포집기(3M OVM #3500)와 활성탄관의 유기용제 포집농도 비교 및 확산형포집기의 현장 적용 가능성)

  • Jang, Sung Ho;Kim, Hyoung-Ah
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.261-269
    • /
    • 2005
  • To investigate the field applicability of a diffusive sampler (3M OVM #3500, passive sampling method) authors conducted a simultaneous measurement of personal organic solvents exposure in the air of the workplaces by charcoal tube with low volume sampler (active sampling method) and diffusive sampler. Samples were collected and analyzed by NIOSH method ($NMAM^{(R)}$) from thirty-eight workers in 12 factories who work in 6 different processes. Geometric mean (GM) and geometric standard deviation (GSD) were used to describe the result. To compare the results of the two methods, paired t-test was used. According to the manual of the exposure assessment of the mixed organic solvents (Ministry of Labor, Korea), Em was calculated. Simple linear regression was used to evaluate the relationship between the two methods. Results were as follows; 1. Eight different solvents (ethyl acetate, n-hexane, toluene, xylene, acetone, isopropyl alcohol, methyl ethyl ketone (MEK), and methyl isobutyl ketone) were detected simultaneously in the two methods and the concentrations of the personal exposure were lower than 0.5 TLV level. The concentration of the charcoal tube method was higher than that of a diffusive sampler in n-hexane and MEK (p<0.05). 2. Em of the charcoal tube method was higher than that of diffusive sampler method but not significantly different and was lower than the OEL (Occupational Exposure Limit) in all 6 processes. 3. There was a significant correlation between the two methods in low concentrations of the 8 organic solvents (p<0.05). In conclusion, there was no difference in charcoal tube method and diffusive sampler method in low concentrations of some organic solvents, diffusive sampler can be applied to assess the personal monitoring in low level exposure.

Evaluating Reliability of Rooftop Thermal Infrared Image Acquired at Oblique Vantage Point of Super High-rise Building (초고층건물의 사각조망에서 촬영된 지붕표면 열화상의 신뢰도 평가)

  • Ryu, Taek-Hyoung;Um, Jung-Sup
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.51-59
    • /
    • 2013
  • It is usual to evaluate the performance of the cool roof by measuring in-site rooftop temperature using thermal infra-red camera. The principal advantage of rooftop thermal infrared image acquired in oblique vantage point of super high-rise building as a remote sensor is to provide, in a cost-effective manner, area-wide information required for a scattered rooftop target with different colors, utilizing wide view angle and multi-temporal data coverage. This research idea was formulated by incorporating the concept of traditional remote sensing into rooftop temperature monitoring. Correlations between infrared image of super high-rise building and in-situ data were investigated to compare rooftop surface temperature for a total of four different rooftop locations. The results of the correlations analyses indicate that the rooftop surface temperature by the infrared images of super high-rise building alone could be explained yielding $R^2$ values of 0.951. The visible permanent record of the oblique thermal infra-red image was quite useful in better understanding the nature and extent of rooftop color that occurs in sampling points. This thermal infrared image acquired in oblique vantage point of super high-rise made it possible to identify area wide patterns of rooftop temperature change subject to many different colors, which cannot be acquired by traditional in-site field sampling. The infrared image of super high-rise building breaks down the usual concept of field sampling established as a conventional cool roof performance evaluation technique.

A PRACTICAL THREE-DIMENSIONAL ESTIMATION TECHNIQUE FOR SPATIAL DISTRIBUTION OF GROUNDWATER CONTAMINANT CONCENTRATIONS

  • Richard Ewing;Kang, Sung-Kwon;Kim, Jeon-Gook;Thomas B.Stauffer
    • Journal of the Korean Mathematical Society
    • /
    • v.38 no.3
    • /
    • pp.523-559
    • /
    • 2001
  • To predict the fate of groundwater contaminants, accurate spatially continuous information is needed. Because most field sampling of groundwater contaminants are not conducted spatially continuous manner, a special estimation technique is required to interpolate/extrapolate concentration distributions at unmeasured locations. A practical three-dimensional estimations method for in situ groundwater contaminant concentrations is introduced. It consistas of two general steps: estimation of macroscopic transport process and kriging. Using field data and nonlinear optimization techniques, the macroscopic behavior of the contaminant plume is estimated. A spatial distribution of residuals is obtained by subtracting the macroscopic transport portion from field data, then kriging is applied to estimate residuals at unsampled locations. To reduce outlier effects on obtaining correlations between residual data which are needed for determining variougram models, the R(sub)p-estimator is introduced. The proposed estimation method is applied to a field data set.

  • PDF

Implementation of Fuzzy Control Algorithm For Nuclear Power Plant Steam Generator Level Control At Field Controller (원자력발전소 증기발생기 수위제어를 위한 퍼지제어기법의 현장 제어기계에의 적용)

  • 박기용;허우성;성풍현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.1
    • /
    • pp.111-121
    • /
    • 1995
  • A fuzzy control algorithm of bell-type membership functions and 9 rules is constructed for narrow range level control of steam generators in nuclear power plants. It is implemented at a field digital distributed controller, a Westinghouse-made controller called Westinghouse Distributed Processing Family(WDPF). Performance for level control of the developed fuzzy controller is compared with that of conventional controller, both at the field controller. For these comparisons, both the fuzzy control algorithm and the conventional PI control algorithm were carefully tuned. Also the sampling time for optimal performance was investigated. The results show that the fuzzy control algorithm is not only better in performance than the conventional algorithm but also much easier to be tuned by operators in the field.

An Invesitgation of Pre-service Teachers Understandings on Magnet (초등학교 예비교사들의 자석에 관한 이해도 조사)

  • 이형철;정승호
    • Journal of Korean Elementary Science Education
    • /
    • v.23 no.2
    • /
    • pp.141-151
    • /
    • 2004
  • Pre-service teachers' understandings on magnet was investigated through the questionnaire method. The questionnaire was composed of 17 questions about the strength of magnet, the magnetized object and the direction of magnetic field around magnet. In this investigation study, 225 pre-service teachers were selected through random sampling method, who were sophomores in a National University of Education. The formation rate of the scientific conceptions on the strength of magnet was 30.3% and that on the direction of magnetic field around magnet was 53.9%. The average formation rate of scientific conception of all questions on magnet was 44.13%, which doesn't seem to be high as expected. It shows that many of subjects of the questionnaire don't understand fully the concept of moleclar magnet model and the superposition effects of magnetic field around magnet. The formation rate of the scientific conception on magnet of females who took courses in sciences in high school were higher than that of females who took courses in arts in high school, which had meaningful difference (p<.05).

  • PDF

Features of the electric and magnetic fields produced by lightning discharges (뇌방전에 의해 발생된 전장 및 자장의 특성)

  • Lee, B.H.;Lee, W.C.;Baek, Y.H.;Cho, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2135-2137
    • /
    • 2005
  • This paper describes the features of electric and magnetic fields produced by lightning discharges. The measuring system consists of fast electric field sensor, crossed-loop magnetic field sensors, signal processing circuit, A/D converter and data acquisition equipment with a 12bit resolution and 10[MS/s] sampling rate. The frequency bandwidth and responsitivity of the electric field measuring system were 40[Hz]${\sim}$2.6 [MHz] and 2.08 (V/m/mV) and those of the magnetic field measuring system were 400[Hz]${\sim}$1[MHz] and 2.78[nT/mV], respectively. The electric and magnetic fields produced by lightning discharges were observed, and the features and parameters of the waveforms were analyzed.

  • PDF

Development of a Groundwater Sampler and Test in a Well Affected by Seawater Intrusion (지하수 샘플러 개발 및 해수침투 관측정에서의 평가)

  • Lee, Bong-Joo;Moon, Sang-Ho;Kim, Gee-Pyo;Kim, Yong-Cheol;Kim, Yong-Je;Koh, Gi-Won
    • The Journal of Engineering Geology
    • /
    • v.18 no.3
    • /
    • pp.331-338
    • /
    • 2008
  • A new ground water sampler was developed and evaluated for target depth sampling under most rigorous field conditions. This new concept sampler comprises an air-cylinder, a hypodermic needle and a sampling bottle. Pressurized air or nitrogen gas can be used as a mechanical power source to operate the sampler. The air-cylinder is used to jab the hypodermic needle into the rubber cap of the sampling bottle. The hypodermic needle functions as a pathway to inject groundwater into the sampling bottle. Field test was conducted in a seawater intrusion monitoring well located at Handong district of Jeju Island. Water qualities in this well are periodically changed from the effects of sea water. Water sampling fir the same target depth in this well were tried at various times, and variations in electrical conductivity and pressure at the inside and outside of the sampler were measured using CTD divers. We found that the device could collect water samples only when it was actuated, and the pattern and range of variations in electrical conductivities and pressures measured at the inside and outside of the sampler were nearly identical. These results indicate that water samples using the sampler presented in this study represent correctly water qualities in which the samplings were made at a specific target depth in a well.

Development of a Water Sampling System for Unmanned Probe for Improvement of Water Quality Measurement (수질측정 방법 개선을 위한 무인 탐사체의 채수장치 개발방안)

  • Jung, Jin Woo;Cho, Kwang Hee;Kim, Min Ji
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.35 no.6
    • /
    • pp.527-534
    • /
    • 2017
  • The purpose of this study is to develop unmanned equipment that can automatically move to the desired point and measure water quality at the correct depth. For this purpose, we constructed a water sampling lift and water sampling container, an unmanned vessel equipped with a VRS-GPS, an acoustic echo sounder, and a water quality sensor. Also, we developed an automatic navigation algorithm and program, an automatic water sampling program, and a water quality map generation program. As a result of the experiment in the detention pond, the unmanned vessel sailed along the planned route with an accuracy of about 93% within the error range of 3m. In addition, the water quality sensor installed in the lift was able to acquire the water quality of the target area in real time and transmit it to the server via wireless Internet, and it was possible to monitor the water quality of each site in real time. Through field experiments, the water sampling lift was able to control the desired length with an accuracy of about 94%. The stretch length accuracy experiment of the water sampling lift was impossible to measure directly in the water, so it was replaced land-based experiment. We also found some unstable problems due to the weight of the water sampling lift and the weight of the air compressor to operate the water container. Except these two problems, we accomplished purpose of this study. An automated water quality measurement method using an unmanned vessel can be used to measure the quality of water in a difficult to access area and to secure the safety of the worker.