• 제목/요약/키워드: field measurements

검색결과 2,758건 처리시간 0.03초

Recent Developments in Magnetic Measurements: from Technical Method to Physical Knowledge

  • Basso, V.;Fiorillo, F.;Beatrice, C.;Caprile, A.;Kuepferling, M.;Magni, A.;Sasso, C.P.
    • Journal of Magnetics
    • /
    • 제18권3호
    • /
    • pp.331-338
    • /
    • 2013
  • We present a few significant advances in methods and concepts of magnetic measurements, aimed both at providing novel routes in the characterization of hard and soft magnetic materials and at improving our basic knowledge of the magnetization process. We discuss, in particular, investigation methods and experimental arrangements that have been developed in recent times for: 1) Hysteresis loop determination in extra-hard magnets by means of Pulsed Field Magnetometry; 2) Broadband observation of domain wall dynamics by highspeed stroboscopical Kerr techniques; 3) Entropy measurements in magnetocaloric materials by calorimetry in magnetic field. While pertaining to somewhat independent fields of investigation, all these measuring techniques have in common a solid approach to the underlying physical phenomenology and have a potential for further developments.

Pressure equalization of rainscreen facades: Analysis of the field data in the frequency domain

  • Kumar, K. Suresh;Wisse, J.A.
    • Wind and Structures
    • /
    • 제4권2호
    • /
    • pp.101-118
    • /
    • 2001
  • This paper reports the field measurements concerning pressure equalization of rainscreen facades carried out at the Technical University of Eindhoven (TUE) in the Netherlands. The field facility including the details of test panel, meteorological tower, instrumentation, data collection and analysis is presented. Results of investigations into cavity response for various leakage and venting configurations are discussed. Frequency domain techniques have been utilized to show the influence of wind as well as facade characteristics on the pressure equalization performance. Further, this paper presents an early attempt to synthesize the experimental results into existing building codes.

Behaviour of field-responsive suspensions under oscillatory shear flow

  • Keentok, Matti;See, Howard
    • Korea-Australia Rheology Journal
    • /
    • 제19권3호
    • /
    • pp.117-123
    • /
    • 2007
  • There has been considerable interest in recent years in field-responsive suspensions, which are of some importance in industry in many different applications. The microstructure of these materials is a significant issue which can be probed by rheological measurements. In this study, measurements were made of a magnetorheological fluid (MRF) under steady and oscillatory shear flow, with and without a magnetic field. Mathematical inversion was used to derive the relaxation time spectrum of the MRF from oscillatory shear data. Experimental evidence is presented of the gel-like properties of this MRF.

공동주택 욕실 배수소음의 현장 측정방법 (Field Measurements on Drain Noise in Bathroom of Apartment House)

  • 양관섭;이태강;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.345-348
    • /
    • 2005
  • The method of measurement for field tests on noise emission from water closet in bathroom of apartment house. This part of standard gives detailed descriptions for field tests on noise emission from water closet in bathroom. The measuring position have to investigated measuring for emission noise.

  • PDF

Field Measurement and Modal Identification of Various Structures for Structural Health Monitoring

  • Yoshida, Akihiko;Tamura, Yukio
    • 국제초고층학회논문집
    • /
    • 제4권1호
    • /
    • pp.9-25
    • /
    • 2015
  • Field measurements of various structures have been conducted for many purposes. Measurement data obtained by field measurement is very useful to determine vibration characteristics including dynamic characteristics such as the damping ratio, natural frequency, and mode shape of a structure. In addition, results of field measurements and modal identification can be used for modal updating of FEM analysis, for checking the efficiency of damping devices and so on. This paper shows some examples of field measurements and modal identification for structural health monitoring. As the first example, changes of dynamic characteristics of a 15-story office building in four construction stages from the foundation stage to completion are described. The dynamic characteristics of each construction stage were modeled as accurately as possible by FEM, and the stiffness of the main structural frame was evaluated and the FEM results were compared with measurements performed on non-load-bearing elements. Simple FEM modal updating was also applied. As the next example, full-scale measurements were also carried out on a high-rise chimney, and the efficiency of the tuned mass damper was investigated by using two kinds of modal identification techniques. Good correspondence was shown with vibration characteristics obtained by the 2DOF-RD technique and the Frequency Domain Decomposition method. As the last example, the wind-induced response using RTK-GPS and the feasibility of hybrid use of FEM analysis and RTK-GPS for confirming the integrity of structures during strong typhoons were shown. The member stresses obtained by hybrid use of FEM analysis and RTK-GPS were close to the member stresses measured by strain gauges.

레이저를 이용한 방전 플라즈마중의 전계측정 기술 동향 (Technical tendency of electric field measurements in glow discharge plasmas using laser spectroscopy)

  • 최영욱;;촌강극기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1663-1665
    • /
    • 1997
  • Direct measurements of electric fields in a glow discharge are difficult because the measurement method should be sensitive to the electric field and non-intrusive. Laser spectroscopy is very suitable in that it is non-intrusive and allow in-situ measurements to be made. In this report, the measurement techniques of electric fields in glow discharge using laser spectroscopy were described.

  • PDF

A Study of Characteristic of Electrical-magnetic and Neutron Diffraction of Long-wire High-superconductor for Reducing Energy Losses

  • Jang, Mi-Hye
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권6호
    • /
    • pp.265-272
    • /
    • 2008
  • In this paper, AC losses of long wire Bi-2223 tapes with different twist pitch of superconducting core were fabricated, measured and analyzed. These samples produced by a powder-in-tube method are multi-filamentary tape with Ag matrix. Also, it's produced by non-twist. The critical current measurement was carried out under the environment in Liquid nitrogen and in zero field by 4-prob method. And the Magnetic measurement was carried out under the environment of applied time-varying transport current by transport method. From experiment, the susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation. Neutron-diffraction measurements have been carried out investigate the crystal structure, magnetic structures, and magnetic phase transitions in Bi-2223([Bi, Pb]:Sr:Ca:Cu:O).

Gaussian process approach for dose mapping in radiation fields

  • Khuwaileh, Bassam A.;Metwally, Walid A.
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1807-1816
    • /
    • 2020
  • In this work, a Gaussian Process (Kriging) approach is proposed to provide efficient dose mapping for complex radiation fields using limited number of responses. Given a few response measurements (or simulation data points), the proposed approach can help the analyst in completing a map of the radiation dose field with a 95% confidence interval, efficiently. Two case studies are used to validate the proposed approach. The First case study is based on experimental dose measurements to build the dose map in a radiation field induced by a D-D neutron generator. The second, is a simulation case study where the proposed approach is used to mimic Monte Carlo dose predictions in the radiation field using a limited number of MCNP simulations. Given the low computational cost of constructing Gaussian Process (GP) models, results indicate that the GP model can reasonably map the dose in the radiation field given a limited number of data measurements. Both case studies are performed on the nuclear engineering radiation laboratories at the University of Sharjah.

선형가속기에서 상위조리개와 하위조리개의 교환에 의한 선량 변화의 고찰 (The study on dose variation due to exchange of Upper and Lower jaw in the linear accelerator)

  • 임충근;김회남;송기원
    • 대한방사선치료학회지
    • /
    • 제11권1호
    • /
    • pp.6-10
    • /
    • 1999
  • The field size can be beam output, therefore MonitorUnit can be varied due to field size dependence The purpose of this study is to evaluate and compare the dose variation according to exchange of collimator The measurements were perfomed with Wellhofer dosimetry system(water phantom. ion chamber. electrometer. system controller. build up cap. etc)and two types of linear accerlerator (Mevatron KD, MevatronMX) Scatter can be affected to field size dependence and scatter correction is separated into collimator and phantom components, scatter components can affect by exchanging of collimator Measurements of collimator scatter factor(Sc) was done in air with build up cap. 1)Square field (5cm2 to 40cm2) was measured 2)and then keeping the upper jaw constant at loom and varing lower jaw from 5cm to 40cm, 3)keeping the lower jaw constant at 10cm and varing upper jaw from 5cm to 40cm Measurements of total scatter factor(Scp) was done in water at Dmax as the procedure of collimator scatter factor measurements in water Dmax The total scatter factors were obtained to the following equation(Sp=Scp/Sc) The measured data is normalized to the data of reference field size($10{\times}10$), rectangular field is inverted to equivalent field to compare three field size data As the collimator setting is varied, the output was changed In conclusion, the error was obtained small but it must be eliminated if we intend to reach the common stated goal of $5\%$ overall uncertainty in dose determination

  • PDF

SQUID를 이용한 뇌 청각유발 자장의 측정 (Measurements of Auditory Evoked Neuromagnetic Fields using Superconducting Quantum Interference Devices)

  • 이용호;권혁찬;김진목;박용기
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권4호
    • /
    • pp.421-428
    • /
    • 1997
  • 초전도양자간섭소자(SQUID)를 이용한 자장센서는 현재 개발된 자장센서중에서 감도가 가장 우수한 소자로서 인체의 두뇌에서 발생하는 매우 미약한 자장에 측정이 가능하다. 뇌자도측정은 현재 많이 사용되고 있는 전기적인 측정(뇌파, 뇌유발전위) 에 비해 공간분해능이 우수하고, fMRI나 PET에 비해서는 시간분해능이 우수하므로 뇌기능연구에 유용하게 사용될 수 있다. 본 연구에서는 뇌자도 측정을 위하여 4-채널 SQUID시스템을 개발하였다. 개발된 시스템의 주요 특징은 새로운 방식의 SQUID센서를 채택함으로서 간단한 회로로써 SQUID구동이 가능하도록 하였으며, 검출코일의 신뢰성을 향상시키기 위하여 집적화된 평면형 코일을 사용하였다. 외부 환경잡음을 소거하기 위하여 자기차폐실을 설치하였고, 개발된 SQUID 시스템을 이용하여 뇌의 청각령으로부터 발생하는 자기신호를 측정하였다.

  • PDF