• Title/Summary/Keyword: field instrument

Search Result 570, Processing Time 0.026 seconds

A basic research for evaluation of a Home Care Nursing Delivery System (가정간호 서비스 질 평가를 위한 도구개발연구)

  • Kim, Mo-Im;Cho, Won-Jung;Kim, Eui-Sook;Kim, Sung-Kyu;Chang, Soon-Bok;Ryu, Ho-Sihn
    • Journal of Home Health Care Nursing
    • /
    • v.6
    • /
    • pp.33-45
    • /
    • 1999
  • The purpose of this study was to develop a basic framework and criteria for evaluation of quality care provided to patients with the attributes of disease in the home care nursing field, and to provide measurement tools for home health care in the future. The study design was a developmental study for evaluation of hospital-based HCN(home care nursing) in Korea. The study process was as follows: a home care nursing study team of College of Nursing. Yonsei University reviewed the nursing records of 47 patients who were enrolled at Yonsei University Medical Center Home Care Center in March, 1995. Twenty-five patients were insured at that time, were selected from 47 patients receiving home care service for study feasibility with six disease groups; Caesarean Section (C/S), simple nephrectomy, Liver cirrhosis(LC), chronic obstructive pulmonary disease(COPD), Lung cancer or cerebrovascular accident(CVA). In this study, the following items were selected : First step : Preliminary study 1. Criteria and items were selected on the basis of related literature on each disease area. 2. Items were identified by home care nurses. 3. A physician in charge reviewed the criteria and content of selected items. 4. Items were revised through preliminary study offered to both HCN patients and discharged patients from the home care center. Second step : Pretest 1. To verify the content of the items, a pretest was conducted with 18 patients of which there were three patients in each of the six selected disease groups. Third step : Test of reliability and validity of tools 1. Using the collected data from 25 patients with either cis, Simple nephrectomy, LC, COPD, Lung cancer, or CVA. the final items were revised through a panel discussion among experts in medical care who were researchers, doctors, or nurses. 2. Reliability and validity of the completed tool were verified with both inpatients and HCN patients in each of field for researches. The study results are as follows: 1. Standard for discharge with HCN referral The referral standard for home care, which included criteria for discharge with HCN referral and criteria leaving the hospital were established. These were developed through content analysis from the results of an open-ended questionnaire to related doctors concerning characteristic for discharge with HCN referral for each of the disease groups. The final criteria was decided by discussion among the researchers. 2. Instrument for measurement of health statusPatient health status was measured pre and post home care by direct observation and interview with an open-ended questionnaire which consisted of 61 items based on Gorden's nursing diagnosis classification. These included seven items on health knowledge and health management, eight items on nutrition and metabolism, three items on elimination, five items on activity and exercise, seven items on perception and cognition, three items on sleep and rest, three items on self-perception, three items on role and interpersonal relations, five items on sexuality and reproduction, five items on coping and stress, four items on value and religion, three items on family. and three items on facilities and environment. 3. Instrument for measurement of self-care The instrument for self-care measurement was classified with scales according to the attributes of the disease. Each scale measured understanding level and practice level by a Yes or No scale. Understanding level was measured by interview but practice level was measured by both observation and interview. Items for self-care measurement included 14 for patients with a CVA, five for women who had a cis, ten for patients with lung cancer, 12 for patients with COPD, five for patients with a simple nephrectomy, and 11 for patients with LC. 4. Record for follow-up management This included (1) OPD visit sheet, (2) ER visit form, (3) complications problem form, (4) readmission sheet. and (5) visit note for others medical centers which included visit date, reason for visit, patient name, caregivers, sex, age, time and cost required for visit, and traffic expenses, that is, there were open-end items that investigated OPD visits, emergency room visits, the problem and solution of complications, readmissions and visits to other medical institution to measure health problems and expenditures during the follow up period. 5. Instrument to measure patients satisfaction The satisfaction measurement instrument by Reisseer(1975) was referred to for the development of a tool to measure patient home care satisfaction. The instrument was an open-ended questionnaire which consisted of 11 domains; treatment, nursing care, information, time consumption, accessibility, rapidity, treatment skill, service relevance, attitude, satisfaction factors, dissatisfaction factors, overall satisfaction about nursing care, and others. In conclusion, Five evaluation instruments were developed for home care nursing. These were (1)standard for discharge with HCN referral. (2)instrument for measurement of health status, (3)instrument for measurement of self-care. (4)record for follow-up management, and (5)instrument to measure patient satisfaction. Also, the five instruments can be used to evaluate the effectiveness of the service to assure quality. Further research is needed to increase the reliability and validity of instrument through a community-based HCN evaluation.

  • PDF

2DF ON THE AAT - PROJECT UPDATE AND FIRST SCIENTIFIC RESULTS

  • CANNON RUSSELL;TAYLOR KEITH
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.367-370
    • /
    • 1996
  • Construction of the 'Two-degree Field' (2dF) instrument on the Anglo-Australian Telescope (AAT) is now virtually complete and commissioning is well underway. The key components are described. Several recent milestones are reported, including the first scientific results. Future prospects and plans are discussed.

  • PDF

Auto-measurement of object by using image processor (영상처리기를 이용한 대상물체의 자동계측)

  • 백남칠;김영일;정영기;최호현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.484-487
    • /
    • 1987
  • In order to measure object larger than the optical field-of-view most video measurement systems utilize some sort of precision staging mechanism, and to utilize such a staging systems, Auto-Measurement System implemented in this paper has a precision of its own which affect the overall repeatability of the measuring instrument.

  • PDF

The Development of Instrument for Standard Performance Assessment for the Practice CNC Lathe of Work Machine Subject in Technical High School (공업고등학교 공작기계 과목의 CNC 선반 실습 표준 수행 평가 기준 개발)

  • Lee, Hyeon-Joong;Lee, Sang-Hyuk
    • 대한공업교육학회지
    • /
    • v.33 no.1
    • /
    • pp.92-113
    • /
    • 2008
  • The purpose of this study is to develop a standard for right performance assessment instrument for the practice CNC Lathe of work machine subject in technical high school. In this study, we developed the standard performance assessment instrument for the practice CNC Lathe through collecting and analyzing the standard performance assessment instrument of CNC Lathe from 13 technical high schools (11 public schools and 2 private schools). The developed standard of performance assessment instrument for the practice CNC Lathe is verified by getting proper estimation from 26 teachers in technical high schools (2 teachers from each school) who are taking charge of CNC Lathe practice, and mean value between 3.77 and 4.77 is very high in validity. The characteristics of assessment instrument developed in this study are as following. First, the standard of performance assessment instrument is redeveloped to evaluate the cognitive domain and affective domain as well as psychomotor domain of technical high school students. Second, the estimation field for practice subject is segmented for all practice processes and intends to do objective estimation which can be carried out by both teachers and students, not only teachers. Third, the developed standard of performance assessment instrument for the practice CNC Lathe has high validity and truthfulness because it is monitored by teachers who are teaching in technical high school.

Virtual Acoustics Field Simulation System for the Soundscape Reproduction in Public (공공장소의 음풍경 재현을 위한 가상음장현장재현시스템 개발)

  • Song, Hyuk;Kook, Chan;Jang, Gil-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.4
    • /
    • pp.319-326
    • /
    • 2004
  • The soundscape is a novel attempt to offer comfortable sound environments at the urban public spaces by adding pleasant sounds and removing unagreeable ones. Most important factors to be considered therein are to determine what kind of sounds to offer and how to adjust them to the changing circumstances. But, installing, maintaining and adjusting the soundscape system directly in the field will ensue numerous problems as well as high costs. Thus, it is essential to devise a test method to analyse and verify the outcome before the actual installation in the field takes place. This study aims at devising the instrument system that enables to control. with a great ease, numerous variables. reproduce most agreeable sound sources, and can verify the effects on the virtual simulatory settings, which is named as Virtual Acoustic Field Simulation System (VAFSS).

A Measurement of Sea Ice Properties at Chukchi Borderland During the Summer (여름철 Chukchi Borderland 부근 해빙 재료특성 계측)

  • Jeong, Seong-Yeob;Choi, Gul-Gi
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.1
    • /
    • pp.45-51
    • /
    • 2012
  • Sea ice properties have been considered a key indicator in the structural design criteria of icebreaking vessels and arctic offshore platforms to estimate design ice load and resistance for their safety management in Arctic Ocean. A measurement study of sea ice properties was conducted during July to August of 2011 with the Korean icebreaking research vessel "Araon" around Chukchi Borderland. The sea ice concentration appears to be rapidly decreasing during this cruise. Ice condition seems to be thick second-year ice and multi-year ice and then, a lot of melt ponds were observed in the surface of ice floe. Calculated flexural strength of sea ice was about 250~550kPa, ice thickness was roughly 1.3~3.0m. In this research we performed field experiment to measure ice temperature along the depth, thickness, density, salinity, brine volume ratio and crystal structure. Apparent conductivities derived with the electromagnetic induction instrument were compared to drill hole measurement results and accuracy of sea ice thickness estimation formula was discussed.

Chief Factors in the Quality of Western Food (서양요리 품질의 결정요인에 관한 연구)

  • 정진우
    • Culinary science and hospitality research
    • /
    • v.7 no.3
    • /
    • pp.275-294
    • /
    • 2001
  • There have been many discussions on the importance and part of quality in the marketing field. It also has been an effort in the cooking field to understand how the quality, recognized by customers, influences customer satisfaction in the process of serving western food. This study is a theory about evaluation methods of western food. It can be summarized in three views as below especially with sensuous evaluation methods. First, it is decoration. Visual factors, such as a receptacle and the amount of food in it, the arrangement of food colors, gloss of food, steam arising of from food, additional garnishes on food should be harmonious. Second, it is a flavor. The factors like the taste and smell of food, and feeling of food in the mouth can be evaluated with the taste and the smell. Third, it is texture. It is considered with the sense of touch, the motor sensation in the mouth and the hearing sense. Especially the sense of touch involves feel of receptacle when it is hot or cold as well as feel of food. This study has been conducted for providing customers with higher-quality western food, which is based on a theoretical study about evaluation methods. During the study, the limit was found that there is no measuring instrument, since the study was restricted in a theoretical work. For more accurate research, the measuring instrument should be developed through the positive research.

  • PDF

Sensitivity Analysis of the Optical System for UV-IR Space Telescope

  • Kim, Sanghyuk;Chang, Seunghyuk;Pak, Soojong;Jeong, Byeongjoon;Kim, Geon Hee;Hammar, Arvid
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.56.4-57
    • /
    • 2015
  • We present the optical design and a sensitivity analysis for a wide field of view (FOV) instrument operating at UV and IR wavelengths. The ongoing investigation is performed in collaboration with Omnisys Instruments (Sweden) and focuses on a telluric-limb-viewing instrument that will fly in a low Earth orbit to study mesospheric wave structures over a wide range of horizontal scales in the altitude range 80 - 100 km. The instrument has six wavelength channels which consist of 4 channels of IR and 2 of UV. We are proposing an optical design based on three mirror aplanatic off-axis reflective system. The entrance pupil diameter and effective focal length are 45 mm and 270 mm, respectively. The FOV is $5.5^{\circ}{\times}1^{\circ}$ and the secondary mirror is set for stop. The optical specification is required to have an encircled energy of at least 80 % within a diameter of 21 um. We performed sensitivity analysis for the longest wavelength of 772 nm in consideration of the diffraction limit of system. The results show that tolerance limits for positions and angles of the mirrors are not very sensitive compared with typical error budgets of manufacturing and assembling process. The secondary mirror has the most sensitive tolerance for surface figure of 250 nm in root-mean-square.

  • PDF

The Design of MSC(Multi-Spectral Camera) Calibration Operation

  • Yong Sang-Soon;Kang Geum-Sil;Jang Young-Jun;Kim Jong-Ah;Kang Song-Doug;Paik Hong-Yul
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.601-603
    • /
    • 2004
  • Multi-Spectral Camera(MSC) is a payload on the KOMPSAT -2 satellite to perform the earth remote sensing. The instrument images the earth using a push-broom motion with a swath width of 15 km and a ground sample distance (GSD) of 1 m over the entire field of view (FOV) at altitude 685 Km. The instrument is designed to have an on-orbit operation duty cycle of $20\%$ over the mission lifetime of 3 years with the functions of programmable gain! offset and onboard image data compression/storage. MSC instrument has one(1) channel for panchromatic Imaging and four(4) channel for multi-spectral Imaging covering the spectral range from 450nm to 900nm using TDI CCD Focal Plane Array (FPA). In this paper, the configuration, the interface of MSC hardware and the MSC operation concept are described. And the method of the MSC calibration are described and the design of MSC calibration operation to measure the change of MSC after Launch & Early Operation(LEOP) and normal mission operations are discussed and analyzed.

  • PDF

Development of Weight Type Snowfall Gauge and Observation (중량식 강설량계 개발과 관측)

  • Lee, Bu-Yong
    • Journal of Environmental Science International
    • /
    • v.18 no.3
    • /
    • pp.255-261
    • /
    • 2009
  • We need water equivalent unit data of snowfall for the purpose of forecast and hydrology related research area. This study developed new method of automatic recording snowfall as weight unit. The instrument designed for measuring weight of snowfall by stain-gauge loadcell. Field test of instrument carried out at Daegwallyeong Obs. Station from 22 Jan. to 22 Feb. 2007. During observation period there is 15.3 cm snow depth and 16.0 mm of accumulated water equivalent depth at Daegwallyeong Obs. Station on 13 to 14 Feb. 2007. But the instrument of this study recorded 22.1 mm of water equivalent depth. It is not easy to explain difference between Daegwallyeong and this study. Because this study is only one case of comparison of snow measurement and there is very little amount of snow observation research. The density of snowfall calculated from 0.09 to $0.15g/cm^3$ from the observation data of 13 to 14 Feb. 2007. There is high relation between radar echo and snowfall amount measured by weight unit. It can supports forecast of snowfall and development of numerical model for forecast.