• 제목/요약/키워드: field calculation

검색결과 1,796건 처리시간 0.032초

새로운 초고압 송전선로 친환경설계프로그램 TLCALC (A New Environmentally Friendly Design Program TLCALC for High Voltage AC Transmission Lines)

  • 양광호;명성호;길경석;황기현;이동일;주문노
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권4호
    • /
    • pp.151-155
    • /
    • 2006
  • HVAC transmission lines must be designed to satisfy environmental regulations. Therefore it is necessary to pre-evaluate environmental problems for transmission line designer using prediction program. In this study, environmental design software, TLCALC(Transmission Line CALCulation) for transmission lines was developed as a comprehensive window program. It has 6 modules that are audible noise, radio noise, television noise, magnetic field, electric field and conductor surface gradient. TLCALC solved a few problems in use of the existing foreign tools and took several advantages as follows; (1) It is a common tool that solves calculating limitations of foreign formulas, (2) It has wide application ranges and enhances accuracy of prediction. (3) It can be applied to almost transmission line configurations in Korea. (4) Experienced designers can get the results of calculation within about 15 minutes. Because the use of TLCALC is easy and practical, this program will be usefully applied to the environmental friendly design and construction of transmission lines. In the future, it is expected that public complaints and social environmental cost will be reduced by the use of TLCALC.

A new method solving the temperature field of concrete around cooling pipes

  • Zhu, Zhenyang;Qiang, Sheng;Chen, Weimin
    • Computers and Concrete
    • /
    • 제11권5호
    • /
    • pp.441-462
    • /
    • 2013
  • When using the conventional finite element method, a great number of grid nodes are necessary to describe the large and uneven temperature gradients in the concrete around cooling pipes when calculating the temperature field of mass concrete with cooling pipes. In this paper, the temperature gradient properties of the concrete around a pipe were studied. A new calculation method was developed based on these properties and an explicit iterative algorithm. With a small number of grid nodes, both the temperature distribution along the cooling pipe and the temperature field of the concrete around the water pipe can be correctly calculated with this new method. In conventional computing models, the cooling pipes are regarded as the third boundary condition when solving a model of concrete with plastic pipes, which is an approximate way. At the same time, the corresponding parameters have to be got by expensive experiments and inversion. But in the proposed method, the boundary condition is described strictly, and thus is more reliable and economical. And numerical examples were used to illustrate that this method is accurate, efficient and applicable to the actual engineering.

기존 교각주변의 국부세굴 방지공법에 관한 연구 (The study of method local scour protection to the existing piers bridge)

  • 박상길;장태래;박병열
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.598-602
    • /
    • 2006
  • Local scour is associate with particular local types of vortex around bridge piers. This paper is method of protection local scour for the existing Busan City subway 3 Line bridge piers and Gupo large bridge piers. In order to take design of protection of local scour this bridge piers, We calculate the local scour hole of depth , scour width, riprap construction , filter construction by formulas. We had experimental hydraulic model test for this bridge piers in order to take proof for the calculation of local scour. We knew that the vortex intensifies the local flow velocities and acts to erode sediment from the scour hole and transport it downstream. As the result of hydraulic model test, we could suggest three types method of protection local scour this bridges. We knew that FHWA HEC-18(Richardson et al. 2001: Modified CSU) Formula is useful to checking calculation as application of field. One is pier protection using the sheet piles and riprap, the others are pier protection using the riprap with filter and to make renew Wall-caisson. The best method of protection for the existing Busan City subway 3 Line bridge piers and Gupo large bridge piers is pier protection using the sheet piles and riprap.

  • PDF

AT급전계통에서 실제 운행 중인 전기기관차 부하를 이용한 고장점 표정 알고리즘 보정계수 산출 방법 (Calculation Method of Modification Factors for Fault Location Algorithm Using Boosting Current of Operating Electric Train in AT Feeding System)

  • 김철환;김성렬;권성일;조규정;김철환;송인근
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.504-510
    • /
    • 2016
  • In general, a fault locator is installed in Sub-Station of AT(Auto-transformer) feeding system to estimate the fault location and to protect the Korean AT feeding system. Since the line impedance characteristic is different to normal 3-phase transmission line, we need particular modification factors, which can be calculated using fault location recording data, to estimate the accurate fault location. Up to recently, forcible ground test has been used to calculate the modification factors of the fault locator. However, large amount of current is occurred when the forcible ground test is performed, and this current affects to adjacent equipments. Therefore, we proposed a novel calculation method of modification factors, arbitrary trip test, using boosting current of the operating electric train. Through several field test, we confirmed that modification factors for fault locator can be easily calculated by using proposed method. Moreover, we verified the accuracy and stability of the proposed calculation method.

Numerical simulation of propeller exciting force induced by milling-shape ice

  • Wang, C.;Li, X.;Chang, X.;Xiong, W.P.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제11권1호
    • /
    • pp.294-306
    • /
    • 2019
  • On the basis of the Computational Fluid Dynamics technique (CFD) combined with the overlap grid method, this paper establishes a numerical simulation method to study the problem of ice-propeller interaction in viscous flow and carries out a simulation forecast of the hydrodynamic performance of an ice-class propeller and flow characteristics when in the proximity of milling-shape ice (i.e., an ice block with a groove cut by a high-speed revolving propeller). We use a trimmed mesh in the entire calculation domain and use the overlap grid method to transfer information between the domains of propeller rotation calculation and ice-surface computing. The grid is refined in the narrow gap between the ice and propeller to ensure the accuracy of the flow field. Comparison with the results of the experiment reveals that the error of the hydrodynamic performance is within 5%. This confirms the feasibility of the calculation method. In this paper, we calculate the exciting force of the propeller, analyze the time domain of the exciting force, and obtain the curve of the frequency domain using a Fourier transform of the time-domain curve of the exciting force. The existence of milling-shape ice before the propeller can greatly disturb the wake flow field. Unlike in open water, the propeller bearing capacity shows a downward trend in three stages, and fluctuating pressure is more disordered near the ice.

송전선로 주변의 3차원 자기장 및 인체 유도 와전류 계산 (ELF 3D Magnetic Field and Eddy Current Calculation of Human Body Around Transmission Lines)

  • 명성호;이동일;신구용;한인수;박종근
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권10호
    • /
    • pp.485-491
    • /
    • 2002
  • Since Wertheimer and Leeper reported possible adverse health effects of magnetic field in 1979, worldwide researches on this issue have been conducted. More recently, the U.S. Congress instructed the NIEHS (National Institute of Environmental Health Sciences), NIH (National Institute of Health) and DOE (Department of Energy) to direct and manage EMF RAPID (Electric and Magnetic Fields Research and Public Information Dissemination) program aimed at providing scientific evidence to clarify the potential for health risks from exposure to extremely low frequency electric and magnetic fields(ELF-EMF). Although they concluded that the scientific evidence suggesting adverse health risks of ELF-EMF is weak, the exposure to ELF-EMF cannot be recognized as entirely safe. Therefore, the purpose of this article is to describe magnetic field 3-D calculation and to evluate eddy current of human body compare to international guide line recognized one of the basic problems. In open boundary problem, Magnetic field using FEM is not advantageous in the point of the division of area and the proposition of the fictitious boundary. Therefore, we induced the analytic equation of magnetic field calculations so but the finite line segment based on Biot-Savarts law Also, Eddy currents induced due to ELF-EMF magnetic field are computed. To calculate induced currents, impedance method is used in this paper, An example model of human head with resolution of 1.27cm is used. In this paper, We evaluate the magnetic field and eddy current of human head around 765 kV transmission lines compare to international guide line.

태풍 ‘매미’ 내습시 관측자료를 이용한 울산 해역의 파고 분포 산출 (Calculation of the Wave Height Distribution in the Vicinity of Ulsan waters using the Observed Date of Typhoon Maemi)

  • 김강민;김종훈;유하상;정원무
    • 한국항해항만학회지
    • /
    • 제31권6호
    • /
    • pp.479-484
    • /
    • 2007
  • 항만 및 해안구조물의 설계시 사용되는 천해역에서의 파랑장 계산은 내륙 관측소의 바람자료를 이용하거나 심해파 추산모형에 의하여 추출된 심해파제원을 사용하는 것이 일반적이다. 그러나 전자의 경우는 관측소가 대부분 내륙에 위치하여 파랑발달을 모의하기 위한 정확한 바람자료를 얻기란 매우 어렵다. 또한, 후자의 경우는 아주 넓은 영역에서 큰 격자크기로 계산이 이루어지기 때문에 연안 및 천해역 지형을 상세히 재현하지 못하므로 임의의 정점에 대한 정확한 정보를 파악하기도 어렵다. 따라서, 본 연구에서는 우리나라 동남부 해역의 태풍 ‘매미’ 내습시의 파랑 관측자료를 사용하여 천해역에서의 파랑장 계산을 수행하였다. 또한, 계산된 파랑장의 정확도를 확인하기 위하여 울산해역 인근의 파고 및 파향 관측결과를 비교 검토하였다. 울산해역에 대한 파고분포 산출결과, 관측정점에서 파고는 ${\pm}1.3%$의 차이를 보여 기존의 방법 보다 높은 정확도를 보이는 것으로 나타났다.

복잡(複雜)한 탄층구조(炭層構造)에서의 이논전위곡선(理論電位曲線)의 계산(計算) (Theoretical Potential Calculation of Coal Seam in Various Structures)

  • 김웅수;서백수
    • 산업기술연구
    • /
    • 제1권
    • /
    • pp.27-33
    • /
    • 1981
  • Due to intense tectonic activities and volcanic movements, coal mines exploration have been conflicted with problems so far. In this paper, computer calculation was specially applied for various model structures of inclined, anticlined and synclined coal beds. Of all these structures, the gradient of equipotential curves showed great as the dip of coal beds increases. Especially at synclined structure, the concaves appeared sharply in both sides of equipotential curves as the dip of coal beds increases. By above results, interpretation of coal exploration can be done by comparing field data one another.

  • PDF

공정능력지수 산정에 있어 고려사항 (Issues on the Calculation of the Process Capability Index)

  • 이도경
    • 산업경영시스템학회지
    • /
    • 제37권1호
    • /
    • pp.127-132
    • /
    • 2014
  • This study is concerned with process capability index in single process. We enumerated issues on the calculation of process capability index and described the effects of these issues. We explained the development process and the reason of the representative existing process capability indices. We investigated whether the indices agree with the concept of process capability and drew the problems from those results. In addition, we proposed alternative and direction to seize the process capability necessary to the field.

A Green's-Matrix Approach to Chemisorption

  • Jang, Yun-Hee;Kim, Ho-Jing
    • Bulletin of the Korean Chemical Society
    • /
    • 제14권2호
    • /
    • pp.238-243
    • /
    • 1993
  • A self-consistent-field Green's matrix method for the calculation of electronic properties of chemisorbed system is devised and applied to the methanol on copper(110) surface. The method is based on CNDO Hartree-Fock approximation. Contour integration in the complex energy plane is used for an efficient calculation of the charge-density bond-order matrix. The information on each fragment prior to chemisorption is efficiently used and a small number of iterations are needed to reach the self-consistency. The changes of density of states and other quantities of methanol due to chemisorption are consistent with reported experimental results.