• Title/Summary/Keyword: field attenuation

Search Result 260, Processing Time 0.025 seconds

Rayleigh waves in anisotropic magnetothermoelastic medium

  • Kumar, Rajneesh;Sharma, Nidhi;Lata, Parveen;Abo-Dahab, S.M.
    • Coupled systems mechanics
    • /
    • v.6 no.3
    • /
    • pp.317-333
    • /
    • 2017
  • The present paper is concerned with the investigation of Rayleigh waves in a homogeneous transversely isotropic magnetothermoelastic medium with two temperature, in the presence of Hall current and rotation. The formulation is applied to the thermoelasticity theories developed by Green-Naghdi theories of Type-II and Type-III. Secular equations are derived mathematically at the stress free and thermally insulated boundaries. The values of Determinant of secular equations, phase velocity and Attenuation coefficient with respect to wave number are computed numerically. Cobalt material has been chosen for transversely isotropic medium and magnesium material is chosen for isotropic solid. The effects of rotation, magnetic field and phase velocity on the resulting quantities and on particular case of isotropic solid are depicted graphically. Some special cases are also deduced from the present investigation.

Rayleigh′s Acoustical Research on the Fog Signal

  • Ku, Ja Hyon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.3E
    • /
    • pp.98-102
    • /
    • 2004
  • In 1896, Rayleigh was appointed as Scientific Advisor of the Trinity House. Rayleigh applied his knowledge of sound to developing effective fog signals during his IS-year tenure at the maritime organization. Rayleigh's expertise on acoustics met an appropriate field for its application during his improvement of the fog signal for the institution. Rayleigh's activities at the Trinity House were motivated by his desire to make contribution to the public. During his research on the fog signal, Rayleigh effectively employed his expertise acquired through his mathematical and experimental research on sound and vibration since the 1860s. Rayleigh developed effective horns for emitting fog signals and proposed various ways of overcoming the weaknesses of sound signals available at that time. While attempting to solve the problem of the attenuation of sound signals disseminating through the air, Rayleigh put foundations of atmospheric acoustics by developing new scientific theories about it.

Vibration Attenuation of a Drum-Typed Washing Machine Using Magneto-Rheological Dampers (MR 댐퍼를 사용한 드럼세탁기의 진동완화)

  • Cha, Sang-Tae;Baek, Woon-Kyung
    • Journal of Power System Engineering
    • /
    • v.17 no.2
    • /
    • pp.63-69
    • /
    • 2013
  • Most washing machines are now produced as a drum-type, where a washing drum mounted on a suspension system with springs and dampers, to minimize the transmittance of the vibration from the drum to the frame. A low-cost MR damper, using magneto-rheological fluids, can produce variable damping forces by changing the current values in the magnetic coil. Experimental results show the comparison of the vibration attenuation performances between two different dampers. One test set-up uses a passive damper and another one uses a MR fluid damper. The test results showed that the vibration amplitude of the washing machine with the MR damper is much smaller than the case with the passive damper.

A Study on the Sound Resonating Barrier (음향공명 방음벽 연구)

  • Lee, Jun-Shin;Kim, Tae-Ryong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.6
    • /
    • pp.413-419
    • /
    • 2002
  • Noise barriers are widely used to reduce the sound level propagating from highways, railways or factories to residential areas. The reduced noise level at a receiver point is then determined by the diffracted waves around the edge of the barrier as well as by the transmitted waves through the barrier. 1'or proper usage, many studies either theoretical or experimental have been made with the objective of precisely Predicting the acoustic field and improving the noise attenuating properties of barriers. In this study. a simple scattering model. a line acoustic source scattered by an infinite cylinder, is introduced to simply Investigate the sound attenuation efficiency of a sound-resonating barrier. From this model study, it is observed that the sound-resonating harrier can be used as a good sound-shielding element especially for the pure-tone noise generated from the transformer. Large sound-attenuation is achieved by applying the sound-resonating barrier to the large transformers in a substation.

Signal Attenuation in Mobile Communication by Many Different Types of Obstacles (이동통신시 여러 형태의 장애물로 인한 신호감쇠)

  • 이찬주;홍의석
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.4
    • /
    • pp.7-13
    • /
    • 1992
  • Diffraction loss occurs when the propagation path is obstructed by mountains and hills between a base station antenna and a moving vehicle antenna in mobile-radio communication. In this paper an approximate mathematical model using Fresnel-Kirchhoff diffraction theory is considered to predict propogation attenuation by natural obstacles with lateral profiles having general shapes. Field tests are conducted using helical and crossed drooping dipole antenna at 820 MHz. The theoretical analysis used in estimating the effects of hills agrees reasonably with experimental data. The results seem to be useful for estimating the level of received power, the minimum allowable input power, the optimum site of base station and consequently, planning terrestrial microwave links.

  • PDF

The Characteristic of Data Transmission for Power Line Communication using an AC Arrester for Electric Railway (전철 피뢰기를 이용한 전력선 통신 데이터 전송 특성)

  • Kim, Jae-Moon;Ahn, Seung-Ho;Kim, Yang-Su;Kim, Chul-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.497-502
    • /
    • 2012
  • Power line communication(PLC) is a kind of communication technology, was made use of controling a frequency narrow band, but as the PLC technology developing, in the near future get to the commercial step that is broadband PLC upto 30 MHz. This paper deals with the PLC of electric railway using capacitive signal coupler. An AC arrester for catenary is used as a capacitive signal coupler, has the characteristic of capacitor. As a result of field test, a messenger wire used PLC contain much of conducted noise about overall frequency band and also signal attenuation rate increased with increasing frequency between two points. and the communication speed of PLC used messenger wire is 793kbps at a distance of 40m. Experimental results show the possibility of PLC using a messenger wire and an AC arrester for catenary at electric railway.

Micromachined Low-Loss Low-Dispersion Elevated CPW for High-Speed Interconnects

  • S. H. Jeong;Lee, S. N.;Lee, S. G.;J. G. Yook;Kim, Y. J.;Park, H. K.
    • Journal of electromagnetic engineering and science
    • /
    • v.2 no.2
    • /
    • pp.59-64
    • /
    • 2002
  • In this paper, 10$\mu$ m-elevated MEMS CPWs on various substrates are presented. Effective dielectric constants of elevated CPW(ECPW) on polyimide-loaded silicon or alumina substrate are examined and characteristic impedances are also computed versus elevation height. Dispersive property of ECPW and its electromagnetic field distributions are studied through 3-D FDTD algorithm for optimum design. Attenuation of ECPW is measured with TRL calibration procedure and revealed about 3.2 43 lower than that of conventional CPW on the same low-resistivity silicon at 40 CHz. ECPW on polyimide-loaded silicon with overlapped configuration reveals 0.2 dB/mm. Especially, alumina substrate imposes better attenuation than silicon.

A Study on the Sound Resonating Barrier (음향공명 방음벽 연구)

  • 이준신;김태룡;손석만;박동수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.659-664
    • /
    • 2001
  • Noise barriers are widely used to reduce the sound level propagating from highways, railways or factories to residential areas. The reduced noise level at a receiver point is then determined by the diffracted waves around the edge of the barrier as well as by the transmitted waves through the barrier. For proper usage, many studies either theoretical or experimental have been made with the objective of precisely predicting the acoustic field and improving the noise attenuating properties of barriers. In this study, a simple scattering model, a line acoustic source scattered by an infinite cylinder, is introduced to simply investigate the sound attenuation efficiency of a sound-resonating barrier. From this model study, it is observed that the sound-resonating barrier can be used as a good sound-shielding element especially for the pure-tone noise generated from the transformer. Large sound-attenuation is achieved by applying the sound-resonating barrier to the large transformers in a substation.

  • PDF

Development of Cabin Noise Prediction Program Induced by HVAC System (공조시스템 유기 격실 소음 예측 프로그램 개발)

  • Kim, Byung-Hee;Kwon, Jong-Hyun;Cho, Dae-Seung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.554-558
    • /
    • 2004
  • In this paper, we introduce noise prediction program of HVAC system to assist low-noisy design of ship's cabin. The developed program calculates sound power levels at HVAC components considering primary and secondary noise generated by fan and duct element, duct element noise attenuation, and duct break-in noise based on the authentic empirical method suggested by NEBB and acoustic power balancing method. Sound pressure level at cabin with or without ceiling system is evaluated by the diffuse-field theory considering diffuser and duct break-out sound powers. Moreover, the program provides intuitive pre- and post-processors using modem GUI functions to help efficient modeling and evaluation of cabin and HVAC component noise. To validate the accuracy and convenience of the program, noise prediction for a HVAC system is demonstrated.

  • PDF

IN-VIVO DOSE RECONSTRUCT10N USING A TRANSMISION FACTOR AND AN EFFECTIVE FIELD CONCEPT (팬텀투과계수와 유효조사면 개념을 이용한 종양선량 확인에 관한 연구)

  • Kim, You-Hyun;Yeo, In-Hwan;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.25 no.1
    • /
    • pp.63-71
    • /
    • 2002
  • The aim of this study Is to develop a simple and fast method which computes in-vivo doses from transmission doses measured doting patient treatment using an ionization chamber. Energy fluence and the dose that reach the chamber positioned behind the patient is modified by three factors: patient attenuation, inverse square attenuation. and scattering. We adopted a straightforward empirical approach using a phantom transmission factor (PTF) which accounts for the contribution from all three factors. It was done as follows. First of all, the phantom transmission factor was measured as a simple ratio of the chamber reading measured with and without a homogeneous phantom in the radiation beam according to various field sizes($r_p$), phantom to chamber distance($d_g$) and phantom thickness($T_p$). Secondly, we used the concept of effective field to the cases with inhomogeneous phantom (patients) and irregular fields. The effective field size is calculated by finding the field size that produces the same value of PTF to that for the irregular field and/or inhomogeneous phantom. The hypothesis is that the presence of inhomogeneity and irregular field can be accommodated to a certain extent by altering the field size. Thirdly, the center dose at the prescription depth can be computed using the new TMR($r_{p,eff}$) and Sp($r_{p,eff}$) from the effective field size. After that, when TMR(d, $r_{p,eff}$) and SP($r_{p,eff}$) are acquired. the tumor dose is as follows. $$D_{center}=D_t/PTF(d_g,\;T_p){\times}(\frac{SCD}{SAD})^2{\times}BSF(r_o){\times}S_p(r_{p,eff}){\times}TMR(d,\;r_{p,eff})$$ To make certain the accuracy of this method, we checked the accuracy for the following four cases; in cases of regular or irregular field size, inhomogeneous material included, any errors made and clinical situation. The errors were within 2.3% for regular field size, 3.0% irregular field size, 2.4% when inhomogeneous material was included in the phantom, 3.8% for 6 MV when the error was made purposely, 4.7% for 10 MV and 1.8% for the measurement of a patient in clinic. It is considered that this methode can make the quality control for dose at the time of radiation therapy because it is non-invasive that makes possible to measure the doses whenever a patient is given a therapy as well as eliminates the problem for entrance or exit dose measurement.

  • PDF