• Title/Summary/Keyword: feedback reduction

Search Result 287, Processing Time 0.022 seconds

Configuration assessment of MR dampers for structural control using performance-based passive control strategies

  • Wani, Zubair R.;Tantray, Manzoor A.;Iqbal, Javed;Farsangi, Ehsan Noroozinejad
    • Structural Monitoring and Maintenance
    • /
    • v.8 no.4
    • /
    • pp.329-344
    • /
    • 2021
  • The use of structural control devices to minimize structural response to seismic/dynamic excitations has attracted increased attention in recent years. The use of magnetorheological (MR) dampers as a control device have captured the attention of researchers in this field due to its flexibility, adaptability, easy control, and low power requirement compared to other control devices. However, little attention has been paid to the effect of configuration and number of dampers installed in a structure on responses reduction. This study assesses the control of a five-story structure using one and two MR dampers at different stories to determine the optimal damper positions and configurations based on performance indices. This paper also addresses the fail-safe current value to be applied to the MR damper at each floor in the event of feedback or control failure. The model is mathematically simulated in SIMULINK/MATLAB environment. Linear control strategies for current at 0 A, 0.5 A, 1 A, 1.5 A, 2 A, and 2.5 A are implemented for MR dampers, and the response of the structure to these control strategies for different configurations of dampers is compared with the uncontrolled structure. Based on the performance indices, it was concluded that the dampers should be positioned starting from the ground floor, then the 2nd floor followed by 1st and rest of the floors sequentially. The failsafe value of current for MR dampers located in lower floors (G+1) should be kept at a higher value compared to dampers at top floors for effective passive control of multi-story structures.

Apply evolved grey-prediction scheme to structural building dynamic analysis

  • Z.Y. Chen;Yahui Meng;Ruei-Yuan Wang;Timothy Chen
    • Structural Engineering and Mechanics
    • /
    • v.90 no.1
    • /
    • pp.19-26
    • /
    • 2024
  • In recent years, an increasing number of experimental studies have shown that the practical application of mature active control systems requires consideration of robustness criteria in the design process, including the reduction of tracking errors, operational resistance to external disturbances, and measurement noise, as well as robustness and stability. Good uncertainty prediction is thus proposed to solve problems caused by poor parameter selection and to remove the effects of dynamic coupling between degrees of freedom (DOF) in nonlinear systems. To overcome the stability problem, this study develops an advanced adaptive predictive fuzzy controller, which not only solves the programming problem of determining system stability but also uses the law of linear matrix inequality (LMI) to modify the fuzzy problem. The following parameters are used to manipulate the fuzzy controller of the robotic system to improve its control performance. The simulations for system uncertainty in the controller design emphasized the use of acceleration feedback for practical reasons. The simulation results also show that the proposed H∞ controller has excellent performance and reliability, and the effectiveness of the LMI-based method is also recognized. Therefore, this dynamic control method is suitable for seismic protection of civil buildings. The objectives of this document are access to adequate, safe, and affordable housing and basic services, promotion of inclusive and sustainable urbanization, implementation of sustainable disaster-resilient construction, sustainable planning, and sustainable management of human settlements. Simulation results of linear and non-linear structures demonstrate the ability of this method to identify structures and their changes due to damage. Therefore, with the continuous development of artificial intelligence and fuzzy theory, it seems that this goal will be achieved in the near future.

The Impact of Unit Pricing System on the Demand for Solid Waste Disposal, Food Waste Disposal, and Recyclables (종량제 가격이 생활폐기물, 음식물쓰레기, 재활용품 수거서비스 수요에 미치는 영향)

  • Hong, Seonghoon
    • Environmental and Resource Economics Review
    • /
    • v.24 no.4
    • /
    • pp.747-761
    • /
    • 2015
  • This paper investigates the impact of an increase in unit price of solid waste collection on demand for alternative solid waste disposal types. I control for other variables affecting the demand and employ both community and time fixed effects models in the estimation of each reduced-form demand functions. Estimation results show that an increase in unit price reduces the demand for garbage bag collection services of non-food solid wastes while it increases the demand for food wastes and source-separated recyclables. These results imply that reduction in the demand for non-food solid wastes collection is mainly achieved by increasing the amount of recyclables and food wastes collected. However, it appears that an increase in unit price increases the total amount of solid wastes generated. This suggests that price incentive effects are offset by the decrease in source-reduction efforts because of feedback effects resulting from the increase in recycling, food waste separation, and illegal disposal of wastes.

Study on the Management and Improvement Methods of Fire Safety Shared Tax (소방안전교부세의 운영 및 개선방안에 관한 연구)

  • Jang, Jung-Don;Lee, Jong-Ho
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.117-125
    • /
    • 2018
  • This paper examined the problems concerning recognition of business selection and operation, etc. and the presentation of the corresponding improvement measures. For this purpose, according to the results of a questionnaire survey on recognition of detailed business operation of the fire safety shared tax, satisfaction in business execution, financial operation measures for the subject of fire fighters, fire fighters have been shown to be indifferent to the detailed business field of fire safety shared tax, investment contents, etc. in the operation of fire safety shared tax. In terms of satisfaction after execution of the shared tax, reduction of the aging rates for firefighting equipment and improvement of dissemination rate was shown to be high with Fire Sergeant (M = 3.70) and a service duration of more than 16 years (M=3.64). To improve the measures of finance, there was considerable feedback saying that the reduction in state subsidy was inappropriate. In view of the diversification and development of the fire safety shared tax businesses being operated on a limited basis along with the overlap of most state subsidy businesses with safety field businesses, legal system improvement is needed for the stable securing of insufficient firefighting financial resources so that the full amount of shared tax can be invested in firefighting fields.

Arctic Climate Change for the Last Glacial Maximum Derived from PMIP2 Coupled Model Results (제2차 고기후 모델링 비교 프로그램 시뮬레이션 자료를 이용한 마지막 최대빙하기의 북극 기후변화 연구)

  • Kim, Seong-Joong;Woo, Eun-Jin
    • Journal of Climate Change Research
    • /
    • v.1 no.1
    • /
    • pp.31-50
    • /
    • 2010
  • The Arctic climate change for the Last Glacial Maximum(LGM) occurred at 21,000 years ago (21ka) was investigated using simulation results of atmosphere-ocean coupled models from the second phase of the Paleoclimate Modelling Intercomparison Program(PMIP2). In the analysis, we used seven models, the NCAR CCSM of USA, ECHAM3-MPIOM of German Max-Planxk Institute, HadCM3M2 of UK Met Office, IPSL-CM4 of France Laplace Institute, CNRM-CM3 of France Meteorological Institute, MIROC3.2 of Japan CCSR at University of Tokyo, and FGOALS of China Institute of Atmospheric Physics. All the seven models reproduces the Arctic climate features found in the present climate at 0ka(pre-industrial time) in a reasonable degree in comparison to observations. During the LGM, the atmospheric $CO_2$ concentration and other greenhouse gases were reduced, the ice sheets were expanded over North America and northern Europe, the sea level was lowered by about 120m, and orbital parameters were slightly different. These boundary conditions were implemented to simulated LGM climate. With the implemented LGM conditions, the biggest temperature reduction by more than $24^{\circ}C$ is found over North America and northern Europe owing to ice albedo feedback and the change in lapse rate by high elevation. Besides, the expansion of ice sheets leads to the marked temperature reduction by more then $10^{\circ}C$ over the Arctic Ocean. The temperature reduction in northern winter is larger than in summer around the Arctic and the annual mean temperature is reduced by about $14^{\circ}C$. Compared to low mid-latitudes, the temperature reduction is much larger in high northern altitudes in the LGM. This results mirror the larger warming around the Artic in recent century. We could draw some information for the future under global warming from the knowledge of the LGM.

Building an Efficient Supply Chain by reduction of lead time with a Focus on Korea Server Manufacturer (리드타임 감소에 의한 효율적 공급체인 구축 - 국내 서버 공급체인을 대상으로 -)

  • 신용석;김태현;문성암
    • Journal of Distribution Research
    • /
    • v.6 no.2
    • /
    • pp.1-17
    • /
    • 2002
  • The recent dot-com craze has been one of the main causes that accelerated the growth of internet-related companies in diversity as well as in size. Meanwhile, the domestic market of supplies and equipment for internet businesses has been dominated by major foreign companies. To regain their market positions, the domestic manufacturers had to find the way to build up their competitive advantages, such as meeting their customers needs and reducing overall costs. In this study, one domestic PC server manufacturer, which competes fiercely with foreign manufacturers for the top place, has been chosen as a model to evaluate its current supply chain and to find an area that can be improved for a better performance. System Dynamics is used throughout the study. The central concept to system dynamics is understanding how all the objects in a system interact with one another. It focuses on feedback and secondary effects to think through how a strategy might or might not work, depending on how organizational changes are received, and what kinds of consequences emerge. Then, computerized models were built for simulations, each with different conditions, and, finally, the results were evaluated based on some criteria which are considered to be important and meaningful. The inefficiency that exists in the supply chain was proved to be a thirty-day long purchasing order leadtime, and it was expected that more effective supply chain could be formed if the leadtme were reduced to 14 days or 7 days. The results of simulations showed that the overall expected costs in supply chain was the least with the purchasing leadtime being 7 days. The lower average number of parts held as inventory, along with the reduced lost sales, acted as the factor reducing the expected overall costs. Although there was a slight increase in the average number of final products held as inventory and the total ordering cost, the benefits from lower parts inventory and reduced lost sales were large enough to justify the overall cost reduction.

  • PDF

Cytosolic Phospholipase A2 Activity in Neutrophilic Oxidative Stress of Platelet-activating Factor-induced Acute Lung Injury (Platelet-activating Factor에 의한 급성폐손상에서 호중구성 산화성 스트레스에 관여하는 Cytosolic Phospholipase A2 활성도의 변화)

  • Kwon, Young Shik;Hyun, Dae Sung;Lee, Young Man
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.6
    • /
    • pp.497-506
    • /
    • 2007
  • Background: The present investigation was performed in rats and isolated human neutrophils in order to confirm the presumptive role of the positive feedback loop of cytosolic phospholipase $A_2$ ($cPLA_2$) activation by plateletactivating factor (PAF). Methods: The possible formation of the positive feedback loop of the $cPLA_2$ activation and neutrophilic respiratory burst was investigated in vivo and in vitro by measurement of the parameters denoting acute lung injury. In addition, morphological examinations and electron microscopic cytochemistry were performed for the detection of free radicals in the lung. Results: Five hours after intratracheal instillation of PAF ($5{\mu}g/rat$), the lung leak index, lung myeloperoxidase (MPO) activity, the number of neutrophils and the concentration of cytokine-induced neutrophil chemoattractant (CINC) in bronchoalveolar lavage fluid were increased by PAF as compared with those of control rats. The NBT assay and cytochrome-c reduction assay revealed an increased neutrophilic respiratory burst in isolated human neutrophils following exposure to PAF. Lung and neutrophilic $cPLA_2$ activity were increased following PAF exposure and exposure to hydrogen peroxide increased $cPLA_2$ activity in the lung. Histologically, inflammatory findings of the lung were observed after PAF treatment. Remarkably, as determined by $CeCl_3$ cytochemical electron microscopy, increased production of hydrogen peroxide was identified in the lung after PAF treatment. Conclusion: PAF mediates acute oxidative lung injury by the activation of $cPLA_2$, which may provoke the generation of free radicals in neutrophils.

Porewater Pressure Buildup Mode Induced in Near-field of Open-ended Pipe Pile during Earthquake and Sequake (지진과 해진시 개단강관말뚝 주변에 유발된 간극수압의 발생 양상)

  • 최용규
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.23-30
    • /
    • 1998
  • During an earthquake, there are three components of excitation : horizontal excitation of the ground, vertical excitation of the pile due to superstructure feedback produced by vertical excitation of the ground, and the seawater excitation by the vertical ground shaking, that is, "the seaquake." These excitations could have effects on the pore pressure buildup mode induced in the near-field of open-ended pile and the soil plugs in open-ended pipe piles installed at offshore sites. While the ground and pile excitation could be modeled by exciting the soil and pile with simulated motions, seaquake excitation induced by the vertical ground shaking can be modeled by pulsing the water pressure at the seabed. The objectives of this study were to observe buildup trend for the porewater pressures developed in near-field of open-ended pipe pile installed in the calibration chamber during the simulated earthquake and seaquake and, also to confirm the cause for reduction of soil plugging according to pore pressure buildup. During the simulated horizontal seismic motion, there was no upward flow through soil plug because the similar magnitude of excess porewater pressure were occurred at the top and under the toe of soil plug. During the horizontal seismic motion, relatively higher hydraulic gradients caused upward flow in the soil plug and then the degradation of plugging resistance was about 20%. During seaquake, in the case of the open-ended pile installed in a deep sea with more than 220m of water depth, soil plug failed completely because of high upward hydraulic gradients through soil plug.soil plug.

  • PDF

Analysis on the Noise Factors of Static Induction Photo-Transistor (SIPT) (1) - The SIPT's Equivalent Circuits for the Analysis on the Noise Factors - (정전유도(靜電誘導) 포토 트랜지스터의 잡음(雜音) 원인(原因) 분석(分析) (1) - 잡음(雜音) 원인(原因) 분석(分析)을 위한 SIPT 등가회로(等價回路) -)

  • Kim, Jong-Hwa
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.4
    • /
    • pp.29-40
    • /
    • 1995
  • In this paper, the noise equivalent cicuits that is necessary to the formulation of D.C. and noise characteristics, residual component and input capacitance so as to analyze on the noise factors of the SIT is proposed. The simplest noise equivalent circuit is the model representing the mechanism of the SIT and the measured values in this model were found as small as the values of the shot-noise. In the source resistance inserted equivalent circuit is conformed that the shot-noise will be reduced by the negative-feedback effect of the source resistance. In oder to analyze the correct noise reduction factor, I proposed the equivalent circuit which the formulas of the source and drain resistance was induced. In the experiment which affirm the equivalent circuits, the influence of the signal source resistance and output load resistance on the residual component is small and the residual component can be expressed by the equivalent input noise resistance. Moreover, the input capacitance is 13.6 pF when the load resistance is $0{\Omega}$ and the capacitance which does not concern with the SIT operation directly, that is, gate wire etc, is 10pF or so.

  • PDF

Improvement of Power Transfer Efficiency Using Negative Impedance Converter for Wireless Power Transfer System with Magnetic Resonant Coupling (부성 임피던스 변환기를 적용한 자기공명 방식 무선전력전송 시스템의 효율 개선)

  • Yoon, Se-Hwa;Kim, Tae-Hyung;Park, Jin-Kwan;Kim, Seong-Tae;Yun, Gi-Ho;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.12
    • /
    • pp.933-940
    • /
    • 2017
  • A wireless power transfer system with a negative impedance converter(NIC) was designed and tested. The system was investigated to identify the effects of ferrites and conductors. To improve the power transfer efficiency(PTE), the Q-factor of the transmitter was enhanced by the negative resistance generated by the NIC. The NIC was composed of an Op-Amp and resistors. The negative resistance was obtained with respect to a resistor connected in a feedback loop. The dimension of the Tx coil was $250mm{\times}250mm{\times}0.8mm$. The impedance and Q-factor were $31+j1874{\Omega}$ and 60, respectively. The negative resistance was selected to be $30{\Omega}$, and the Q-factor was increased to 900 by reduction of the transmitter resistance, which was about 15 times higher than that of a conventional transmitter. The measured PTE was greatly improved in comparison to that of a conventional system. These results demonstrate that the PTE is enhanced by using the NIC.