• Title/Summary/Keyword: fault types

Search Result 442, Processing Time 0.027 seconds

Fault Location for Incomplete-Journey Double-Circuit Transmission Lines on Same Tower Based on Identification of Fault Branch

  • Wang, Shoupeng;Zhao, Dongmei;Shang, Liqun
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1754-1763
    • /
    • 2017
  • This paper analyses the characteristics of incomplete-journey double-circuit transmission lines on the same tower formed by single-circuit lines and double-circuit lines, and then presents a fault location algorithm based on identification of fault branch. With the relationship between the three-phase system and the double-circuit line system, a phase-mode transformation matrix for double-circuit lines can be derived. Based on the derived matrix, the double-circuit lines with faults can be decoupled, and then the fault location for an incomplete-journey double-circuit line is achieved by using modal components in the mode domain. The algorithm is divided into two steps. Firstly, the fault branch is identified by comparing the relationships of voltage amplitudes at the bonding point. Then the fault location, on the basis of the identification result, is calculated by using a two-terminal method, and only the fault distance of the actual fault branch can be obtained. There is no limit on synchronization of each terminal sampling data. The results of ATP-EMTP simulation show that the proposed algorithm can be applied within the entire line and can accurately locate faults in different fault types, fault resistances, and fault distances.

A Process Fault Detection Filter Design by Fault Vector Modelling Approach and an Application (고장벡터 모델링에 위한 프로세스 고장 검출필터의 설계 및 응용)

  • 이기상;배상욱
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.6
    • /
    • pp.430-436
    • /
    • 1987
  • A Detection filter that can be used for the Detection and Isolation of process faults is proposed by the use of fault vector modelling, and is applied to DC Motor fault detection. The proposed detection filter is a new one in a view point that its outputs are the estimates of fault variables(or linear combination of them) while all the existing filters estimate the state of process. By this properties, the process fault detection systems with this filter can be constructed in very simple structure. Besides the simplicity of structure and design procedure, the filter has an useful feature that various types of fault can be estimated via the filter by choosing appropriate fault models.

  • PDF

Fault tolerant architecture for Module-based personal robot (모듈기반 퍼스널 로봇을 위한 Fault Tolerant 구조)

  • Baek, Bum-Hyun;Jee, Dong-Jun;Park, Chan-Jung;Han, Ki-Sung;Lee, Sun-Young;Kim, Kyeong-Tae;Hong, Sung-Won;Park, Hong-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.297-299
    • /
    • 2006
  • Many distributed applications is developed in various environment such as operating system, software platform. So, they exhibit different types of system behavior, status, during the course of their operation. Each such behavior may have different functional and non-functional requirements. Therefore, many distributed application need to fault-tolerance solution. Personal robot provide various service or application. Because personal robot has many application or service, it need to fault-tolerance architecture. A flexible architecture is required to provide dependability. In this paper, it is suggested a fault-tolerant architecture for module-based personal robot with module fault-tolerance, service fault-tolerance.

  • PDF

Fault Line Detection Methodology for Four Parallel Lines on the Same Tower

  • Li, Botong;Li, Yongli;Yao, Chuang
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1217-1228
    • /
    • 2014
  • A method for faulted line detection of four parallel lines on the same tower is presented, based on four-summing and double-differential sequences of one terminal current. Four-summing and double-differential sequences of fault current can be calculated using a certain transformation matrix for parameter decoupling of four parallel transmission lines. According to fault boundary conditions, the amplitude and phase characteristics of four-summing and double-differential sequences of fault current is studied under conditions of different types of fault. Through the analysis of the relationship of terminal current and fault current, a novel methodology for fault line detection of four parallel transmission line on the same tower is put forward, which can pick out the fault lines no matter the fault occurs in single line or cross double lines. Simulation results validate that the methodology is correct and reliable under conditions of different load currents, transient resistances and fault locations.

A Fault Diagnosis Method in Cascaded H-bridge Multilevel Inverter Using Output Current Analysis

  • Lee, June-Hee;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2278-2288
    • /
    • 2017
  • Multilevel converter topologies are widely used in many applications. The cascaded H-bridge multilevel inverter (CHBMI), which is one of many multilevel converter topologies, has been introduced as a useful topology in high and medium power. However, it has a drawback to require a lot of switches. Therefore, the reliability of CHBMI is important factor for analyzing the performance. This paper presents a simple switch fault diagnosis method for single-phase CHBMI. There are two types of switch faults: open-fault and short-fault. In the open-fault, the body diode of faulty switch provides a freewheeling current path. However, when the short-fault occurs, the distortion of output current is different from that of the open-fault because it has an unavailable freewheeling current flow path due to a disconnection of fuse. The fault diagnosis method is based on the zero current time analysis according to zero-voltage switching states. Using the proposed method, it is possible to detect the location of faulty switch accurately. The PSIM simulation and experimental results show the effectiveness of proposed switch fault diagnosis method.

Algorithm for Fault Location Estimation on Transmission Lines using Second-order Difference of a Positive Sequence Current Phasor

  • Yeo, Sang-Min;Jang, Won-Hyeok;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.499-506
    • /
    • 2013
  • The accurate estimation of a fault location is desired in distance protection schemes for transmission lines in order to selectively deactivate a faulted line. However, a typical method to estimate a fault location by calculating impedances with voltages and currents at relaying points may have errors due to various factors such as the mutual impedances of lines, fault impedances, or effects of parallel circuits. The proposed algorithm in this paper begins by extracting the fundamental phasor of the positive sequence currents from the three phase currents. The second-order difference of the phasor is then calculated based on the fundamental phasor of positive sequence currents. The traveling times of the waves generated by a fault are derived from the second-order difference of the phasor. Finally, the distance from the relaying point to the fault is estimated using the traveling times. To analyze the performance of the algorithm, a power system with EHV(Extra High Voltage) untransposed double-circuit transmission lines is modeled and simulated under various fault conditions, such as several fault types, fault locations, and fault inception angles. The results of the simulations show that the proposed algorithm has the capability to estimate the fault locations with high speed and accuracy.

Fault Current Characteristics of a High-$T_c$ Model Power Cable (고온 초전도모델전력케이블의 사고전류 특성)

  • Kim, Chang-Wan;Jung, Jae-Hoon;Ryu, Kyung-Woo;Cha, Guee-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.684-686
    • /
    • 2001
  • A Bi-2223 tape has been developed for power applications such as power cables or transformers working at liquid nitrogen temperature. For such applications it is required to understand fault current characteristics of the Bi-2223 tape. In this paper, we report fault current characteristics using two types of samples, straight sample and pancake coil sample. It was found that the fault current characteristics of the Bi-2223 tape are depend on electrical insulations and fault durations strongly. Also it was shown that the fault current characteristics in the insulated straight sample are similar to those in the pancake sample with a conductor insulation. Finally, it was shown that the pancake sample with a layer insulation has better characteristics than that with a conductor insulation for fault currents.

  • PDF

Balanced and Unbalanced Fault Analysis of Synchronous Generator (동기 발전기의 평형 및 불평형 고장해석)

  • Park, Cheol-Won;An, Jun-Yeong;Lee, Jong-Su;Lee, Sang-Seong;Sin, Myeong-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.402-404
    • /
    • 2006
  • In this paper, we simulated transient-state under fault in stator windings of synchronous generator. The fault types are line to ground fault, line to line short fault, and three phase short fault. For fault analysis of generator system, the voltage equation of a synchronous machine using the two-axis theory was used. It can be used to analyze important features of faults and to develop enhanced protection methods.

  • PDF

Preliminary Structural Segmentation of the Yangsan Fault (양산단층의 구조적 분절화 기초연구)

  • 장천중
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.49-56
    • /
    • 1997
  • Most large strike-slip faults do not rupture their entire length during single faulting but generally break in segments which are different in location and time of faulting. Studies related to the development of the Yangsan fault have been reported based on partial results from characteristics of geolgocial distribution, geophysical prospecting and paleostress analyses. This paper shows, based on preliminary results, that the Yangsan fault could be divided into four structural areas along entire length. These areas are different in geological distribution, bedding attitude measured from sedimentary rocks, strike of main fault, geometry of small faults, termination types of fault tips, cyclic variation of fault zone width, and arrangement of paleostress. Therefore, the Yangsan fault could be divided into at least four segments.

  • PDF

FPGA-based ARX-Laguerre PIO fault diagnosis in robot manipulator

  • Piltan, Farzin;Kim, Jong-Myon
    • Advances in robotics research
    • /
    • v.2 no.1
    • /
    • pp.99-112
    • /
    • 2018
  • The main contribution of this work is the design of a field programmable gate array (FPGA) based ARX-Laguerre proportional-integral observation (PIO) system for fault detection and identification (FDI) in a multi-input, multi-output (MIMO) nonlinear uncertain dynamical robot manipulators. An ARX-Laguerre method was used in this study to dynamic modeling the robot manipulator in the presence of uncertainty and disturbance. To address the challenges of robustness, fault detection, isolation, and estimation the proposed FPGA-based PI observer was applied to the ARX-Laguerre robot model. The effectiveness and accuracy of FPGA based ARX-Laguerre PIO was tested by first three degrees of the freedom PUMA robot manipulator, yielding 6.3%, 10.73%, and 4.23%, average performance improvement for three types of faults (e.g., actuator fault, sensor faults, and composite fault), respectively.