• Title/Summary/Keyword: fault rate

Search Result 469, Processing Time 0.026 seconds

Fault Diagnosis System for Traction Motor in Electric Multiple Unit (전동차 견인전동기 고장진단시스템)

  • Park, Hyun-June;Jang, Dong-Uk;Lee, Gil-Hun;Choi, Jong-Sun;Kim, Jung-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.518-521
    • /
    • 2003
  • A new measurement system was developed by fault diagnosis system for traction motor using current signal analysis. The motor current signature analysis method is used for traction motor fault diagnosis. The diagnosis system program is constructed by artificial neural networks algorithm, those results from the program are used to train neural networks. The trained neural networks have the ability to compute adaptive results for non-trained inputs, and to calculate very fast due to original parallel structure of neural networks with high accuracy within destined tolerance. This system suggested that available test for checking, the probable extent of aging, and the rate of which aging is taking place.

  • PDF

Practical Swarm Optimization based Fault-Tolerance Algorithm for the Internet of Things

  • Luo, Shiliang;Cheng, Lianglun;Ren, Bin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.4
    • /
    • pp.1178-1191
    • /
    • 2014
  • The fault-tolerance routing problem is one of the most important issues in the application of the Internet of Things, and has been attracting growing research interests. In order to maintain the communication paths from source sensors to the macronodes, we present a hybrid routing scheme and model, in which alternate paths are created once the previous routing is broken. Then, we propose an improved efficient and intelligent fault-tolerance algorithm (IEIFTA) to provide the fast routing recovery and reconstruct the network topology for path failure in the Internet of Things. In the IEIFTA, mutation direction of the particle is determined by multi-swarm evolution equation, and its diversity is improved by the immune mechanism, which can improve the ability of global search and improve the converging rate of the algorithm. The simulation results indicate that the IEIFTA-based fault-tolerance algorithm outperforms the EARQ algorithm and the SPSOA algorithm due to its ability of fast routing recovery mechanism and prolonging the lifetime of the Internet of Things.

Industrial Process Monitoring and Fault Diagnosis Based on Temporal Attention Augmented Deep Network

  • Mu, Ke;Luo, Lin;Wang, Qiao;Mao, Fushun
    • Journal of Information Processing Systems
    • /
    • v.17 no.2
    • /
    • pp.242-252
    • /
    • 2021
  • Following the intuition that the local information in time instances is hardly incorporated into the posterior sequence in long short-term memory (LSTM), this paper proposes an attention augmented mechanism for fault diagnosis of the complex chemical process data. Unlike conventional fault diagnosis and classification methods, an attention mechanism layer architecture is introduced to detect and focus on local temporal information. The augmented deep network results preserve each local instance's importance and contribution and allow the interpretable feature representation and classification simultaneously. The comprehensive comparative analyses demonstrate that the developed model has a high-quality fault classification rate of 95.49%, on average. The results are comparable to those obtained using various other techniques for the Tennessee Eastman benchmark process.

An Unavailability Evaluation for a Digital Reactor Protection System (디지털 원자로보호계통 불가용도 평가)

  • Lee, Dong-Yeong;Choe, Jong-Gyun;Kim, Ji-Yeong;Yu, Jun
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.81-83
    • /
    • 2005
  • The Reactor Protection System (RPS) is a very important system in a nuclear power plant because the system shuts down the reactor to maintain the reactor core integrity and the reactor coolant system pressure boundary if the plant conditions approach the specified safety limits. This paper describes the unavailability assessment of a digital reactor protection system using the fault tree analysis technique. The fault tree technique can be expressed in terms of combinations of the basic event failures. In this paper, a prediction method of the hardware failure rate is suggested for a digital reactor protection system. and applied to the reactor protection system being developed in Korea.

  • PDF

An Examination of Fault Exposure Rate of Switching Software of TDX Series from Empirical failure data (선험적 고장 데이터에 의한 TDX 계열 교환 소프트웨어의 결함 검출율 분석)

  • 이재기;신상권;홍성백
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.3
    • /
    • pp.27-35
    • /
    • 1999
  • 소프트웨어의 결함 검출율(FER : Fault Exposure Ratio)은 소프트웨어에 대한 시험의 효율성과 고장 당결함 발생율(per fault hazard rate)을 제어하는데 매우 중요한 요소이다. 특히 시험이 불규칙적으로 수행될 때 고장 발견은 더욱 어려워진다. 시험이 종료되는 단계에서 소프트웨어 결함 검출율이 낮은 경우는 시험의 유효성을 기대하기 어렵기 때문이다 일반적으로 결함 검출율(K)이 점차 높아지는 시험 종료 단계에서는 Random Test 보다는 강도 높은 실 시험이 수행되기 때문이다. 이런 가정하에 본 논문에서는 TDX 교환 소프트웨어의 결함 검출율을 추정하여 이를 기반으로 한 ATM 소프트웨어의 결함 검출율을 예측하고 또한 소프트웨어 신뢰도가 향상되어 가는 과정에 대해 논했다..

  • PDF

Study on the Reliability Analysis for Fault-Tolerant Dual Ethernet (고장극복 기능이 있는 이중망의 신뢰도 분석에 대한 연구)

  • Kim, Hyun-Sil
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.107-114
    • /
    • 2007
  • This paper describes the Petri Net(PN) model for reliability analysis of fault-tolerant dual Ethernet which Is applied in Naval Combat System. The network for Naval Combat System performs failure detection and auto path recovery by handling redundant path in case of temporary link failure. After studying the behavior of this kind of network, the reliability analysis model is proposed using stochastic Petri Net and continuous-time Markov chains. Finally, the numerical result is analyzed according to changing the failure rate and the recover rate of link.

Optimizing Checkpoint Intervals for Real-Time Multi-Tasks with Arbitrary Periods (임의 주기를 가지는 실시간 멀티 태스크를 위한 체크포인트 구간 최적화)

  • Kwak, Seong-Woo;Yang, Jung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.193-200
    • /
    • 2011
  • This paper presents an optimal checkpoint strategy for fault-tolerance in real-time systems. In our environment, multiple real-time tasks with arbitrary periods are scheduled in the system by Rate Monotonic (RM) algorithm, and checkpoints are inserted at a constant interval in each task while the width of interval is different with respect to the task. We propose a method to determine the optimal checkpoint interval for each task so that the probability of completing all the tasks is maximized. Whenever a fault occurs to a checkpoint interval of a task, the execution time of the task would be prolonged by rollback and re-execution of checkpoints. Our scheme includes the schedulability test to examine whether a task can be completed with an extended execution time. A numerical experiment is conducted to demonstrate the applicability of the proposed scheme.

The Alluvial Fan Surface Deformation of the Northern Part of the Ulsan(Bulguksa) Active Fault System in the Southeastern Korea

  • Yoon, Soon-Ock;Hwang, Sang-Il
    • The Korean Journal of Quaternary Research
    • /
    • v.18 no.2 s.23
    • /
    • pp.5-16
    • /
    • 2004
  • The geomorphic deformation of the alluvial fans by tectonic movement was investigated along the lineaments of the northem part of the Ulsan(Bulguksa) fault system. Based on the aerial photographs interpretation and field surveys Ulsan fault system was identified as an active reverse fault which has displaced the Quatemary fan deposits. Buguksa fault system strikes for the direction of NW-SE and N-S. These two lineaments of active fault are crossing at Jinty village in Gyeongju city and the fault plane forms here almost vertical dip. The lateral pressures from the two directions have possibly influenced on the formation of the vertical dip at jinty villagy. It should be resulted from that the two pressures responsible for the active reverse fault at which the one with the NW-SE strike thrusts the hanging wall of Tohamsan block southwestward and the other pressure with the N-S strike thrusts it westward over the foot wall of the fan deposits. The marine oxygen isotope stage 8(0.30-0.25 Ma. BP) and stage 6(0.20-0.14 Ma. BP) are presumed to be the ages of high and middle surfaces of the alluvial fan, repectively. The vertical displacements on the high surfaces along the Bulguksa fault system are about 1.05 m at Ha-Dong, 9.5-10.5 m at Jinhyun-Dong, and about 10 m high at Jinty village. And the vertical displacement on the middle surface was measured about 6 m high at Ha-Dong. The average slip rate of vertical displacements is calculated about 0.03-0.43 mm/y.

  • PDF

Fault current limitation characteristics of the Bi-2212 bulk coil for distribution-class superconducting fault current limiters (배전급 초전도 한류기 개발을 위한 Bi-2212 초전도 한류소자의 사고전류 제한 특성)

  • Sim, Jung-Wook;Kim, Hye-Rim;Yim, Seong-Woo;Hyun, Ok-Bae;Lee, Hai-Gun;Park, Kwon-Bae;Kim, Ho-Min;Lee, Bang-Wook;Oh, Il-Sung;Breuer, Frank;Bock, Joachim
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.639-640
    • /
    • 2006
  • We investigated fault current limitation characteristics of the resistive superconducting fault current limiter(SFCL) which consisted of a Bi-2212 bulk coil and a shunt coil. The Bi-2212 bulk coil and the shunt coil were connected in parallel. The Bi-2212 bulk coil was placed inside the shunt coil to induce field-assisted quench. The fault test was conducted at an input voltage of 200 $V_{rms}$ and fault current of 12 $kA_{rms}$ and 25 $kA_{rms}$. The fault conditions were asymmetric and symmetric, and the fault period was 5 cycles. The test results show that the SFCL successfully limited the fault current of 12 $kA_{rms}$ and 25 $kA_{rms}$ to below $5.5{\sim}6.9kA_{peak}$ within $0.64{\sim}2.17$ msec after the fault occurred. Limitation was faster under symmetric fault test condition due to the larger change rate of current. We concluded that the speed of fault current limitation was determined by the speed of current rise rather than the amplitude of a short circuit current. These results show that the Bi-2212 bulk coil is suitable for distribution-class SFCLs.

  • PDF

Transient Overloads Control Mechanism for Virtual Memory System (가상 메모리 시스템의 일시적인 과부하 완화 기법)

  • Go, Young-Woong;Lee, Jae-Yong;Hong, Cheol-Ho;Yu, Hyukc
    • The KIPS Transactions:PartA
    • /
    • v.8A no.4
    • /
    • pp.319-330
    • /
    • 2001
  • In virtual memory system, when a process attempts to access a page that is not resident in memory, the system generates and handles a page fault that causes unpredictable delay. So virtual memory system is not appropriate for the real-time system, because it can increase the deadline miss ratio of real-time task. In multimedia system, virtual memory system may degrade the QoS(quality of service) of multimedia application. Furthermore, in general-purpose operating system, whenever a new task is dynamically loaded, virtual memory system suffers from extensive page fault that cause transient overloading state. In this paper, we present efficient overloading control mechanism called RBPFH (Rate-Based Page Fault Handling). A significant feature of the RBPFH algorithm is page fault dispersion that keeps page fault ratio from exceeding available bound by monitoring current system resources. Furthermore, whenever the amount of available system resource is changed, the RBPFH algorithm dynamically adjusts the page fault handling rate. The RBPFH algorithm is implemented in the Linux operating system and its performance measured. The results demonstrate RBPFH\`s superior performance in supporting multimedia applications. Experiment result shows that RBPFH could achieve 10%∼20% reduction in deadline miss ratio and 50%∼60% reduction in average delay.

  • PDF