• Title/Summary/Keyword: fault lines

Search Result 356, Processing Time 0.032 seconds

Indirect adaptive nonlinear control for power system stabilization (전력계통안정화를 위한 간접적응 비선형제어)

  • 이도관;윤태웅;이병준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.454-457
    • /
    • 1997
  • As in most industrial processes, the dynamic characteristics of an electric power system are subject to changes. Amongst those effects which cause the system to be uncertain, faults on transmission lines are considered. For the stabilization of the power system, we present an indirect adaptive control method, which is capable of tracking a sudden change in the effective reactance of a transmission line. As the plant dynamics are nonlinear, an input-output feedback linearization method equipped with nonlinear damping terms is combined with an identification algorithm which estimates the effect of a fault. The stability of the resulting adaptive nonlinear system is investigated.

  • PDF

Reliability assesment of tilting train using Fault Diagnosis analysis device (고장진단분석장치를 이용한 틸팅열차 신뢰성 평가 연구)

  • Han, Seong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1203_1204
    • /
    • 2009
  • Korean Tilting trains have tested on conventional lines since the beginning of 2007 for evaluating its reliability. We achieved some major performance tests which are the maximum operation speed 180km/h test and the maximum curves increasing speed with tilting operation test. In order to analysis reliability data of tilting train, we have used the special data aquisition system which consists of monitor, sensors and depot computer etc. As a results of calculation, until now we realized that the reliability are getting more increasing than starting point of running test.

  • PDF

Power system stabilization via adaptive feedback linearization (비선형 적응제어를 이용한 전력계통 안정화)

  • 윤태웅;이도관
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1221-1224
    • /
    • 1996
  • As in most industrial processes, the dynamic characteristics of an electric power system are subject to changes. Amongst those effects which cause the system to be uncertain, faults on transmission lines are considered. For the stabilization of the power system, we present an indirect adaptive control method, which is capable of tracking a sudden change in the effective reactance of a transmission line. As the plant dynamics are nonlinear, an input-output feedback linearization method is combined with an identification algorithm which estimates the effect of a fault.

  • PDF

Development of Automatic Power Restoration System And Operation in KEPCO Real Power System (정전자동복구시스템의 개발 및 한전 실계통 적용)

  • Hong, Soon-Chun;Choo, Jin-Boo;Lee, Nam-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.49-51
    • /
    • 2001
  • Recently, according to a rapid increase of the power demand, the KEPCO's 154kV lines are continuously expanded and become to the more complex loop system. As a result of increase of the fault capacity and the unbalance of power load flow, the circuit breaker have been exceeding the capacity limit of those in the loop power system. To solve this problem, APRS application will be necessary more and more.

  • PDF

Design of Data Retention Test Circuit for Large Capacity DRAMs (대용량 Dynamic RAM의 Data Retention 테스트 회로 설계)

  • 설병수;김대환;유영갑
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.9
    • /
    • pp.59-70
    • /
    • 1993
  • An efficient test method based on march test is presented to cover line leakage failures associated with bit and word lines or mega bit DRAM chips. A modified column march (Y-march) pattern is derived to improve fault coverage against the data retention failure. Time delay concept is introduced to develop a new column march test algorithm detecting various data retention failures. A built-in test circuit based on the column march pattern is designed and verified using logic simulation, confirming correct test operations.

  • PDF

The Exploration of Teaching through the Analysis of Statistics Graphics in the Newspaper (신문의 통계 그래프 분석을 통한 지도 방법 탐색)

  • 박영희
    • School Mathematics
    • /
    • v.1 no.2
    • /
    • pp.451-459
    • /
    • 1999
  • The teaching through the graphics in the newspaper which students look at easily, will encourage the student's interest and make them learn the principle of representing the statistics graphics. In this paper, we analyzed the cases of the bar chart and the graph of broken lines which is seen many in the newspaper. Through showing the good point and fault of the graphic cases, we intend that students know the principle of analyzing or making the statistics graphics.

  • PDF

Analysis of Insulator Failures Altar Installation of Arcing Horns in 154kV Transmission Lines (154kV 송전선로 Arcing Horn 적용에 따른 애자련 사고분석)

  • Cho, S.B.;Lee, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1743-1745
    • /
    • 1998
  • Insulators of 154kV T/L have been frequently damaged by fault currents. Arcing horn is a very effective and economic method for protection of insulators from the flashover. We developed arcing horns for 154kV T/L in order to protect insulators from the arc[1]. This paper analyzes the status of insulator failures in 154kV T/L after installation of the arcing horns.

  • PDF

Computer Computation of Induced Voltages in Communication Line, adjacent to Power Line (배전전압 승압에 따른 근접통신선로에서의 유도전압에 대한 콤퓨터 계산)

  • 김기룡;황규선
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.7 no.4
    • /
    • pp.67-82
    • /
    • 1970
  • In this paper, formulas are developed for computing induced line voltages incommunication lines due to power line failure. Formulas are expressed in terms of fault current, mutual impedance andlength of line. Computed results are shown for various power line valtages and length of line. (Computation is done by IBM 1130-3B Computer system at Soong Sil Compute Center)

  • PDF

Protection System Characteristics Analysis by Compensation Equipment in Power Systems (보상제어 설비의 운용에 따른 보호설비 특성분석)

  • Park, Ji-Hoon;Sul, Tong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1006-1008
    • /
    • 1998
  • This paper describes the possible undesier-able side effects that thyristor controlled compensation may have upon in several relays. This process consisted of calculating line conditions for each of the fault, compensation and loading levels. In some cases their effectiveness at coordinating compensated lines is lost, as they no longer can always accurately determine "distances" to faults.

  • PDF

Palaeomagnetism of Cretaceous Rocks in the Ǔisǒng Area, Kyǒngsang Basin, Korea (의성지역 백악기 암석에 대한 고자기 연구)

  • Kim, In-Soo;Lee, Hyun Koo;Yun, Hyesu;Kang, Hee-Cheol
    • Economic and Environmental Geology
    • /
    • v.26 no.3
    • /
    • pp.403-420
    • /
    • 1993
  • The Cretaceous Kyongsang Basin is known to be composed of several tectonic blocks (or subbasins) with each distinct stratigraphic succession. The study area represents a major part of one of these blocks, i. e. the $\check{U}is\check{o}ng$ block. The area is charaterized by a suite of WNW-trending sinistral strike-slip faults as well as a number of ring faults. A total of 292 independently oriented core samples were drilled from 23 sites, covering virtually all the formations of the Cretaceous $Ky\check{o}ngsang$ Supergroup. Alternating field and thermal demagnetization experiments were conducted to reveal the primary magnetization. Due to the homoclinal nature of the strata in the area, it was not possible to make use of the conventional fold test It is, however, believed that the primary remanent components have been obtained from the majority of the formations, considering the similarity of the palaeomagnetic pole positions with those of contemporary strata of other blocks and the existence of antiparallel reversed remanence. It was found neither any significant difference in magnetic declination on each side of the strike-slip faults nor systematic change of magnetic declination with distance from the fault-line. This does not support such a block rotation hypothesis associated with the strike-slip faulting in the area as alleged by some authors. The samples from the outcrops on or near the fault-lines were severely overprinted by the recent magnetic fields regardless of age and lithology. Epithermal Au-Ag-Cu-Pb-Zn mineralizations are known along some fault lines in the area. It is interpreted that these two facts are closely related with fluid circulations along the fracture zones caused by fault activities. In regard to the age of the strata as deduced from the magnetostratigraphic consideration, the $Ch\check{o}mgok$ formation and the lower strata should be older than Barremian or 124 Ma. The age of volcanics of the $Yuch^{\prime}\check{o}n$ Group sampled in this study should be younger than Campanian or 83 Ma.

  • PDF