• Title/Summary/Keyword: fault lines

Search Result 356, Processing Time 0.031 seconds

Variation of Transient-response in Open-ended Microstrip Lines with Optically-controlled Microwave Pulses

  • Wang, Xue;Kim, Kwan-Woong;Kim, Yong-K.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.2
    • /
    • pp.53-57
    • /
    • 2009
  • In this paper we develop a method to observe faults in semiconductor devices and transmission lines by calculating the variation of the reflection function in a dielectric microstrip line that has an open-ended termination containing an optically induced plasma region. It is analyzed with the assumption that the plasma is distributed homogeneously in laser illumination. With the non linear material of degradation, the concentration of the carrier in the part of the material has changed. Since the input wave has produced the phenomenon of reflection, the input signal to the open-ended microstrip lines can be observed on reflection to identify the location of the fault. The characteristic impedances resulting from the presence of plasma are evaluated by the transmission line model. The variation of the reflection wave in the microwave system has been calculated by using an equivalent circuit model. The transient response has been also evaluated theoretically for changing the phase of the variation in the reflection. The variation of characteristic response in differentially localized has been also evaluated analytically.

Subsurtace Geological Structure of the Downstream Area of the Jangsung Lake (장성호 하류지역의 지하지질구조)

  • 김성균;김용준;오진용;김민선;서구원
    • The Journal of Engineering Geology
    • /
    • v.7 no.2
    • /
    • pp.101-112
    • /
    • 1997
  • Gravity and electrical resistivity surveys were carried out across the Kwangju fault in the downstream area of the Jangsung Lake, to investigate the location and geometrical feature of the fault. In the resistivity survey, dipole - dipole array method was adopted for 3 survey lines of which length and electrode spacing are 500m and 25m, respectively. Resistivity data are interpreted with aid of computer program "RESIS" which is widely used in resistivity data analysis and two dimensional resistivity profiles are obtained for 3 survey lines. Two large fracture zones relevant to the Kwangju fault are identified in the resistivity profiles. The total of 80 gravity data are observed with the mean spacing of 40 m and the exact leveling is accompanied to obtain more precise gravity anomalies. The subterranean density discontinuities calculated from the inverse method are appeared at the depths of 650rn and 120m. It is considered that the deep discontinuity indicates boundary between Jurassic granites and oveflying Cretaceous tuff formation. while, the shallow discontinuity is interpreted to be a boundary between alluvial deposits and basements. The subsurface geological structure to satisfy the observed Bouguer anomaly is determined from the iterative forward method in which results from existing surface geological informations, the inverse method, and from the resistivity interpretations are employed as an iuitial model. In conclusion, Kwangju fault is appeared to be a high angle normal fault mainly formed in tension stress filed.

  • PDF

Development of Pipe Fault Inspection System using Computer Vision (컴퓨터 비젼을 이용한 파이프 불량 검사시스템 개발)

  • 박찬호;양순용;안경관;오현옥;이병룡
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.10
    • /
    • pp.822-831
    • /
    • 2003
  • A computer-vision based pipe-inspection algorithm is developed. The algorithm uses the modified Hough transformation and a line-scanning approach to identify the edge line and the radius of the pipe image, from which the eccentricity and dimension of the pipe-end is calculated. Line and circle detection was performed using Laplace operator with input image, which are acquired from the front and side cameras. In order to minimize the memory usage and the processing time, a clustering method with the modified Hough transformation is introduced for line detection. The dimension of inner and outer radius of pipe is calculated by the proposed line-scanning method. The method scans several lines along the X and Y axes, calculating the eccentricity of inner and outer circle, by which pipes with wrong end-shape can be classified and removed.

Fault Detection of Reciprocating Compressor for Small-Type Refrigerators Using ART-Kohonen Networks and Wavelet Analysis

  • Yang, Bo-Suk;Lee, Soo-Jong;Han, Tian
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.12
    • /
    • pp.2013-2024
    • /
    • 2006
  • This paper proposes a condition classification system using wavelet transform, feature evaluation and artificial neural networks to detect faulty products on the production line of reciprocating compressors for refrigerators. The stationary features of vibration signals are extracted from statistical cumulants of the discrete wavelet coefficients and root mean square values of band-pass frequencies. The neural networks are trained by the sample data, including healthy or faulty compressors. Based on training, the proposed system can be used on the automatic mass production line to classify product quality instead of people inspection. The validity of this system is demonstrated by the on-site test at LG Electronics, Inc. for reciprocating compressors. According to different products, this system after some modification may be useful to increase productivity in different types of production lines.

The analysis and countermeasure to the lightning fault of transmission facilities (송전설비의 낙뢰고장사례 분석과 대책)

  • Sin, S.G.;An, J.S.;Bak, S.Y.;NamKung, D.;Han, S.O.;Choi, N.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.412-415
    • /
    • 2000
  • Generally, the fault of transmission facilities occurs by natural and artificial causes. Also, these faults are frequently developed by the lightning, a natural phenomenon. Therefore, In this paper, we investigated the case of lightning faults for transmission lines occurred for five years in the west and south of chung-nam province, and then considered a suitable countermeasure for lighting faults in these area

  • PDF

A Weighted Random Pattern Testing Technique for Path Delay Fault Detection in Combinational Logic Circuits (조합 논리 회로의 경로 지연 고장 검출을 위한 가중화 임의 패턴 테스트 기법)

  • 허용민;임인칠
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.12
    • /
    • pp.229-240
    • /
    • 1995
  • This paper proposes a new weighted random pattern testing technique to detect path delay faults in combinational logic circuits. When computing the probability of signal transition at primitive logic elements of CUT(Circuit Under Test) by the primary input, the proposed technique uses the information on the structure of CUT for initialization vectors and vectors generated by pseudo random pattern generator for test vectors. We can sensitize many paths by allocating a weight value on signal lines considering the difference of the levels of logic elements. We show that the proposed technique outperforms existing testing method in terms of test length and fault coverage using ISCAS '85 benchmark circuits. We also show that the proposed testing technique generates more robust test vectors for the longest and near-longest paths.

  • PDF

Resistance distribution in large area thin film type SFCLS (박막형 대면적 초전도 한류소자에서의 저항 분포)

  • 김혜림;최효상;현옥배
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.89-93
    • /
    • 2002
  • We investigated the resistance distribution n 4"diameter SFCLS. $YBa_2CU_3O_7$ films coated in-situ with a gold layer were patterned into 3 mm wide 142 cm long meander lines by Photolithography. The limiters were tested with simulated fault currents. The resistance was uniform all over the film except at the edge. At lower source voltages, CFCLs did not quench simultaneously and the resistance distribution was less uniform. Compared with 2" diameter SFCLS 4" SFCLS had similar values and time dependence of resistivity at similar electric fields The resistance distribution was more uniform in 4" SFCLS. The area at the edge where the distribution was not uniform was around 3 mm wide in SFCLs of both sizes. The experimental results were quantitatively explained with a heat transfer concept.

AFCI algorithm design without sensor (센서없는 AFCI 알고리즘 설계)

  • Ban, Gi-Jong;Choi, Sung-Dai;Ho, Yoon-Kwang;Kim, Sang-Hoon;Nam, Moon-Hyon;Kim, Lark-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.231-233
    • /
    • 2006
  • Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, arc current control algorithm is designed for the interruption of arc fault current which is occurred in the low voltage network. This arc is one of the main causes of electric fire. General arc current sensor has troubles for detecting arc currents, thus we would like to propose the arc current detection method without current sensor. In this paper, arc discharge currents within power lines are being detected through the arc current control algorithm.

  • PDF

A Study on the Integrated Diagnosis System for Unmanned Substation and Transmission Network in Local Control Center (지역급전 제어소의 무인변전소와 송전망 통합진단 시스템에 관한 연구)

  • Lee, Heung-Jae;Lim, Chan-Ho;Choi, Gi-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.516-518
    • /
    • 1995
  • This paper presents an integrated fault diagnosis expert system for power systems. The proposed system diagnoses various faults occurred in both substations and transmission lines even in the case that substation fault is spreaded over the network. To cope with this problem, A meta-inference method is proposed. This scheme shares same the data structure with the pre-developed intelligent operational aid expert system installed in a practical sub-control center, without modification. This advanced integrated diagnosis system is developed using a low cost personal computer owing to the special modular programming technique. Case studies show a promising possibility of the proposed method.

  • PDF

Communication Redundancy for Reliability Improvement in an Industrial Monitoring and Control System

  • Rhyu, Keel-Soo;Chung, Kyung-Yul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1291-1298
    • /
    • 2004
  • In development of monitoring and control systems, one of the most important points is to consider a redundancy so that the system can be operated normally although hardware faults are partly occurred. The purpose of this paper is to introduce a monitoring and control system with a redundancy function for I/O servers and communication networks. I/O servers composed with an active server and a standby server. Each server also has 3 communication ports, 2 ports of them were connected to field units and the other 1 port was connected to the other server. Field units have to be constructed to 2 communication ports connected I/O servers through communication lines. Also, server communication module was implemented for analyzing and handling fault elements. and was submodularized for linking easily with a monitoring and control module. An experiment with 2 servers and 2 field units was constructed to demonstrate its effectiveness.