• Title/Summary/Keyword: fault area

Search Result 802, Processing Time 0.035 seconds

Evaluation of Seismic Responses for Building in Moderate Seismicity Regions Considered Vertical Earthquake Ground Motions (지진지반운동의 수직성분을 고려한 증진지역 건축구조물의 지진응답평가)

  • Han, Duck-Jeon;Ko, Hyun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.1
    • /
    • pp.69-78
    • /
    • 2009
  • Recent earthquake, such as the Northridge(1994), the Kobe(1995) and the Izmit(1990) earthquakes, gave serious damage in various buildings and bridges by the vertical seismic component. Most of the seismic designs neglect the vertical seismic component for usual frame structures. The purpose of this study is to evaluate the effects of the vertical seismic component and to compare the axial force of columns and plastic rotation angle of the analytical models in these effects. The vertical seismic component produced a large increment of axial force in columns. And the vertical seismic component caused a significant increase of the damage in the columns. As analysis result, increase of axial force cause the damage of columns and give possibility of story collapse mechanism of the structure system. Therefore, area that near fault ground motion is expected may be consider the effect of vertical component of seismic ground motions.

  • PDF

Quaternary Tectonic Movement on Cheju Island (제주도의 제4기 지구조운동)

  • Hwang, Jae Ha;Lee, Byung Joo;Song, Kyo Young
    • Economic and Environmental Geology
    • /
    • v.27 no.2
    • /
    • pp.209-212
    • /
    • 1994
  • Cheju Island was formed by volcanic activity probably related to the inferred geodynamics in the early Quaternary times. Paleostress analysis, in spite of a few fault slip data collected near Sanbangsan trachyte dome (dated 0.87 Ma) represents an extentional tectonic event with the direction ENE-WSW. Joint anayses in the vicinity of Seahwa reveal three extensional tectonic events of directions NW-SE, NE-SW and ENE-WSW. Especially the extensional event with the direction ENE-WSW affected the whole Cheju area during the most recent time.

  • PDF

Assessment Method and Calculations for Protective Conductor of TN-S System and IEC 60364 Application (IEC 60364 적용 및 TN-S 시스템에서 보호 도체 산정 및 적정성에 관한 연구)

  • Kim, Gi-Hyun;Lee, Ju-Chul;Choi, Young-Kyu;Kim, Han-Su;Lee, Young-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.86-91
    • /
    • 2012
  • A conductor has been produced according to IEC standard and low voltage electrical facility has been installed according to IEC 60364. So we must comply with international standard for design, construction and inspection. But because of many related and varied standards, it is difficult to apply to design and inspect for electrical equipment. We researched the necessity of design guide which is detailed and systematization from survey. For detailed design guide, we suggest calculation method of protective conductor cross-sectional area at TN-S system according to BS 7671 regulation and KS C IEC 60364 standard.

Protection Management for Guaranteed User-Driven Virtual Circuit Services in Dynamic Multi-domain Environments: Design Issues and Challenges

  • Lim, Huhnkuk
    • ETRI Journal
    • /
    • v.37 no.2
    • /
    • pp.369-379
    • /
    • 2015
  • Fault management of virtualized network environments using user-driven network provisioning systems (NPSs) is crucial for guaranteeing seamless virtual network services irrespective of physical infrastructure impairment. The network service interface (NSI) of the Open Grid Forum reflects the need for a common standard management API for the reservation and provisioning of user-driven virtual circuits (VCs) across global networks. NSI-based NPSs (that is, network service agents) can be used to compose user-driven VCs for mission-critical applications in a dynamic multi-domain. In this article, we first attempt to outline the design issues and challenges faced when attempting to provide mission-critical applications using dynamic VCs with a protection that is both user-driven and trustworthy in a dynamic multi-domain environment, to motivate work in this area of research. We also survey representative works that address inter-domain VC protection and qualitatively evaluate them and current NSI against the issues and challenges.

Mobile Node Management Algorithm considering Load Balancing in Wireless Environment (무선 환경에서 부하 균등화를 고려한 모바일 노드 관리 알고리즘)

  • Choi, Young-Ho;Choi, Jae-Hyeok;Shin, Kwang-Sik;Choi, Sang-Bang
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.23-26
    • /
    • 2005
  • This paper presents the load balance of Mobile IP in wireless systems. Mobile IP can support wireless users with continuous network connections while changing locations. If a failure occurs in a mobility agent, the wireless users located in the coverage area of the fault mobility agent will lose their network connections. To tolerate the failure of mobility agents, this paper proposes the method of an efficient approach to reduce severe overload.

  • PDF

Characteristics of Silicon Carbide Nanowires Synthesized on Porous Body by Carbothermal Reduction

  • Kim, Jung-Hun;Choi, Sung-Churl
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.3
    • /
    • pp.285-289
    • /
    • 2018
  • We synthesized silicon carbide (${\beta}-SiC$) nanowires with nano-scale diameter (30 - 400 nm) and micro-scale length ($50-200{\mu}m$) on a porous body using low-grade silica and carbon black powder by carbothermal reduction at $1300-1600^{\circ}C$. The SiC nanowires were formed by vapor-liquid-solid deposition with self-evaporated Fe catalysts in low-grade silica. We investigated the characteristics of the SiC nanowires, which were grown on a porous body with Ar flowing in a vacuum furnace. Their structural, optical, and electrical properties were analyzed with X-ray diffraction (XRD), transmission electron microscopy (TEM), and selective area electron diffraction (SAED). We obtained high-quality SiC single crystalline nanowire without stacking faults that may have uses in industrial applications.

A Study on Insuring the Full Reliability of Finite State Machine (유한상태머신의 완벽한 안정성 보장에 관한 연구)

  • Yang Sun-Woong;Kim Moon-Joon;Park Jae-Heung;Chang Hoon
    • Journal of Internet Computing and Services
    • /
    • v.4 no.3
    • /
    • pp.31-37
    • /
    • 2003
  • In this paper, an efficient non-scan design-for-testability (DFT) method for finite state machine(FSM) is proposed. The proposed method always guarantees short test pattern generation time and complete fault efficiency. It has a lower area overhead than full-scan and other non-scan DFT methods and enables to apply test patterns at-speed. The efficiency of the proposed method is demonstrated using well-known MCNC'91 FSM benchmark circuits.

  • PDF

Revised Geology of the Deokjeok and Soya Islands in the Central-western Korean Peninsula

  • Park, Jeong-Yeong;Park, Seung-Ik
    • Economic and Environmental Geology
    • /
    • v.53 no.5
    • /
    • pp.631-643
    • /
    • 2020
  • The central-western Korean Peninsula contains records of an Early Mesozoic collisional event related to the final amalgamation of the East Asian continent. Here, we present a renewed geologic map of the Deokjeok and Soya islands in the central-western Korean Peninsula and its explanatory note. Our geologic map was based on a detailed investigation of the northeastern area of both islands, which is characterized by a complex fault and shear zone system that accommodated the crustal deformation related to the Mesozoic post-collisional orogenic collapse and the subsequent structural inversion. We suggest future directions of study aiming at addressing issues regarding the deformational responses of crust to the Mesozoic tectonic transition and orogenic cycles.

Protection system of new superconducting power system (초전도(신)전력계통 보호시스템에 관한 기본연구)

  • Lee, Seung-Ryul;Yoon, Jae-Young;Yang, Byeong-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.292-293
    • /
    • 2011
  • We proposed a new power system, Superconducting Power System. The SPS consists of superconducting power cables, fault current limiters, and transformers. The basic concept is to replace 154kV conventional cables with 22.9kV superconducting cables and to convert a 154kV substation into a 22.9kV switching station in downtown area. For the application of the SPS to real power system, it is very important to construct the protection system of the SPS. This study presents a protection system for the new Superconducting Power System (SPS).

  • PDF

A Study on Financial Loss Assessment of Voltage Sags (순간전압강하 경제적 손실 평가 연구)

  • Park, Jomg-Il;Song, Young-Won;Park, Chang-Hyun;Jang, Gil-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.324-325
    • /
    • 2011
  • This paper addresses the assessment of voltage sag costs based on the stochastic prediction of voltage sags. When voltage sags below a certain voltage threshold occur at sensitive industrial process, the industrial customer will experience financial damage. In order to mitigate voltage sag costs and devise efficient solutions to mitigate damage, a study on the financial loss assessment of voltage sags is basically needed. In order to assess the voltage sag costs, the expected sag frequency at a sensitive load point should be calculated by using the concept of the area of vulnerability and historical fault statistics. Then, financial loss due to voltage sags can be obtained by multiplying the expected sag frequency by the cost per sag event.

  • PDF