• 제목/요약/키워드: fault area

검색결과 802건 처리시간 0.027초

주행면 단차에 의한 AGT 교량 충격에 관한 실험적 연구 (A Experimental Study on the Impact of AGT Bridge by the Prominence of Railway Surface)

  • 최성규;조선규;이안호;송재필
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.511-516
    • /
    • 2007
  • Rubber wheeled AGT(Automated Guide-way Transit) system is a prominence transportation system for urban area, because of its low construction cost and management, low noise and vibration and fine exterior view. AGT system uses concrete tracks. Concrete can be easily damaged by the impact, change of temperature and external loads. The fault of concrete track is harmful not only to riding quality but also to bridge. Therefore, in this study, the effects of railway prominence to the bridge are surveyed by experimental method. The experiment was executed for PSC bridge at AGT test line in Kyungsan. And the test results for 5mm, 10mm prominence and without prominence are compared and investigated, according to the vehicle speed.

  • PDF

캐나다 아타바스카 분지 부정합형 우라늄광상 물리탐사 사례 (Geophysical Exploration on Unconformity-type Uranium Deposit in Athabaska Basin, Canada)

  • 유영준;김재철
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2009년도 특별 심포지엄
    • /
    • pp.73-87
    • /
    • 2009
  • Geophysical survey for unconformity-type uranium deposit applied to this study area in Athabaska Basin, Canada were carried out airborne TEM and magnetic, resistivity-induced polarization (DC-IP), puser seismic reflection and well-logging method. The results of airborne survey interpreted the lithological boundary, geological structures, and conductors. Also, these results decided to main targets for ground DC-IP survey. The Low resistivity and the high chargeability slices of 3D modeling interpreted from DC-IP survey response for conductors related to hydrothermal alteration zones and fault-controlled graphitic zones occurring at the unconformity-type uranium deposit, and they confirmed by diamond drilling. Seismic results interpreted to lake bottom surface, alluvium layer and intra-sandstone faults. We suggest the resonable field data acquisition of DC-IP method on the land or the lake in Athabaska Basin.

  • PDF

금/YBCO 박막에서의 quench 저항 발생 (Resistance development in Au/YBCO thin film meander lines during quench)

  • Kim, Hye-Rim;Choi, Hyo-Sang;Lim, Hae-Ryong;Kim, In-Seon;Hyun, Ok-Bae
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.252-256
    • /
    • 2000
  • We investigated resistance development in Au/YBCO thin film meander lines during quench. The meander lines were fabricated by coating YBCO films insitu with a gold layer and patterning them by photolithography. The center stripe quenched fastest even though the flux flow resistance that appeared upon the current passing the critical current was uniform. Quench started at an area of the center stripe and propagate both through the gold layer and the sapphire substrate. Quench propagation speed was uniform and 60 cm/s at 30 V$_{rms}$.

  • PDF

서버 독립적 LAN 이중화 모듈을 통한 네트워크 속도 및 가용성 향상 방안 (Dual LAN Topology with the Dual Path Ethernet Module)

  • 박지훈;박종규;한일석;김학배
    • 제어로봇시스템학회논문지
    • /
    • 제8권3호
    • /
    • pp.264-269
    • /
    • 2002
  • A Dual-Path Ethernet Module(DPEM) is developed to improve Local Area Network (LAN)'s performance, High Availability(H/A) and security. Since a DPEM simply locates at the front end of any network device as a transparent add-on, it does not require sophisticated server reconfiguration. Our evaluation results show that the developed scheme is more efficient than conventional LAN structures in various aspects.

분산전원을 고려한 적응적 재폐로 기법 (An Adaptive Reclosing Technique Considering the Distributed Generation)

  • 서훈철;김철환;여상민
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.227-232
    • /
    • 2007
  • The autoreclosing is applied to power system for maintaining system stability and continuity of supply. Developments on distributed generation(DG) grows significantly by environmental issues and economical issues. If the DG is connected to distribution system, the DG influences the technical aspects such as power quality, protection and stability. It causes the challenges to protection, especially to reclosing. In order to achieve reliability and safety of the distribution system, the rules and guidelines suggest that the DG units should be rapidly disconnected from the network before the reclosing. If the DG is disconnected whenever the fault occurs, it cannot be utilized effectively. This paper presents the adaptive reclosing algorithm considering the DG. The algorithm consists of angle oscillation's judgment, EEEAC(Emergency Expanded Equal-Area Criterion), calculation of optimal reclosing time and re-connection algorithm. The simulation is implemented for the DG technology by using EMTP MODELS. The simulation results show that the transient stability is maintained and the DG is protected against disturbance.

배전자동화시스템의 도입이 배전계통신뢰도 향상에 기여한 사례 연구 (A Study on the Improved Efficiency of Distribution Network Reliability Using DAS)

  • 황우현;배성환;김자희;김재철
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2059-2064
    • /
    • 2007
  • This paper analyzed distribution network reliability related with the increment of outages and duration time according to distribution facilities increasing. KEPCO introduced distribution automation system in 1998 which could recognize outage section by remotely monitoring the fault current and reduce the blackout area by remotely controlling distribution switches. As the result of this outage time reduction using distribution automation system, the minimum distribution automation rate was fined out in this paper on the base of analyzing diverse data and how many switches were used in distribution system to improve distribution network reliability at the situation of distribution facilities increasing. This result can be used as the model that an overseas utility company applies distribution automation system in the future.

광역보호를 위한 주파수 측정기법에 관한 연구 (A Study on Frequency Measurement Technique for Wide Area Protection)

  • 박철원;김윤상;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2023-2024
    • /
    • 2008
  • 근래 초기고장(seed fault)에 대한 적절치 못한 대책들이 광역정전으로 파급되어 그 피해정도가 매우 심각하다. 전력의 안정적 공급에 대한 중요성이 새롭게 부각되고 그 예방책에 대한 다각적인 연구가 요구되고 있다. 이에 위성망을 이용한 위기 관리시스템에 대한 필요성이 제기되었다. 본 논문에서는 광역보호를 위해 sPMU(satellite Phasor Measurement Unit), 전력계통 상태감시장치(Power System Dynamic Monitor:PSDM)에 중요한 요소로서 전력계통에서 가장 중요한 지표중의 하나인 주파수에 대한 여러 가지 측정방법을 다룬다. 향후 정상상태와 과도상태에서도 측정시간 단축과 측정오차를 줄일 수 있는 최적의 주파수 계측기법을 개발하기 위함이다.

  • PDF

MCCB 내의 온도장에 대한 수치적 연구 (A Numerical Study on Temperature Fields in MCCB)

  • 박성규;이종철;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.145-150
    • /
    • 2003
  • In this paper we have studied the characteristics of temperature fields in a Molded Case Circuit Breaker (MCCB). A switch and a trip device are arranged in narrow space of the MCCB. Thus, thermal factors have been risen to important problem. The temperature rise means an energy loss and it becomes the reason of fatal fault in devices. Also, the temperature rise on the connection and the contact parts is regulated up to $115^{\circ}C$ and $105^{\circ}C$, respectively. Therefore, a study for preventing the temperature rise should be investigated. A numerical analysis method that has confidence might be preceded for this purpose. In order to verify the confidence of temperature field analysis, the results of the numerical analysis are compared with those of experimental one for the same model. Comparison results show a qualitatively good agreement within ${\pm}5%$ errors.

  • PDF

Self-Localized Packet Forwarding in Wireless Sensor Networks

  • Dubey, Tarun;Sahu, O.P.
    • Journal of Information Processing Systems
    • /
    • 제9권3호
    • /
    • pp.477-488
    • /
    • 2013
  • Wireless Sensor Networks (WSNs) are comprised of sensor nodes that forward data in the shape of packets inside a network. Proficient packet forwarding is a prerequisite in sensor networks since many tasks in the network, together with redundancy evaluation and localization, depend upon the methods of packet forwarding. With the motivation to develop a fault tolerant packet forwarding scheme a Self-Localized Packet Forwarding Algorithm (SLPFA) to control redundancy in WSNs is proposed in this paper. The proposed algorithm infuses the aspects of the gossip protocol for forwarding packets and the end to end performance of the proposed algorithm is evaluated for different values of node densities in the same deployment area by means of simulations.

전자기 과도현상 해석을 위한 Z 영역에서의 주파수 의존 교류시스템 등가 (Z-Domain Frequency Dependent AC System Equivalent for Electromagnetic Transient Studies)

  • 왕용필;정형환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권6호
    • /
    • pp.296-301
    • /
    • 2002
  • Modern power systems are very complex and to model them completely is impractical for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). In this paper a method for developing Frequency Dependent AC system Equivalent (FDACSE) using Z-domain rational Function Fitting is presented and demonstrated. The FDACSE is generated by Linearized Least Squares Fitting(LSF) of the frequency response of a Z-domain formulation. This 1 & 2 port FDACSE have been applied to the New Zealand South Island AC power system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 1 & 2 port FDACSE developed under different condition (linear load, fault and nonlinear loading). The study results have indicated the robustness and accuracy of 1 & 2 port FDACSE for electromagnetic transient studies.