• 제목/요약/키워드: fault area

검색결과 802건 처리시간 0.023초

간선 및 분기선의 개폐기 설치 효과 분석(I) (Reliability analysis of the switch installation in the main feeder and in the radial/loop lateral feeders in distribution system)

  • 조남훈;오재형;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.79-82
    • /
    • 2002
  • The addition of switches to a distribution feeder does, in general, increase reliability by decreasing the duration of the outage of many to the customers on the feeder. To cover its service area so that feeder-level delivery reaches sufficiently close to all customers, feeders typically split their routes many times, in what is often called a lateral feeder. It is interesting to note, however, that the effectiveness of a switch is very much dependent on the types of lateral feeder. The types of lateral are classified into two types. The first is loop lateral feeder that can connect its load to an adjacent feeder through a tie line in case that a fault occurs in its feeder and it is laid out so that every feeder has complete fault backup through re-switching of its loads to other sources like a main feeder. The second is the radial lateral feeder cannot connect its load to an adjacent line, no provision is made for contingency backup of feeders. There are no other circuits in the radial lateral feeder form which to restore power. In this study, we evaluate the effectiveness of a switch installation between on the radial and loop lateral feeders to increase reliability by decreasing the duration of the outage. These results can help power utility to design the switch layouts on the radial and loop lateral feeder system.

  • PDF

1.8GHz 고주파 전단부의 결함 검사를 위한 새로운 BIST 회로 (A New Fault-Based Built-In Self-Test Scheme for 1.8GHz RF Front-End)

  • 류지열;노석호
    • 대한전자공학회논문지TC
    • /
    • 제42권6호
    • /
    • pp.1-8
    • /
    • 2005
  • 본 논문에서는 1.8GHz 고주파 수신기 전단부의 결함 검사를 위한 새로운 저가의 BIST 회로(자체내부검사회로) 및 설계기술을 제안한다. 이 기술은 입력 임피던스 매칭 측정 방법을 이용한다. BIST 블록과 고주파 수신기의 전단부는 0.25m CMOS 기술을 이용하여 단일 칩 위에 설계되었다. 이 기술은 측정이 간단하고 비용이 저렴하며, BIST 회로가 차지하는 면적은 고주파 전단부가 차지하는 전체면적의 약 $10\%$에 불과하다.

전도냉각되는 1-2kV급 고온초전도 직류리액터 전류도입부의 전기적 절연에 대한 연구 (Study on the Electrical Insulation of Current Lead in the conduction-cooled 1-2kV Class High-Tc Superconducting DC Reactor)

  • 배덕권;안민철;이찬주;정종만;고태국;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.30-34
    • /
    • 2002
  • In this Paper, Insulation of current lead in the conduction-cooled DC reactor for the 1.2kV class 3 high-Tc superconducting fault current limiter(SFCL) is studied. Thermal link which conducts heat energy but insulates electrical energy is selected as a insulating device for the current lead in the conduction-cooled Superconducting DC reactor. It consists of oxide free copper(OFC) sheets, Polyimide films, glass fiberglass reinforced Plastics (GFRP) plates and interfacing material such an indium or thermal compound. Through the test of dielectric strength in L$N_2$, polyimide film thickness of 125 ${\mu}{\textrm}{m}$ is selected as a insulating material. Electrical insulation and heat conduction are contrary to each other. Because of low heat conductivity of insulator and contact area between electrical insulator and heat conductor, thermal resistance of conduction-cooled system is increased. For the reducing of thermal resistance and the reliable contact between Polyimide and OFC, thermal compound or indium can be used As thermal compound layer is weak layer in electrical field, indium is finally selected for the reducing of thermal resistance. Thermal link is successfully passed the test. The testing voltage was AC 2.5kVrms and the testing time was 1 hour.

사물탕가미방이 백서의 좌우 중대뇌 동맥 폐쇄에 의한 뇌허혈 손상의 회복에 미치는 효과 (Effects of Samul-tang-gamibang against Focal Cerebral Ischemic Damage by Middle Cerebral Artery Occulusion of Rats)

  • 서창훈;김영균;권정남
    • 대한한의학회지
    • /
    • 제25권1호
    • /
    • pp.117-128
    • /
    • 2004
  • Objectives : This research was performed to investigate effect of Samul-tang-gamibang against focal cerebral ischemic damage after middle cerebral artery occlusion(MCAO). Methods : This research was used rats which were against focal cerebral ischemic damage by MCAO. It was used Zea Longa's theory and Belayev's methods to give rise to focal cerebral ischemic damage by MCAO. After 7days later, we drew out the brain and then had frozen and dyeing it and we had taken a picture to measure of the damaged area in each brain section. We determined the Neurological Index and tested the Foot-fault test and Roatated test to appraise the fall of motion ability result from cerebral ischemic damage. Results : The results of the experiment are as follows. 1. Samul-tang-gamibang reduced infarct size of sample group compared to control group at 7 day after MCAO. 2. Samul-tang-gamibang reduced infarct volume of sample group compared to control group at 7 day after MCAO. 3. Samul-tang-gamibang reduced foot-fault index of sample group compared to control group at 5,7 day after MCAO. Conclusions : Samul-tang-gamibang has protective effects against ischemic brain damage and had significant reduced infarct size and infarct volume of Rt-MCAO.

  • PDF

열화상 이미지를 이용한 배전 설비 검출 및 진단 (Detection and Diagnosis of Power Distribution Supply Facilities Using Thermal Images)

  • 김주식;최규남;이형근;강성우
    • 대한안전경영과학회지
    • /
    • 제22권1호
    • /
    • pp.1-8
    • /
    • 2020
  • Maintenance of power distribution facilities is a significant subject in the power supplies. Fault caused by deterioration in power distribution facilities may damage the entire power distribution system. However, current methods of diagnosing power distribution facilities have been manually diagnosed by the human inspector, resulting in continuous pole accidents. In order to improve the existing diagnostic methods, a thermal image analysis model is proposed in this work. Using a thermal image technique in diagnosis field is emerging in the various engineering field due to its non-contact, safe, and highly reliable energy detection technology. Deep learning object detection algorithms are trained with thermal images of a power distribution facility in order to automatically analyze its irregular energy status, hereby efficiently preventing fault of the system. The detected object is diagnosed through a thermal intensity area analysis. The proposed model in this work resulted 82% of accuracy of detecting an actual distribution system by analyzing more than 16,000 images of its thermal images.

A Fast Contingency Screening Algorithm for On-line Transient Security Assessment Based on Stability Index

  • Nam, Hae-Kon;Kim, Yong-Hak;Song, Sung-Geun;Kim, Yong-Gu
    • KIEE International Transactions on Power Engineering
    • /
    • 제2A권4호
    • /
    • pp.131-135
    • /
    • 2002
  • This paper describes a new ultra-fast contingency screening algorithm for on-line TSA without time simulation. All machines are represented in a classical model and the stability index is defined as the ratio between acceleration power during a fault and deceleration power after clearing the fault. Critical clustering of machines is done based on the stability index, and the power-angle curve of the critical machines is drawn assuming that the angles of the critical machines increase uniformly, while those of the non-critical ones remain constant. Finally, the critical clearing time (CCT) is computed using the power-angle curve. The proposed algorithm is tested on the KEPCO system comprised of 900-bus and 230-machines. The CCT values computed with the screening algorithm are in good agreement with those computed using the detailed model and the SIME method. The computation time for screening about 270 contingencies is 17 seconds with 1.2 GHz PC.

배전계통 광역 정전복구 알고리즘 개발 (The Development of Multi-Fault Restoration Algorithm for Distribution Network)

  • 정진수;이승재;정종욱;임용배;배석명;이건호
    • 조명전기설비학회논문지
    • /
    • 제20권3호
    • /
    • pp.69-77
    • /
    • 2006
  • 이 논문에서는 배전계통의 정전복구 알고리즘에 대해 연구하였다. 배전계통에서 정전이 발생하였을 경우, 그 피해를 최소화하기 위해 가능한 빠른 시간 내에 정전복구가 완료되어야 한다. 따라서, 본 논문에서는 광범위한 영역에 걸친 정전구간을 신속하게 복구하기 위한 2가지 방법을 연구하였다. 하나의 방안은 개별정전복구방안이며, 다른 하나는 종합정전복구방안이다. 이 방안은 복구지수를 이용하여 정전구간을 복구하는 것을 도와준다. 또한 연계점 교환법을 이용하여 과부하구간을 해소함으로써 정전복구에 일조하게 된다.

기존 전산 프로그램 연계에 의한 신뢰도 제어 운전 지원을 위한 전문가시스템 (An Expert System for Operational Aids of Security Control by Incorporation with Conventional Program Packages)

  • 문영현;최병윤;김세호
    • 대한전기학회논문지
    • /
    • 제39권3호
    • /
    • pp.240-246
    • /
    • 1990
  • The security control can be defined as all control actions and counter-measures to return the operating state of the system to a normal state. In an emergency state, fault clearing and/or overload suppression is enabled as a security control in order to prevent the extension of the fault. In the alert state, counter-measures should be set up in advance for the dangerous points of the system operation in drder to protect the system from expected accidents. In the normal state, the routine scenario is conducted to analyze system state. In the decision-making of the classification of system states, the heuristic and experienced knowledge can be well applied and thus application of expert system to this area attains considerable achievements. In this study, it is attempted to extract empirical rules through heuristic analysis and establish the knowledge base. Finally, the incorporation method with the conventional program packages in proposed. The expert system is designed to select an appropriate method and to perform the corresponding package. The input data can be automatically set up by using the data base. The computation results can be automatically added to the data base.

  • PDF

효율적인 센서 노드 고장 진단 알고리즘 (An Effective Algorithm for Diagnosing Sensor Node Faults)

  • 오원근;이성근
    • 한국전자통신학회논문지
    • /
    • 제10권2호
    • /
    • pp.283-288
    • /
    • 2015
  • 센서 네트웨크에서 센서 노드는 고장이나 전력 손실 등과 같은 다양한 원인에 의해 오작동 및 부정확한 데이터 전송의 가능성을 가지고 있으며, 이러한 센서 노드의 오류는 전체 네트워크의 신뢰성 있는 서비스에 지장을 줄 수 있다. 본 논문에서는 센서 노드 자체의 동작 오류를 줄이는 방안으로 다중센서를 사용한 센서 노드의 고장 진단과 데이터 처리 알고리즘을 제안하였다. 제안된 방법은 센서 노드에 다수의 센서를 사용하여 측정하고, 각 센서의 값을 비교하여 이상 유무를 판별하여 신뢰성 있는 데이터만을 전송하는 방식이다. 이 알고리즘은 센서의 수가 많아지는 단점이 있지만, 간단한 연산으로 센서 이상을 검출할 수 있는 방법이기 때문에 높은 신뢰도가 중요한 응용 분야에는 유용하게 사용될 수 있을 것이다.

도심지 변전소 지락사고시 인근 저항성간섭 영향 해석 (Analysis of Conductive Interference Around Substation Exclusively Fed by Cables Under Ground Fault Condition)

  • 최종기;이동일;김재준;유연표;정창수;김경철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권12호
    • /
    • pp.592-596
    • /
    • 2005
  • Recently, substations have been constructed in GIS (Gas Insulated Switchgear) and indoor type because of the increasing difficulties of securing locations. In case of urban substations, it is also common that the substations are exclusively fed by underground cables. Sometimes, the infrastructures in urban area, such as communication facilities, are located near substations to be constructed. In this paper, we examined such a case that a branch office building of KT(Korea Telecom) was located near 154 kV underground GIS substation under construction with about 100 meters of the lateral distance between two facilities. GPR (Ground Potential Rise) at the substation and the transferred earth potential at the KT building through the earth in SLG (Single-Line-to- Ground) fault condition were investigated based on a series of computer simulations. The calculated earth potential at a distance of 100 m from the substation was below 120 V which satisfying the limit value of 650 V.