• Title/Summary/Keyword: fatigue measurement

Search Result 460, Processing Time 0.03 seconds

Measurements of Whole-body Vibration Exposed from and Their UH60-helicopter Analysis Results (UH60 헬기 조종사의 피폭진동 측정 및 평가 결과)

  • Cheung, Wan-Sup;Byeon, Joo-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.12 s.105
    • /
    • pp.1327-1331
    • /
    • 2005
  • This Paper addresses what amount of whole-body vibration is exposed to Korean pilots of UH60 helicopters during their mission flight. To measure the expose4 whole-body vibration, the 12-axis whole-body vibration measurement system was used. It enables the direct measurement of whole-body vibration exposed from the body contact area consisting of the feet, hip and back. The measured 12-axis vibration signals were used to evaluate the vibration comfort level experienced by the pilots of UH60 helicopters. The evaluated vibration comfort level is found to be closeto 0.74-0.79m/s, which is equivalent to the semantic scale of 'fairly uncomfortable'. To assess the health effects of whole-body vibration exposed to Korean pilots of UH60 helicopters during their mission flight, the rms-based and VDV(vibration dose value)-based evaluation schemes, recommended by ISO 2631-1:1977, were exploited in this work. The evaluated results indicate that Korean pilots cannot avoid the fatigue-decreased proficiency limit after two-hour continuous flight. The whole-body vibration level exposed from the UH60 helicopters during continuous 10-hours mission flight is found to reach to the vibration exposure limit.

Durability of Corrugated Fiberboard Container for Fruit and Vegetables by Vibration Fatigue at Simulated Transportation Environment (모의 수송 환경에서의 청과물 골판지 상자의 진동 피로에 따른 내구성)

  • Kim M. S.;Jung H. M.;Kim K. B.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.2 s.109
    • /
    • pp.89-94
    • /
    • 2005
  • The compression strength of corrugated fiberboard container for packaging the agricultural products rapidly decreases because of various environmental conditions during distribution of unitized products. Among various environmental conditions, the main factors affecting the compression strength of corrugated fiberboard are absorption of moisture, long-term accumulative load, and fatigue caused by shock and vibration. An estimated rate of damage for fruit during distribution is about from 30 to 40 percent owing to the shock and vibration. This study was carried out to characterize the durability of corrugated fiberboard container for packaging the fruit and vegetables under simulated transportation environment. The vibration test system was constructed to simulate the land transportation using truck. After the package with corrugated fiberboard container was vibrated by vibration test system at various experimental conditions, the compression test for the package was performed. The compression strength of corrugated fiberboard container decreased with loading weight and vibrating time. The multiple nonlinear regression equation for predicting the decreasing rate of compression strength of corrugated fiberboard containers were developed using four independent variables such as input acceleration level, input frequency, loading weight and vibrating time. The influence of loading weight on the decreasing rate of corrugated fiberboard container was larger than other variables.

A Study on the Fatigue behavior of Plasma Sprayed Coating Layer and Fatigue Life Variation of Steel (플라즈마 용사층의 피로거동 및 강의 피로수명 변화에 관한 연구)

  • Park, M. H.;Han, J. C.;Jung, C.;Song, Y. S.;Lo, B. H.;Lee, K. H.
    • Journal of the Korean institute of surface engineering
    • /
    • v.31 no.2
    • /
    • pp.81-90
    • /
    • 1998
  • NiCrAly/YSZ(8wt% Y2O3-Zro2) functionally fraded thermal barrier coating (FGC) layers on a Co-base sureralloy (HAYNESS 188) substrate were fabricated using Ar shielded single torch air plasma spraying method. Functional grading were produced with the stepwise compositional change throughout layer thinkness. Microstructural observation revealed a sucessful fabrication of NiCrAly/YSZ FGC. From the results of the curvature measurement, adhesive stength measurement and thermal shock test for the FGC, it was concluded that the optimum enhance of functionally graded coating layer thinkcess and compositional pattern exit to enhance the properties of FGC, which is closely reated to the internal residual distribution with it.

  • PDF

The Relationship between Fatigue, Stress resistance and Emotion in Korean middle aged women (중년여성의 피로와 스트레스 저항력 그리고 정서와의 관계 연구)

  • Lee, Jung-Eun;Park, Pyung-Woon;Hyun, Kyung-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.3
    • /
    • pp.1145-1150
    • /
    • 2011
  • The purpose of this study was to determine the relationships between fatigue, stress resistance and emotion in middle aged women under the developmental crisis using a brain wave measurement which is a cranial physiological index. From March 2005 to June 2009, women aged between 35 and 65 (N=4402) who volunteered for a brain wave test at the KRIJUS( Korea Research Institute of Jungshin Science) were monitored the brain function quotient (tension degree, anti-stress quotient and emotional quotient). Correlation and time-series linear analysis revealed significantly the relationships between fatigue, stress resistance and emotion. Also, according to the emotional propensity, cheerful propensity was higher in the cheerful and depressed propensity, positive propensity was higher in the positive and negative propensity, during the whole test, cheerful and positive propensity was higher. Therefore, it is necessary to increase the quality of life by decreasing fatigue and stress level of the middle-aged women to maintain and increase their individual health and the better family relationship.

A Comparative Study for the Fatigue Assessment of fillet Weldments Using Structural Stress and Hot Spot Stress (필릿 용접구조물의 피로해석을 위한 기준응력에 대한 비교 연구 -구조응력 및 핫스팟응력-)

  • Ha Chung-In;Kang Sung-Won;Kim Man-Soo;Sohn Sang-Yong;Heo Joo-Ho;Kim Myung-Hyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.43 no.4 s.148
    • /
    • pp.476-483
    • /
    • 2006
  • Fatigue strength assessments with two types of load carrying fillet weldment under out-of-plane bending load have been carried out by using both hot spot stress and structural stress methods. In this study, a derivation for the structural stress method using shell element models is discussed in detail. Finite element analysis using shell element models have been performed for the assessment of fatigue strength. As a result of the fatigue strength evaluation for load carrying transverse fillet weldment, hot spot stress method is found to be consistent with structural stress method and measurement. Hot spot stress, however, estimated for the load carrying longitudinal fillet weldment exhibit large variation with respect to mesh size and element type while the calculated structural stress for the longitudinal fillet weldment is relatively independent of mesh size. On the other hand, drawbacks and doubts associated with applying the structural stress method such as the guidance of virtual node method have been discussed.

Detection and Sizing of Fatigue Cracks in Thin Aluminum Panel with Rivet Holes (리벳구멍을 가진 알루미늄 패널에서 피로균열의 탐지와 균열길이 측정)

  • Kim, Jung-Chan;Kwon, Oh-Yang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.1
    • /
    • pp.38-47
    • /
    • 2007
  • The initiation of fatigue cracks in a simulated aircraft structure with a series of rivet holes was detected by acoustic emission(AE), then the crack length was determined by surface acoustic wave(SAW) technique. With the initiation and growth of fatigue cracks, AE events increased intermittently to form a stepwise incremental curve of cumulative AE events whereas the crack length increased more or less monotonically. With the SAW technique employed, the crack sizing for 13 different cracks including some short cracks was performed. With the reference to the measurement by traveling microscope, cracks in the range of $1{\sim}8mm$ long were reliably sized by the SAW technique. Although it was impossible to size the short fatigue cracks in the range shorter than 1 mm, the SAW technique still appeared practically useful for a range of crack lengths often found in aircraft structures.

The Effect of Fatigue of Patients with Chronic Obstructive Pulmonary Disease on Depression and The Health-Related Quality of Life (만성폐쇄성폐질환환자의 피로도가 우울정도와 건강관련 삶의 질에 미치는 영향)

  • Kang, Jeong-Il;Jeong, Dae-Keun;Choi, Hyun
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.4
    • /
    • pp.262-268
    • /
    • 2014
  • Purpose: This study was conducted in order to measure fatigue as an objective index, depression and health-related quality of life of patients with COPD in daily life, to understand the correlation between them, and to present reasons for using the results clinically. Methods: This study is intended to evaluate and compare depression, the health-related quality of life of each group after measuring lactic acid levels of 39 male patients with COPD, and dividing those with measurement values than the normal value into the experimental group, and those with normal values into the control group. Results: When comparing depression between the experimental group and the control group, it was measured at 10.38 in the experimental group, and at 7.00 in the control group (p<0.05). Health-related quality of life between the experimental group and the control group was measured at 51.8 in the experimental group, and at 48.67 in the control group (p>0.05). Conclusion: According to the results described above, it appears that patients with COPD have adapted to their disease in some degree for a long period of time, and they are physically and psychologically adjusting to the fatigue they experience, in their own ways of adapting. These results imply that improving physical activity is associated with relief of fatigue and improvement of the quality of life. Thus, there is a need for developing and researching an exercise program and a physical therapy intervention for enhancement of physical activity.

Detection of Fatigue Damage in Aluminum Thin Plates with Rivet Holes by Acoustic Emission (리벳 구멍을 가진 알루미늄 박판구조의 피로손상 탐지를 위한 음향방출의 활용)

  • Kim, Jung-Chan;Kim, Sung-Jin;Kwon, Oh-Yang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.3
    • /
    • pp.246-253
    • /
    • 2003
  • The initiation and growth of short fatigue cracks in the simulated aircraft structure with a series of rivet holes was detected by acoustic emission (AE). The location and the size of short tracks were determined by AE source location techniques and the measurement with traveling microscope. AE events increased intermittently with the initiation and growth of short cracks to form a stepwise increment curve of cumulative AE events. For the precise determination of AE source locations, a region-of-interest (ROI) was set around the rivet holes based on the plastic zone size in fracture mechanics. Since the signal-to-noise ratio (SNR) was very low at this early stage of fatigue cracks, the accuracy of source location was also enhanced by the wavelet transform do-noising. In practice, the majority of AE signals detected within the ROI appeared to be noise from various origins. The results showed that the effort of structural geometry and SNR should be closely taken into consideration for the accurate evaluation of fatigue damage in the structure.

Effect of internal stress on cyclic fatigue failure in .06 taper ProFile (내부 응력이 .06 taper ProFile의 피로 파절에 미치는 영향)

  • Jung, Hye-Rim;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.2
    • /
    • pp.79-83
    • /
    • 2012
  • Objectives: The purpose of this study was to evaluate the relation between intentionally induced internal stress and cyclic fatigue failure of .06 taper ProFile. Materials and Methods: Length 25 mm, .06 taper ProFile (Dentsply Maillefer), and size 20, 25, 30, 35 and 40 were used in this study. To give the internal stress, the rotary NiTi files were put into the .02 taper, Endo-Training-Bloc (Dentsply Maillefer) until auto-stop by torque controlled motor. Rotary NiTi files were grouped by the number of induced internal stress and randomly distributed among one control group and three experimental groups (n = 10, Stress 0 [control], Stress 1, Stress 2 and Stress 3). For cyclic fatigue measurement, time for separation of the rotary NiTi files was recorded. The fractured surfaces were observed by field emission scanning electron microscope (FE-SEM, SU-70, Hitachi). The time for separation was statistically analyzed using two-way ANOVA and post-hoc Scheffe test at 95% level. Results: In .06 taper ProFile size 20, 25, 30, 35 and 40, there were statistically significant difference on time for separation between control group and the other groups (p < 0.05). Conclusion: In the limitation of this study, cyclic fatigue failure of .06 taper ProFile is influenced by internal stress accumulated in the files.

Usefulness of Vocal Fatigue Index for Hypertension of Extrinsic Laryngeal Muscles (후두외근 과긴장에 대한 음성피로도 검사의 유용성)

  • Kim, Ji-Sung;Lee, Dong-Wook
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.32 no.3
    • /
    • pp.124-129
    • /
    • 2021
  • Background and Objectives This study compares Vocal Fatigue Index (VFI) scores according to the presence or absence of external laryngeal tension in hyperfunctional voice disorder. And through this, it is to confirm the usefulness of VFI to hypertension of extrinsic laryngeal muscles. Materials and Method The subjects were 61 female diagnosed with hyperfunctional voice disorder (hypertension group 41, non-hypertension group 20). The author palpated extrinsic laryngeal muscles for evaluation of hypertension and classified them as the presence or absence. The voice measurements were jitter, shimmer, Korean-Voice Handicap Index-10 (K-VHI-10), and Korean-Vocal Fatigue Index (K-VFI). The voice compared were according to the diagnosis and presence of hypertension only for patients with hyperfunctional voice disorder. Results As a result of comparing the voice measurement according to the presence or absence of hypertension, there was no significant difference in the acoustic variables, K-VHI-10 and K-VFI-Total, K-VFI-Fatigue. Whereas, K-VFI-Physical (p=0.006) and K-VFI-Rest (p=0.022) were significantly higher in the hypertension group. Conclusion These results indicate that the hypertension group has more physical discomfort and less voice recovery than the group without hypertension. It means that K-VFI can measure the physical discomfort and limitations of voice recovery due to hypertension of the external laryngeal muscle. The VFI can be used as one of the methods to evaluate the hypertension of the external laryngeal muscle in Hyperfunctional voice disorder.