• Title/Summary/Keyword: fat measurement

Search Result 431, Processing Time 0.027 seconds

Sarcopenia and Age-Related Changes in Body Composition in Korean Older Persons

  • Im, Jee-Aee;Kim, Sang-Hwan;Lim, Hee-Jung;Kim, Chang-Hee;Suh, Sang-Hoon
    • Biomedical Science Letters
    • /
    • v.14 no.1
    • /
    • pp.7-12
    • /
    • 2008
  • We examined the prevalence of sarcopenia and age-related changes in body composition in Korean older persons. Community dwelling 77 men and 65 women($60{\sim}88\;yr$) were recruited for this study. Fat-free mass and the percent body fat were determined using bioelectrical impedance analysis. Isometric grip strength was measurement using grip strength dynamometer. Serum levels of fasting glucose, total cholesterol, HDL-cholesterol, and triglyceride were assayed. The prevalence of sarcopenia was found to increase with aging (men in their sixties 82.6%, seventies 96.6% and eighties 100%, and women in their sixties 47.4%, seventies 63%). In both gender groups, handgrip strength was inversely correlated with age and positively correlated with height, lean mass, and fat free mass. Better handgrip strength was related with higher weight in the men and with lower heart rate in the women. Fat free mass, age, and gender were found to be independent factors significantly associated with handgrip strength in the multivariate analysis. In summary, results of the present study suggest that handgrip strength is well associated with age, gender, and fat free mass and the prevalence of sarcopenia is increased with age and is exceeded by 40% among Korean persons older than 60 years.

  • PDF

A Study on The Fat Measurement at Subcutaneous Adipose by Optical and Electrical Method (광전 방식에 의한 피하 지방층의 비만도 측정에 관한 연구)

  • Oh, Se-Yong;Lee, Young-Woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.6
    • /
    • pp.1070-1074
    • /
    • 2008
  • Body fat correlation formula induced by using optical method was used white light LED source and electrical method used BIA(Bio-electrical Impedance Analysis) method measured at same time. In the case of BIA method confirmed phase difference of 6 degree and voltage drop of 2.7V at 5V and 50kHz's input signal. In the case of optical method confirmed that optical intensity increased by order of the biceps, the fleshy inside of the thigh and the triceps. We obtained percent body fat of 20% with the body fat correlation formula induced by photo-electricity method.

Evaluation of BMI as an Obesity Index for Korean

  • Kim, Youngok;Lee, Soon-Young;Kim, Seon-Woo;Kim, Kyung-Hee
    • Journal of Community Nutrition
    • /
    • v.2 no.2
    • /
    • pp.129-134
    • /
    • 2000
  • The purpose of the present study is to evaluate the validity of the BMI as an indicator of obesity for Koreans. The usefulness of the BMI to represent overweight and obesity was evaluated by measuring the relative validity of sensitivity and specificity, and was compared with the validity of triceps skinfold thickness(mm). To measure the relative validity of the BMI and triceps skinfold thickness, body fat(%) was used as a reference measure of obesity. The study population included 844 participants aged 20-69 years who resided in Kuri City in Kyunggi province. Participants were measured regarding weight, height, triceps skinfold thickness and body fat. The prevalence of obesity for male subjects was 32.0%, 66.2%, and 0.9%, and for female subjects, 17.6%, 56.1%, 12.4% based on the BMI, triceps skinfold thickness, and body fat(%) respectively. The prevalence of obesity was higher based on the BMI or triceps skinfold thickness than body fat measurement. The sensitivity and specificity of the BMI were 33.3% and 67.9% in male subjects and 77.7% and 90.8% in female subjects. Sensitivity of the BMI was lower, and specificity was higher than those of triceps skinfold thickness. In summary, BMI as an indicator of obesity for Korean showed a tendency of overestimation of obesity prevalence. Therefore, there is a need to develop a more reliable obesity index other than the BMI for Koreans.

  • PDF

Weight Gain Due to Abdominal Mass Misdiagnosed as Obesity: Case Report (복부종괴로 인한 체중증가를 비만으로 오인한 2개의 증례)

  • Sun-Hyun Kim
    • Archives of Obesity and Metabolism
    • /
    • v.2 no.1
    • /
    • pp.25-28
    • /
    • 2023
  • Early evaluation of obesity is important. Obesity is defined as an excessive accumulation of fat that causes harm to health. Among patients who visit a hospital for weight-related issues, diseases other than body fat gain may be present; however, people often cannot distinguish between these issues and concerns. Therefore, among patients who visit the hospital with weight gain concerns, it is necessary to determine whether the weight gain is actually the result of excessive fat accumulation. After being diagnosed with obesity, the cause and degree of obesity, the amount and distribution of body fat, and the degree of risk should be evaluated. Additionally, obesity-related complications should be identified and, even if there are no complications, all related risk factors should be evaluated and managed. In all these processes, diagnostic methods such as history taking, physical examination, body fat measurement, blood tests, and imaging tests are necessary, but history taking and physical examination, which can provide a lot of information from the beginning, should not be overlooked.

Miniaturization of Ultra Wideband Log-Periodic Dipole Antenna for Leaked Electromagnetic Measurement (누설전자파 측정을 위한 초광대역 로그주기 안테나의 소형화)

  • Choi, Dong-Hoon;Kim, Tae-Hyung;Moon, Jun-Ho;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.10
    • /
    • pp.761-768
    • /
    • 2017
  • In this paper, to implement the electromagnetic wave environment and solve electromagnetic compatibility(EMC) problem, miniaturization of ultra-wide band log periodic dipole antenna for measurement was investigated. In addition, in oder to improve the signal-to-noise ratio in high frequency band, balun was connected to the antenna to stabilize the operation of the differential mode antenna and the single mode coaxial cable. To minimize the total size and to increase bandwidth of the antenna, a fat dipole structure was used for the resonance frequency band below 4 GHz and a general dipole shape was used for that above 4 GHz. The bandwidth of the proposed antenna was represented from 0.6 GHz to 8.0 GHz with a ratio bandwidth of 12.3 : 1. Measured peak gain varies from 5.7 dBi to 9.1 dBi, and a half power beamwidth was presented from $29.4^{\circ}$ to $100.2^{\circ}$ in operating range.

Uncertainty of Peroxide Value Determination in Fat in Follow up Formula (성장기용 조제식에 함유된 유지성분의 과산화물가 측정불확도)

  • Kim, Sung-Han;Kwack, Byung-Man;Ahn, Jang-Hyuk;Kong, Un-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.885-892
    • /
    • 2004
  • Peroxide values (PV) of fat from fallow up formula were determined using redox-potentiometric titration method and standard method, which is based on KI oxidation by hydroperoxides and volumetric titration of liberated iodine, and their uncertainties were compared. Uncertainty sources in measurement, such as sample weight, sodium thiosulfate concentration, and titer, were identified and used as parameters for combined standard uncertainty based on Guide to the expression of uncertainty in measurement and Draft EURACHEM/CITAC Guide. Analytical results and combined standard uncertainties of peroxide values (PV) determined by standard burette and potentiometric titrations were $2.05{\pm}0.17\;and\;1.96{\pm}0.07\;meq/kg$, respectively, suggesting potentiometric titration method is suitable for determining PV of fat with low PV, because uncertainty of PV determination obtained by potentiometric titration was lower than that obtained by burette titration.

Measurement of Fat Content in Potatochips by Near-infrared Spectroscopy (근적외선 분광 분석법에 의한 감자칩의 지방 함량 측정)

  • Bae, Young-Min;Cho, Seong-In;Chun, Jae-Geun
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.916-921
    • /
    • 1996
  • This study was conducted to measure fat contents of potatochips by near infrared spectroscopy (NIRS). Both potatochip powder and potatochips were used to find correlations between the absorbance at certain wavelengths find the fat contents. Based on the correlation analysis, linear regression models predicting the fat contents were developed to predict the fat contents. Artificial neural network (ANN) models were also developed. Predicted values were compared to the measured ones. The regression and the ANN model predicting the fat contents of potatochip powder had determination coefficients of 0.93 and 0.92, and standard errors of prediction (SEP) of 1.29% and 1.17%, respectively. The correlation analysis of potatochips showed that the determination coefficients were low. Therefore, the fat contents of not potatochips but potatochip powder could be measured by NIRS.

  • PDF

The Effectiveness of 448-kHz Capacitive Resistive Monopolar Radiofrequency for Subcutaneous Fat Reduction in a Porcine Model

  • Kwon, Tae-Rin;Lee, Sung-Eun;Kim, Jong Hwan;Jeon, Yong Jae;Jang, You Na;Yoo, Kwang Ho;Kim, Beom Joon
    • Medical Lasers
    • /
    • v.8 no.2
    • /
    • pp.64-73
    • /
    • 2019
  • Background and Objectives The effectiveness of many physiotherapy modalities in reducing subcutaneous fat has been investigated in numerous previous studies. However, to the best of our knowledge, there have been no attempts to determine the effectiveness of physiotherapy modalities in body contouring. The present report determined the effect of 448-kHz capacitive resistive monopolar radiofrequency (CRMRF) in a porcine model. Materials and Methods This study investigated the effect of selective destruction of the subcutaneous fat layer in abdominal fat tissue using CRMRF. The effects of two types of CRMRF (capacitive electric transfer (CET) and resistive electric transfer (RET)) treatment were evaluated using regular digital photography in addition to thermal imaging evaluation, ultrasound measurement, hematological evaluation, and histologic analyses (H&E (hematoxylin and eosin), Oil red O, and immunohistochemistry staining). Results Preclinical evaluation was performed to obtain the data for comparison of the safety and efficacy of the subcutaneous fat reduction after applying CRMRF using CET and RET. After treatment, the thermal transmission was effective, and a 42-47℃ temperature change was observed in the fat layer while an approximately temperature of 42℃ was confirmed on the skin surface. Moreover, after the application of both types of CRMRF treatment, fibrotic septa were observed in the adipose tissue induced by heat at the treatment sites. TUNEL staining was also performed to confirm the process of apoptosis in the adipocytes. Conclusion These results suggest that both CET and RET for CRMRF treatment are safe and effective for subcutaneous fat reduction in a porcine model.

Cryptotanshinone promotes brown fat activity by AMPK activation to inhibit obesity

  • Jie Ni;Aili Ye;Liya Gong;Xiafei Zhao;Sisi Fu;Jieya Guo
    • Nutrition Research and Practice
    • /
    • v.18 no.4
    • /
    • pp.479-497
    • /
    • 2024
  • BACKGROUND/OBJECTIVES: Activating brown adipose tissue (BAT) and browning of white adipose tissue (WAT) can protect against obesity and obesity-related metabolic conditions. Cryptotanshinone (CT) regulates lipid metabolism and significantly ameliorates insulin resistance. Adenosine-5'-monophosphate (AMP)-activated protein kinase (AMPK), a receptor for cellular energy metabolism, is believed to regulate brown fat activity in humans. MATERIALS/METHODS: The in vivo study included high-fat-fed obese mice administered orally 200/400 mg/kg/d CT. They were evaluated through weight measurement, the intraperitoneal glucose tolerance test (IPGTT), intraperitoneal insulin tolerance test (IPITT), cold stimulation test, serum lipid (total cholesterol, triglycerides, and low-density lipoprotein) measurement, hematoxylin and eosin staining, and immunohistochemistry. Furthermore, the in vitro study investigated primary adipose mesenchymal stem cells (MSCs) with incubation of CT and AMPK agonists (acadesine)/inhibitor (Compound C). Cells were evaluated using Oil Red O staining, Alizarin red staining, flow cytometry, and immunofluorescence staining to identify and observe the osteogenic versus adipogenic differentiation. Quantitative real-time polymerase chain reaction and the Western blot were used to observe related gene expression. RESULTS: In the diet-induced obesity mouse model mice CT suppressed body weight, food intake, glucose levels in the IPGTT and IPTT, serum lipids, the volume of adipose tissue, and increased thermogenesis, uncoupling protein 1, and the AMPK pathway expression. In the in vitro study, CT prevented the formation of lipid droplets from MSCs while activating brown genes and the AMPK pathway. AMPK activator enhanced CT's effects, while the AMPK inhibitor reversed the effects of CT. CONCLUSION: CT promotes adipose tissue browning to increase body thermogenesis and reduce obesity by activating the AMPK pathway. This study provides an experimental foundation for the use of CT in obesity treatment.

Development of the PDA Based Mobile System for Body Fat Measurement and Diagnosis Using Bioelectrical Impedance Method (체임피던스 방법을 이용한 PDA 기반의 휴대용 체지방 측정 및 진단 시스템 개발)

  • 권세윤;이상민;김재환;우지환;김인영;이형기;방석원;김선일
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.21-26
    • /
    • 2004
  • Recently, many people want to know their state of health, such as a body fat rate, anywhere and anytime. The Personal Digital Assistance(PDA) is the portable wireless apparatus that has become widely popular. There are many application areas of the IDA to be in mobile care devices. In this study, we developed the PDA based body fat measurement system, composed of a cradle type measurement module and a WindowCE operated software module, a regression equation for predicting lean body mass (LBM). Sixty-three weight-stable subjects (53 men, 10 women) aged 20∼32yr participated in this study. A regression model, LBM = (0.0005*Height2 - 0.0160*Impedance + 0.3920*Weight - 0.0684*Age - 5.8141*Sex + 25.984, was found. The correlation coefficient( r) of body fat rate between developed system and HTM1000plus(BionetTM) was 0.928. HTM1000plus is a commercially available and approved by KFDA. These results indicated that developed system is reliable for estimation of body fat rate. Although developed system is the PDA based miniaturized, it shows good performance comparing with other commercial product.