• Title/Summary/Keyword: fast screening

Search Result 131, Processing Time 0.03 seconds

A Contingency Screening Algorithm Using SIME for Transient Stability Assessment of the KEPCO System

  • Lee, J.;Lee, B.;Kwon, S.H.;Nam, H.K.;Ahn, T.;Choo, J.B.;Yi, K.
    • Journal of KIEE
    • /
    • v.11 no.1
    • /
    • pp.55-61
    • /
    • 2001
  • SIME(Single Machine Equivalent) method has been recognized as a useful tool to determine transient stability of power system. In this paper, SIME method is used to develop the KEPCO transient stability assessment (TSA) tool. A new screening algorithm that can be generators are identified by a new index in the early stage of the time domain simulation. Thus, computational time require to find OMIB(One Machine Infinite Bus) can be reduced significantly. Second, clustering critical machines can be performed even in very stable cases. It enables to be avoid extra calculation of time trajectory that is needed in SIME for classifying the stable cases. This algorithm is applied to the fast TSA of the KEPCO system in the year of 2010.

  • PDF

Pre-immigration Screening for Tuberculosis in South Korea: A Comparison of Smear- and Culture-Based Protocols

  • Lee, Sangyoon;Ryu, Ji Young;Kim, Dae-Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.82 no.2
    • /
    • pp.151-157
    • /
    • 2019
  • Background: Tuberculosis (TB) is the most important disease screened for upon patient history review during preimmigration medical examinations as performed in South Korea in prospective immigrants to certain Western countries. In 2007, the U.S. Centers for Disease Control and Prevention (CDC) changed the TB screening protocol from a smear-based test to the complete Culture and Directly Observed Therapy Tuberculosis Technical Instructions (CDOT TB TI) for reducing the incidence of TB in foreign-born immigrants. Methods: This study evaluated the effect of the revised (as compared with the old) protocol in South Korea. Results: Of the 40,558 visa applicants, 365 exhibited chest radiographic results suggestive of active or inactive TB, and 351 underwent sputum tests (acid-fast bacilli smear and Mycobacterium tuberculosis culture). To this end, using the CDOT TB TI, 36 subjects (88.8 per $10^5$ of the population) were found to have TB, compared with only seven using the older U.S. CDC technical instruction (TI) (p<0.001). In addition, there were six drug-resistant cases which were identified (16.7 per $10^5$ of the population), two of whom had multidrug-resistance (5.6 per $10^5$ of the population). Conclusion: The culture-based 2007 TI identified a great deal of TB cases current to the individuals tested, as compared to older U.S. CDC TI.

FAST Reappraisal: Cross-sectional Study (혈역학적으로 안정된 복부둔상환자에서 FAST의 유용성 평가)

  • Ha, Sang Hyun;Hong, Chong Kun;Lee, Jun Ho;Hwang, Seong Youn;Choi, Seong Hee
    • Journal of Trauma and Injury
    • /
    • v.25 no.3
    • /
    • pp.67-71
    • /
    • 2012
  • Purpose: Focused Assessment with Sonography for Trauma (FAST) provides an important initial screening examination in adult trauma patients. However, due to its low sensitivity, FAST is not a replacement for computed tomography (CT) in hemodynamically stable trauma patients. The aim of this study was to determine the test characteristics of FAST in adult, hemodynamically stable, blunt abdominal trauma patients by using a critical action as a reference standard. Methods: The medical records for FAST examination at a single hospital from January 2009 to February 2011 were retrospectively reviewed. The inclusion criterion was isolated, hemodynamically stable, blunt abdominal trauma. Hemodynamically unstable patients or patients with penetrating injuries were excluded. The reference standard was the presence of a critical action, which was defined as one of the following: 1) operative intervention for a finding discovered on CT, 2) interventional radiology for bleeding, 3) transfusion of 2 or more packed RBCs, or 4) death at the emergency department. Results: There were 230 patients who met the inclusion criterion. There were 20 true positive, 206 true negative, 0 false positive, and 4 false negative results. The sensitivity and the specificity were 83% and 100%, respectively. Conclusion: Despite its low sensitivity for detecting any abnormal finding discovered on CT, negative FAST could aid to exclude critical action in hemodynamically stable, blunt abdominal trauma patients.

Multiplex PCR for Detection of Quinolone Resistance qnr Genes in Extended-Spectrum β-Lactamase Producing Escherichia coli and Klebsiella pneumoniae (Multiplex PCR을 이용한 Extended-Spectrum β-Lactamase 생성 Escherichia coli와 Klebsiella pneumoniae의 Quinolone 내성 qnr유전자 검출)

  • Yang, Byoung-Seon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.3
    • /
    • pp.161-166
    • /
    • 2007
  • To develop a rapid and reliable single-tube-based PCR technique for detection simultaneously the quinolone resistance qnrA, qnrB and qnrS genes. After multiple alignment, primers were designed to detect known qnr variants. I was used for A total of 43 extented-spectrum ${\beta}$-lactamases (ESBLs) producing Escherichia coli and Klebsiella pneumoniae isolated from university hospital were tested for screening, as with qnr genes. In optimized conditions, all positive controls confirmed the specificity of the PCR primers. Out of 43 isolates, qnrA genes were detected 19 (44.2%), qnrB genes 5 (11.7%), qnrS genes 15 (34.9%) and 8 (18.6%) isolates were not detected. I report here a fast and reliable technique for rapid screening of qnr positive strains to be used for epidemiological surveys.

  • PDF

A Fast Screening Algorithm for On-Line Transient Stability Assessment (온라인 과도안정도 판정을 위한 상정사고 고속 스크리닝 알고리즘 개발)

  • Yang, Jung-Dae;Lee, Jong-Seock;Lee, Byung-Jun;Kwon, Sae-Hyuk;Lee, Koung-Guk
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.104-106
    • /
    • 2000
  • Transient Stability of a power systems is its ability to maintain synchronous operation of machine when subjected to a large disturbance. This paper presents a new methodology for speed-up transient stability evaluation in SIME. SIME is a hybrid direct method including time simulation to enhance flexibility. The First features of the proposed method are that generator grouping can be performed even in very stable cases and that the stability of a contingency can be evaluated from a short period of time simulation results. The second features of the proposed method are that using power-angle trajectory and subdividing contingency classification have improved the screening capability.

  • PDF

siMacro: A Fast and Easy Data Processing Tool for Cell-Based Genomewide siRNA Screens

  • Singh, Nitin Kumar;Seo, Bo Yeun;Vidyasagar, Mathukumalli;White, Michael A.;Kim, Hyun Seok
    • Genomics & Informatics
    • /
    • v.11 no.1
    • /
    • pp.55-57
    • /
    • 2013
  • Growing numbers of studies employ cell line-based systematic short interfering RNA (siRNA) screens to study gene functions and to identify drug targets. As multiple sources of variations that are unique to siRNA screens exist, there is a growing demand for a computational tool that generates normalized values and standardized scores. However, only a few tools have been available so far with limited usability. Here, we present siMacro, a fast and easy-to-use Microsoft Office Excel-based tool with a graphic user interface, designed to process single-condition or two-condition synthetic screen datasets. siMacro normalizes position and batch effects, censors outlier samples, and calculates Z-scores and robust Z-scores, with a spreadsheet output of >120,000 samples in under 1 minute.

A Idea Development Method for Process Innovation (경영혁신을 위한 과제 도출 방안)

  • Kim, Seong-Su
    • 한국디지털정책학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.289-297
    • /
    • 2006
  • Business operates under the fast pace of large-scale changes. These changes occur in environments including competitors, markets and consumers. To survive under these changes, process innovation is becoming the eminent issue faced by executives. Process innovation is to generate, select, and implement new ideas adopting changes in organizational structure, management pattern, human resource management systems and so on. Examples include restructuring, outsourcing, benchmarking, total quality management, and business process reengineering. This study suggests how to develop process innovation ideas. Related screening and implementation techniques are also presented.

  • PDF

A Rapid and Efficient Screening Method for Antibacterial Compound-Producing Bacteria

  • Hettiarachchi, Sachithra Amarin;Lee, Su-Jin;Lee, Youngdeuk;Kwon, Young-Kyung;Zoysa, Mahanama De;Moon, Song;Jo, Eunyoung;Kim, Taeho;Kang, Do-Hyung;Heo, Soo-Jin;Oh, Chulhong
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.8
    • /
    • pp.1441-1448
    • /
    • 2017
  • Antibacterial compounds are widely used in the treatment of human and animal diseases. The overuse of antibiotics has led to a rapid rise in the prevalence of drug-resistant bacteria, making the development of new antibacterial compounds essential. This study focused on developing a fast and easy method for identifying marine bacteria that produce antibiotic compounds. Eight randomly selected marine target bacterial species (Agrococcus terreus, Bacillus algicola, Mesoflavibacter zeaxanthinifaciens, Pseudoalteromonas flavipulchra, P. peptidolytica, P. piscicida, P. rubra, and Zunongwangia atlantica) were tested for production of antibacterial compounds against four strains of test bacteria (B. cereus, B. subtilis, Halomonas smyrnensis, and Vibrio alginolyticus). Colony picking was used as the primary screening method. Clear zones were observed around colonies of P. flavipulchra, P. peptidolytica, P. piscicida, and P. rubra tested against B. cereus, B. subtilis, and H. smyrnensis. The efficiency of colony scraping and broth culture methods for antimicrobial compound extraction was also compared using a disk diffusion assay. P. peptidolytica, P. piscicida, and P. rubra showed antagonistic activity against H. smyrnensis, B. cereus, and B. subtilis, respectively, only in the colony scraping method. Our results show that colony picking and colony scraping are effective, quick, and easy methods of screening for antibacterial compound-producing bacteria.

Study on the screening method for determination of heavy metals in cellular phone for the restrictions on the use of certain hazardous substances (RoHS) (유해물질 규제법(RoHS)에 따른 휴대폰 내의 중금속 함유량 측정을 위한 스크리닝법 연구)

  • Kim, Y.H.;Lee, J.S.;Lim, H.B.
    • Analytical Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.1-14
    • /
    • 2010
  • It is of importance that all countries in worldwide, including EU and China, have adopted the Restrictions on the use of certain Hazardous Substances (RoHS) for all electronics. IEC62321 document, which was published by the International Electronics Committee (IEC) can have conflicts with the standards in the market. On the contrary Publicly Accessible Specification (PAS) for sampling published by IEC TC111 can be adopted for complementary application. In this work, we tried to find a route to disassemble and disjoint cellular phone sample, based on PAS and compare the screening methods available in the market. For this work, the cellular phone produced in 2001, before the regulation was born, was chosen for better detection. Although X-ray Fluorescence (XRF) showed excellent performance for screening, fast and easy handling, it can give information on the surface, not the bulk, and have some limitations due to significant matrix interference and lack of variety of standards for quantification. It means that screening with XRF sometimes requires supplementary tool. There are several techniques available in the market of analytical instruments. Laser ablation (LA) ICP-MS, energy dispersive (ED) XRF and scanning electron microscope (SEM)-energy dispersive X-ray (EDX) were demonstrated for screening a cellular phone. For quantitative determination, graphite furnace atomic absorption spectrometry (GF-AAS) was employed. Experimental results for Pb in a battery showed large difference in analytical results in between XRF and GF-AAS, i.e., 0.92% and 5.67%, respectively. In addition, the standard deviation of XRF was extremely large in the range of 23-168%, compared with that in the range of 1.9-92.3% for LA-ICP-MS. In conclusion, GF-AAS was required for quantitative analysis although EDX was used for screening. In this work, it was proved that LA-ICP-MS can be used as a screening method for fast analysis to determine hazardous elements in electrical products.

Fast block matching algorithm for constrained one-bit transform-based motion estimation using binomial distribution (이항 분포를 이용한 제한된 1비트 변환 움직임 예측의 고속 블록 정합 알고리즘)

  • Park, Han-Jin;Choi, Chang-Ryoul;Jeong, Je-Chang
    • Journal of Broadcast Engineering
    • /
    • v.16 no.5
    • /
    • pp.861-872
    • /
    • 2011
  • Many fast block-matching algorithms (BMAs) in motion estimation field reduce computational complexity by screening the number of checking points. Although many fast BMAs reduce computations, sometimes they should endure matching errors in comparison with full-search algorithm (FSA). In this paper, a novel fast BMA for constrained one-bit transform (C1BT)-based motion estimation is proposed in order to decrease the calculations of the block distortion measure. Unlike the classical fast BMAs, the proposed algorithm shows a new approach to reduce computations. It utilizes the binomial distribution based on the characteristic of binary plane which is composed of only two elements: 0 and 1. Experimental results show that the proposed algorithm keeps its peak signal-to-noise ratio (PSNR) performance very close to the FSA-C1BT while the computation complexity is reduced considerably.