• 제목/요약/키워드: fast dynamics

검색결과 389건 처리시간 0.028초

Cancelling Magnetic Features on the Sun

  • 박소영;채종철
    • 천문학회보
    • /
    • 제36권1호
    • /
    • pp.36.2-36.2
    • /
    • 2011
  • A cancelling magnetic feature (CMF) is believed to be a result of magnetic reconnection in the low atmosphere of the Sun. In this work, we investigate the physical properties of CMFs, focusing on the rates of flux cancellation in CMFs and the dynamics of chromospheric phenomena coupled with CMFs. First, we have determined the specific rates of flux cancellation using the magnetograms taken by the Solar Optical Telescope (SOT) aboard the Hinode satellite. The specific rates determined with the SOT turned out to be systematically higher than those based on the data taken by the Michelson Doppler Imager (MDI) aborad the SOHO. Second, we analyzed transient Ca II brightenings associated with small-scale CMFs using the SOT/Hinode. We found that in most Ca II brightenings related to CMFs, and the Ca II intensity peaks after magnetic flux cancellation proceeds. Moreover, brightenings tend to appear as pairs of bright points of similar size and similar brightness overlying magnetic bipoles. To further study the brightening and dynamics of chromospherie features associated with CMFs, we have analyzed Fast Imaging Solar Spectrograph (FISS) data. From this data the Doppler motion of chromospheric features above a CMF changed from redshift to blueshift. The duration of such dynamics is very short being less than 2 minutes. These results are unexpected one and can not be explained by any pre-existing pictures of CMFs.

  • PDF

Rotor dynamic analysis of a tidal turbine considering fluid-structure interaction under shear flow and waves

  • Lass, Andre;Schilling, Matti;Kumar, Jitendra;Wurm, Frank-Hendrik
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제11권1호
    • /
    • pp.154-164
    • /
    • 2019
  • A rotor dynamic analysis is mandatory for stability and design optimization of submerged propellers and turbines. An accurate simulation requires a proper consideration of fluid-induced reaction forces. This paper presents a bi-directional coupling of a bond graph method solver and an unsteady vortex lattice method solver where the former is used to model the rotor dynamics of the power train and the latter is used to predict transient hydrodynamic forces. Due to solver coupling, determination of hydrodynamic coefficients is obsolete and added mass effects are considered automatically. Additionally, power grid and structural faults like grid fluctuations, eccentricity or failure could be investigated using the same model. In this research work a fast, time resolved dynamic simulation of the complete power train is conducted. As an example, the rotor dynamics of a tidal stream turbine is investigated under two inflow conditions: I - shear flow, II - shear flow + water waves.

Equilibrium and Non-equilibrium Molecular Dynamics Simulations of Thermal Transport Coefficients of Liquid Argon

  • Chang Bae Moon;Gyeong Keun Moon;Song Hi Lee
    • Bulletin of the Korean Chemical Society
    • /
    • 제12권3호
    • /
    • pp.309-315
    • /
    • 1991
  • The thermal transport coefficients-the self-diffusion coefficient, shear viscosity, and thermal conductivity-of liquid argon at 94.4 K and 1 atm are calculated by non-equilibrium molecular dynamics (NEMD) simulations of a Lennard-Jones potential and compared with those obtained from Green-Kubo relations using equilibrium molecular dynamics (EMD) simulations and with experimental data. The time-correlation functions-the velocity, pressure, and heat flux auto-correlation functions-of liquid argon obtained from the EMD simulations show well-behaved smooth curves which are not oscillating and decaying fast around 1.5 ps. The calculated self-diffusion coefficient from our NEMD simulation is found to be approximately 40% higher than the experimental result. The Lagrange extrapolated shear viscosity is in good agreement with the experimental result and the asymptotic formula of the calculated shear viscosities seems to be an exponential form rather than the square-root form predicted by other NEMD studies of shear viscosity. The agreement for thermal conductivity between the simulation results (NEMD and EMD) and the experimental result is within statistical error. In conclusion, through our NEMD and EMD simulations, the overall agreement is quite good, which means that the Green-Kubo relations and the NEMD algorithms of thermal transport coefficients for simple liquids are valid.

비정상 CFD 해석기법을 활용한 5 MW 해상풍력터빈 극한 설계하중조건 해석 (Extreme Design Load Case Analyses of a 5 MW Offshore Wind Turbine Using Unsteady Computational Fluid Dynamics)

  • 김동현;이장호;트란탄도안;곽영섭;송진섭
    • 풍력에너지저널
    • /
    • 제5권1호
    • /
    • pp.22-32
    • /
    • 2014
  • The structural design of a wind turbine must show the verification of the structural integrity of all load-carrying components. Also, design load calculations shall be performed using appropriate and accurate methods. In this study, advanced numerical approach for the calculation of design loads based on unsteady computational fluid dynamics (CFD) is presented considering extreme design load conditions such as the extreme coherent gust (ECG) and the 50 year extreme operating gust (EOG). Unsteady aerodynamic loads are calculated based on Reynolds average Navier-Stokes (RANS) equations with shear-stress transport k-ω(SST k-ω) turbulent model. A full three-dimensional 5 MW offshore wind-turbine model with rotating blades, hub, nacelle, and tower configuration is practically considered and its aerodynamic interference effect among blades, nacelle, and tower is also accurately considered herein. Calculated blade loads based on unsteady CFD method with respect to blade azimuth angle are compared with those by NREL FAST code and physically investigated in detail.

Dynamics of Supercoiled and Linear pBluescript II SK(+) Phagemids Probed with a Long-lifetime Metal-ligand Complex

  • Kang, Jung-Sook;Son, Byeng-Wha;Choi, Hong-Dae;Yoon, Ji-Hye;Son, Woo-Sung
    • BMB Reports
    • /
    • 제38권1호
    • /
    • pp.104-110
    • /
    • 2005
  • We extended the measurable time scale of DNA dynamics to microsecond using $[Ru(phen)_2(dppz)]^{2+}$ (phen = 1,10-phenanthroline, dppz = dipyrido[3,2-a:2',3'-c]phenazine) (RuPD), which displays a mean lifetime near 500 ns. To evaluate the usefulness of this luminophore (RuPD) for probing nucleic acid dynamics, its intensity and anisotropy decays when intercalated into supercoiled and linear pBluescript (pBS) II SK(+) phagemids were examined using frequency-domain fluorometry with a blue light-emitting diode (LED) as the modulated light source. The mean lifetime for the supercoiled phagemids (< $\tau$ > = 489.7 ns) was somewhat shorter than that for the linear phagemids (< $\tau$ > = 506.4 ns), suggesting a more efficient shielding from water by the linear phagemids. The anisotropy decay data also showed somewhat shorter slow rotational correlation times for supercoiled phagemids (997.2 ns) than for the linear phagemids (1175.6 ns). The slow and fast rotational correlation times appear to be consistent with the bending and torsional motions of the phagemids, respectively. These results indicate that RuPD can have applications in studies of both bending and torsional dynamics of nucleic acids.

Defects Nucleation in the Liquid Crystal Director Field from Inhomogeneous Surface

  • Lee, Gi-Dong;Lee, Jong-Wook;Ko, Tae-Woon;Lee, Joun-Ho;Oh, Chang-Ho;Choi, Hyun-Chul;Kim, Jae-Chang
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.1159-1162
    • /
    • 2004
  • A modeling of the nucleation and dynamical behavior of defects from an inhomogeneous surface configuration using fast Q-tensor method is realized. On modeling the defect nucleation and dynamics, A fast Q-tensor method is applied. From the numerical modeling, we confirmed that surface inhomogeneity which makes strong strain energy in the local liquid crystal director field could cause defects. Experimental result has compared with numerical modeling in order to verify the simulation of the defect nucleation.

  • PDF

뉴럴네트워크를 이용한 산업용 로봇의 동특성 해석 (Dynamics Analysis of Industrial Robot Using Neural Network)

  • 이진
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1997년도 춘계학술대회 논문집
    • /
    • pp.62-67
    • /
    • 1997
  • This paper reprdsents a new scheme of neural network control system analysis the robustues of robot manipulator using digital signal processors. Digtal signal processors, DSPs, are micro-processors that are particularly developed for fast numerical computations involving sums and products of variables. Digital version of most advanced control algorithms can be defined as sums and products of measured variables, thus it can be programmed and executed through DSPs. In additions, DSPs are a s fast in computation as most 32-bit micro-processors and yet at a fraction of their prices. These features make DSPs a viable computational tool in digital implementation of sophisticated controllers. Durng past decade it was proposed the well-established theorys for the adaptive control of linear systems, but there exists relatively little general theory for the adaptive control of nonlinear systems. The proposed neuro network control algorithm is one of learning a model based error back-propagation scheme using Lyapunov stability analysis method.

  • PDF

Voltage Quality Improvement with Neural Network-Based Interline Dynamic Voltage Restorer

  • Aali, Seyedreza;Nazarpour, Daryoush
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권6호
    • /
    • pp.769-775
    • /
    • 2011
  • Custom power devices such as dynamic voltage restorer (DVR) and DSTATCOM are used to improve the power quality in distribution systems. These devices require real power to compensate the deep voltage sag during sufficient time. An interline DVR (IDVR) consists of several DVRs in different feeders. In this paper, a neural network is proposed to control the IDVR performance to achieve optimal mitigation of voltage sags, swell, and unbalance, as well as improvement of dynamic performance. Three multilayer perceptron neural networks are used to identify and regulate the dynamics of the voltage on sensitive load. A backpropagation algorithm trains this type of network. The proposed controller provides optimal mitigation of voltage dynamic. Simulation is carried out by MATLAB/Simulink, demonstrating that the proposed controller has fast response with lower total harmonic distortion.

Myrinet 환경에서 예조건화 Navier-Stokes 코드의 병렬처리 성능 (Parallel Performance of Preconditioned Navier-Stokes Code on Myrinet Environment)

  • 김명호;이기수;최정열;김귀순;김성룡;정인석
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2001년도 춘계 학술대회논문집
    • /
    • pp.149-154
    • /
    • 2001
  • Parallel performance of a Myrinet based PC-cluster was tested and compared with a conventional Fast-Ethernet system. A preconditioned Navier-Stokes code was parallelized with domain decomposition technique, and used for the parallel performance test. Speed-up ratio was examined as a major performance parameter depending on the number of processor and the network topology. As was expected, Myrinet system shows a superior parallel performance to the Fast-Ethernet system even with a single network adpater for a dual processor SMP machine. A test for the dependency on problem size also shows that network communication speed is a crucial factor for parallelized computational fluid dynamics analysis and the Myrinet system is a plausible candidate for high performance parallel computing system.

  • PDF

고조파 전류 제거를 위한 새로운 전류 보상 기법 (Novel Current Compensation Technique for Harmonic Current Elimination)

  • 정강률
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.587-591
    • /
    • 2004
  • This paper proposes a novel current compensation technique that can eliminate the harmonic currents included in line currents without computation of harmonic current components. A current controller with fast dynamics for an active filter is described. Harmonic currents are directly controlled without the need for sensing and computing the harmonic current of the load current, thus simplifying the control system. Current compensation is done in the time domain, allowing a fast time response. The DC voltage control loop keeps the voltage across the DC capacitor constant. High power factor control by an active filter is described. All control functions are implemented in software using a single-chip microcontroller, thus simplifying the control circuit. Any current-controlled synchronous rectifier can be used as a shunt active filter through only the simple modification of the software and the addition of current sensors. It is shown through experimental results that the proposed controller gives good performance for the shunt active filter.

  • PDF