• Title/Summary/Keyword: farm houses

Search Result 108, Processing Time 0.023 seconds

TECHNICAL STUDY ON THE CONTROLLING MECHANIQUES OF THE ENVIRONMENTAL FACTORS IN THE MUSHROOM GROWING HOUSE IN CHONNAM PROVINCE (전남지방(全南地方)에 있어서의 양송이 재배(栽培)에 최적(最適)한 환경조건(環境條件) 조절법분석(調節法分析)에 관(關)한 연구(硏究))

  • Lee, Eun Chol
    • Journal of Korean Society of Forest Science
    • /
    • v.9 no.1
    • /
    • pp.1-44
    • /
    • 1969
  • The important results which have been obtained in the investigation can be recapitulated as follows. 1. As demostrated by the experimental results and analyses concerning their effects in the on-ground type mushroom house, the constructions in relation to the side wall and ceiling of the experimental houses showed a sufficient heat insulation on effect to protect insides of the houses from outside climatic conditions. 2. As the effect on the solar type experimental mushroom house which was constructed in a half basement has been shown by the experimental results and analyses, it has been proved to be effective for making use of solar heat. However there were found two problems to be improved for putting solar houses to practical use in the farm mushroom growing: (1) the construction of the roof and ceiling should be the same as for the on-ground type house, and (2) the solar heat generating system should be reconstructed properly. A trial solar heat generating system is shown in Fig. 40. 3. Among several ventilation systems which have been studied in the experiments, the underground earthen pipe and ceiling ventilation, and vertical side wall and ceiling ventilation systems have been proved to be most effective for natural ventilation. 4. The experimental results have shown that ventilation systems such as the vertical side wall and underground ventilation systems are suitable to put to practical use as natural ventilation systems for farm mushroom houses. These ventilation systems can remarkably improve the temperature of fresh air which is introduced into the house by heat transfers within the ventilation passages, so as to approach to the desired temperature of the house without any cooling or heating operation. For example, if it is assuming that x is the outside temperature and y is the amount of temperature adjustment made by the influence of the ventilation system, the relationships that exist between x and y can be expressed by the following regression lines. Underground iron pipe ventilation system ${\cdots}{\cdots}$ y=0.9x-12.8 Underground earthen pipe ventilation system ${\cdots}{\cdots}$y=0.96x-15.11 Vertical side wall ventilation system${\cdots}{\cdots}$ y=0.94x-17.57 5. The experimental results have shown that the relationships existing between the admitted and expelled air and the $Co_2$ concentration can be described with experimental regression lines or an exponent equation as follows: 1) If it is assumed that x is an air speed cm/sec. and y is an expelled air speed in cm/sec. in a natural ventilation system, since the y is a function of the x, the relationships that exist between x and y can be expressed by the regression lines shown below: 2) If it is assumed that x is an admitted volume of air in $m^3/hr$ and y is an expelled volume of air in $m^3/hr$ in a natural ventilation system, since the y is a function of the x, the relationships that exist between x and y can be expressed by the regression lines shown below. 3) If it is assumed that the expelled air speed in cm/sec and replacement air speed in cm/sec. at the bed surface in a natural ventilation system are shown as x and y, respectively, since the y is a function of the x, the relationships that exist between x and y can be expressed by the following regression line: G.E. (100%)- C.V. (50%) ventilation system${\cdots}$ y=0.54X+0.84 4) If it is assumed that the replacement air speed in cm/sec. at the bed surface is shown as x, and $CO_2$ concentration which is expressed by multiplying 1000 times the actual value of $CO_2$ % is shown as y, in a natural ventilation system, since the y is a function of the x the relationships that exist between x and y can be expressed by the following regression line: G.E. (100%)- C.V. (50%) ventilation system${\cdots}{\cdots}$ y=114.53-6.42x 5) If it is assumed that the expelled volume of air is shown as x and the $CO_2$ concentration which is expressed by multiplying 1000 times the actual of $CO_2$ % is shown as y in a natural ventilation system, since the y is a function of of the x, the relationships that exist between x and y can be expressed by the following exponent equation: G.E. (100%)-C.V. (50%) ventilation system${\cdots}{\cdots}$ $$y=127.18{\times}1.0093^{-X}$$ 6. The experimental results have shown that the ratios of the crass sectional area of the G.E. and C.V. vent to the total cubic capacity of the house, required for providing an adequate amount of air in a natural ventilation system, can be estimated as follows: G.E. (admitting vent of the underground ventilation)${\cdots}{\cdots}$ 0.30-0.5% (controllable) C.V. (expelling vent of the ceiling ventilation)${\cdots}{\cdots}$ 0.8-1.0% (controllable) 7. Among several heating devices which were studied in the experiments, the hot-water boilor which was modified to be fitted both as hot-water toiler and as a pressureless steam-water was found most suitable for farm mushroom growing.

  • PDF

A Study on the Mobile Medical Service Program -Based on the Community Diagnosis of a Remote Farm Area- (순회진료사업(巡回診療事業)의 문제점(問題点)과 개선방향(改善方向) (일부(一部) 무의지역에 대(對)한 지역사진단(地域社診斷)을 중심(中心)으로))

  • Park, Hung-Bae;Choi, Dong-Wook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.11 no.1
    • /
    • pp.86-97
    • /
    • 1978
  • The mobile medical service has been operated for many years by a number of medical schools and hospitals as a most convenient means of medical service delivery to the people residing in such area where the geographical and socioeconomic conditions are not good enough to enjoy modern medical care. Despite of official appraisal showing off simply with numbers of outpatients treated and medical persons participated, however, as well recognized, the capability (in respect of budget, equipment and time) of those mobile medical teams is so limitted that it often discourages the recipients as well as medical participants themselves. In the midst of rising need to secure medical service of good quality to all parts of the country, and of developing concept of primary health care system, authors evaluated the effectiveness of and problems associated with mobile medical servies program through the community diagnosis of a village (Opo-myun, Kwangju-gun) to obtain the information which may be halpful for future improvement. 1. Owing to the nationwide Sae-Maul movement powerfully practiced during last several years, living environment of farm villages generally and remarkably improved including houses, water supply and wastes disposal etc. Neverthless, due to limitations in budget time and lack of knowledge (probably the most important), these improvements tend to keep up appearances only and are far from the goal which may being practical benefit in promoting the health of the community. 2. As a result of intensive population policy led by the government since 1962, there has been considerable advances in understanding and the rate of practicing family planning through out the villages and yet, one should see many things, especially education, to be done. Fifty eight per cent of mothers have not received prenatal check and the care for most (72%) delivery was offered by laymen at home. 3. Approximately seven per cent of the population was reported to have chronic illness but since only a few (practically none) of the people has had physical check up by doctors, the actual prevalence of chronic diseases may reach many times of the reported. The same fact was observed also in prevalence of tuberculosis; the patients registered at local health center totaled 31 comprising only 0.51% while the numbers in two neighboring villages (designated as demonstration area of tuberculosis control and mass examination was done recently) were 3.5 and 4.0% respectively. Prevalence rate of all dieseses and injuries expereinced during one month (July, 1977) was 15.8%. Only one tenth of those patients received treatment by physicians and one fifth was not treated at all. The situation was worse as for the chronic patients; 84% of all cases either have never been treated or discontinued therapy, and the main reasons were known to be financial difficulty and ignorance or indifference. 4. Among the patients treated by our mobile clinic, one third was chronic cases and 45% of all patients, by the opinion of doctors attended, were those who may be treated by specially trained nurses or other paramedics (objects of primary care). Besides, 20% of the cases required professional managements of level beyond the mobile team's capability and in this sense one may conclude that the effectiveness (performance) of present mobile medical team is quite limitted. According to above findings, the authors would like to suggest following for mobile medical service and overall medicare program for the people living in remote country side. 1. Establishment of primary health care system secured with effective communication and evacuation (between villages and local medical center) measures. 2. Nationwide enforcement of medical insurance system. 3. Simple outpatient care which now constitutes the main part of the most mobile medical services should largely be yielded up to primary health care unit of the village and the mobile team itself should be assigned on new and more urgent missions such as mass screening health examination of the villagers, health education with modern and effective audiovisual aids, professional training and consultant services for the primary health care organization.

  • PDF

An Economic Analysis of the Effluent Heat Supply from Thermal Power Plant to the Farm Facility House (화력발전소 온배수열 활용 시설하우스 열공급 모형 경제성분석 연구)

  • Um, Byung Hwan;Ahn, Cha Su
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.6-13
    • /
    • 2018
  • Utilizing the heat of cooling water discharge of coal-fired power plant, pipeline investment costs for businesses that supply heat to agricultural facilities near power plants increase in proportion to installation distance. On one hand, the distance from the power plant is a factor that brings difficulties to secure economic efficiency. On the other, if the installation distance is short, there is a problem of securing the heating demands, facility houses, which causes economical efficiency to suffer. In this study, the economic efficiency of 1km length of standard heat pipeline was evaluated. The sensitivity of the heat pipe to the new length variation was analyzed at the level of government subsidy, amount of heating demand and the incremental rate of pipeline with additional government subsidy. As a result of the analysis, it was estimated that NPV 131 million won and IRR 15.73%. The sensitivity analysis showed that NPV was negative when the length of heat pipe facility exceeded 2.6 km. If the government supports 50% of the initial investment, the efficiency is secured within the estimated length of 5.3 km, and if it supports 80%, the length increases within 11.4 km. If the heat demand is reduced to less than 62% at the new length of the standard heat pipe, it is expected economic efficiency is not obtained. If the ratio of government subsidies to initial investment increases, the elasticity of the new bloc will increase, and the fixed investment, which is the cost of capital investment for one unit of heating demand, will decrease. This would result in a reduction in the cost of production per unit, and it would be possible to supply heat at a cheaper price level to the facility farming. Government subsidies will result in the increased economic availability of hot plumbing facilities and additional efficiencies due to increased demand. The greater government subsidies to initial investment, the less farms cost due to the decrease in the price per unit. The results of the study are significant in terms of the economic evaluation of the effectiveness of the government subsidy for the thermal power plant heat utilization project. The implication can be applied to any related pilot to come.

Project of Improving Good Agriculture Practice and Income by Intergrated Agricultural Farming (미얀마 우수농산물 재배기술 전수사업)

  • Lee, Young-Cheul;Choi, Dong-Yong
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.16 no.1
    • /
    • pp.193-206
    • /
    • 2014
  • The objectives of the project are to increase farmers' income through GAP and to reduce the loss of agricultural produce, for which the Korean partner takes a role of transferring needed technologies to the project site. To accomplish the project plan, it is set to implement the project with six components: construction of buildings, installation of agricultural facilities, establishment of demonstration farms, dispatching experts, conducting training program in Korea and provision of equipments. The Project Management Committee and the Project Implementation Team are consisted of Korean experts and senior officials from Department of Agriculture, Myanmar that managed the project systematically to ensure the success of the project. The process of the project are; the ceremony of laying the foundation and commencing the construction of training center in April, 2012. The Ribbon Cutting Ceremony for the completion of GAP Training Center was successfully held under PMC (MOAI, GAPI/ARDC) arrangement in SAl, Naypyitaw on June 17, 2012. The Chairman of GAPI, Dr. Sang Mu Lee, Director General U Kyaw Win of DOA, officials and staff members from Korea and Myanmar, teachers and students from SAl attended the ceremony. The team carried out an inspection and fixing donors' plates on donated project machineries, agro-equipments, vehicles, computers and printer, furniture, tools and so forth. Demonstration farm for paddy rice, fruits and vegetables was laid out in April, 2012. Twenty nine Korean rice varieties and many Korean vegetable varieties were introduced into GAP Project farm to check the suitability of the varieties under Myanmar growing conditions. Paddy was cultivated three times in DAR and twice in SAl. In June 2012, vinyl houses were started to be constructed for raising seedlings and finished in December 2012. Fruit orchard for mango, longan and dragon fruit was established in June, 2012. Vegetables were grown until successful harvest and the harvested produce was used for panel testing and distribution in January 2013. Machineries for postharvest handling systems were imported in November 2012. Setting the washing line for vegetables were finished and the system as run for testing in June 2013. New water tanks, pine lines, pump house and electricity were set up in October 2013.

Evaluation of Genetic Ability for Meat Quality in Hanwoo Cow (육질개량을 위한 한우번식우의 유전능력평가)

  • Won, Jung-Il;Kim, Jong-Bok;Lee, Jeong-Koo
    • Journal of Animal Science and Technology
    • /
    • v.52 no.4
    • /
    • pp.259-264
    • /
    • 2010
  • This study was carried out to estimate genetic parameters and breeding values of Hanwoo cows for carcass traits. Carcass records were collected from Korean steers raised at the private farms located in rural area of Gangwon-do and slaughtered from December 2004 to June 2008 at the three slaughter houses near fattening farm. The results obtained in this study were summarized as follows; The means and standard deviations of the carcass traits were $5.57{\pm}2.01$ for marbling score (MS), $10.87{\pm}4.06mm$ for backfat thickness (BFT), $87.87{\pm}9.07cm^2$ for eye muscle area (EMA), $426.75{\pm}49.27kg$ for carcass weight (CW), and $65.80{\pm}3.80$ for yield index (YI). Heritability estimates using single trait analyses were 0.36 for MS, 0.35 for BFT, 0.24 for EMA, 0.29 for CW, and 0.40 for YI, respectively. Genetic correlation coefficients of MS with BFT, EMA, CW, and YI were -0.21, 0.30, -0.21 and 0.30, and those of BFT with EMA, CW and YI were -0.12, 0.57 and -0.97, and those of EMA with CW and YI were 0.32 and 0.27, respectively. And genetic correlation of CW with YI was -0.62. Single trait selection for MS might lead to reducing BFT, but might be an obstacle to increase CW due to negative genetic correlations of MS with BFT and CW.

Effects of Cultivation Environment and Fruit Ripeness on Microbial Load in Mulberry (재배환경 및 과실 숙도가 오디의 미생물학적 부하량에 미치는 영향)

  • Ryu, Song Hee;Yun, Bohyun;Kim, Hye-Young;Choi, Ah-Hyun;Kim, Se-Ri;Kim, Won-Il;Ryu, Jae-Gee;Han, Sanghyun
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • This study was conducted to investigate the microbial loads in mulberry fruits depending on cultivation environment and fruit ripeness. The population levels of total aerobic bacteria in mulberry fruits collected from open field orchards were higher than those from three plots protected within plastic green houses. In regards to fruit ripeness, the levels of total aerobic bacteria in ripe black fruits were higher than those in unripe green and red mulberry. From the farms into where livestock animals were allowed to enter, Escherichia coli was detected in soil at a level of 4.26~4.94 log CFU/g and in mulberry fruits at 5.03~6.07 log CFU/g, while no coliform and E. coli were detected from where the intrusion of livestock was prevented. We also examined the density change of inoculated E. coli in mulberry fruits as they were becoming mature. While E. coli did not increase in green fruits, two and four log CFU/g increases at $20^{\circ}C$ and $37^{\circ}C$, respectively, were observed with red and fully mature black mulberries during 48 hours incubation. To ensure the food safety of mulberry, it is suggested that the introduction of E. coli into a farm through livestock should be prevented and more hygienic caution should be taken especially when the fruits are ripe.

Effects of Environment Friendly Agricultural Materials to Insect Natural Enemies at Small Green Houses (소형포장에서 친환경농자재가 천적곤충에 미치는 영향)

  • Lee, Dae-Hong;Kang, Eun-Jin;Kang, Myong-Ki;Lee, Hee-Jin;Seok, Hee-Bong;Seo, Mi-Ja;Yu, Yong-Man;Youn, Young-Nam
    • Korean journal of applied entomology
    • /
    • v.47 no.1
    • /
    • pp.75-86
    • /
    • 2008
  • Many kinds of environment friendly agricultural materials (EFAMs) were used for the plant protection, furthermore they support the growth of crops in the greenhouses and the kindly environment friendly farming. Natural enemies might be used for control of insect pest with EFAMs at the same space and time. For testing the toxicity of EFAMs against to natural enemies, 10 EFAMs were selected and tested in small greenhouses and farm's fields. In case of Harmonia axyridis larva, there was no predacious activity against cotton aphids in the block with EFAMMo L, EFAMPE D, EFAMME G and EFAMAE A, otherwise, aphid population was rapidly decreased in the control block without EFAMs. Both of Trialeurodes vaporariorum and Encarsia formosa population were slightly decreased in the block with EFAMs. There were significantly decreased in the block with IEFAM C, FEFAM D, EFAMSM Band EFAMPE D compared with control area. Especially, there was significantly maintained a very low population, both T. vaporariorum and E. formosa in the block with EFAMMo C. The parasitized ratio of Aphidius colemani is also very low in the block with EFAMs compared with control area. In the block with IEFAM C, FEFAM D, EFAMPE D and EFAMMo L, there were significantly different with control area in the number of mummies. Otherwise, in case of Diglyphus isaea and Liriomyza trifolii, there was no significantly different between blocks with and without EFAMs. In the block with EFAMMo C, Tetranychus urticae and Phytoseiulus persimilis populations were significantly maintained a very low level. However, the population of T. urticae was increased, but P. persimilis was decreased in the block with EFAMMo L.

Dehumidification and Temperature Control for Green Houses using Lithium Bromide Solution and Cooling Coil (리튬브로마이드(LiBr) 용액의 흡습성질과 냉각코일을 이용한 온실 습도 및 온도 제어)

  • Lee, Sang Yeol;Lee, Chung Geon;Euh, Seung Hee;Oh, Kwang Cheol;Oh, Jae Heun;Kim, Dea Hyun
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.337-341
    • /
    • 2014
  • Due to the nature of the ambient air temperature in summer in korea, the growth of crops in greenhouse normally requires cooling and dehumidification. Even though various cooling and dehumidification methods have been presented, there are many obstacles to figure out in practical application such as excessive energy use, cost, and performance. To overcome this problem, the lab scale experiments using lithium bromide(LiBr) solution and cooling coil for dehumidification and cooling in greenhouses were performed. In this study, preliminary experiment of dehumidification and cooling for the greenhouse was done using LiBr solution as the dehumidifying materials, and cooling coil separately and then combined system was tested as well. Hot and humid air was dehumidified from 85% to 70% by passing through a pad soaked with LiBr, and cooled from 308K to 299K through the cooling coil. computational Fluid Dynamics(CFD) analysis and analytical solution were done for the change of air temperature by heat transfer. Simulation results showed that the final air temperature was calculated 299.7K and 299.9K respectively with the deviation of 0.7K comparing the experimental value having good agreement. From this result, LiBr solution with cooling coil system could be applicable in the greenhouse.