• Title/Summary/Keyword: fan-beam

Search Result 90, Processing Time 0.028 seconds

Sparse-View CT Image Recovery Using Two-Step Iterative Shrinkage-Thresholding Algorithm

  • Chae, Byung Gyu;Lee, Sooyeul
    • ETRI Journal
    • /
    • v.37 no.6
    • /
    • pp.1251-1258
    • /
    • 2015
  • We investigate an image recovery method for sparse-view computed tomography (CT) using an iterative shrinkage algorithm based on a second-order approach. The two-step iterative shrinkage-thresholding (TwIST) algorithm including a total variation regularization technique is elucidated to be more robust than other first-order methods; it enables a perfect restoration of an original image even if given only a few projection views of a parallel-beam geometry. We find that the incoherency of a projection system matrix in CT geometry sufficiently satisfies the exact reconstruction principle even when the matrix itself has a large condition number. Image reconstruction from fan-beam CT can be well carried out, but the retrieval performance is very low when compared to a parallel-beam geometry. This is considered to be due to the matrix complexity of the projection geometry. We also evaluate the image retrieval performance of the TwIST algorithm -sing measured projection data.

An Investigation of fan type anchorages applied to end of CFRP strips

  • Kara, M. Emin;Yasa, Mustafa
    • Steel and Composite Structures
    • /
    • v.15 no.6
    • /
    • pp.605-621
    • /
    • 2013
  • CFRP strips are widely used nowadays for repair/strengthening or capacity increase purposes. Sharp bending at the ends of the CFRP strips is frequently encountered at these applications. In this study, Reinforced Concrete (RC) beam specimens that were produced with 10 MPa compression strength concrete were strengthened by using bonded CFRP strips with end anchorages to tension region. The parameters that were investigated in this study are the width of the strip, the number of applied fan anchorages and whether additional layer of CFRP patch is used or not at the strip ends. Specimens were strengthened with 100 mm wide CFRP strips with one or two anchorages at the ends. In addition CFRP patch with two and three anchorages at the ends were tested for investigating the effect of the patches. Specimens that were strengthened with three anchorages at the ends with patches were repeated with 60 and 80 mm wide CFRP strips. The most successful result was obtained from the specimen that was strengthened with 80 mm wide CFRP strips with 3 end anchorages and patches among the others at the experimental program. The numbers of anchorages that were applied to ends of CFRP strips were more effective than the width of the CFRP strips onto strength and stiffness of the specimens. Due to limited space at the ends of the strips at most three anchorages could be applied.

Comparing the Installing Angle Rafter of China.Japan and Korea (중국.일본과 우리나라의 추녀설치방식의 비교 연구)

  • Hong, Byung-Hwa
    • Journal of architectural history
    • /
    • v.21 no.2
    • /
    • pp.21-36
    • /
    • 2012
  • As wooden construction developed, it was observed that the rafters with corners changed to angled rafters. The change from rafters to angle rafters means that the angle rafters became the most important member in supporting the roof weight as the construction scale increased and structurally developed. The specific installation methods of angle rafters were all unique in Korea, China, and Japan. In East Asia, the angle of the angle rafter gradually decreased along with the development of construction. However, in Joseon Dynasty Korea, the angle of the angle rafter was larger than that of the Gorye era because the method of fixing the corner of the roof more firmly by building the fan-shaped rafter was utilized. The changes to the angle rafter installation method is a unique characteristic of Korea, in that it was developed in a totally different way from the methods used in China and Japan.

Dynamical Analysis and Design of Bearingless Rotor Flexbeam

  • Shi, Weixing;Wang, Jidong
    • International Journal of Aerospace System Engineering
    • /
    • v.2 no.1
    • /
    • pp.24-30
    • /
    • 2015
  • In helicopter bearingless rotor design, the flexbeam is the key component of rotor system, which plays an importantrole in the blade flapping, lead-lag movement, torsion, and load transfer. Flexbeam must have the minimum torsion stiffness with enough tension strength. In this paper, we first investigated the torsion stiffness of different cross section configurations of the flexbeam through some simple experiments. Then we analyzed a rotor's dynamical characteristics with finite element method and got the rotor's fan plot. After that, we studied the relationship between the frequency changes with the spanwise distribution of mass and stiffness in bearingless rotor. Finally, we analyzed the influence of the flexbeam on dynamical characteristics of the bearingless rotor system, and completed the design of this type of rotor flexbeam.

Shear strengthening of reinforced concrete beams with rectangular web openings by FRP Composites

  • Abdel-Kareem, Ahmed H.
    • Advances in concrete construction
    • /
    • v.2 no.4
    • /
    • pp.281-300
    • /
    • 2014
  • This study presents the experimental results of twenty three reinforced concrete beams with rectangular web openings externally strengthened with Fiber Reinforced Polymers (FRP) composites bonded around openings. All tested beams had the same geometry and reinforcement details. At openings locations, the stirrups intercepted the openings were cut during fabrication of reinforcement cage to simulate the condition of inclusion of an opening in an existing beam. Several design parameters are considered including the opening dimensions and location in the shear zone, the wrapping configurations, and the amount and the type of the FRP composites in the vicinity of the openings. The wrapping configurations of FRP included: sheets, strips, U-shape strips, and U-shape strips with bundles of FRP strands placed at the top and sides of the beam forming a fan under the strips to achieve closed wrapping. The effect of these parameters on the failure modes, the ultimate load, and the beam stiffness were investigated. The shear contribution of FRP on the shear capacity of tested beams with web openings was estimated according to ACI Committee 440-08, Canadian Standards S6-06, and Khalifa et al. model and examined against the test results. A modification factor to account for the dimensions of opening chords was applied to the predicted gain in the shear capacity according to ACI 440-08 and CSA S6-06 for bonded Glass Fiber Reinforced Polymers (GFRP) around openings. The analytical results after incorporating the modification factor into the codes guidelines showed good agreement with the test results.

Retrofitting of shear damaged RC beams using CFRP strips

  • Altin, Sinan;Anil, Ozgur;Toptas, Tolga;Kara, M. Emin
    • Steel and Composite Structures
    • /
    • v.11 no.3
    • /
    • pp.207-223
    • /
    • 2011
  • The results of an experimental investigation are presented in this paper for retrofitting of shear damaged reinforced concrete beams by using U shaped CFRP strips. The experimental program is consisted of seven shear deficient T cross sectioned 1/2 scale simply supported beam specimens. One beam was used as reference specimen, and the remaining six specimens were tested in two stages. At the first stage, specimens were shear damaged severely, and then were retrofitted by using CFRP strips with or without fan type anchorages. Finally, retrofitted beams were tested up to failure. Three different CFRP strip spacing were used such as 125 mm, 150 mm, and 200 mm. The effect of anchorages on shear strength and behavior of the retrofitted specimens is investigated. CFRP strips without anchorages improved the shear strength, but no flexural failure mode was observed. Specimens showed brittle shear failure due to peeling of CFRP strip from RC beam surface. Shear damaged specimens retrofitted with anchoraged CFRP strips showed improved shear strength and ductile flexural failure. Maximum strains at anchoraged strips were approximately 68% larger than that of strips without anchorages.

Mechanical behavior of prefabricated steel-concrete composite beams considering the clustering degree of studs

  • Gao, Yanmei;Fan, Liang;Yang, Weipeng;Shi, Lu;Zhou, Dan;Wang, Ming
    • Steel and Composite Structures
    • /
    • v.45 no.3
    • /
    • pp.425-436
    • /
    • 2022
  • The mechanical behaviors of the prefabricated steel-concrete composite beams are usually affected by the strength and the number of shear studs. Furthermore, the discrete degree of the arrangement for shear stud clusters, being defined as the clustering degree of shear stud λ in this paper, is an important factor for the mechanical properties of composite beams, even if the shear connection degree is unchanged. This paper uses an experimental and calculation method to investigate the influence of λ on the mechanical behavior of the composite beam. Five specimens (with different λ but having the same shear connection degree) of prefabricated composite beams are designed to study the ultimate supporting capacity, deformation, slip and shearing stiffness of composite beams. Experimental results are compared with the conventional slip calculation method (based on the influence of λ) of prefabricated composite beams. The results showed that the stiffness in the elastoplastic stage is reduced when λ is greater than 0.333, while the supporting capacity of beams has little affected by the change in λ. The slip distribution along the beam length tends to be zig-zagged due to the clustering of studs, and the slip difference increases with the increase of λ.

Digital Tomosynthesis for Patient Alignment System Using Half-fan Mode CBCT Projection Images (Half-fan 모드를 이용한 방사선치료환자 위치교정을 위한 디지털영상 합성영상기술에 관한 예비연구)

  • Park, Justin C.;Park, Sung-Ho;Kim, Jin-Sung;Han, Young-Yih;Ju, Sang-Gyu;Shin, Eun-Hyuk;Shin, Jung-Suk;Park, Hee-Chul;Ahn, Yong-Chan;Song, Willian Y.
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.360-366
    • /
    • 2010
  • To generate on-board digital tomosynthesis (DTS) for three-dimensionalimage-guided radiation therapy (IGRT) as an alternative to conventional portal imaging or on-board cone-beam computed tomography (CBCT), two clinical cases (liver and bladder) were selected to illustrate the capabilities of on-board DTS for IGRT. DTS images were generated from subsets of CBCT projection data (45, 162 projections) using half-fan mode scanning with a Feldkamp-type reconstruction algorithm. Digital tomosynthesis slices appeared similar to coincident CBCT planes and yielded substantially more anatomic information. Improved bony and soft-tissue visibility in DTS images is likely to improve target localization compared with radiographic verification techniques and might allow for daily localization of a soft-tissue target. Digital tomosynthesis might allow targeting of the treatment volume on the basis of daily localization.

The resolution recovery - Application to various CT systems

  • Kim, Hong-Suk;Lee, Soo-Young
    • Proceedings of the KIEE Conference
    • /
    • 1979.08a
    • /
    • pp.160-161
    • /
    • 1979
  • The degradation of image due to the finite size of sensing device has been one of the problems to all of the digital imaging systems. The improvement of the spatial resolution has been attempted by "differential method" with fixed sensor size and finer sampling. The computer simulations were carried out for the cases of PLF system (Parallel Linear Fan-beam) and SR(Stationary Ring) system and the results are presented.

  • PDF

Strut-and-Tie Model for Thick Footing (두꺼운 기초의 스트럿-타이 모델)

  • Chun, Sung-Chul;Hong, Sung-Gul;Oh, Bo-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.111-112
    • /
    • 2009
  • A thick footing is a D-region and it cannot be designed according to Bernoulli's beam theory. Using a smeared nodal zone and a fan, the thick footing is modeled based on an actual stress flow. A design procedure for determining a depth of the footing and an amount and a development length of reinforcement is provided.

  • PDF