• Title/Summary/Keyword: fan room

Search Result 165, Processing Time 0.02 seconds

Development of an Automatic Face Velocity Controller for a Fume Hood System (흄후드 시스템의 면 풍속 자동 제어기 개발)

  • Kim, Hogeol;Jeong, Kyuwon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.2
    • /
    • pp.304-309
    • /
    • 2013
  • In chemical, medical or biology laboratories Fume Hoods are basic facilities which can protect researchers from dangerous gas as blowing the contaminated air outside. After the air inside the laboratory room is sucked into the hume hood, then, it is blew out by a fan rotated by an AC induction motor. In addition, a damper controls the inside opening of a duct, which the air flows through. The face velocity, air velocity through the front door, have to be kept constant as the set value even though the opening of the door is varied. However, conventional fume hood used to be operated by operator's manual switches. So that, in this paper an automatic control system is developed which controls the face velocity by adjusting the rotating speed of the blow motor and the opening of the damper. Experiments show that this developed system can be used at such laboratories.

Charactericstics of Heat Flow in a Machine Room of Refrigerator(II) (냉장고 기계실 내부 열 유동 특성 해석(II))

  • 한병윤;김재열;김태훈;김영국;이연원
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.173-179
    • /
    • 2002
  • There is a growing concert about energy efficiency at the present time. Even refrigerators can not be omitted from this issue. So the factors have been searched to decrease the consumption of electric power in refrigerators. It is possible to analyze the numerical data of the cover back machine and the change of condenser shape to find that they affect the consumption of electric powers by improving the fluid flow of within the interior of the refrigerator. As a result, the problems, fluid of the eddy and stationary of the existing refrigerator can be solved partly by the improved model.

  • PDF

Structural studies of $Mn^+$ implanted GaN film

  • Shi, Y.;Lin, L.;Jiang, C.Z.;Fan, X.J.
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.S1
    • /
    • pp.56-59
    • /
    • 2003
  • Wurtzite GaN films are grown by low-pressure MOCVD on (0001)-plane sapphire substrates. The GaN films have a total thickness of 4 $\mu$m with a surface Mg-doped p-type layer, which has a thickness of 0.5 $\mu$m. 90k eV $Mn^{+}$ ions are implanted into the GaN films at room temperature with doses ranging from $1 \times10^{15}$ to $1 \times 10^{16}\textrm{cm}^{-2}$. After an annealing step at $770^{\circ}C$ in flowing $N_2$, the structural characteristics of the $Mn^{+}$ implanted GaN films are studied by X-ray diffraction (XRD), Rutherford backscattering spectrometry (RBS) and atomic force microscopy (AFM). The structural and morphological changes brought about by $Mn^{+}$ implantation and annealing are characterized.

Integrated management technology of environmental control facilities underground living space (지하 생활공간 환경제어 설비 통합관리 기술)

  • Gang, Hyeon-Geun;Kim, Tae-Han;Jeon, Jin-Han;Lee, Seung-Hong
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.95-98
    • /
    • 2008
  • A power line communications, power, the outgoing line is a means of communication. DC 12 volt power lines in the system over the 2-wire control signals with the power to send the cargo configuration, and, in the basement living space, temperature, humidity, dust, CO2 sensors, and through the cooperation of the real-time detection and valves of the appropriate amount of wind, fan was designed to control. By the system's ability to communicate and control the room temperature or the status of amount of wind sent to the central system to transmit and receive signals to the center of the future, the ability to control the company said. In addition, the system HMI (Human Machine Interface) terminal by the direct control and if necessary personal portable devices to communicate with the living conditions of the underground environment in the best state that the purpose is to build.

  • PDF

A Numerical Study on Flow Field near the Roller Conveyor for Flat Panel Display (평면 디스플레이 기판 운송용 롤러 컨베이어 주위의 유동장에 관한 수치해석 연구)

  • Jeon, Hyun-Joo;Kim, Hyoung-Jin;Im, Ik-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.6-11
    • /
    • 2009
  • Flow field in a roller conveyor system, induced from the movement of a cassette in which glasses for flat panel display are loaded, is numerically studied in this paper. Contamination on the glass surface by dust particles produced from mechanical friction between roller and cassette is predicted from the analysis results of flow fields. Results show that a large swirl flow is formed under the moving cassette with constant speed. This swirl flow is confined only under the cassette because two main streams from the backward and the fan filter unit on the top ceiling are sufficiently strong. Therefore, it can be said that possibility of the contamination by the particles originated from the friction is relatively low. It is also revealed that flow direction between glass plates is changed according to the speed of the cassette movement due to the shear force of glass plates.

Analysis of New Air Control System in Clean Stocker (Clean Stocker내 새로운 방식의 기류제어에 관한 해석)

  • Choe, Gi-Han;Han, Chang-U;Lee, Sang-Ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.1
    • /
    • pp.121-130
    • /
    • 2002
  • Clean stockers are being used by semiconductor and TFT-LCD manufacturers to store and buffer work in process. Since an important function of a stocker is to keep the contained material clean. The only way to keep the stored product clean is to provide constant clean airflow the product and through stocker, The airflow across the product prevent contamination from settling on the product. Up to now, stocker typically have been configured to receive their laminar airflow from fan filter units that are located on the side of the stocker This type of stocker may have such problems as complexity of structure, increment of temperature, mechanical vibration, initial investment and running cost. In this study, In order to solve the above mentioned problems, new air control system in stocker is proposed, which is to control open ratios of exits that are located on the side of the stocker without fan filter units. Open ratios of exits need to be optimized for the same quantities of airflow in each exit. In this study, static pressure regain was used for the analysis of the open ratios of exits theoretically and Blue Ridge Numerics FEM software, CFDesign, was used fur simulating airflow in stocker. As a result, Open ratios of exits important to provide constant clean airflow can be obtained by the analysis of static pressure regain and was verified by simulation results. Therefore, new air control system in stocker can be used by the semiconductor and TFT-LCD manufacturers.

Automatic Control System in Room using Zigbee Sensor and Microcontroller Chip (무선센서와 마이크로 컨트롤러를 이용한 실내 환경 자동 제어 시스템)

  • Jean, Byoung-Chan;Choi, Gyoo-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.5
    • /
    • pp.147-154
    • /
    • 2009
  • Lately, superhigh speed network infra is developing with the fast speed, is evolved by step that existent appliances are digitalised and appliances are become remote control by being gear to network. Also, gearing in Home network and superhigh speed network infra, control appliances in Internet and research that do monitering is proceed. Therefore, describe about indoor environment automatic control system that use Wireless sensor and Microcontroler in this paper. Because using that electric power, Zigbee sensor and Wireless module, embodied system that measured in the room temperature and use ATmega128 Microcontroler and use each device (temperature, illumination, humidity) back in house and control humidifier, electric fan etc. Can use variously in Home network field by this Wireless sensor and Microcontroler base, and also can apply variously to several industry fields as well as Home network field.

  • PDF

Economic Analysis for Warehouse Rental Using Underground Parking Lots Extra Storage Room of Rental Office (임대오피스 지하주차장 여유공간을 활용한 임대창고의 경제성 분석)

  • Lee, Hwan-Cheol;Song, Byung-Doo;Hong, Tae-Hoon;Hyun, Chang-Taek;Moon, Hyun-Seok
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.877-882
    • /
    • 2008
  • The column gap of underground parking lots of office considering a business background and effective parking divisions is planned. A parking plan by column gap of fixed forms in atypical underground parking lots makes much extra storage rooms. Most of the edge of the parking lots are used for fan room. Part of the edge are located at parking ramps. Also warehouses are located in extra storage rooms. In this study compare study economical efficiency between life cycle costs and leases earnings. Consequently, It is proved that the warehouse rental is efficient because of lease earning guaranted years.

  • PDF

The Measurement of Airtightness Performance of Multi-Family Housing (다가구 및 다세대 원룸주택의 기밀성능 실측연구)

  • Baek, Nam-Choon;Han, Seung-Hyeon;Lee, Wang-Je;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.14 no.5
    • /
    • pp.117-121
    • /
    • 2014
  • Even though a study of airtightness performance of apartment and detached house have been done constantly, there are few of studies of multi-family housing which increasing every year. Therefore, this study analyzed airtightness performance of 20 households of one room in Daejeon to investigate airtightness performance standard. All experiments were performed under the same conditions except sealing windows to investigate airtightness performance without sealing windows (natural condition) and airtightness performance with sealing windows of studio apartment. As results, (1) average ACH50 without sealing windows was 19.2/h for pressurization, and 12.8/h for depressurization and (2) average ACH50 with sealing windows was 16.0/h for pressurization, and 10.7/h for depressurization and ACH50 in both condition, ACH50 under pressurization was about 50% higher than that under depressurization. Throughout this experiment, we can figure out that about 16% of air infiltration rate is occurred in windows, and the other 84% is occurred in rest of places such as Junction structure, socket and ventilating opening.

A Study on the Indoor-Outdoor $NO_2$ Levels and Personal Exposures to $NO_2$ with Analysis of factors Affecting the $NO_2$ Concentrations - Centering on Urban Homes and Housewives - (실내외 $NO_2$농도 및 $NO_2$개인폭로량과 이들에 영향을 미치는 요인에 관한 연구 -도시지역 주택 및 주부를 대상으로-)

  • Chun, Jin-Ho;Lee, Chae-Un;Kim, Joon-Youn;Chung, Yo-Han
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.1 s.23
    • /
    • pp.132-151
    • /
    • 1988
  • This study was conducted to establish the control program for preventing unfavorable health effects of nitrogen dioxide($NO_2$) exposure in homes by preparing the fundamental data for evaluation of relation-ships between $NO_2$ levels and influencing factors through measurements of indoor-outdoor $NO_2$ levels and personal $NO_2$ exposures for housewives with questionnaire survey on 172 homes in Pusan area from April to June, 1987 $NO_2$ measurements were made by using diffusion tube samplers(Palmes tube $NO_2$ sampler) for one week at 4 sites in homes ; kitchen(KIT), bedroom(BED), living room(LIV), outdoor(OUT) and near the collar of housewives(personal exposure livel, PNO). The details of questionnaire were number of household members(FAM), number of regular smokers (SMOKER), daily number of meals eaten(MEAL), type of housing units(HOUSE), location of house with distance from the heavy traffic roads as walking time(DIST), and of kitchen(KAREA), kind of cooking fuels(FUEL), cooking time of each meal(CTIME), usage of kitchen fan for cooking(FAN), type of heating facilities(HEAT) and so on of subject homes. The Obtained results were as fellows : 1) The mean $NO_2$ level was significantly higher at indoors than outdoors(p<0.01) and the kitchen $NO_2$ level was the highest with $33.7{\pm}13.6ppb$(9.5-81.5ppb). The mean personal exposure level of $NO_2$ for housewives was $20.6{\pm}8.8ppb$(3.1-46.9ppb). 2) The mean indoor $NO_2$ level was significantly higher in the group of household members above 5 than below 4(p<0.05), in detached dwellings than apartments(p<0.001), within 5 minutes of distance than over 5 minutes(p<0.001), in the group of unusing fan(p<0.001), in the group of longer cooking time(p<0.001), and it was in order of coal briquette, gas, electricity and oil by kind of cooking fuels(p<0.05). 3) Variables showing significant correlation(p<0.001) with indoor $NO_2$ level were kitchen $NO_2$ level(r=0.8677), cooking time(r=0.5921), outdoor $NO_2$ level(r=0.5192), personal $NO_2$ exposure level(r=0.4615), usage of kitchen fan(r=0.3573) and location of house(r=-0.2988) 4) As a result of multiple regression analysis, the most significant influencing variable to the kitchen $NO_2$ level was cooking time[KIT=$-0.378{\pm}11.772$(CTIME)+0.298(OUT)+3.102(FAN)], it was kitchen $NO_2$ level to the indoor $NO_2$ level[IND=6.996+0.458(KIT)+0.230(OUT)-1.127(KAREA)], and it was indoor $NO_2$ level to the personal $NO_2$ exposure level[PNO=15.562+0.729(IND)-4.542(DIST)-0.200(KIT)] 5) It was recognized that aritificial ventilation in the kitchen, suppression of unnecessary combustion and replacement of cooking fuel, as much as possible, were effective means for decreasing indoor $NO_2$ levels in homes.

  • PDF