• Title/Summary/Keyword: fan effect

검색결과 572건 처리시간 0.023초

직교류 홴의 유동 해석: 깃 형상 변화가 성능에 미치는 영향 (A Numerical Study on Flow through a Cross Flow Fan: Effect of Blade Shapes on Fan Performance)

  • 허남건;김욱;강신형
    • 한국유체기계학회 논문집
    • /
    • 제2권1호
    • /
    • pp.96-102
    • /
    • 1999
  • Cross flow fans are used in various applications, especially in industrial ventilation applications and in room air conditioners, due to their superior performance characteristics. Unlike radial and/or axial fans, the design of cross flow fans have been mostly based on earlier experiences and experiments. In the present study, numerical computations of flow fields through a cross flow fan used in room air conditioner are performed to investigate the detailed flow fields and to study the effect of the blade shape on performance curves to aid better design of the fan. Despite some discrepancies between the two results, it is seen from the present study that the computational results agree quite well with the qualitative experimental results. It is also shown from the present study that by having a different shape of blade, it is possible to achieve about $15\%$ increase in flow rates. The stimulating results of the present study can be used in the design of high performance cross flow fans with the use of optimal design algorithm and experimental verifications.

  • PDF

고온기 유리온실의 냉방방법이 토마토 생육 및 수량에 미치는 영향 (Effect of Greenhouse Cooling Method on the Growth and Yield of the Tomato cv. Momotaro in Warm Season)

  • 이재한;박동금;권준국;엄영철;최영하
    • 생물환경조절학회지
    • /
    • 제9권1호
    • /
    • pp.60-64
    • /
    • 2000
  • 여름철 시설내 온도강하를 위해 차광, 포그, 미스트, Fan and Pad 등 다양한 방법들이 행해지고 있고 그 효과에 대해서도 잘 알려져 있다. 그러나 대부분의 효과가 처리방법간 일 최고 기온시의 상대적인 비교를 나타낸 것이므로 실제로 일평균, 순평균하게 되면 그효과는 미미하게 된다. 더구나 우리나라는 8월중 맑은날이 10일 미만이고 상대습도가 놀기 때문에 기화냉각 효과는 더욱 떨어지게 된다. 따라서 여름철 토마토 재배시 온도강하 방법으로 포그처리는 냉방효파에 비해 설치 및 유지관리비에 많은비용이 소요되는 문제가 있고, 온도제어 차광은 지나치게 차광되어 수량감소가 많아 부적합하므로 팬+일사제어 자동차광으로 외기온 가까이 온도를 내리는 것을 목표로 하는 것이 경제적일 것으로 생각된다.

  • PDF

소형 원심형 팬의 형상변수가 성능에 미치는 영향에 대한 실험적 연구 (Experimental Study for the Effect of Dimensional Parameters on the Performance of Small Centrifugal Fans)

  • 최종수;이욱
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.57-63
    • /
    • 1998
  • The performance of a centrifugal fan depends on the dimensional parameters of impeller, such as the inlet and exit diameter, area ratio, relative flow angles to the blade, and number of blades. These design parameters, however, are inter-related, so it is very difficult to identify the effect of each parameter to the fan performance. In this experimental study the effect of the design parameters on the performance of a small centrifugal impeller being used for vacuum cleaners are investigated. Total 30 shrouded impellers with 120mm diameter were tested and the results were non-dimensionalized to compare their performance.

  • PDF

냉각팬 전자제어를 통한 시내버스의 연비 개선 (The Effect of Cooling Fan Control on Fuel Economy of City Bus)

  • 김기복;박진일;이종화;박경석
    • 한국자동차공학회논문집
    • /
    • 제21권6호
    • /
    • pp.1-7
    • /
    • 2013
  • This paper focuses on cooling fan control by using a magnetic clutch type for the improvement of fuel economy on a heavy city bus. In general, Heavy duty vehicles use viscous clutch type cooling fan which has some disadvantages, such as slow response, wide temperature variation of engine coolant water. But a magnetic clutch type cooling fan can be controlled electronically so the engine coolant temperature can be precisely controllable and this effects could be used to reduce fuel consumption. A control system for applying the magnetic clutch type cooling fan was developed in this study and applied to the real field test and chassis dynamometer test. The result showed well controlled coolant temperature and enhancement of fuel economy.

개방된 챔버 입구에서 작동하는 소형 프로펠러 팬 주위의 난류유동해석 (Numerical analysis of turbulent flow around a small propeller fan operating at the inlet of open chamber)

  • 오건제;강신형
    • 대한기계학회논문집B
    • /
    • 제21권12호
    • /
    • pp.1586-1594
    • /
    • 1997
  • Performance characteristics of a small propeller fan are numerically investigated solving the continuity and Reynolds-averaged Navier-Stokes equations. The Reynolds stresses for turbulent transport are modelled using a k-.epsilon. turbulence model. The present numerical procedure is constructed using the Finite Volume Method with the SIMPLE algorithms. The performance parameters obtained from the calculations are compared with the measured values for the various flow rates. A performance test of the fan shows different characteristics between a radial type at small flow rates and an axial type at large flow rates. Comparisons between the predictions and the measurements show that the predicted results are in good agreement with the measured values and reasonably reproduce the sharp variations of the power and head coefficient around a flow coefficient .PHI.=0.3. These comparisons indicate that the present numerical method is capable of resolving the performance characteristics with reasonable accuracy. At low flow rates, it is found that the flow enters the fan in an axial direction and is discharged radially outward at the tip which happens in the centrifugal fan. The centrifugal effect makes a significant difference in the characteristics of a fan at the low and high values of flow coefficient.

스윕을 가진 냉각탑용 축류홴의 성능 특성에 관한 수치해석적 연구 (Numerical Investigation of Performance Characteristics for Cooling Tower Axial Fans with Sweep)

  • 오건제
    • 동력기계공학회지
    • /
    • 제13권4호
    • /
    • pp.31-37
    • /
    • 2009
  • The purpose of this numerical study was to investigate performance characteristics for cooling tower axial fans with sweep. Performance data for the fans with various sweep angles were obtained in terms of the setting angle at a constant flow rate. Viscous flow calculations were carried out to obtain Performance data of the total pressure rise and hydraulic efficiency. A solution of the Ffowcs Williams-Hawkings equations was used to calculate the sound pressure level at three times fan diameter away from the fan. The calculated performance data well represented performance characteristics of the cooling tower axial fan. The total pressure rise and hydraulic efficiency at the same setting angle decreased with sweep angle. Sound pressure level slightly decreased for the fan with a sweep angle of 10 degree. No significant effect of the sweep geometry was found on the sound pressure level.

  • PDF

유동안정화 장치가 홴 테스터의 성능에 미치는 영향 (Effects of Flow Settling Means on the Performance of Fan Tester)

  • 최영석;김덕수;윤준용
    • 한국유체기계학회 논문집
    • /
    • 제8권5호
    • /
    • pp.29-34
    • /
    • 2005
  • In this study, the effect of flow settling means on the performance of fan tester were numerically investigated by using a computational fluid dynamics (CFD). The airflow rate was calculated from the pressure differential across a flow nozzle in the measuring plane and the flow settling means were generally installed in the chamber of the fan tester to provide proper airflow patterns ahead of the measuring plane. The predicted nozzle differential pressures with uniform inlet velocities were compared with the values of the ANSI/AMCA 210-99 to verify the performance of the commercial CFD code CFX 5.6. The influence of flow settling means on the measurement of airflow rate in a fan tester were discussed with various porosities and inlet jet velocities. The results obtained show that the proper band of porosities exist to meet the AMCA standard in a specified inlet jet velocity.

원심 다익홴의 유동에 대한 컷 오프 각도의 영향 (Effect of Cut-off Angle on Flow Pattern of Centrifugal Multi-blade Fan)

  • 강경준;신유환;이윤표;김광호
    • 한국유체기계학회 논문집
    • /
    • 제13권3호
    • /
    • pp.37-42
    • /
    • 2010
  • This study investigated on details of flow characteristics of a multi-blade fan for domestic ventilation. Experiments and analysis were carried out to describe on flow pattern with variations of cut-off angle near the scroll housing throat, which were performed by PIV measurement for the flow field and by total pressure probes. The stagnation point at cut-off region of the fan moves to the exit of the scroll housing as the cut-off angle increases. The movement of stagnation point and the variation of throat area of the scroll housing influence to the distribution of velocity magnitude at the exit of the fan. Furthermore, a large distortion of the velocity distribution at the scroll exit causes to increase mixing loss along the flow path.

유동안정화 장치가 홴 테스터의 성능에 미치는 영향 (Effects of Flow Settling Means on the Performance of Fan Tester)

  • 최영석;김덕수;윤준용
    • 한국유체기계학회 논문집
    • /
    • 제9권4호
    • /
    • pp.43-48
    • /
    • 2006
  • In this study, the effect of flow settling means on the performance of fan tester were numerically investigated by using a computational fluid dynamics(CFD). The airflow rate was calculated from the pressure differential across a flow nozzle in the measuring plane and the flow settling means were generally installed in the chamber of the fan tester to provide proper airflow patterns ahead of the measuring plane. The predicted nozzle differential pressures with uniform inlet velocities were compared with the values of the ANSI/AMCA 210-99 to verify the performance of the commercial CFD code CFX 5.6. The influence of flow settling means on the measurement of airflow rate in a fan tester were discussed with various porosities and inlet jet velocities. The results obtained show that the proper band of porosities exist to meet the AMCA standard in a specified inlet jet velocity.

실외기 shroud 설계 인자에 따른 유량 특성 (Characteristics of flow rate according to design parameters of a shroud in outdoor unit)

  • 유기정;김민수;차우호;이관수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.244-249
    • /
    • 2008
  • In this study, the characteristics of flow in outdoor unit were numerically analyzed. Parametric studies were performed to compare the effect of bell mouth height, fan height and fan width concerned with flow rate. The result indicated that the flow rate was dependent on the bell mouth height, while it was negligibly affected by the fan height and fan width. The fan width was found to affect the velocity distribution at heat exchanger face.

  • PDF