• 제목/요약/키워드: fan

검색결과 3,609건 처리시간 0.029초

에너지 전환 이상기능 기반 다구찌 동특성을 활용한 Fan Case 설계 (Fan Case Design using Energy Conversion Ideal Function Based Taguchi Dynamic Characteristics)

  • 지수윤;장중순
    • 대한산업공학회지
    • /
    • 제41권1호
    • /
    • pp.97-104
    • /
    • 2015
  • An electric-motor which uses electric energy to dry laundry in a dryer generates wind by rotating a fan. The roles of electric motor and fan are crucial for drying. To reduce the noises or vibration, their performances should be improved. However, it requires a relatively high cost to redesign them. In this case, redesigning the fan case rather than the motor or the fan would be easier and cheaper. This paper is to apply Taguchi dynamic characteristic concept with the ideal function of energy conversion to redesign the fan case. Not only the increase of the wind power but also the decrease of noise, vibration and the other side effects are resulted.

5톤 송풍기용 FAN 인양기 구조설계 (Structural Design of CN fan Lift of 5 tonne Fans for Air Conditioner)

  • 이형욱;이광희
    • 융복합기술연구소 논문집
    • /
    • 제9권1호
    • /
    • pp.25-30
    • /
    • 2019
  • Normal cranes cannot be used to move the fan inside the high-rise factories. Due to the size of the fan and safety accidents, there is a need for a structure capable of lifting and transporting. In this study, the safety of the structure was evaluated by considering the center of gravity of the fan and the effect of the fan being tilted up. An analysis of the buckling was performed by hand calculation. Nonlinear analysis was performed using ABAQUS to evaluate the safety of the structure. The safety factor for buckling is above 4.0 and the safety factor for stress is calculated to be 1.31 under the worst load distribution conditions.

허브 캡 형상에 따른 축류송풍기 성능특성 (Performance Characteristics of an Axial Flow Fan According to the Shape of a Hub Cap)

  • 장춘만;최승만;김광용
    • 한국유체기계학회 논문집
    • /
    • 제9권6호
    • /
    • pp.9-16
    • /
    • 2006
  • Performance characteristics of an axial flow fan having distorted inlet flow have been investigated using numerical analysis as well as experiment. Two kinds of hub-cap, rounded and right-angled front shape, are tested to investigate the effect of inlet flow distortion on the fan performance. Numerical solutions are validated in comparison with experimental data measured by a five-hole probe downstream of the fan rotor. It is found from the numerical results that non-uniform axial inlet velocity profile near the hub results in the change of inlet flow angle. Large recirculation flow upstream the fan rotor for the right-angled hub-cap induces a negative incidence, thus invokes separated flow on the blade surfaces and deteriorates the performance of fan rotor.

KTX용 터보팬 블레이드 개발 (The Development of Turbo-Fan Blade for KTX)

  • 장영민;권오운;김성준
    • 산업기술연구
    • /
    • 제29권B호
    • /
    • pp.41-45
    • /
    • 2009
  • The new cooling fan for various parts & equipments of KTX is developed and evaluated to improve fan performance and durability. The characteristic curve of the developed fan is obtained according to KSB 6311 of performance test regulation. 70 degree of the installation angle of blade makes the fan to produce a maximum flow rate. This angle is found out through trial-error and is confirmed through the verification test. In order to improve the blade strength, the blade is produced by a draw forming. The adoption of AL50 reduces a fan weight by 6 kg. The new blade makes a static pressure 170 (mmAq), a discharge rate $140(m^3/min)$, a rotational speed 2886 (rpm) at the power 10 kw. which results 54% of the static pressure improvement relative to the original blade.

  • PDF

상용 CFD코드를 이용한 냉각홴 공력소음의 발생 및 방사 해석 (Analysis of the Generation and Radiation of the Fan Noise by Using Commercial CFD Code)

  • 전완호
    • 한국유체기계학회 논문집
    • /
    • 제5권1호
    • /
    • pp.13-19
    • /
    • 2002
  • In the present study, a numerical simulation is performed for the flow through a cooling fan. The computation was performed by using commercial code, STAR-CD. A rotating fan was simulated by rotational motions using MRF (Multiple Rotating Reference Frame) in a steady-state analysis and sliding interface (rotating meshes) in an unsteady-state analysis. The results of numerical computation were in good agreement with experimental data. In order to calculate the acoustic signal, the unsteady flow-field was firstly calculated. The acoustics of the fan is calculated by using acoustic analogy based on the unsteady flow-field. The predicted acoustic signal shows the characteristics of the uneven bladed-fan.

공기조화기 축류팬의 공력소음 특성 연구 (The Study on the Aeroacoustic Characteristics of an Axial Fan for an Air-Conditioner)

  • 이수영;한재오;김태헌;이재권;전완호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.205-208
    • /
    • 2006
  • This paper proposes a new computational aeroacoustics method for an axial fan analysis. The major aeroacoustic noise source of an outdoor air-conditioner is the axial fan. It was revealed that the dominant noise source is the aerodynamic interactions between the rotating blade and stationary orifice. Many researches were focused on the fan only case. However, it does not fit to a real outdoor unit of air-conditioner. Especially, the inlet part of the axial fan of real system case is complex and not uniform. So, in order to identify the dominant noise source of axial fan, full outdoor unit analysis is important. Transient CFD analysis of full system was performed by commercial CFD code - SC/Tetra. Dominant noise source of the system was calculated by commercial CFN code - FlowNoise. The results show that not only BPF peaks but also broadband noise are similar to the measured data.

  • PDF

실험계획법을 이용한 시로코팬의 성능향상 (Performance Improvement of Sirocco Fan using Design of Experiments)

  • 최영석;정욱희;이경용
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.283-286
    • /
    • 2006
  • This paper presents a numerical study on the overall performance and local flow characteristics of the sirocco fan. The effects of impeller and volute shape distribution on the performance of the sirocco fan were numerically studied using a commercial CFD code and a DOE (design of experiments) software. At present, our attention was focused on the relation of the results of DOE and the performance of the sirocco fan. As a main result of the optimization, the performance of the sirocco fan was successfully improved. Also, detailed effects of geometric parameter of impeller and volute in the sirocco fan were discussed.

  • PDF

제트홴에 의해 형성되는 터널내 유동의 실험 및 수치적 해석 (Numerical and Experimental Analysis of Tunnel Flow Induced by Jet Fan)

  • 김정엽;양상호
    • 한국유체기계학회 논문집
    • /
    • 제13권3호
    • /
    • pp.59-64
    • /
    • 2010
  • To analyze the three-dimensional flow in tunnel caused by operation of jet fan, both experimental and computational studies have been conducted. The experimental analysis of tunnel flow induced by jet fan is conducted on a real-scale apparatus with jet fan and tunnel, and air velocity at the monitoring points is measured for variation of fan's RPM. The three-dimensional numerical analysis including tunnel and jet fan is carried out for the same geometric configuration as the experimental analysis. The experimental and computational results are compared to examine the applicability of the numerical method.

Design and Experimental Studies of Radial-Outflow Type Diagonal Flow Fan

  • Kinoue, Yoichi;Shiomi, Norimasa;Setoguchi, Toshiaki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제6권1호
    • /
    • pp.18-24
    • /
    • 2013
  • In order to apply the design method of diagonal flow fan based on axial flow design to the design of radial-outflow type diagonal flow fan which has lower specific speed of 600-700 [$min^{-1}$, $m^3/min$, m], radial-outflow type diagonal flow fan which specific speed was 670 [$min^{-1}$, $m^3/min$, m] was designed by a quasi three-dimensional design method. Experimental investigations were conducted by fan characteristics test, flow surveys by a five-hole probe and a hot wire probe. Fan characteristics test agreed well with the design values. In the flow survey at rotor outlet, the characteristic region was observed. Two flow phenomena are considered as the cause of the characteristic region, one is tip leakage vortex near rotor tip and another is pressure surface separation on the rotor blade.

비정렬 격자기법을 이용한 횡류팬(Cross-Flow Fan)의 비정상 유동해석 (NUMERICAL PREDICTION OF THE CROSS-FLOW FAN PERFORMANCE AND NOISE CHARACTERISTICS BY UNSTRUCTURED FLOW SOLVER ALGORITHM)

  • 조용;문영준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1998년도 추계 학술대회논문집
    • /
    • pp.36-41
    • /
    • 1998
  • The cross-flow fan performance and its sound noise characteristics are predicted by computational methods. The unsteady incompressible Navier-Stokes equations in moving coordinates are solved by a SMAC method on unstructured triangular meshes, using a sliding mesh technique at the interface between the domain rotating with blades and the rest stationary part. The computationally predicted fan performance was favorably compared with experiment, and some numerical aspects of simulating the cross-flow fan are discussed. With the computed unsteady flow field, aeroacoustic sound noise of the fan is predicted by the Lighthill-Curie equation. The unsteady surface pressure fluctuations on stabilizer enables a prediction of BPF noise of the uniform pitch blade fan quite accurately. The aeroacoustic sound noise characteristics of both uniform and random pitch blade fans are also examined by SPL spectrum analysis.

  • PDF