• Title/Summary/Keyword: false positive

Search Result 879, Processing Time 0.033 seconds

An Adaptive Key Redistribution Method for Filtering-based Wireless Sensor Networks

  • Kim, Jin Myoung;Lee, Hae Young
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.6
    • /
    • pp.2518-2533
    • /
    • 2020
  • In wireless sensor networks, adversaries may physically capture sensor nodes on the fields, and use them to launch false positive attacks (FPAs). FPAs could be conducted by injecting forged or old sensing reports, which would represent non-existent events on the fields, with the goal of disorientating the base stations and/or reducing the limited energy resources of sensor nodes on the fields. Researchers have proposed various mitigation methods against FPAs, including the statistical en-route filtering scheme (SEF). Most of these methods are based on key pre-distribution schemes and can efficiently filter injected false reports out at relay nodes through the verification of in-transit reports using the pre-distributed keys. However, their filtering power may decrease as time goes by since adversaries would attempt to capture additional nodes as many as possible. In this paper, we propose an adaptive key distribution method that could maintain the security power of SEF in WSNs under such circumstances. The proposed method makes, if necessary, BS update or re-distribute keys, which are used to endorse and verify reports, with the consideration of the filtering power and energy efficiency. Our experimental results show that the proposed method is more effective, compared to SEF, against FPAs in terms of security level and energy saving.

Estimation of Leucine Aminopeptidase and 5-Nucleotidase Increases Alpha-Fetoprotein Sensitivity in Human Hepatocellular Carcinoma Cases

  • Abouzied, Mekky Mohammed;Eltahir, Heba M.;Fawzy, Michael Atef;Abdel-Hamid, Nabil Mohie;Gerges, Amany Saber;El-Ibiari, Hesham Mohmoud;Nazmy, Maiiada Hassan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.959-963
    • /
    • 2015
  • Purpose: To find parameters that can increase alpha-fetoprotein (AFP) sensitivity and so help in accurate diagnosis and rapid management of hepatocullular carcinoma (HCC), as AFP has limited utility of distinguishing HCC from benign hepatic disorders for its high false-positive and false negative rates. Materials and Methods: Serum levels of AFP, 5'-nucleotidase enzyme activity (5-NU) and leucine aminopeptidase enzyme (LAP) activity were measured in 40 individuals. Results: LAP and 5'NU were elevated in HCC at p<0.001. Pearson correlation coefficients showed that changes in AFP exhibited positive correlation with both 5'-NU and LAP at (p<0.001). The complementary use of LAP only with AFP resulted in an increase in sensitivity of AFP from 75% to 90% in detecting HCC. The complementary use of both LAP and 5-NU with AFP resulted in an increased sensitivity of AFP in detecting HCC from 75% to 95%. Conclusions: LAP and 5-FU can be determined in HCC patients in combination with AFP to improve its sensitivity and decrease false negative results.

clinical evaluation of pleural biopsy by cope needle (Cope씨 침을 이용한 늑막 생검에 관한 임상적 고찰)

  • 황윤호
    • Journal of Chest Surgery
    • /
    • v.19 no.3
    • /
    • pp.374-380
    • /
    • 1986
  • From June 1983 to September 1984, the pleural biopsies with Cope needle were performed at department of thoracic and cardiovascular surgery, Pusan Paik Hospital, Inje college, on 78 patients for exudative pleural effusion caused by various conditions. These results were analyzed clinically and summarized as follows: 2. The accuracy of pleural biopsy was 69.2% [54 of 78 patients]. The accuracy represented by ratio for the number of biopsy was 63.5% [54 of 85 biopsies]. 3. Among 61 patients of tuberculosis or malignancy, 37 [60.7%] were confirmed by pleural biopsy. 4. Tuberculosis was diagnosed in 48 patients, in 26[54.2%] out of these by pleural biopsy alone, in 3[6.2%] by pleural biopsy and isolation of AFB, in 2[4.2%] by pleural biopsy and operation, in 4[8.3%] by isolation of AFB, in 2[4.2%] by operation, and in 11[22.9%] clinically. 5. Among 13 patients of malignancy, 4[30.8%] were diagnosed by cytology alone, 4[30.8%] by pleural biopsy and cytology alone, 4[30.8%] by pleural biopsy and cytology, 1[7.7%] by pleural biopsy alone, 1[7.7%] by pleural biopsy and operation, and remained 3 by operation, lymph node biopsy, or bronchoscopy respectively. 6. False positive of clinical diagnosis was 12.5% for tuberculosis and 28.6% for malignancy. In pathological diagnosis there was no false positive. So specificity of pleural biopsy was very high. But false negative of pleural biopsy was 29.2% for tuberculosis and 46.2% for malignancy. 7. 4 cases[5.1%] of minimal pneumothorax were in the early series.

  • PDF

QSO Selections Using Time Variability and Machine Learning

  • Kim, Dae-Won;Protopapas, Pavlos;Byun, Yong-Ik;Alcock, Charles;Khardon, Roni
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.64-64
    • /
    • 2011
  • We present a new quasi-stellar object (QSO) selection algorithm using a Support Vector Machine, a supervised classification method, on a set of extracted time series features including period, amplitude, color, and autocorrelation value. We train a model that separates QSOs from variable stars, non-variable stars, and microlensing events using 58 known QSOs, 1629 variable stars, and 4288 non-variables in the MAssive Compact Halo Object (MACHO) database as a training set. To estimate the efficiency and the accuracy of the model, we perform a cross-validation test using the training set. The test shows that the model correctly identifies ~80% of known QSOs with a 25% false-positive rate. The majority of the false positives are Be stars. We applied the trained model to the MACHO Large Magellanic Cloud (LMC) data set, which consists of 40 million lightcurves, and found 1620 QSO candidates. During the selection, none of the 33,242 known MACHO variables were misclassified as QSO candidates. In order to estimate the true false-positive rate, we crossmatched the candidates with astronomical catalogs including the Spitzer Surveying the Agents of a Galaxy's Evolution (SAGE) LMC catalog and a few X-ray catalogs. The results further suggest that the majority of the candidates, more than 70%, are QSOs.

  • PDF

Shot Boundary Detection Using Relative Difference between Two Frames (프레임간의 상대적인 차이를 이용한 비디오의 셔트 검출 기법)

  • 정인식;권오진
    • Proceedings of the IEEK Conference
    • /
    • 2001.06d
    • /
    • pp.101-104
    • /
    • 2001
  • This paper proposes a unique shot boundary detection algorithm for the video indexing and/or browsing. Conventional methods based on the frame differences and the histogram differences are improved. Instead of using absolute frame differences, block by block based relative frame differences are employed. Frame adaptive thresholding values are also employed for the better detection. for the cases that the frame differences are not enough to detect the shot boundary, histogram differences are selectively applied. Experimental results show that the proposed algorithm reduces both the “false positive” errors and the “false negative” errors especially for the videos of dynamic local and/or global motions

  • PDF

Usefulness of FAST for Evaluation of Blunt Abdominal Trauma Patients (복부둔상 환자의 혈복강 진단에 있어 FAST의 유용성에 대한 고찰)

  • Chu, Yong Sik;Kim, Ok Jun;Choi, Sung Uk;Lee, Jung Han
    • Journal of Trauma and Injury
    • /
    • v.19 no.2
    • /
    • pp.135-142
    • /
    • 2006
  • Purpose: We planned to determine the diagnostic capability of focused assessment with sonography for trauma (FAST) in cases of blunt abdominal injury (BAI). Methods: A retrospective analysis of FAST sheets was performed from April 2002 to December 2004. During the study period, 135 BAI patients were evaluated with FAST at the Emergency Department of Bundang CHA Hospital. Of this group, twenty-eight patients were excluded, leaving 107 patients for analysis. Abdomen CT (computerized tomography) or exploratory laparotomy confirmed the presence of hemoperitoneum. At the secondary survey, patients underwent a three-view FAST examination (LogicQ; General Electric, Waukesha, USA) by an emergency physician, followed within 2 hours by an abdomen CT or exploratory laparotomy. The FAST examination was considered positive if it demonstrated evidence of free intra-abdominal fluid. Results: There were 45 true-positive FAST examination, 57 true-negatives, 1 false-positive, and 4 false negatives (sensitivity 91.8%, specificity 98.3%, positive predictive value 97.8%, negative predictive value 93.4%). The area under the ROC curve was 0.951 for the FAST examination. Conclusion: FAST is a highly reliable method for screening patients suspected of having BAI for the presence or absence of hemoperitoneum.

NONPARAMETRIC MAXIMUM LIKELIHOOD ESTIMATION OF A CONCAVE RECEIVER OPERATING CHARACTERISTIC CURVE VIA GEOMETRIC PROGRAMMING

  • Lee, Kyeong-Eun;Lim, Johan
    • Bulletin of the Korean Mathematical Society
    • /
    • v.48 no.3
    • /
    • pp.523-537
    • /
    • 2011
  • A receiver operating characteristic (ROC) curve plots the true positive rate of a classier against its false positive rate, both of which are accuracy measures of the classier. The ROC curve has several interesting geometrical properties, including concavity which is a necessary condition for a classier to be optimal. In this paper, we study the nonparametric maximum likelihood estimator (NPMLE) of a concave ROC curve and its modification to reduce bias. We characterize the NPMLE as a solution to a geometric programming, a special type of a mathematical optimization problem. We find that the NPMLE is close to the convex hull of the empirical ROC curve and, thus, has smaller variance but positive bias at a given false positive rate. To reduce the bias, we propose a modification of the NPMLE which minimizes the $L_1$ distance from the empirical ROC curve. We numerically compare the finite sample performance of three estimators, the empirical ROC curve, the NMPLE, and the modified NPMLE. Finally, we apply the estimators to estimating the optimal ROC curve of the variance-threshold classier to segment a low depth of field image and to finding a diagnostic tool with multiple tests for detection of hemophilia A carrier.

Microcalcification Extraction by Using Automatic Thredholding Based on Region Growing (영역 성장법을 기반으로 자동적인 임계치 설정을 이용한 미세 석회화 추출)

  • 원철호;권용준;이정현;박희준;임성운;김명남;조진호
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.235-242
    • /
    • 2004
  • In this paper, we proposed the algorithm for detection of microtalcification by automatic threshold decision based on region growing method. The region for optimal threshold is grown from local maximum pixel by increasing repeatedly threshold in microralcification candidate region. Then, the optimal threshold is automatically decided at the maximum value of the contrast and edge sharpness in this region. Microcalcifications could be efficiently detected as satisfied result that true positive ratio is 81.5% and average false positive numbers are 1.1 about total 299 microcalcifirations in real image. In a result, we showed that this algorithm can be used to aid diagnostic-radiologist for the diagnosis of the early phase of breast cancer.

Comparison of RPR Card and Mediace RPR test by KFDA Guideline

  • Lee, Hae Soon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.3
    • /
    • pp.124-127
    • /
    • 2012
  • Syphilis is an infectious and sexually transmitted chronic disease caused by Treponema pallidum. On the basis of clinical findings, the disease has been divided into a series of overlapping stages, which are used to help guide treatment and follow-up. Persons who have syphilis might seek treatment for signs or symptoms of primary infection, secondary infection and tertiary infection. Latent infections are detected by serologic testing. A presumptive diagnosis of syphilis is possible with the use of two types of serologic tests: nontreponemal tests and treponemal tests assay. The use of only one type of serologic test is insufficient for diagnosis, because each type of test has limitations, including the possibility of false-positive test results in persons without syphilis. KFDA published Koreans guideline of Sexually transmitted infections in 2011. Two hundred samples were tested by RPR card test and Mediace RPR test with simultaneously. The agreement between RPR card test and Mediace RPR test was 95%, the discrepant samples was 5%. The characteristics of 10 discrepant samples was RPR card Positive and Mediace RPR negative nine samples, RPR card negative and Mediace RPR positive one sample. The nine samples were confirmed as FTA-ABS by KFDA guideline of syphilis test algorism, all IgM test was Negative, all IgG test was reactive. So, these cases were past or latent syphilis. The one sample was false-positive reaction.

  • PDF

Development of Reverse Transcriptase Polymerase Chain Reaction Primer Sets and Standard Positive Control Capable of Verifying False Positive for the Detection of Severe acute respiratory syndrome coronavirus 2

  • Cho, Kyu Bong
    • Biomedical Science Letters
    • /
    • v.27 no.4
    • /
    • pp.283-290
    • /
    • 2021
  • Severe acute respiratory syndrome coronavirus (SARS-CoV2) is a major coronavirus that infects humans with human Coronavirus (HuCoV)-229E, HCoV-OC43, HCoV-HKU1, HCoV-NL63, Severe acute respiratory syndrome coronavirus (SARS-CoV) and Middle east respiratory syndrome coronavirus (MERS-CoV). SARS-CoV2 is currently a global pandemic pathogen. In this study, we developed conventional RT-PCR based diagnostic system for the detection of SARS-CoV2 which is relatively inexpensive but has high stability and a wide range of users. Three conventional RT-PCR primer sets capable of forming specific band sizes by targeting the ORF1ab [232 nucleotide (nt)], E (200 nt) and N (288 nt) genes of SARS-CoV2 were developed, respectively, and it were confirmed to be about 10~100 times higher detection sensitivity than the previously reported methods. In addition, a standard positive control that can generate specific amplicons by reacting with the developed RT-PCR primers and verify the false-positiv from contamination of the laboratory was produced. Therefore, the diagnostic system that uses the RT-PCR method is expected to be used to detect SARS-CoV2.